Document qxpZZEXmMX7aBo7nG95zZoVM
To: Distribution
Interoffice Communication
From: Date:
Subject:
J. A Bodron December 4, 1989
1939 ANNUAL VCM SURVEY
The 1989 Annual VCM Survey has been completed. This survey was used by Maintenance to locate and repair the listed VCM leaks and to determine fugitive VCM emissions.
Attached is a list of the VCM leaks found in the 1989 survey. The 1989 survey located a total of 20 leaks and was conducted during the week of October 9 in the New Module and the VCM Tank Farm, and during the week of July 17 in the Old Module.
During the week of October 16, all leaks found in the New Module and the VCM Tank Farm were repaired. The two leaks found in the Old Module were repaired the week of July 24.
J. A. Bodron Co-op Process Engineer
Co-op Process Engineer
/tjs
cc: RWS, DCS, PJK, BLT, JVU, CJMc, DFJ, RtfN, SCH, DAM FGJ, JBA, KWB
A!
BM 4
T
VAB.0001217526
T
ANNUAL
VCM 1989
SURVEY
I. NEW MODULE
LEAK TYPE PPM
001
V(L) 500
002
003 004 005 006 007
V(L) V(V) F(V) F(V) F(V) F(V)
800 700
60 200 150 200,
006
F( V) 500
009
010
F( V) F( V)
80 70
Oil
V(V)
100
LOCATION
East RVCM Charge Pump, pressure gauge fitting on bleeder valve
RVCM Filter PAK, FL-719, Valve on top
Reactor 741, Shell level. Bleeder Valve #572
Reactor 742, Shell level, Condensor Bolt
'Reactor 742, Shell level, Condensor Bolt
Reactor 741, Condensor level. Flange on top
Reactor 741, Condensor level, Condensor Bolt Be twe e n #14- #6
Reactor 741, Condensor level, Condensor Bolt Between #35- #27
Reactor 741, Condensor k
Reactor 742, Condensor Flange
i Reactor 745, Condensor Control Valve
level, level.
\
level.
Condensor Bolt #37 Bottom North Side,
Bottom, North Side
A
II. VCM TANK FARM
LEAK TYPE PPM
LOCATION
101
V(L)
500
Sphere VCM Transfer Pump, PP-219, Pressure gauge on Bleeder Valve
102 F(L) 50 Sphere VCM Transfer Pump, PP-270, Flange on
Bleeder valve located oust east of pump
103
F(L)
50
South VCM Unload Station, East side. South of
connection platform. Valve closest to platform
on connect hose
104 F(L) 50 Middle South VCM Unload Stat ion, East side. South of connection platform, Valve closest to platform on connect hose
105
F(L) 500
Middle North VCM Unload Station, West side, Inside manway on railcar. Temporary connection. North side of manway
*
VAB.0001217527
106
F(L) 500
107
F(L)
50
III. OLD MODULE
LEAK 201 202
TYPE *
V(L) V(V)
PPM
I
.Middle North VCM Unload Station, West side. Inside manway on railcar. Temporary screw vonnrction, West side of manway
North VCM Unloading Station, West side Inside manway on railcar. Plug, South side of manway ,
t
LOCATION
East of VCM Receivers, Filter, Bleeder Valve
Reactor 500, Actuated Valve for Evacuation Line
I
VAB.0001217528