Document qmvLBzBN5EnQQgE6rn4Kzq7DK
9T9SS0 SNOW
DEPT. A-246
Mix Tank)
Kind of Mix ;_______________________
V* Ho`
Material BP Iap I Date 1
Added
t!
i
;i
i
-----------ji---------------- *,
i <1
i 1
Sampled by
'
Analysis received: Date
Sp. Gr. ____________________
Time
All m Operator
-
Date ^_________________ _____ ___ Time
r'- .active Index
! Time __AM- PM
Adjustments & Kcrr.mnles
later ial |
51
Added
i DP i AP Date
jJ
Sampled
j
Analysis Received
sTixiS ; Operator Date | Time (operator Date JTime 1 So. Gr.
i* < is
* s<
j; \i
!i
i. ; i
-1 i J
1 '<
< _______________
i t___________l________1______________
_ _______ !
ir 1i
f i i
! \J
________________________j_______ ________________________!_______ ______1 . _
________i_________i____________
FINAL SAMPLE TAKEN BY Press Blowing at PM
at
AM Press Cleaned at PM By
PM ,
AM
B6f-Ir
COMMENTS:
T9SS0 SNOW
91955
21.
fEPARTMEMT 259 - Standard Manufacturing, Process
ydraul~A-200 and 260
.. .. _...... . ..
APPENDIX J
.............................................. -
.
SAFETY AND TOXICITY DATA
......
The following data Is pertinent for Departments 246 and 259:
I. LOCATION OF SAFETY EQUIPMENT
..
A. Fire extinguishers
.
1. Carbon dioxide - 1st floor, NE of lean-to .. 2. Dry chemical - 1st floor, SE of lean-to -.........
3. Dry chemical - 2nd floor, west wall
4. Dry chemical - 2nd floor, viest wall
B. Gas masks
....
... . ............
1. 1st floor, on sprinkler house 2. 1st floor, outside west wall of repair room 3. 2nd floor, on west wall A. Control room, east wall
5. 4th floor, on handrail by #1 chlorlnator
C. Scott air pak
1. Outside west wall of lean-to
D. Emergency clothing
1. Box on 2nd floor, west wall
E. Safety shoviers with eye wash
1. Batch department, 1st floor
2. ''
" 2nd floor
3. "
" 3rd floor
4. Continuous department, 1st floor
'
5. "
" 2nd floor
6. "
" 3rd floor
7. West side of tank farm (alarm in control room)
8. Control room (eye batch only)
HONS 055619
DEPARTMENT 259 - Standard Manufacturing Process
'tPydraul A-2QO and 280 _
. : j._` ..
._
'22.
APPENDIX J (cont'd.)
~~ .........
SAFETY AND TOXICITY DATA
II. SAFETY PRECAUTIONS AND DATA
A. Personal safety equipment
1. Hard hat 2. Safety glasses 3. Goggles A. Rubber or canvas gloves 3. Rubber overshoes .......................
. .
B. Fire
'
' Pydraul A-200, 280 and their components are not fire
hazards. Automatic fire extinguishers and sprinklers have been installed in building CR to combat fires.
C. Toxicity (see next section)
D. Miscellaneous
There are many accidents that can occur which may be
classified as health and safety hazards. These accidents
can result from steam leaks, product leaks, and other
minor hazards normally present to some degree In a chemical
plant.
.
E. Safety Record (Depts. 2A6/259)
.
i 1. Lost time accidents - Last occurred on January 23, 19L3
2. Serious Injuries -- The last two serious Injuries
.
vie re:
(a) 8/5/70 - See attached informal investigation repor
(b) 12/2/68 - Refer to formal investigation reporu
L-17-20-68.
3> Minor injuries - For the years 1969 and 1970, the . frequency of minor injuries is about one per month., or about - 0.75 per man per year.
RONS 055620
23.
DEPARTMENT-259 - Standard Manufacturing Process Pvdra'uri-gOO and 2B0
APPENDIX J (oont'd.) _. . ... ...................... . . . SAFETY AND TOXICITY DATA
III. TOXICITY
.. .
A. Lubrizol 1360
This additive should not be heated above 120C as HgS can be liberated. HgS (hydrogen sulfide) Is a
poisonous gas.
B. '
Aroclors *
1. Recommended maximal atmospheric concentrations
. (MAC for 8 hrs.):
. ..
a) Aroolor 12h2 - 1.0 mg per cubic meter of air
b) Aroclor 12^ - 0.5 mg "
" " " "
. _ 8,_ Hazards and control ___________________________ ______ _
a) Inhalation; Absorption is chiefly by lrihala' ' tlon. Concentrations in the workroom atmosphere
should be maintained below the recommended levels. Where the chlorinated diphenyls are used at room temperatures, the hazard of inhalation is considered slight or absent. When these materials are subjected to elevated temperatures, the proces either should be completely enclosed or other adequate mechanical exhaust ventilation must be v provided to reduce concentrations to safe levels.
b) Skin contact: Operations and handling procedures should be. such as to avoid the possibility of
. prolonged or repeated skin contact. Contaminated : clothing must be laundered before reuse.
c) Eye contact: Eye protection should be used where thc-ro is a possibility of liquid splashes.
3. Emergency Treatment: Skin surfaces exposed to chlorodlphenyls should be thoroughly washed with soap and water at once. If clothing has been contaminated is should be removed promptly.
If exposure to a high vapor concentration occurs, as in the case of spills at elevated temperatures, the patient should be moved from exposure and kept at rest until seen by a physician. Oxygen should be administered if breathing is difficult.
MONS 055621
DEPARTMENT 259 - Standard Manufacturing Process
P.vdraul A-200 and 280
.'
'
APPENDIX J (cont'd.) .
. SAFETY AND TOXICITY DATA (cont'd.)
III. TOXICITY (cont'd.)
3. Eyes contaminated with chlorodiphenyl should be Irrigated with water for at least 15 minutes and
the patient should be seen by a physician.
4. Special procedures: Persons who are regularly or repeatedly exposed to chlorodlphenyls should
be examined periodically to detect early evidence of skin Irritation and/or liver damage. Persons
. with known liver disease should not be exposed to repeated contact with the chlorodlphenyls.
*The Information In this section Is from the Hygienic Guide Series published by the American Industrial Hygiene Association. The 'particular pamphlet Is "Chlorodlphenyls", Jan.-Feb. 1965.
0NS 05562Z
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0
APPENDIX K BACKGROUND INFORMATION
Monsanto began producing Aroclors in 1929 and has been using the same process in principle ever since. Specifications on Aroclor became more stringent with time. The General Electric Company mixed some of the different Aroclors to form products with intermediate physical propertie and named the mixtures Pyranols. Later, Aroclor was mixed with Trichlo
robenzene, tri-tetrachlorobenzene, toluene, butyl acetate and cresyl diphenyl to form pyranols with special properties. As products with lower allowable free organic chlorides were required, chloride scavenger such as tin tetraphenyl, glycldyl phenyl ether and Unox Epoxide were added to the mix.
Pyranols at the present time are formed by mixing Aroclor and Triohlorobenzene or Tri-tetrachlorobenzene. Glycldyl phenyl ether and unox epo xide are the best chloride scavengers now known and are the only chlorid scavengers used.
Monsanto's Aroclors, especially the chlorinated biphenyls Including
type6 1242, 1248, 1254 and 1260, used alone or in combination with
chlorinated benzenes, are commonly used dielectric materials of the
'ASKAREL class.
"
Askarel is a generic name referring to liquid dielectrics derived from halogenated aromatic compounds possessing excellent chemical and di
electric stability and fire resistance over the temperature ranges and Operating conditions of transformers and capacitors in the electrical
industry. The electrical industry's use of these fluids have been in accordEinco with the General Electric Company's patents and developments.
Resulting from the wide use of these materials in the electrical indusbr trade names have been established to identify them by different manufac turers of electrical equipment. Listed alphabetically, the trade names Include, "Chlorextol," Allis Chalmers; "Diaclor," Sangamo Electric; "Dykanol, " Cornell Dubllier; "Elemex," Line Materials: "Hyvol," Aerovox; "Inerteen," Westlnghouse Electric; "Noflamol, 1 Wagner Electric; . and"Pyre.nol," General Electric Company.
The electrical and fire-resistant properties of Askarel type fluids have enabled them to capture a share of the market from the lower-cost transformer oils.
MClNS 055623
DEM'. 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0
APPENDIX L
TIME CYCLE
The cost standard capacity (1970 and 1971) of Dept_;_ 259 for Pyranol production is 1.7 M lbs./mo., or approximately 20 K lbs./yr. me production for 1970 will be about 15.0 M lbs. Storage facilities are the limiting factor in Pyranol production. There are no finished goods storage tanks. Tank cars are loaded and drums filled directly from #2 or #3 Mix Tank. The fact ..that four electrical grade blcndh
are made in two mix tanks means that at most, two of the four blends
are available in bulk quantities. If both tanks were in the blending cycle, none of the blends would be immediately available in bu'k.
These facts also affect batch size. Efficient use of equipment, man power, and laboratory analysis would indicate that large batches should always be made. The pressure of time may dictate, however, that only a small batch be made, large enough for only one specific order. This would then make it possible to make a different blend immediately after
ward .
The following table shows an approximate time cycle for a 12,000 gal. batch of Inerteen 70/30, Inerteen PPO, or Pyranol A13B3B. A batch of Inerteen 54201 CM would take less time because it does not contain a chlorobenzene.
TIME CYCLE
Step
70/30, PPO, or A13B3__
54201 CM
1. Charge Aroclor and chlorobenzene 2. Blend major components 3. Sarrmlc for control and analysis 4. Adjust and reanalyze (if necessary)
5. Charge chloride scavenger 6. Blend total batch
7. Semple and final analysis 8. Earth treat and reanalyzed of
electrical properties (if necessary)
4 hrs. 4 2 0-6 1 3 10
0-6
2 hrs 1 3 10
0-6
Totals
24-36 hrs.
16-22 hrs.
Prom this point on, the batch cycle is dependent upon how the product is packaged. Bulk shipments can be loaded at a rate of 35-50 0PM depending on filter condition. Drums (55 gallon) can be filled at a rate of 40-44 per man per shift.
If for any reason a tank car analysis Is out of specification, the product may have to be unloaded to the mix tank, reworked, analyzed,
and reloaded.
MOIVS 05S624
DEFT. 259 ~ STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0
APPENDIX M
QUALITY COHSIDFjKATIONS
Pyranols and Inerteens are functional chemicals. Pyranols and Inerteens are used mainly as transformer fluids in the electrical industry. Qualities exhibited by pyranols and Inerteens Include , excellent chemical and dielectric stability and fire resistance over the temperature ranges required of transformers and capacitors.
Pyranols and Inerteens are manufactured under very carefully control!-:.? conditions in order to meet the strict and exacting electrical require ments and properties. Good quality Aroclor is essential for producing high grade Pyranols. Any contemplated process change must be care fully evaluated before the actual, change is made. Changes in product properties or off-grade products can extensively damage electrical equipment.
Notes on quality not mentioned elsewhere:
1. On one occasion TCB became mixed with TTCE. Mo pure tetrachlorobenzene was available so that the mixture could be made to moot TTCB specifications. The mixture was blended with TCB and used as TCB. After blending, the mixture contained alrout 3-4,"' tetra.chlorobcnzene. The Inerteens 70/30 and ppo made utill?in- this mixture were all in specification.
2. It is not always necessary to v:ash a tank car before loading it with a product different from its previous contents, assuming the heel is small (l?1' wid'e or less) and assuming that it is otherwise clean. Two such ca.ses are shown below. In the third case the cor must be washed because 542C1C1: does not contain chlorobenzene-:-,.
PRODUCT
TO BE LOADED
(a) Aroclor 1242 or 1254 (b) Any pyranol or Ir.erteen
Any Pyranol or Inert-.u:
Inerteen 70/;0,, PPO, or Pyranol AlJBpB.
(e) Inertoen 70/30, PPO, or Pyranol A13B3B must be washed.
Inerteen 54201 CM
3. A "quick and dirty" method for checking for organic contamination in Aroclor is to add sulfuric acid to the Aroclor and heat it. Tf contaminated, the Aroclor will turn dark. If not, it will rot: in its water white color. This test is not appropriate for the electrical grade blends because the chloride scavenger wi.ll alwaye turn black.
MONS 055625
Dept. 59 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0
APPBNDIX N
.
Miscellaneous
This section contains the following data: 1. Additional raw material information S. References 3. 1971 Production Cost Standard 4. Operations Report (1970 YTD) 5. Status Report of Department 246 Safety Audit 6. Dept. 246 Safety Audit 7. 1970 Aroclor Group Objectives 8. Manufacturing Improvement Plan
HONS 055626
Dept. 259 - STANDARD MANUFACTURIHO PROCESS Pyranols, Inerteens, and FR-0 APPENDIX N Miscellaneous Haw Materials 1. TCB and TTCB
TCB and TTCB are received In tank car quantities from Hooker Chemical Company. The tank cars are samples and analyzed for specific gravity and index. The other properties are determined from the suppliers Certificate of Analysis. Cars are unloaded into a storage tank. Tank trucks are used to supply TCB and TTCB during times of shortage of material. 2. Aroclor 1242, 125*1, 1260 Received by pipeline from Department 246. 3. Qlycldyl Phenyl Ether Purchased from Shell Chemical Company in 55 gallon drums, 475 lbs. each. 4. Unox Epoxide (EP-221) Purchased from Union Carbide in 55 gallon drums. 5. Attaoulgus Earth ' Purchased in 50 lb. bags.
MOMS 055627
Dept, 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens and FR-0
APPENDIX N
'
Miscellaneous (continued)
REFERENCES
1. St. Louis Report No. 2072, Job No. 2-02-750.01 - 3428, May 4, 1958.
Title: Final Report on Aroclor Process Studies
'
Summary:
Purity of raw materials, catalyst concentration, reaction
temperature, and rate of chlorination were the variable-
studied with respect to their influences on the stability
of the finished product.
'
2. St. Louis Report No. 2420, Job No. 2-02-750.01 - 2681, January 0,
I960.
Title: Assistance to Sales and Development Departments on Aroclors, Biphenyl and related products.
Summary: Studies were made to measure physical properties and other data on the Aroclor series of compounds.
3. St. Louis Report No. 2540, Job No. 171-6.16, December 28, 1958.
Title: The Effect of Prolonged Heat on the Electrical Properties
of Aroclors.
'
Summary: Aroclors 1232, 1242, 1248 and 1254 were held at 130C. The power factor was periodically measured.
4. E. E. Martin, Process Description for the Manufacture of Pyranols and InerteensT"1''!. G. Krumj-irlch Plant, June, F?,.' '
5. P. G. Benignus, The Proper Handling of Aroclors and Their_!-[i`-;turi'.:-
In the Electric?..! Industry, Sc. LouTs~, TITy~~r)~
.
HONS 055628
PROPUC'flOM COST STAHPABD
_ .Mss: .j,K
PAY TO PIV. LOC. DIV. LOC. CCTR
s 6-7 t.U 12-13 U-17 1B;20_
\ 7L2. ' iV;I' J.k c.o_;-.V
[CAPACITY:
//VP,
(.COST UKIT i
Z07-f
DUPLICATE COLS.4.7S INTO ALL CARDS
PI.A NT
U/l HRvawHIk
I I'ogf of
MONS 055629
PRODUCTION COST STANDARD
HONS 055633
-asmi SCHED.
ACT.YTJ
DEPT. 246 1970 OPERATION REPORT jclors 811.00
PRODUCTION - TOTAL AROCLORS(42 -7M# In 1969)
jIAJL. _E3* MAR.
APR. MAT
JUNE
JULY ! AUG.
SEPT, i OCT.
NOV. DEC
bll86X3 `ig84l58fej 396998^ 3969^ 397325^ 4Q549Q41 5055954 j 4267264 i 3T93T9l| 3<>s^TX3j 4633637 j 592"
1232 1242 1248
1284
1260 1262
PRODUCTION - AROCLORS BY KIND
0!
0|
0
------ 1 1 { ......... . r.......... \
'
rrsoo -0- | .0- 1 0 i-o-
2133478 !i659600| 2720903 24633r>d?'',4n7?cj 2293136:2360725 12227525
329056 5489811 38806Q
9a/i7Ro! 58795S! qtoi i 569605
399369 573264 ! 519416* 5102211
825887! 1432762 !u63566
286710 597391 34l6od 21951'! 746600! 3U923! 291051 1 306577
0 0 | 0 0 ------!-------- --52200-I--^2=-----------
-0-
2471054 225583
722600
' 415814 -0-
-0- " j -02658334! 3659746
325488j 285346 883225| 446041 217666) 242554
-0- !
!
42? 46?2
5>P8 521' 4443 -0-
MONTH YTD
TCC RESISTIVITY POWER FACTOR
NO. OF LOTS
" XII'OR
S5R73S5_
*
w
__EER_CENI_YIELD_ ON BIPHENYL.: _ S td :98.0# 1969? 29 23 100.991 101.82 98.62 100.6g 98.78 100.26 101.60 101.31 100.99! 101.39 100.2^ 100.38! 100-3 100.07 100.35 100.48
99-19 102.13 100.34 100.52
100.93 100.57
99-:
100.:
AVKRAOK QT7AT.TTY O.lll 0.15!
OP 1242 0.14!
EG LOTS :___(1969. AvPIS0.15
0. id 0.20
0.16 0.16
DT)m: ROOO x 106'^
0.12
0.15
ohm-cm 3; 2.1%1 )*-l
0.2^
0.23
59001 12270
976d ->.96flr\ 10970 14780 9480 14,660
7640 12,900 14,900
I.65! 1.6l! 0.98 0-57! 0.74! 0.97 l-j6.. 0.91
1.37 1.12
1.10
4! 6 8j 4 8
A 6 4'
68
0.?. 14,4c
C.o.
17
SAFETY(12 minor in.luri es m 19691
X
1 0!
21
i ,'
o| oi 0 ! 0: 0
,-0- 1 2 -0
0_ 0 00
0
0 0
. .2.
OVERTIME O.T., YTD EXTRA HRS. E.H.jYTD ABSENTEE HRS. ABSENTEE HRS.YTD
JAN. 8.2 8.2
9.7 9.7 2.5 2.5
FE3. 11.4
9-7 6.9 8.4 2.5 2.5
MAR. 5.6 8.5 11-5
9-5 1.7 2.2
APR. 8.1 8.ft 5.4 8.4
5.8 2.6
MAY JUNE JUDY AUG.
12.0
21.4 22.0 14.9
0.0 10-9 12.7 13.0
7.7 8.3 2.6
7-1 . fi.T 1.5
9-? P. 3 20
.3-4 7.6 6.3
2.6 --------2t4- ---- 2-3---- 2.9
SEPT. 16.6 13.4 6.5 7-5 13-6
4.0
OCT. 17-6 14.0 12.4
8.1
<3.8 4.7
NOV. 8.2
13.6 7-6 8.1
4.0
4.6
DEC. 9.0
12.1 0-5
6-7 1.2
4.3
WHSE. TOTAL
INVENTORY (1969 Average: Whse. 124OK#, Dept. 1320M#)
1091 11621 1056 f 1017 COO
459. 463
1285 10981 926 | 1238 no5 ...
789 1264
2576 226o! 1982 I 2255 bj>2Z___ 1248 1727
280
1233 1518
493 1411
1909
454 1071 1525
645 1176
1821
955 136C 2315
2 C2oo
o l UuO>l'
ACTUAL SCKED.
-AC3LXTP =
PRODUCTION
DEPT. 259 197;. JPSRATION REPORT Pyranols 810.90
TOTAL PYRAN0LSQ350K# in 19691 _________
i 97582ft 1 87ft607l 902782 jl5ft93ft2 112505*1 1332715 ! U7ft529 r 1152598 1015412! 2086825 i 11656161 i313-i6;-
97582ft! 87ftp07! 902782 fi.5;l93i<2 1125058 1512715 j H7ft529 lifiPfioRi 1015ftl2i 2086825 1 H656I6! 1813:16;
: 97582ft !l850ftR1^753213 i'1302555
6760328 | 793^557 '9057555 ! X0U2^T\ 12199792| I3365IO8] 15178871
1260.PPO;.
70/30: 12 2ft PPO -A13B3B
FR-0
TC3 TCB
ttcb
TTCB
Mo. YTD Mo. YTD
-vi.: 33125oi 116992 193100 ! mfiln
170 6 6052ft ftj ft
o! ft57ft72 j 6ft 1781
251366! 2C100o! 251000 ! 468100
2207ft5i 106095! (3790) ! 1278201
1|9ft5l6!
168l<T/!
287715
171163d
I8W136 J
1517ft ft !
il,RAKc!
1Ufipiflo
1000761
1617573
301125!
1M.755I
253877 ft9Y351 2ftft595 i
ifififlTil
96/18 ! 100.62 96.43 1 98.50 99.^1 i 96.38 99-411 99.18
99.03 98.69
-
99.16
100.7^ 1 99/12}
105.67 I 100.16 1
^LTL?. * r
101.01 _29_J1 99-79
99.76 99-75 99-75
98'. 93
98.26
99.31 101-31 100.95
90 GO
_29-73 102.3ft
-101.13_
3 05510'iois ft ft !
fteeirr.1 929867
UlOOo! ft20Q60
fiino! 371919
I29ft08
-0-
562562
365600 <147?!|0
311632!08oft6 -
.
-O- -0-
9Y.ftyj 99-ftft 99.63; 99-60
9fi-10| 103-99 100.72I 101.36
98.51 100.88
99-51 99-59 95-78 --103-09. 101.0ft 101.32
WHSK.._____________
KEPT.
'
TOTAL
'________
467 316 783
22S 185 ! 358 1 3li8
362 ftqfi ___ 363-- 323 j 66ft
212 288! 392 i 300
253 2ft1
152
336 | ft93
ftftO 473 ! 750 I 663 ____ 611, ___ X3.I__ SI <5
659 1 1157
78ft | 389 | 1173 !
773 10'T
HONS 055636
A533I&L 3rnr?T>
ACT. YTD
WHSE. DEPT. TOTAL
1
ACTUAL SCKED. ACT .YTD . . 3YDEAUL 625
TCP Mo. VCP YTD
WKSE. DE-tt # TOTAL
DEPT. 259 197> OPERATION REPORT Pydrauls A-2OO(8l0.96).
-p-RrmHUTTON - fl-20O(3.95I~'Jf In .19691
I .1AS- i EE3. I MAR. 1 APR. I KAY
JUKE JULY
92302! 1^0200 j 2707^1 ! ;I3200Q | 13,J22S! gfififcfts ?407fi0
92302; 3*; 0200:270741 I ^'32000 j
286485 2*>Q76o
! 92302 232SO? 1 5032*43 9352**3 j ?06046d 1355253 11596713
I AUG 281270
! 281270 I 1877283
SEPT. | OCT. *108380 ! 255500 408380 I 255500
2286363 |2581863
NOV, j DEC l16923 j 2Q*qL
*>16223 ! 29-'-V'i 295&VS5 j 325222I
INVENTORY A-200 d969 Average: Whse. 270M#, Dspt. 80#)
*415 179 195 44 5
75 89 0
71
2isj 6*1
176
21? _____ 152_
136 95
2Q
*490 268 195 516 _____ 27a! 312 312
181
t! 1
200 184 135 -0335 18*4
318 *>7 123 U*4l *>8
'-
Pydraul 280(811.19) PRODUCTION-280 Co.96m# In 19o9)_______ _________
0! 132500! 0! 132500I
0| 0 0| 0
9607^1 265000 JL318I5 0687^ 265000 131875
118750 118750
0 113125 125000 0 113125 225060
Cl 0
0 i 132SOoi 132500 | 132500 22937 53* *'9,|375-J 626250 7*45000 7*45000 858125 983125 98312
;.
. ..
'. 12Tl:2-
YIELD (TCP 1969 Act. 91.7#, 1970 Std. 93-0%) ______________________________ _____________________________
1 N/A I 97.26 , n/a N/A i 93.61! 98.79 ! 101.80
92-52 |
0 ! 98.09 108.31! 0.3.
! N/A i 97.26 97.2^ 97.26 ! 95. G8! 97.32 ! 98.23 1 97-27 1 97.27 j 97-38 98.651 90.
INVENTORY(1969.Average: Whse. 100M#. Dept. -0-1
I 85 !0
90 46 00
Mfl 0! 0
I I
22 | 72 22 ! 0
! 85
90 *46
46 1 1 1 *4*4 ! T2
! ! 1
58 58 11 5Q _____ S2_
173 35 1 -0- . -0- j
173 35 !
*>6 30 76
HONS 055637
^COMMENTS
JANUARY
Operations normal. "Extra hours" high due to
training for vacation relief and replacement of
man laid off;
'
FEBRUARY The resistivity of the 1242 EO lots would appear to be significantly higher, but this must be qualified.
First,' quality* averages are meaningful only over periods longer than one month because the range is
wide. Second, the laboratory air scrubber was installed and may(or may not) account for two unusually high resistivity analyses. .
The TCB and TTCB yields are actual for 1.970 and do not reflect credit received In 1970 for mischarges in 1968-69.
Pyranol stocks are low partly by decision.partly because of TCB shortage.
MAftcH APRIL MAY
JUNE
Operations normal. Volume increased.
Operations normal. Total group production was second highest on record. Total Pyranol production was at
highest level in past six years, reflecting shift of Aroclor 1260 and 1260 blends from Anniston. Better Aroclor electrical properties reflect improved analytical techniques - no reason to believe the quality has shifted.
The production rate continued at a high level. A bulk
shipment of Aroclor 1254/1C# Xylene was made in a trailer
in Dept. 268. The demand for Aroclor 126c was unusually
high causing some late shipments of 1260 blends. Be
ginning on about 5/12 and lasting for approximately one
week, sulfuric acid end carbon tetrachloride was entrained
in the chlorine received. All Aroclor 1242 produced
during this time was in specification (EQ) but unstables
were higher than normal. Aroclor 1254 made at this time
was also high lr. unstables but in spec. The 1254 was used
as non-electrical.
'
Sulfuric acid in chlorine continued to be .a problem in the
first half of June. High TCC's were noted in one lot of Aroclor 1242ECI; lot KM-477 had O.36 ppm vs. a "normal" of 0.1-0/2 ppm. Yields on Biff, TCB, and TTCB are all above standard for the month and YTD. TCP yield is below std., 97.32# actual vs. 99-0# standard, but is much Improved over last year's actual of 91.7#. Total Inventories, bulk and drummed, continue a downward trend. Overtime is high covering vacations and an open Still Operator's Job.
JULY
Total.Aroclor production vas highest ever, reflecting the sudden demand for plasticizers grades. Yields on ElJ, TCB, TTCB and TCP were all above standard. Drained 33 l/2 gallons of sulfuric acid
from the Clg brink tenks during the month. Total inventories vere raised considerably because of the increase intilss. Overtime vas high due to vacations and training of operators and new employees
to enable the dept, to increase production of heavy Aroclors.
MONS 055638
Miouar SEPT.
-2-
f.The ^demand for plasticiser Aroclor faded by mid-month. The 'four shift helpers hired to meet the high demand . during July/August vere released on 8/24. The demand for .drummed products .yas lower, as inventories of NE Aroclors.were allowed to drop to near. zero. The necessity for overtime decreased but was still higher .than normal. A serious injury (first for the year) vas.sustained by Cerl McCoy.
Production level returned to "normal" after high surge demands in July and August. "Normal" level will be increasing as customers ere transferred from Anniston to WOK. Shipped to Sprague Electric in September end will ship to Westinghouse, Bloomington, in October.
Since the B1 $ yield TTD continues to be over 100$, a few comments are in order. Since Aroclor 1242 is a mixture of isomers of varying molecular weights, degree
of chlorination is measured by sp. gr., 1.381-1.392 @ 25C, which corresponds to 41.5-42.5$ chlorine by weight. Theory chlorine is 42.0$. The percent difference in the amount of chlorine used between 42.0$ and 42.5$ by weight in the finished goods is about 1.2$. Therefore, it is theoretically possible to have over 100$ yields on Bi$ if the Aroclors are consistently chlorinated to near their upper limits and there are no significant losses. Bi $ tank car weights are not checked and may also contribute to the high yields. The biphenyl yield shown in this report reflects actual
operations. The cost report data will appear slightly different because some reworked Aroclor was transferred
to 811.00.
Resistivity of Aroclor 1242 EG has been better than last
year. This is probably more a factor of sampling and analysis than product quality.
The complaint procedure as practiced has changed. East
year complaints were formal. This year, complaints are
relayed personally and ected upon quickly. Formal complaints
are seldom written up.
'
Absenteeism is high because W. Walker and C. KcCoy have been absent about the entire month. Extra hours are high to cover the absenteeism, vacations, and for training a man to replace
R. Antoff 'who is being laid off - more in October. Overtime is high to cover absenteeism and for extra drumming.
TCB and TTCB yields ere actual on this retort. The cost report data will be different because it includes credit reseivea.-from Hooker.eerly_in .the year and because one lot of reworked Aroclor was transferred to Pyranols.
HONS 055639
OCTOBER NOVEMBER
-3-
Pyranol production set a record of 2.P0M lbs.' _Order level was high and inventories were increased by 0.5M lbs. to a Bore "normal" level. Whse. stock had been quite low.
Aroclor 1242E0 customers new to hue serviced In October were VTestinghous'e (Bloomington), CornelleDubilier, and Electronic
Components. The only former Anniston customer not yet served is Aerovex.'
Aroclor 1260E0 production is still out of specification on A.C. Cl" and sometimes on Monsanto Stability. Details on this problem are reported in a separate report. One indi cation of poorer Aroclor 124220 quality appeared in October. The TCC's have increased significantly, from an averege of 0.15.pm to 0.23 ppm, with two lots being over 0.30 ppm. A ' relationship betveen these two problems has pot been established.
Tbe primary reason for hi.gh overtime hours has been the high demand for drummed products; also some vacation time was covered with overtime. November O.T. should be less than 10.0$. A utility shift helper has been obtained for drumming. A third standard operator Job will be posted if drum demand continues. Extra, hours were high because three men were laid off (D. Hindman,
P. Butman, and D. Athy) and their replacements trained. This will continue into November. Absentee hours decreased from
September because- W. Walker returned in mid-month, but C. McCoy was again absent for the entire month.
Tbe third lot of Aroclor "scrap" was reworked. The material was Inerteen PPO.
Total Aroclor production in November was second only to July, 1970. Aroclor 1242 production was nearly l.CM lbs. higher than the previous high made in March, 1970.
The thermal chemical chlorides enalysis of Aroclor '1242 continued
to climb, a two-month trend. The range on 11 electrical grade
lots was 0.21-0.38 ppm; the average was 0.28 ppm. This trend Is
'not reflected in any other analysis.
'
Tbe Aroclor 1260 quality problem is still not resolved. There
is some evidence that at least part of the problem is analytical.
A sample of 1260 that was analyzed as out of specification by
the WGK laboratory (Monsanto stability and after corrosion'
chlorides) was in specification on both properties as analyzed
by the Anniston labor?.tory.
labor figures of overtime, extra hours, and absenteeism returned 'to more normal levels after high levels for several months.
ANTICIPATED IN' DECSSBR
"
1. Record production of Aroclor 1242 and total Aroclors.
2. Higher Inventories due to loading extra tank cars before
the receipt of orders.
3. High overtime, especially in still operator category:
4. First time production of Pydraul 625 and a short run of seldom made Aroclcrl232. HONS
055640
DECEMBER
-4-
Aroclor production was at an all-time high breaking the previous record_.(July, 1970) by 17$. Aroclor 12lt2 pro
duction vas -T3'! lbs. and downtime vas only about 0.5$. Using the standard OST of 91$ Aroclor 1248 capacity is about 52K lbs./year. This is approximately the same
capacity demonstrated several months ago in a tvo-day run.
Aroclor 1242 thermal chemical chlorides improved over last month but they are still higher than the 1969/firBt half of I970
"normal". Two lots of Aroclor 1260 were produced and both were In specification on all properties - first time in three months. Operating conditions were not changed for either the 1242 or 1260.
Minor injuries durine 1970 were 12 in number - identical to 1969.
Drum stocks of the fastest moving products were increased to
targeted levels - finally caught up from the surge demand experienced in July and August. The removal of slow-moving items is to be completed by 4/1/71.
Pyranol production was the second highest on record, Including
nearly 1.0M lbs. of Inerteen 54201 CM. Wo Inerteen PPO was produced and no more will be produced until open orders are in
hand. About 10,000 gallons of Pydraul 625 were produced. This
was the first time produced at W.G.K., and possibly only time. Pydraul 625 16 an obsolete product.
Total Aroclor Group production broke tbe old record (July, 1970)
by 23$.
MOWS 055641
MOM INAMt LOCATION, R. M. McCutchan. W. 0. Krummrlch
V/ICT
xrtAiNci TO
November 2, 1970
.
. ' .
Status of Dept. 246/259
'
Safety Audit Recommendations
of May, 1969
B. Corlew
V. Brawley T. Carrico D. O'Toole . D. Schlllinger
.
ThiB memo is a second status report on the 36 recom
mendations made in the Dept. 246/259 Safety Audit issued in May, 1969. The first Btatus report of 3/5/70 is attached. The box score is:
Date
Recommends tlon Completed
No Work
Job
Justified Open
May, 1969 3/5/70
9
36 3 24
11/1/70
19
11 6
Completions (or decisions to do no work) on the remaining six recommendations will be made by 4/l/71. Details on the current status follow. "Open" recommendations are marked with an asterisk. ,
Recommendations
'
1. (a) The west biphenyl storage tank (Item 102) should be controlled at 100C or below, or (b) the tank
equipped to handle a flammable liquid.
Status - A Taylor Fulscooe temperature controller cent:-
at 95C. Completed on 3/23/70.
2, (a) The batch biphenyl head tank (item 103) should be kept at or below 100C., or (b) the tank
equipped to handle a flammable liquid.
Status - Lowering the temperature of the biphenyl tank. (#1, above) causes the normal temperature in the biphen head tank to be about 100C. No further work will be
done.
*3. A means should be found to control the temperature in the biphenyl/catalyst mix tank (Item 403) at 100C or less.
Status - Work done on 7/1 (above) did not help much in controlling the temperature in the biphenyl/catalyst mi
tank. Further work yet to be done.
HONS 055642
B. W. Corlew Status of Dept. 246/259 Safety audit Recommendations
Pf May,..1969'.
Page 2 W.G.K.
11/2/70
Recommendations (cont'd.)
4. A high pressure alarm set for 45 psl should be Installed on the chlorine vaporizer (item 116).
Status - No work Justified.
5. A high pressure alarm set for 50 psl should be installed on the nitrogen header.
, *
Status - No work Justified.
6. The xylene storage area should be laid off and a sign "Xylene-Flammable" erected.
Status - Completed.
7. A means should be found to Insure that Lubrizol 1360 Is not heated above 100C.
Status - A drum of Aroclor 1248 was put on the plate coll heater for 4 days. At the end of the time, the
temperature was 65C. No further work will be done.
*8. (a) Put flooring on the level of the discharge piping
from the batch chlorlnators, or (b) direct the discharge lines away from the working area and a blown seal warning device be Installed.
Status - The rupture disc lines will be extended down to floor level after jf9 (below) Is resolved.
*9* Investigate the adequacy of the size of the rupture discs (8") and discharge line (3") on the batch ` chlorlnators.
Status - TSD investigating what is considered safe practice.
10. All temperature alarm and automatic cut-offs on all chlorlnators should be checked at 6 month Intervals.
Status - All safety devices have been put on a check list and are tested routinely by department or by Instrument shop.
HONS 055643
B. V/. Corlew Status of Dept. 246/259
Safety Audit Recommendations of May, 1969.:
Page 3 W.G.K. 11/2/70
Recommendations (cont'd.)
11. (a)
A procedure should be adopted to prevent
dropping the wrong chlorine tor batch to #2 blow tank, or (b) #2 blow tank should be properly equipped to handle a flammable liquid.
Status - m2 blow tank is now closed to the atmosphere as a result of the blow tank demister project. It is vented only to the drowning Jet. No other work will be done.
.
12. A level recorder should be Installed on //2 blow tank. .
Status - #2 blow tank now has a percentage gauge located in the control room and in the field.
13. (a) The gas fired still furnaces should be Insulated
and properly guarded, or (b) a warning sign be placed on the furnaces.
Status - Since there is very little work activity near
the furnaces, insulation or additional guarding is not
necessary.
14. Expedite completion of TSD Project 6928 - "Install Level Recorder on #2 Still".
Status - Completed.
15. Complete all actions recommended in formal investigation L-17-20-68.
Status - Completed.
16. Expedite.completion of TSD Project 6939 - "Install Level Measurement on Product Tanks".
Status - Completed.
17. Develop project to nitrogen blanket #1 and #2 Blend and Finished Product Tanks.
Status - These two tanks are not used often. Fumes are very minimal. No work is Justified.
MOMS 055644
B. W. Corlew
'
Status of Dept. 2*16/259
'
Safety Audit Recommendations
of Mav. 1969
. . r -
.
Page *<
W.G.K. 11/2/70
Recommendations (cont'd.)
18. Expedite completion of TSD Project 5377 - "Upgrade Lighting System in Dept. 2*)6".
Status - Completed.
*19. Determine flash point of Inerteen PPO, 5**201 CM, and 5**201 KA after the Glycidyl Phenyl Ether has been added. If the storage temperatures are within 15C.
of the flash point, either (a) Equip tank to handle flammable liquid, or (b) lower the storage temperature.
Status - Work yet to be done.
'.
20. Install relief system on 18" filter used when loading or drumming pyranols.
Status - No work Is Justified.
21. Upgrade grounding system for Xylene drums.
Status - Completed.
'
22. Concerning the Aroclor 125*1 - 10$ Xylene mix.
(a) Determine flash point of mix.
(b) Lower storage temperature as much as possible.
(c) Evaluate need for vent and flame arrestor on
' 01 blend tank.
(d) Ground in 01 blend tank.
(e) Ground the Xylene mix drumming facilities and further
alter to adhere to Monsanto safety specifications of
handling flammable liquids.
''
Status - All work was completed In anticipation of products an Aroclor 1260/10$ Toluene mix.
*23- Introduce a sufficient quantity of steam Into the scrubber stack to snuff out any fire which could conceive':.' occur at the outlet.
Status ~ Work yet to be done; evaluation.
2*). Expedite completion of TSD Project 700*1 - "Alter Truck
Loading Dock1'.
,
Status - Completed. '
.
HONS 0 sst1*5
B. W. Corlew
.
Status of Dept. 2*16/259
Safety Audit Recommendations
of May, 1969____________________
.
Page 5 W.C.K.
11/2/70
25* Write more specific procedures for shutdown during the preparation of a Xylene blend.
Status - No work will be done because Xylere blends
have been discontinued.
.
26. Evaluate need for an emergency exit on the north side of the department.
Status - The possibility of a person being trapped on * ' the north side of the second or third levels Is
extremely remote. No work Is Justified.
27* Provide for emergency lighting for Dept.2*l6.
Status - Purchase of emergency lighting is not Justified.
*28. Maintain a spare flame arrestor for Item *103 (catalyst mix tank).
Status - Will resolve when recommendation #3 is completed.
29. Relocate chlorine discharge line from chlorine vaporizer
rupture disc.
'
Status Completed.
30. Locate a 500# dry chemical fire extinguisher near .Item *101 (100,000 gal. biphenyl storage tank).
Status - No work Justified.
31. Items *101 and 102 should be identified "BIPHENYL-
FLAHMABIiS).
Status-Completed.
32. Extend fume removal system to continuous chlorinator area.
Status - Completed.
33* Improve lime delivery method to j?3 and #*l stills.
Status - A ramp has been installed on second level so
a dolly can be used for delivering lime. A' forklift
pad will be installed later (is a part of incineration
project estimate).
HONS 055646
B. W. Corlew
Status of Dept. 2^6/259 Safety Audit Recommendations of Hay. 1969____________________
Page 6
W.G.K., 11/2/70
34. Evaluate need for monitor nozzle near Item 401.
Status - No work Justified.
35* Evaluate need for controlled drainage from area
around Item 401.
Status - No work Justified.
.36. Install improved venting system on Item 102 (west Biphenyl tank).
Status - Completed.
'
/eJa
R. M. KcCutchan
hons 0
MONSANTO COMPANY ORGANIC DIVISION Vf. 0. KRUKMRICH PLANT
PROCESS SAFETY AUDIT department 246
AROCLORS, PYRANOLS, PYDRAULS
Supervisor __K. M. KcCetchr.n Supt.________ J . V' Ko31 oy Writ'. on by: II. F. Ray
K. M. McCutciv-n May - lSoJ
MONS 055648
Depts, 2hS and 259
SAFETY AUDIT RECOMMENDATIONS
The following list of recommendations are included in the Safety Audit. An approximate priority has been set by department supervision for
action on these recommendations. Targeted dates for completion of evaluation and/or action on the priorities are:
Priority
Pate
1 8/1/69
2 2/1/70
3 11/1/70
Recommendation
Priori
1. (a) The west biphenyl storage tank (Item 102) should be controlled at 100C. or below, or (b) the tank equipped to handle a flammable liquid.
2
2. (a) The batch biphenyl head tank (Item .103) should be kept
. at or below 100C., or (b) the tank equipped to handle a '
flammable liquid.
.
2
3. A means should be found to control the temperature in the biphenyl/catalyst mix tank (Item It03) at 100C. or less.
i
4. A high pressure alarm set for It5 psi should be installed . on the chlorine vaporizer (Item 116).
3 '
9. A high pressure alarm set for 50 psi should be installed on the nitrogen header.
3 '
6. The xylene storage area should be laid off and a sign "Xylene-Flammable" erected.
1
7. A means should be found to insure that Lubrizol 13o0 is not heated above 100C.
2
8. (a) IVt flooring on the level of the discharge piping fro:,'.
the batch chlorinators, or (b) direct the disch&rgo lines away from the working ei ea and a Mown seal warning device be installed.
3
9. Investigate the adequacy of the size of the rupture discs (8") and discharge line (3") on the batch chlorinators.
3
I. 0. All temperature alarms and automatic cut-offs on all chlorinotors should be checked et 6 month intervals.
1
II, (ft) A procedure should be adopted to prevent dropping the wrong chloririator batch to j"2 blow tank, or-- (b-)..,-;SL.bl,c.: tank, or (b) 7:-2 blow tank should be properly equipped {n handle a fle.tv8b)e liquid.
3
HONS 055649
pepls, 246 and 259 '
'
.
ii.
Recomjnehdation
Prio-jl
12. A level recorder should be installed on #2 blow tank.
3
13. (a) The-gas .fired still furnaces should be insulated and
properly guarded, or (b) a warning sign be placed on the
furnaces.
..
*3
1*1. Expedite completion of TSD Project 6928 - "Install Level Recorder on #2 Still.
1
15. Complete all actions recommended in formal investigation L-17-20-68.
1
16. Expedite completion of TSD Project 6939 - "Install. Level Measurement on Product Tanks".
1
17. Develop project to nitrogen blanket #1 and #2 Blend and Finished Product Tanks.
' -
18. Expedite completion of TSD Project 9377 - "Upgrade Lighting System in Dept. 246" .
1
19. Determine flash point of Inerteen PPO, 54201 CM, and 54201 KA
.after the Glycidyl Phenyl Ether has been added. If the storage temperatures are within 15C. of the flash point, either (a) Equip tank to handle flammable liquid, or (bj lower the storage temperature.
2
20. Install relief system on 18" filter used when loading or
drumming Pyranols.
.
3
21. Upgrade grounding system for Xylene drums.
1
22.' Concerning the Aroclor 1254 - 10# Xylene mix- .
1
(aj Determine flash point of mix.
F- (s3'c)
(bj Lower storage temperature as much as possible.
(cj Evaluate need for vent and flame arrestor on ,fl Blend
Tank.
fclJ Ground #1 Blend Tank.
(e) Ground the Xylene mix drumming facilities and further alter
to adhere to Monsanto safety specifications for handling
flammable liquids.
23. Introduce a sufficient'quantity of steam into the scrubber
stack to snuff out any fire which could conceivably occur
at the outlet.
.
2
,24. Expedite comoletion of TSD Project 7004 - "Alter Truck
' Loading Dock".
`
1
25. Write more specific procedures for shutdown during the prepare-
tion of a Xylene blend.
'
1
26. Evaluate need for an emergency exit on the north side of the department.
27. Provide for emergency lighting for Dept. 246.
HONS 055650
3
:Popts
and 259
i53 .
Recommendation
' Priorl ty
28. Maintain a spare flame arrestor for Item. 403 (catalyst
mix tank).
.
'p
'29. Relocate chlorine discharge line from chlorine vaporizer rupture disc.
1
30. locate a 500# dry chemical fire extinguisher near Item *101 (100,000 gal. biphenyl storage tank).
3
31. Items I01 and 102 should be identified "BIPHEMYL-FLM.D-LM'.LE).
1
32. Extend fume removal system to continuous chlorinator area.
2
33. Improve lime delivery method to #3 and //k Stills.
1
3^. Evaluate need for monitor nozzle near Item JlOl.
2
35. Evaluate need for controlled drainage from area around Item Uoi.
.2
36. Install improved venting system on Item 102 (west biphenyl tank).
2
MOMS 055651
PROCESS SArrg AUDI'.'
'"pept. 246
'1
Aroclors, Pyra.nols, Pydro.uls, Inerteens
Raw Materials
'
The following toxic rs.ting code will be used in describing the toxicity of these materials:
,' .
, J'
.
0 - none 1 - slight 2 - moderate
3 - high U - Unknown
-
'
Aj___Biphenyl (Code 82601)
1,. Synonyms: Diphenyl
-
2, Bes'crlp'tTon: White flakes or solid off white mass;
" aoniewh&t pleasant odor.
3. Constants: Mol. Wt. 15*1.2} H.P. 69C.; B.P. 255 C. ;
" JTenSTty .9910 Y5/4C.
'** Flash Point: 235' F. (C.C.)
5.* AuTo IghTtion Temperature: 1004 F,
6. Tox ic `ilaxar'cTRa t'fngf"
"Acute LocoTT 1/
Acute Systemic: Ingestion 3, Inhalation 3,
Chronic Local: U
.
* See Appendix I for definition of these terms
7. irc Retard: Definitely when exposed to heat or flame;
c'fii react with oxidizing materials,
.* 8. F3 re_fj giiting: C02 or dry chemical
9. Ponim'lK'r CgHjCgiij
.
10. Biphenyl vapors are irritating to the upper rer.p-j ratory
tract. Workers should not be exposed to vapor levels
throughout their shift in excess of the threshold limit
value of 1 milligram per cubic meter of air (or"about
0.2 ppm). The compound, or organic solutions of the
. compound car. abserb through the intact skin; therefore,
repeated skin contact should be avoided.
Biphenyl is received in 10,000 or 20,000 gallon lank c-' on Track 30A from. Anniston p.nd in 4,000 gallon Irei !<-: from Associated Sales. The crystallized biphenyl is r.c with 80 lb. steam using the coils in the cars and *0d:\t . hairpin coils if nccooc-ery.
There are temperature indicating on-off controllers on took unloading spots 5 end 6 to keep the biphenyl from heating ; the flash point. Temperature in the car is measured usi.iv; portable thermocouple end is controlled at 106C. 4_ ?.
HONS 055652
Biphenyl (continued)
,
During the plant air (30 psig wax.) unloading of the molten biphenyl there is no steam on the tank car colls so the materia] cannot be overheated. The transfer of the biphenyl to storage begins after the operator has visually inspected the car and has
determined all the biphenyl has melted.
The tank trucks received from Associated Sales are unloaded at the Spot fl\ tank car loading/unloading dock. The material in the tank truck is always in the liquid state and below the flash point so that no heating is applied in the department.
Tank car unloading spots 5 and 6 are equipped with self-supporti n counterbalanced unloading arms and plant standard Hemco adjusted
access ramps. Both docks are adequately grounded.
The molten biphenyl is then transferred to either the 100,000 gallon (Item *1 OX) or 2p,000 gallon (Item 102) storage tanks.
The biphenyl is stored in Item *101 at lOO'C. The tank is equippc
With a steam jacketed flame arrestor on the vent and a prolecto-
seal.manway cover to protect the tank against overpresourixation.
The tank temperature is controlled by a field mounted tempera tv-vc
indicating controller (capillary system) which allows 80# steam
to enter two fintubo heaters inside the tank. The tank tempera
ture is also recorded from a separate thermocouple on point #1
of the 2h point, panel mounted temperature recorder (TktS). A
high temperature alarm sounds of point 'l reaches 113*C. Stec.
pressure on the manway, flame akrestor, and pipe] lric`'tracerr. is
reduced to 58# to avoid heating'the product above the flash noS ::t
The tank level- is indicated, both at the tank and on the pend
board on a 0-100# dial gauge. This bank is grounded in three
places.
.
The biphenyl is stored in Item. 102 at 100 - 320C. .The tr.tii; temperature is recorded on point jf.1.1 of panel mounted ]? p-.;n`.
recorder 29 - 6638. There is no tempereture alarm system for this tank. The temperature,controller is a self contained field
Mounted capillary system utilizing 80:f steam. The tank is ve-./. e '
to the atmosphere and there is no dip-pipe in the charging 3 to the tank. Jtt__is ^recommended that either 1_. _Thc store.-; e temperature be cdnt"rol?Ied~Vv'"TOol'C, "or eeTow or 2.-....The" C"-y
ed"uippod~~to ftandTc ~a TT;::: jfoj'b TiguTri." -(Seer7.ps>enc: i x~ 3T ":'o: ; : . :
flara.ie.ble liquid handling condition.".) Items, *:0? and 102
.
be identified "Biphenyl.-riarr.r'.r.l; le" . Funs~fY6VT'th'vi'r.t "cr' *" ""
I'tem'jU'h are s3g.nfiTcc.ht SufTng "i. Transfer of biphenyl to T: it:.'
It is recommended that an improved venting method be ins's!':
on ft'ci.TTO'2
'...... '
""
"`
The biphenyl is transferred by a submerged punp from. Item 10? to cither the batch cblorinator head tank (Item 103), to the c:.`. =,];: mix tank (Item *103) or to #S cblorinator (Item AO6).
Item 103 is a 700 gallon measuring tank located in the batch
chlorinator area on the fifth level (top). There is a 1- l/h it ;.
traced and insulated overflew/Vent line back to Item 102 to .
tain a constant charge size (500 gal.) to the batch chiov 1
.
HONS 055653
-3A. Biphenyl (continued)
The biphenyl is kept molten with 80# steam reduced to 4o#. A 60#
relief valve protects the Jacket. 4o# steam (l42c.) keeps the
head tank temperature above the flash point of biphenyl. There is ho temperature recorder, controller or alarm on this system. This tank' is considered a closed vessel.
It is recommended that either 1. The tank temperature be kept at
oF'beT5w`TOlrCT or "2, lrne~'ofbhenyir>,ead tan!T~'&e"'prooerIy' eouTCbed
^Eal^Te~aTIartmabTg~Tlqu Id.'
5 --------------------~ ~
Item 403 Is a 1272 gallon feed tank located on the third level (top) in the continuous chlorlnator area. There Is a traced and
insulated 3 inch overflow line which ties into the l inch over flow line from the batch head tank on the second level of this batch chlorinator structure. The tank is vented to the atmosphere and is equipped with a steam Jacketed flame arrestor. Steam
pressure on the flame arrestor is controlled at 18#. The tank temperature is maintained by controlling the flow of 30# steam to an internal pipe coll utilizing a field mounted temperature indi cating controller (capillary system). Although-the tank temperatu. is set for 100C. the contents are normally in the range 120-1 j0`\:
due to tracer heat-up in the circulating system. Level in uKe'....... tank is Indicated at the tank and recorded on the control panel.
PeCl3 catalyst is Introduced into the tank manually on a once/dcy
frequency. The tank is open to the atmosphere when charging
catalyst.
It is recomm ended that means be found to allow the tank tempo rat < :.
to fee controlled at 100*0. joFTess, It is also recommended that"'1.
8pai'e~Tlame arrestor be 'maintaIne~cT7' '
'"
. Item"4(35 is e. 17255 gallon cFilorinetor located" immediately east of
Item 403. The biphenyl is fed continuously to this tank through
flow control system. The biphenyl is introduced into the chlori
nated reaction mass via a dip pipe, normal operating temperature
of this closed vessel is 1505C.
B. Chlorine (Code 81059)
1. Descrintion: Greenish yellow gas
2. 'Formula: Cl"g
3.' CoiTs'fants: Mol. V.'t. 70.914; M.P. - 101'C.j B.P.
' Density 1.4" @ 0C.
4. Toxic Hazard Rating:
~Acute~roca'J.: Irritant 3j Inhalation 3
Acute systemic: 0
Chronic local: U
.
Chronic systemic: U
M.A.C. - 1 PPM in air per 8 hour day
- 34.5eC.;
5. Toxicology: Chlorine is extremely irritating to the mucous membra'hes of the eyes and respiratory tract. It combines ;. H
moisture to liberate nascent oxygen and from hydrochloric a-
HONS 05565A
. -4 -
CJnlojpine (continued)
'
5. Toxicology: (cont'dj
.
both oi1-these substances, if present in quantity, cause in-
flararaation of the tissues with v:hich they cone in contact.
' . If the lung tissues are attecked. Pulmonary edema may re'sult.
ti, O
` A concentration of 3-5 ppm produces a detectable odor; 15 P
causes immediate irritation of the throat. Concentrations
50 PPM are dangerous for even short exposures. 3000 PPM nay
be fatal even when the exposure is brief.
Because of its intensely irritating properties, severe
industrial exposure seldom occurs, as the workman is forced
to leave the area before he can be seriously affected. In
cases where this is impossible, the initial irritation of the
eyes and mucous membranes of the nose and throat is followed
by cough; a feeling of suffocation and later pain and a
feeling of constriction in the chest. If exposure has been
severe, pulmonary ederr.a may follow with rSl.es being heard
over the chest.
.
6. Fire Hazard: Moderate - can react to cause fire or explosion upon contact with turpentine, ether, ammonia gas, Illuminati:
gas, hydrocarbons, hydrogen and powdered metals.
'7. Explosion Hazard; Present by reaction with reducing agents.
8. Disaster Control: Dangerous; emits highly toxic furies; v.,il3
react "with water "to form toxic and corrosive fumes of HC.l; Is
heavier than air - gas will, hug the ground. People without
adequate protection should go across wind until but of the
affected area.
.
Chlorine is transferred by a 6" pipe line from the Chlorine
Department. As it enters the department it passes through
two Brink Demisters (Items 115, 590) In parallel which re. ov:
any entrained liquids. From there it passes through a ch'.or'
. vaporiser (Item 116) which adds c-nough heat to prevent any
liquid chlorine from entering the system.
..
The vaporizer uses regulated 8Cj? steam to heat up the incomi . chlorine. If the Cl? pressure reaches *J0 lbs., the steam Is
automatically shut off thus preventing further pressure-
buildup.
If due to a plug in the chlorine line past the vaporizer, Vchlorine pressure builds up to pCj? a relief valve and a rupture disc will relieve the pressure. This sitv.ati.c n is ' highly unlikely as the chlorine supply pressure is cent; o1' at _30_;? in the chlorine department. However, since a failure in the steam controller or the chlorine department controls could cause a pressure of 5C,,- to bo exceeded arm' a subsequent discharge of chlorine gas to the, atmosphere, i.tJ -
recommended that a high pressure alarm for J}j5_ osi Vo in.-'.?' ' on the vaporizer. ""Also, the chlorine efisch? rs;5" "1V\c:"ri el ruptm?e"~uisc~~slio~'dld~ cc relocated Tor "Improved oner; .`.or r.
HONS 055655
-5
1. Description: Colorless gas '
.
2. formulaNp '
'
' .
3. Cons tangs: Mol. V.'t. P.8.02; M.P. - 210C; B.P. - 195.8C.;
r-- - Density 1.2506 gr/liter at 06C.
*
It. Toxicity: None. In high concentrations it is an asphyxiant
Nitrogen is used for blanketing Aroclor in the blend tanks, surge tanks, finished product tanks, and storage'tanks and on the ,yl
blend tank system before making a 125,l.and 10# Xylene mix. It is he.ndled properly. Nitrogen lines are identified v;lth orange sign with black letters. No Corby connections are present.
The nitrogen is stored in a liquid storage tank ov:ned, operated,
and maintained by Air Products. The tank is protected from over
pressurization by a relief valve set for 125# and a rupture disc
set for 3':2#. Header pressure is controlled- at 38#. There is vv.
alarm for low supply pressure (10#) but none for high pressure.
It is recommended that a high pressure alarm set for 50-v be in-
Btatlefl for "thF'nitrogch heaaer~~to avoid damaging the nttfelen"
pressure' cciritro]- valves. ~
'
"'
Xylene (Code GtOO?)
20# Ortho
-
36?5 Meta
.15# Para
20# Ethyl benzene
.-
Purchased from Shell Petroleum Co.
.
1. Description^ Colorless liquid.
.
2. Wriaulfa:' tf5K.i1 (Ci!v)j>
3. vX'fbfi Ft. 8p* K. to 100* F. depending on composition of
"3 sewers'.
1|. Density: .86*1 g
C. . .
5. TTxplos'fve Range: 1.1 to 7.0# in air.
6. froxYc ffaifard K>(\ingj.
'
~'Kci\`iS~TocT:..... Irritant 1
.
Acute Systemic: Inhalation 1
'
Chronic local: Irritant 1
. Chronic Systemic: Inhalation 1
.
Skin Absorption 1
7. M.A.C,.: 200 PPM in'air.
8. Vira Ifeard: Dangerous v;hcn exposed to heat or flr.>. c: can
"..... react'with' oxidizing materials.
9- Fire fighting: Fos-rr., COp, or dry chemical.
10. Ex^ro^cTrt"!-Ta'xard^ Moderate in vapor form.
.
Xylene is used only to make an Aroclor 125!> end 10# Xyl
:
It is received in 50 gallon steel drums and stored, on r.c''-\
on the cast side of the department. Xylene is o;tr
y
flammable and should be handled and labeled as such. 1>_ is
rccLxm'.ridcd that the Xylene _storar;e arcs bo 1 c.5.d._o'f_ : ;
sT.r.'n~r'~XyTcne - "FI cif.:.:aiiT&'r erected #~
'
MONS 055656
E.. Trichlorobcnzene (Code 60200)
' 1. e.;
!:
. 5-.
6.
Description: Colorless liquid es received in Aroclor Deprrtr?
It is a mixture of 1/2,3 end 1,2,4 TCB and possibly other
isomers.
. .
...
Formula: C5H3CI3
"
' '' ' '
'*
bohstants: Hoi. '/It. l8l.5j M.P. approx. 10cC., B.P. 213C.
Flash Tt. 'about 230 F. (C.C.)
Toxic }iazeril_Rating^
.
" Acute ~lcTcal :"~U
Acute Systemic: Ingestion 2; Inhalation 2
'
Chronic local; causes loss of hair of experimental animals
Chronic Systemic: Ingestion 2; Inhalation 2
Fire Ha sard: Moderate when exposed to heat or flame. When
Readied to"3ecomposition (300C.-l) it emits highly toxic fumes
of chlorides. Can react with oxidizing materials.
7.! Fire fighting^ Water, foam, C02 or dry chemical. TCB is used as ftT>TehaTng agent in the production of Fyranols. it is
' ' handled and stored safely in underground storage tanks ,f3 or ;,"5
8. Handling: TCB is normally received in either 8000 gallon tart!:
cars or'Tn 55 gallon drums. Unloading is handled by a pos.Uiv displacement pump in either case. TCB may also be received by tank truck (4000 gal.). Unloading is then handled cither by gravity or centrifugal pump.
JF.__ Trl Cresyl Phosphate (Code 80180)
.1. Synonyir.s_|_ 0-Tolyl phosphate
2 Bes'crlutlon: Colorless' liquid
Formula :'
) p POij
C'ons Cant:;: Mol, '/It'! 368.36: M.P. -25 to -SO'C. B.P. I10*C.
FlTsh_"i o'i'nt/ l6o* F. (C.C.)
(Toxic 'Hazarl Dating:
' "Scute EoccuL:" 'U
.
.
Acute Systemic: Ingestion 3; Inhalation 2;
Skin Absorption 2.
- Chronic 7,0cel: u"
Chronic Systemic: Ingestion 2, Inhalation 2;
'
; Shin Absorption 2.
7. Fire Hazard: Slight when exposed to heat or flame, vhcr. Kcolcil to df compos5 Cion it emits highly toxic fumes of 0/' 1 . '
of phosphorus; can react with oxidizing agents.
0. F_ire Fighting: '.later, focm, COp or dry chemical. It is i.d.c iri'Vhe production of Pycraul 280,
9; Handlingj TCP is received in either 4000 gallon tank true'.-; Oh"~Iir'5'p 'gallon drums'. ` Unloading 'is handled- by a ceribrif.'g 1 pump for the trailers and a positive displacement pvt.:? for the drome. Trail err. are unloaded directly into -?1 mix v-:' .
0NS 05565?
7Glycldyl Phenyl Ether (PPO) (Code 36100)
.
1. Description: Liquid
.
2. -yormuTin "CgHi; CHp CHOCHp
...
3. 'Constants: M.P. 3,5 C.;' B.P. 2^3'C.
h. Flash"" Point: 175 P. (O.C.)
.
5. ,iroxl'c~Kai:arJ JRa t i ng:
-
Acute'ToceX: U
,
!
Acute Systemic: Ingestion 3> Inhalation 3.
'
' Chronic local: U
Chronic Systemic: U
6. Fire Hazard.:. Moderate; v.iien exposed to heat or flame. Can
react"vffth oxidizing materials; The vapors of glycidyl phenyl
ether normally will not present a hazard at room temperature."
Inhalation of vapors above 6oC. should be avoided. Material
. should be kept from eyes or skin.
7. ' Fire Fighting: Water, foam, COg or dry chemical. When heated -to d"ecompositTon it emits toxic fumes.
8. handling^ Avoid contact with eyes or skin. Wash off with wat . Ifany~ft spilled on the skin.
Glycidnl Phenyl Ether is used os a chlorine scavenger in producing Pyrsnols; Inerteen PPO, 54201KA, and 5llS01. CM. It is stored safely in drums. The material is added to the blend through the suction pipeline of the #2 and ,f3 Mix tank cir culating pumps.
Limp_(Code_3.8800) (Calcium Oxide)-
1. Description:. Fine white - or slightly gray powder, W:oB-.eric
(TYfgohoi `cry's tal s .
2. Formule: CaO
3. Toxic Hazard Rating:
'
`
" ~ AcuteTiocalT Irritant 3; Ingestion 1; Inhalation 3
. Acute Systemic: Ingestion 2; Inhalation 3;
' ' Skin Absorption 0
,-
Chronic local : Irritant 3 Inhalation 2
Chronic Systemic: Ingestion 2, Inhalation 3;
Skin Absorption 0.
A. Toxicology:
Has e caustic reaction and therefore is irritating, to the skin. As t dust it can cause dermatitis and i rri t't'
of the eyes and raucous membranes. It is a general nu
'. type of dust.
5. Firq__H = zardg Kone
HONS 055618
6. K>rplos'ib:)~>iaz;-.rd: Virtually none
7. liarici.il hgn Dust' respirator, adequate protective clothing, in
. eluding rubber costedvgloves, optional rubber full cover r.rr:
end full, cove:' plastic goggles should be used when L: .ndl A1
(dust). Adequate ventilation and dust removal equip r;rt
'
be used in the handling area.
Lime is added to the stills to neutralize any liberated r:
prevent sublimation of the FeClv catalyst. It is ha:,.'1:; in
50;bags .
`
-8
I. AttapulguB Earth (Code 19400)
Attapulgus earth la an inert material and ia handled in bees', drums or buckets. There should be no toxicity involved in handlinc this material, but as a matter of personal cleanliness, it should be washed from the skin or brushed from the clothing after handling it J[t should hot be blown from the clothing or skin with an air hose as this is an unsafe practice. 1
J. Trl-Tetra Chlorobenzene Mix (Code 38500)
Received in tank cars, trailers or "drums. This is a mixture of trichlorobenzene and tetra chlorobenzene. It is similar in properties to TCB and should be handled in the same way. It is stored in #5 or #6 underground storage tanks.
K. l)nox Epoxide (Code 61320)
.
Handled in drums and used in production of'Pyranol A13B3B. purchased from Union Carbide; This material is dicyclo diepoxy carboxylate. Prolonged end repeated contact of liquid or breathing
of vapors or mists may cause delayed and seJJious injury.
Operators should avoid contact of this material with skin or clothing and 6hould avoid inhalation of vapors or mists. In case Of contact the skin should be washed thoroughly with plenty of soap and water and contaminated clothing and shoes should be removed.
h. Dow Corning Pluld (Code 31100)
A defoamer used in Pydraul blends'. It has a flash point in the order of 600' F. and should present no particular hazard in
handling. In the interest of personal cleanliness it should be washed off if it comes in contact with the skin or clothing.
)]. Santolube 70A (Code 821331
Used in Pydraul A-200. Purchased from our Nltro Plant.- This
material chemically is the product of Oleic Acid and Triethylene tetramlne rea.cted in Benzene with Tetra-prophenyl succinic anhydric
and #5 oil. Its exact structure Is unknown. Handled in drums -
should present no haza.rd as long as it is not over heated to de
composition. Should not breathe, fumes. Should be -washed off if in
comes in contect v.-lth the skin.
'
H. Blue A Dye (Code gQ^&Vand AZO Oil Black Dye (Code 20317)
Used only in small quantities in Pydraul A-200 and Pydraul 280. Should present no particular safety hazard. Should be washed off if in contact with the skin.
0. Porocol (Code 46259)
Porocel is an activated be.uxlte ore in 20/60 r.esh form used for packing in the absorbers. It is received in 50# bags end manually dumped into the columns.' Since it is aninert material there should be no toxicity involved in handling, but as a matter of personal cleanliness, it should be washed from the skin or brushed from Un clothing after handling It.
MOMS 055659
- 1. Chemical name: Zinc cUalfcyl dithiophosphates (an oil- diluted
~blend~5 .
2. ' Description: Amber oily liquid
3. . F57muTa':
(RO)g F-S-S 2 Zn
.
. . .. .."ft" is a blond of 50# iso-butyl and 505# primary any],. 4. Flash point: 380 . (C . 0. C . ] 5. Ilecoir,position Tenroe-r-atu- re-: 2i320PoCc>. ((trraapcied) amounts of Ho*S'
6. Toxicity. Moderately toxic and is an eye and skin irritant. Dire; " ' pFiysfcui contact should be avoided. At. high temperatures (see
above) decomposition releases hydrogen sulfide (HpS) a very
poisonous gas. In the presence of water hydrolyzation occurs, ' again generating HgS.
7. Handling: From a safety standpoint I.ubrizol 1360 should not be Heated'above 120C. tc avoid generation of HgS. To maintain
maximum, quality, a temperature of 5A*C. should not bo exceeded.
A drum warmer is used to heat the 1360 prior to pur.ping into ;
. blend. The warmer uses 80# steess (l62*C.'j. It is recor-err'c
that a means be found to insure that the 136o"is"r.ov. heated'aba .
'100*0.
"
"................. ...... ~ .
'
" ....
C{_.__Ferric Chloride (Code 33500)
'
'
W fO P
. Description:. Granular solid
^Formula": "FeClq (Anhydrous)
, Constants : Mol. Ylgt. 166.22, Melting Pt.= sublimes,
solubility in HgO = very soluble with heat rise.
A . TpxJx__HfiZf.iui_ ^.ati_ng:
.
' ~ Acute'Lo~c aT: 'Irritant lj Ingestion 1
Acute Systemic: U
'
. '. Chronic local: Irritant 1
.
Chronic Systemic: U
5. Hire Hazard: There is no fire hazard under normal cond.it1 re'.,
v hut'it will emit toxic fumes at high tenperetu: es.
' 6. Hand ling: Protect the skin with approved protective tOoVn-r.y,
avoid the breathing of FeClq dust, wear approved rc!
with adequate cartridge, and protect the eyes fh ay.u
. goggles. There are no storage regulations;' however, it
' should be stored in a dry place as heat is released u; or
. solution in water and wet ferric chloride will not c--'.
the chlorination reaction.
ft. General Comm-cnts
1. All raw materials'unad ere stable under the present op or:-'. ' . conditions and would remain stable under condition;, cd :...
imaginable equipment failure.
2. Biphenyl, Xylene and glycidal phenyl ether Jiv.rt be hand1 el :/ . . ` flammable liquids under present operating conditions.
3. Hone of the opera ting areas is enclosed in such a way as to permit exposure to toxic nir.tcri s.lc .
A. The operators are knowledgeable and trained to carry cut lb
available emergency procedure in Vue event of a spill.
.
MOMS 055660
- 9a -
R. General Comments (continued)
.
..... . 5>.' Adequate fire control is available in storage areas
-with the exception of biphenyl. It is recommended ' ` that: '
ft. A 500,f dry chemical fire extinguisher be located / near Item A01.
b. Evaluate the need for a monitor nozzle near Item lioi.
c. Evaluate the need for controlled drainage from area
around Item 1)01.
.
RONS 055661
10
HiOCKSS
.
A. Chlorination
.
'
. .
" .
Aroclor Is produced 'oy the botch',<ise and continuous chlorination of
biphenyl or other Aroclors v:3 th snift gas chlorine (delivery pressure
?5' to 30 psig) at a pressure of 2 - k psig. Normal operating tempera
tures ore between 120 end 195cC. Hydrogen chloride gas is liberated
during the reaction and is piped to the muriatic acid and chloro-
sulfonic acid departments. Ferric chloride is a catalyst for the
reaction.
.
The chlorination reaction is exothermic (510 ETU/'Lb. of chlorine) end
is stable. Biphenyl can be chlorinated as fast as the exothermic
.
heat can be removed from the batch and still maintain a batch tempera
ture of 150C. Continuous chlorinator temperatures vary-from 15o'0C.
in f/6, 16'5C. in , l80cC, in 778 to lg5C. in #9. In order to remove
this heal, the reaction mass is continuously circulated at en average
flow rate of 200 - 2?0 gprn from the bottom of the chlorinator up
through an air-cooled heat exchanger (capacity 1,200,000 BTU/iir.) anw'
back into the top of the chlorinator. Maximum batcli chlorinator
chlorine flow rate is 1500 lbs./hr. (pipe size and. supply pressure"
limiting). At 510 BTU/lb. this rate of chlorine flow produces
765,000 BTU/hr. which can be safely removed by the heat exchanger.
The maximum for the continuous chlorinators is 1700#/hr. which is
equivalent to 865,000 BTU/hr.
.. '
Chlorination temperatures are measured at the following points;
" 1. In the center of the batch chlorinators.
2. At-the overflow of the continuous chlorinators.
3. .Just below the chlorine sparger in all chlorinators.
At the discharge of the batch chlorinator circulating pumps.
5. At the discharge of all of the air-cooled heat exchange's.
\
Point 1 is recorded on the 12-point recorder (6638). Point 2 is aia;:, .1 at 200C. Point 3 alarms and shuts off the chlorine flow at 225C. in the batcli chlorinators, and alarms at 20QPC. and shuts off chlorine fin al 20i>pC-. in the continuous chlorinators. Point 1; is recorded on th; Ifpoint recorder (6638). Point 5 is alarmed for low temperature (ir-C'C.).
Kach batcli chlorine tor is protect'.', by a 8" - 20 lb. carbon rupture
disc with a 3" discharge above the to? operating level. Should a
chlorinator rupture disc break any discharged .liquids would be ole
down through the grating onto anyone belo... I_t_ is_reccvrp_:'. :1 c e
,
,1. Flooring be iut_ cn _ the_lcvol__o? tiie d_iscjqttrg_pining_fi'Gu the chlorine toorr"s or
gntedT'- ijn_l
be poonib2c cer'don. ........
HONS 055662
11
A. Chlorination (continued) .
In addition to the rupture system, the batch chlorlnators can be
manually vented. All of the manual vents are tied into a central
header system which is vented to #1 blow tank. This vent system is
adequate.
Since several Sp. Gr. samples are required for control of the batch
Chlorination a fume collection system has been Installed for all five
sampling points as well as for the finished product drumming station.
It is recommended that the fume removal system be extended to the
continuous "chlorlnator area.
" ''
Each continuous Chlorlfratoi' 'is protected by a 3" - **7 psig carbon rupture disc.with a 3" discharge to the ground level. This system is .adequate.
In addition to the rupture system, the continuous chlorinators can
be manually vented. All of the manual vents (3") are tied into a
central header system which is vented to the continuous blow tank.
This system is adequate.
'.
The chlorination system is well controlled. However, it is
recommended that all temperature alarms and automatic cut-offs be
checked .at b moivlh intervals.
'"
Contamination of reactants with water and sulfuric acid will slow down if not completely stop the reaction. The same hazard exists here as it does when the chlorinators are short charged or not chargod at all and chlorine flow continues. Because there is no means to detect chlorine in the off-gas (HC1), it is possible to chlorinate in the Brink demister or HC1 transfer piping. When the
heat from this exothermic reaction raises the temperature to 250C., the chlorine will ignite the iron pipe. To detect the presence of Chlorine in the off-gas header high temperature alarms (17SC. set
pt.) are provided for each batch chlorlnator & high temperature shut downs set for 175C. are also provided. A high temperature alarm
set for 200C. is Installed in the continuous chlorlnator off-gas header.
After use, samples from the continuous chlorlnator system are fed by
gravity into a sample surge which is continuously vented to the blow
tank. This tank is also protected by a combination pressure/vacuem
relief device (See App. IV). The tank is manually heated with 80y
steam 'applied to an internal coil. Temperature and level are indie.at
in the field.
`'
The HC1 gas generated in the chlorinators passes through a shell and . tube, water cooled heat exchanger and a brink demister for removal of'
entrained Aroclor prior to transfer to Dept. 218 and 217. The entrained material is collected in the off-gas storage tank. This
'tank is heated automatically by addition of 30;f steam to external panel coils. Tank level, pressure, and temperature are indicated in the field. The tank is protected with a 3" - 27# carbon rupture disc. The relief line' discharges to the ground level. The tank may also 1 manually vented to the blov; tank through a 3" line.
HONS 055663
12
General Comments on Chlorination
1. Safe handling limits have been established and are observed.
2. There is no provision for disposing of reactants iri an emergency
3. All instruments fail safe.
B. Aeration
The Crude Aroclor is transferred from, the batch ciiloririators to
. #2 blow tank. This is a 2000 gal. steel tank with coils, an ai.<sparger, and an 18" vent line. Here the Aroclor is air blown fo 2 hours to remove any KC1 remaining in the crude,
There are no controls on this tank. 200 lb. steam is used on th
. coils for the batch-made Aroclors 12*l8, 125-1! and 1260. There i-
no danger of operating within the Aroclor flash points es ic,.0 :
this procedure is followed. It is possible, however, that the
operator could drop the wrong batch from' the chlorinator (i.e.
one just charged). This would mean that essentially biphenyl
was being boated with 200,1 steam (388' P = 200*C.). Since bin!
flash point is 2331''., it is recommended that either:
'
1. "A procedure be adopted to prevent drooping the wrong chlo
natr_._ " ............................
" "~
......~
8. H?.. Blow tan!; be groperly equiooed to handle a flewneblo
iTquX<T'.~~" ........... ~........................
' ........
Since there is no level recorder or controller on the to.!.'.;, it possible to overflow the tank and its hot contents on t'ww.o below. I_t_ is recor.v.tr.dc*;'8 that:
1. A_levol_j^ecorder_ bo. jvt_on .2 blew tan!;.
After air blowing, the contents of #2 blow tank arc trv.nsferrvi
to ,fl blow tank where it is continuously fed to the din a
system. 'There is a level indicator but no steam pri\S'~
le-.tor on //I blow tar*. The contents of ;y 1 blow t;:.k c?"s be '
through a spiral heat exchanger for hes.ti>g prior to
the stills. 200-? is the heating nedivti. The preh w.io a ; :
tected on the proiv.et side by a 1C.CV/ rip'. /re disc v.h.':'; '' -
into j?lblow tank. S-:e Ape. IV.
`
Both the j?j and ;? blow tv.r.k vents (if,' ) arctied Into f- drowning jet as well as to the atmosphere.
The crude Aroclor (ill?) Is tror.sfc rred from the cert Tin'.::-:
chlorinators to the intermediate storage tan-;. This is a
15,000 gallon steal ten!; with external plate coils. i:
v.
Aroclor is stored at 1$0C, prior to being further ;>rc: :.. . !.
This tan!; is co.iti nv.ously vented (3") to the KOI d'ow:'.
There is also a 3" combination pressurc/vacuum relief v:-'v : .
protect the- tank sht.-ul,t the vent plug. Tank level Ir.
'-
both at the tank er/d on the control panel. A'high level ' '
sounds at 90% tan!; level. This syutem. is ac'acw.-.tc.
'
HONS 0&566A
The crude Aroclor is aerated continuously as it is being fed to #3 still. The continuous blov; tank is 1000 gelion steel ves.ee which is vented to the drowning jet. 5# air is provided by r. positive displacement air blower through five 2" dip pipes. The venting system for the tank consists of two V lines tied into a 12" line to the drowning jet. Tank level is indicated and, con trolled in the field; however, high (90;5) and low (10m).level alarms sound at the panel in the control room.
The city water booster pump which supplies water for the KC1
drowning jet is alarmed at'the control panel on shutdown to avoid
HC1 fume emissions.
.
The. straight take-over vacuum distillation is carried out in four
still systems: #1 still (1100 gal. steel), #2 still (2200 gal.
eteel), //3 & f'/'l stills (2046 gal. steel) .. Normally j'l, $?. and stills are fed continuously from ,fl blow tank arid #3 at3.11. fed
continuously from the continuous blow tank. However, dua to
piping flexibility any still can be fed from any desired blow
tank. In any event the feed rate is controlled automat leal !.y to
maintain a set level in the still pots. The contents of ,y] t< p?
still are circulated continuously through gas fired furnaces (our
for each st3.ll). These furnaces are uninsulated and are in a.
position where personnel contact is possible.
/.ucorvciu'.:
that either 1. The still furnaces be insulated*etui proueTIy.......
guarded, or 2. A v.'arnThg sign Te placed oh trie' furnaces'. '
Periodically the stills are charged with lime to neutralize
residual HOI. Currently the lime is manually carried to 3
and Stills on the second level (141). it is recommended
that e.n improved lime delivery method be used.
' ''
The contents of f/3 and j"4 stills arc circulated continuously
through therminol fired shell and tube heat exchangers (one for
each still). The entire heating system is adequately insult tv:-,
for personnel protection,
.
'
The therminol is heated in a gas fired furnace which is eqv'; : i
v/ith controls and interlocks specified by the Cii/i Safety and'' Property Protection Section (See Ap? IV).
Vacuum (30 - '50 m:i'- fig absolute) is mounted by six --2 stag-.
condensing steel Worthington ejectors. One jet 3s required for
each still that is operating so there arc- two iiistrllc 1
.
Steam pressure is rc-duc ed. to l6o,;-', but the Jets will uh.c'in . :
of the maximum 2COy available.
'
Each still pot & still receiver is equipped with a runtvre
r
and discharge line (See Appendix IV).' in each esse both tic
rupture disc and discharge line is properly sized end loci''.', i.
Each still is equipped with sufficient'temperature n.casi.
,. t
to insure safe operation. Overheating of the still content.*
causes formation of a tar-like substance, but presents no .- tv
hazard.
'
`'
The level in the #3 & g'l still pots is indicated both, in lb ' o.nd on the control panel. Normal control, point is 50,1 full. 0 alarm sounds on low (1.0;' and high (90,'> ) level conditions.
MONS 055665
Distillation (continued)
;
The level in jJJl still is recorded on the control panel. At
present there is no level indication, other than feed valve
position, for j,'2 still. However, TSD project 6928 - "Install
level recorder on j;2. Still" is scheduled for completion in'early
1969. It is recommended that completion of this project be
expedit?3T~ - --
* " ' '
.
The levels in ,-}'l & 2 (1000 gal. each, monel) receivers are recorded on the control panel. These tanks arc emptied bstchv/iee using a positive displacement pump.
The levels in ;!'3 &
receivers (829 gal. each) are indicated
in the field. An alarm sounds on high (90>i) and low (10;i) level
conditions. Normal set point of 50;$ is controlled by continuous
pump-out using a centrifugal, pump t, level control system.
Temperature in all four receivers is controlled by manual rdditi Of oOft steam to internal coils. Steam heating is rarely needed except for Aroclor 1260 production.
A serious injury was incurred by a pipefitter in December, 1953 when removing the cap from the lima addition noasle on f";l still pot. The accident resulted from pressure build-up on the still
due to Inadequate venting. It _is_rcc_0!:endcd that^alj- th_e actio resulting, from the formal Investigation '(T'-TyiVCPod) ;3eiit be comhTeted a s' sbb'jf as possible on all "four"'stOT'sy:itc::''i:.'.
The specific recommendations made in L-17-20-68 are:
1) Forward flow valves from the stills to the receivers skcvV: remain open at all times except when taking a still sar pit . A sign should be placed at the valve stating this.
S) The jets should be on while charging crude Aroclor and l!:/.
. 3) Change the one inch vent line on the still to a two inch
line. Replace the vacuum indicator with e pressurc/vrcuv.r.
Indicator. Keep vent valve open while removing the still
cap.
~
) Operating Instructions for the still charging erotc should be revised to specifically include the above rev.-..: tions. Operators should be retrained according to ire r v':
instructions.
5) The design of the lime charging port should be evr.lu:.'. cf*>. safe and easy operation.
6) Evaluate the adequacy of the grounding of the still.
HONS 055666
- l'l a -
D.___Porocel Treating
'
'
The distilled Aroclor is transferred from the four still receiver:-. . to the absorption system. The major items of equipment in* the
_ four treating system include the following: #1 & #2 blend tanks
(2000 gal, each, sine & tin lined); #3 & #4 surge tanks (10-'5 gal. each, aluminum); j?l, i/2, #3 & j?4 absorbers (3' diam. .x 15' high, 316 SS) j/'l & /'2 finished product tanks (2000 gal. each, zinc i
tin lined); #3 & #4 finished product tanks (1043 gal. eacli,
aluminum); fj-'l , #2 & #3 polishing filters (316 SS).
. Levels in "frl & #2 blend tanks are indicated in the field. Since
transfers are made into these vessels on a batch basis, this
presents no problem, Temperature is controlled by addition of
city water (manual) or 80j? steam (automatic) to internal coils.
1 The tank temperature is indicated in the field and recorded on
the control panel, This system presents no hazard. Both these
tanks are presently vented to the atmosphere.
Bevels in ,-{'3 & i/4 surge tanks are indicated in the field and on
the control panel. Ki (90;) and Low (1C;,) level conditions are
. alarmed at the control panel. A level of 505* is normally main
tained by balancing the absorber feed rate out of the surge tank
against the still receiver input to the tank. Temooraturc is auto
tactically controlled by addition of city water- or
steam to
internal coils. The tank temperature is indicated in the field
and the temperature of absorber feed stream out of the tan!; is
recorded on the control panel. ' .
.
MONS 055667
15 -
V.__ Porocel Treating (continued)
.
Both surge tanks are normally closed anti nitrogen blanketed.
Tank pressure is controlled between +A" W.C. and +7" W.C. by
self contained pressure control valves. In the event tne pressure
control system fails, the tank is protected by a 2" combination
varec pressure/vacuum relief device set for 6 07.. pressure and
1/8 oz. vacuum (See App. IV). Both these pressure control system;
are adequately sized.
.
The four absorbers arc packed with 5*100" of Porocel (See Section 1 The distilled Aroelor is fed by a centrifugal pump through a flow controller down through the porocel bed. The absorber is protect-; from overpressurization by a 2" - 101!# rupture disc. The relief line discharges at ground level. Temperature in the absorber is automatically controlled by addition of 80# steam to tracers on the outer wall of the vessel. Absorber temperature is indicated in the field.
Aroelor leaving the absorbers passes through the polishing filter.for removal of any porocel particles going forward from the ab
sorber, Pressure on these filters is indicated, in the field, however, there is no pressure relief system. Since (1) the filter arc designed to hold 100#, (2) the filters are only sparingly
traced with 80# steam, and (3) maximum pump pressure on the filter is GO# (normal 15#), it is felt that no pressure relief sysletn is ' required.
After passing through the polishing filters the finished ArocUn-
enters the finished product tanks. Material Is normally stored in
these tanks at 100C. by manual addition of 80# steam to inti .-n:. 1
coils. Temperature of #1 & #8 finished product tanks is record'd
on the' control panel: that of #3 &
finished product tanks :':
indicated in the field.
. ..'Level in H1 i;2 finished product tanks is measure:', by sticking
the tank, as these tanks a rc vented to the atmosphere; Apu:1 r..
project 6939 - "Install Level Measurement on product Tanks" pro.:
continuous field indication of these tank levels. Due to the be;-.
. wise: operation of these tanks, field indication is sufficient.
In the. interest. of iiiproved_pperfttiori8, jotentiel .erode? t _qv; - i ;;p
3rmprov6T:.evi_E', ano'Yebuceb' opejjpvor *6nCacv.' v,n;tip'Arc.clo:;
r_, U
Ts reco:t':eif-re;rThe.t'"co::bleti;;n"o'Vr'tf>Ts~ oroj ecV'Si
tv . '
Level in #3 & #: finished product tanks is indicated in the
-
and on the control 'panel. An alarm will sound v:h<- n a hi j k (5;/) level occurs. Normally, these two tank..; are closed and :::t>.\,.
blanketed. Tne pressure control and relief systems for those
tanks is identical to those explained previously for #3 L
s
. tanks.
.
In _tho interest. of Improved oporatlonr., potential pro duece -)
'iii\brcf.r;;n'5h tT"cn;' reduced .pneretor contTct V.'i.tKfArocg c_r_ ; .../ /
YtYecb::::!:!'d-'d" tHt'a "pro'j'ic't be c'c-v'e.lcroVT" to nitrogen
-.
j.-jpp 'gifev.r and f"; liisThLtr pros net kTenk's
..to"'if -...fin .7
t'fYccT on "#sf.u'g-:gj`!icl_iki ri.ij.hC'd. nrc.cnc t
... '
HONS 055666
. . - 16 - X-/
General Comments on the Process
I. Accidental contamination of reactants will not form undesirable
side products.
8, Process piping and controls are installed so as to prevent improper mixing of chemicals.
3. Sewering of materials would result in no hazards. If biphenyl, xylene, or glycidyl phenyl ether is sewered precautions must be taken to prevent ignition of the flammable liquids.
II. Department guarding conforms to the Illinois Health and Safety Code.
5. Ventilation is adequate to avoid exposure to toxic materials during ' all routine operations.
6. Lighting in the batch chlorlnator area is talow^taiidardj__It_ is
recommended that completion of approved""??!) Project '5377 - Upn.'-'a.i?
T3LKViTfng"System~Tn"5cpt
o"~ be ex'pedrt'eci". ~
.............''
11I. Finished Goods
A.__ Blending and Finished Product Handling
Aroclors are produced in a variety of grades end blends for use
in capacitors, transformers, heat transfer fluids and plasti
cizers. See Appendix 31 for a complete list of the Aroclors
produced and their blends.
'
After.the Aroclor has been poroccl treated in the absorbers and transferred to the finished product tanks, 'it is t> .-.i.'.fcnu < d to an appropriate storage tank.
Aroclor vapors arc toxic in high concentrations as wo 31 as
irritating to the upper respiratory tract. Workers should
not be exposed to vapor levels throughout their work shift
in excess of the threshold limit value (TLV) of 1 mg/;:3 of
air (or about 0.1 ppn). The material can absorb through '
the intact skin and on repeated contact can remove the natu'ul
oils from the skin and cause irritation and/or dermatitis. Ski:,
or eye contact should bo avoided.
.
Aroclor for ales '
Aroclor that is to be sold without an additive is r.or: --lly stored as follows:
a. Aroclor 12*12 - tanks ^'9 and 11 (20,000 gel. each), #.f a: : ' #15 (22,000 gal. each).
' b, Aroclor 12*18 - Storage tanks #7 & #10 (20,000 gal. cr.-h).
c. Aroclor 125*1 - Storage tanks #12 & #13 (22,000 gal. c-eh).
d. Aroclor I860 - Storage tank #l6 (22,000 gal.).
HONS 055669
- 17 -
A. Blending and Finished Product Handling (continued)
All storage tanks are equipped with the proper breather or con servation vents. Storage temperatures (lOO^C.) are not such that grounding or flame arrestors be required.
g. Pyranols
pyranols are used mostly in transformer applications and are made by blending Aroclors with chlorinated benzenes and other
additives. These materials are mixed in 2 mix tank (1*1,500 gal.) and f?3 mix tank (17,000 gal.) and then transferred to finished ' product containers. This system is adequately protected.
Three Pyranols - Inerteen PPO, 5*1201 CM, and 5*1201 KA - use 0.20-;$ Glycidyl
Phenyl Ether as an additive. This material has a flash point of 173 p."
(80C.). It is added to the Aroclor - Trichlorobenzene mix through the
suction side of the circulating pump after laboratory analysis is com
pleted. Storage temperature of the contents in {[2 mix tank is between
90 and 100C. This is above the flash point of the OlycidyJ Phenyl KLi-
but may not be above flash point of the mix. It is recommended that_ a
Semple of Inerteen PPO*. .5*1.201 CM and 5**201 KA oe taken after the lithe;-
Has been addecl arid a. flash point HetemfncST 'tt storage temoeratur es`'arc
withinT$C'>"''o'f~~tTie flash point either:
'
`~
...
1 The tank must be properly equipped to handle a flammable
' ~~H5uT<r~or "
.1
2. TTie storage temperature must be lowered.
.
These materials are circulated through'an 18" filter before transferring
to the finished product containers. This filter is not protected with
a-rupture disc or relief system. It is recommended that an appropriate
relief system be installed on the YTlter, "
' ........
3.' . Pydra.uls
Pydrauls are used mostly as heat transfer mediums. They are made by blending various Aroclor grades with additives. They are mixed
in fil blend tank and stored under proper conditions.
*1. Aroclor 125^ end 10fo Xylene Mix
Xylene has a flash point of 8p - 100?. which classified it very
definitely as a flammable liquid. This mix is made in #1 blend
tank. The xylene is stored in drums and unloaded by use of a dip
pipe put into the drums. The drums are grounded but not adequate'y.
lit is j'ecommended that this grounding system be cheeked and a prouer
one~TnstaYli:3.
. -.
--
During preparation of a xylene mix smoking is permitted only In the control room and Foreman's office and signs are put up in the dtp; ment to that effect. Electrical cigarette lighters are removed f their receptacles. ,fl still is allowed to run as usual by pen.;' of the fire insurance inspector but #2 still furnace is shut o kept off until the batch is complete, any spills cleaned up, closed off arid a gas test of the area made. These provicio' must.
HONS 055670
- 18 -
III. Finished Poods (continued)
It is recommended that:
.
1'. foe flesh point of the Aroclor 185*1 end Xylene mix be determined.
S. ~ Storage temperature be kept as low as possible.
~~
3. Evaluate peecT for vent an<T~fIe.me arrestor on //I Blend TanV.-
M', ' The tank be grounded.
::
5T ' 'Qfbuncf the" 'Xylene drumming facilities and further alter to adhere
i to~Ronsento safety specifications for handling fleimtable
liquids.
----- ------------
5. By-product HOI
a. Synonyms: Muriatic acid, Chlorohydrlc Acid, Hydrogen Chloride.
b. bescrlption: Colorless gas
c. formula? HCl
.
d. Toxic Har.ard Rating:
Scute local: Irritant 3; Ingestion 3, Inhalation 3
Acute Systemic: U
Chronic local: Irritant 2
Chronic Systemic: U
e. M.A.C: 5 ppm in air for 8 hr. day
f. toxicology: Hydrogen chloride is an Irritant to the mucous
membranes of the eyes and respiratory tract. Concentration of
35 ppm causes Irritation of the throat after short exposure.
Concentrations of 50 to 100 ppm are tolerable for 1 hour. More
Beriouo exposures result in pulmonary edema and often laryngeal
spasm. Concentrations of 1000 to 2000 ppm are dangerous even
for brief exposures. Mists of HC1 are considered less harmful
than the anhydrous form since the droplets have no dehydrating
effect.
. This by-product containing a small amount of hydrogen is
collected in a common header and flows to the central HC1 ab
sorption unit for the production of Muriatic Acid in Dept. 210
Of Chlorosulfonic Acid in Dept. 217. If Dept. 218 or 217 is
unable to use all the off-gas, it may be sewered in the Aroclor
department after drowning it with water in a drowning Jet. The
removal of HC1 from the off-gas concentrates the original quantity
of hydrogen and air to a point within the explosive limits;
Therefore, It is recommended that a sufficient quantity of_stea-
be Introduced Into the sc rugger stock to snuff out any Tire TTriV:
could coTicelvagly occur~~at. tne outlet.
""
H, loading Facilities
All loading facilities are adequate with the exception of the tank true';
loading dock. It is recommended that an adjustable loading remo be
installed to compensate for" varying trailer sizes. Approved iTb Project
"Alter"Truc)t~To~eains Dock" encompasses this recommendation
'
MGNS 055671
IV^ _ Safety Equipment
' Stretcher Case on Pole 50 Ft. S.E. of Dept. 5^.
A lst__Flopr
'
. Fire Extinguishers
''
. I. 15ry "Chemical - North of Sprinkler Hor.se
2. Carbon Dioxide snow - West wall at lean-to door.
Shower Location
''
1". Southeast Corner by Water Tank
2. New Area
3. Tank Farm (Alarm on Control Panel)
1. Eye Bath SE corner by water tank
2. Eye Bath New Area 3. Eye Bath Tank Farm
.
Gas_ Mask
T." "North wall of sprinkler house
,
- 2. Outside on west side of repair room.
Scott Air Pak - Outside on west wall of lean-to.
B. 2nd Floor
.
" TlFc'Extinguishers
T. Dfy~CheinIcaT"- West wall at head of stairs.
2. Dry Chemical - West wall at head of stairs.
S_hower location
1. 'SoutlTecFt"Corner in old area..
2. New Area
'
1. Eye Bath 2. Eye Batli New Area.
Eye Bath - Control Boom Gas Masks T. Control Room 2. S.W. Corner Head of Stairs
;Emergency Clothing - Vest Wall
.
C'. Key.7.8nine Floor at j`l ft #2. Still Furnaces
Sf.'fely STiower
'~
Eye Bat!)
P. 3rd Floor ......."1". "S'atei'y Shower- Old Area.
2. Safety Shower New Arc-a
1. Eye Bath Old Area 2. Eye Bath New Area.
HONS 055672
20
R. General Consents cn Safety Equ3.pir.ont e.nd Operations.
1. .
'Sufficient instructions are available to cover shutdown during an emergency situation (steam failure, power failure, water failure, plant disaster). Date of last review - April-1955. It is recommended that r,ore specific procedures be written to cover 'shutdown "during' the 'preparat'ion* 6f~a xylene oTen'JI
2.
It is possible-to trap personnel on the north side if the south and middle part" of the department is contaminated. It is recommended that the installation of an emergency ex ft" on the Tiort^sIHe o~f the oToartma hT'be 'consider ech
3. There are no emergency lighting facilities. It is rccoi.-ur ended
that equipment for emergency lighting be provTdecf. "
" .......
MONS 055673
21
ApraKDix iDefinitions
Aj__ Flash Point
'
.
The lowest temperature at which a flammable liquid will give off a flammable vapor which will burn momentarily. Fire protection
standards recognize the "closed up (c.c.)" flash point. This is determined by testing the material in a closed cup. This tes reveals the lowest temperature at which sufficient vapors esc nut at the surface of the material to flash when an ignition source
is applied. This flash point temperature is the lowest tempera ture at which a stabl-e explosive mixture of the material vapor and air can exist, and is the lower explosive limit expressed as temperature.
: Many manufacturers, trade publications and the Interstate Cou-isor
Commission recognize the "open cup (o.c.)" flash point. This in
determined by testing the material in an open cup. Because so;.,3
. vapor escapes during the test and because the vapor above the
liquid is usually cooler than when the closed cup test is made,
the "open cup" test is as much as fifty or more degrees higher
than the closed cup figure.
.
For this reason most of the flash points listed in this audit ar . by the "closed cup" method. Vie consider a liquid as flammable
when the flash point is ll0F. or lower by the tag closed cup
method (American Standards for testing materials or A.S.T.M.* D^6-5f>) . Materials having flash .points above 1.110 F. should be treated as flammable liquids if they are stored, handled or processed within a temperature range starting at lpF. belt.-.: their f1 ash point and extending to above the auto ignition temperature.
p)__ Ignition..Temoerature (Fire* Point)
The minimum temperature at which ignition will occur by a up),r1
of flame or spark and burning will continue without further heat
or application of flame.
'.
C) Auto Ignition Temperature
The minimum temperature at which the substance nil) .ignite : ; . -
eously upon heating. The degree of danger is deter.1
"y
by the flash point of the liquid, the concent rat ion of vc.p.: . in
the air (whether the*vapor-r.lr mixture is in the explosive
or not) and the possibility of a source of ignition at or
temperature sufficient to cause the mixture' to burst into f 1: .
1) Factory Insurance' Association:
'
Safeguarding flammable liquids (193:!)'
MONS 0S567A
22
p) References (continued)
-
.
i.......2) National Safety Council: Accident Prevention Manual for
. .. Industrial operations. (1955)..
.,
t
- 3) National Fire Protection Association: Standards of the National Board of Fire Underwriters for Storage. Handling
and use of Flammable liquids. (Bulletin #30. 1958).
I|) Commission of Illinois Publication: Rules and Regulations
relating to labeling in the use, Handling and Storage of
Substances Harmful to the Health and Safety of Employees.
. (June 1951).
.
9) Section Vin .of the VI.G.K. Design and Construction Manual ' Safety Guidelines by T. H. Becker, 1938 and 1959.
) Flammable Liquid Handling Precautions
'
1) Flame arrestor on tank vents.
2) Proper tank grounding per Std, E.2.
3) Dip pipe in loading line per P-3-2 Std. 31-
H) Flammable tanks indicated by signs "Flammable".
5) Inerting of the Tank.
.
HONS 055675
A??r-vpix Finished Products
- 23 -
Product
Code
: i Composition
'
Flash Point
1 Boiling
i Point ~ | (760 )
Arcciors
>
1132-1232
811115 Chlorinated ' . Biphenyl 32
S i
Chlorine
i
;
i
1112-1242
011.01 Chlorinated
35ouf.
325"c: j
Biphenyl
c .c.
1140-1240
chlorine srno2 Chlorinated
302UF.
345
!
Biphenyl - 48
c .c.
Chlorine
II54-I254
8HT03 Chlorinated
None
3'65 UC 7"
Biphenyl - 54J
Chlorine
1160-1200-------- 81T7o5-- Chlorinated
Kone "THTcT
Biphenyl - 60%>
Chlorine
iio2Tr2o2
31X707 Ch iorinated Biphenyl - 62^
Kone
390"C.
Chlorine
Inerteen PPO
(l2oO_?Tor 810.92 : 60,1 A roc lor 12o0 plus 40J5
Flash Ft. of
Trichlorouenzene TC3 is
plus 0.20>
Giyc idyl phenyl \
1
? MCher (PPO)
!
34201 KA--------- 1
Yv/j i\roclor 12^,
(1254 ??0)
442C1 CM (1212 P?0)
|
] 30;; Trichloro-
{
1
l benzene and- .20# ; G.'.yc idyl phenyl
; * ether.
611.10 ;
Arocior 12**2
| nr.J. 0.2C',J Glycidyi:.
) Phenyl ether.
*
; l 1 <
s'
1. X.I.Sax - Dangerous Properties oi Industrial Products.
2. T.K.Becker - W.G.X. Plant Flammable Hazardous Materials.
Slight fire hazard when exposed to heat or flane. Can become dangerous when heated to decomposition. Aroclors can emit highly toxic fumes. Ko problem operating temperatures.
!"n
'
Slight fire hazard when exposed to heat or flame. Vapors of Giydicdyi phenyl ether should not be inhaled above 60C. Ko problem at operating temperatures.
Same as above
- 24
, Finished products
1t Product !
-r \ I0 Xylene }
i j
Code OlJL.id!
j
; Ccncosition : 90>.- Arocior | 125H endlog ! Xylene S j
.
1 Flash
pouring Joint 1
* Point
\(7S0 Him) 1
REMARKS
/ Flash ^ ? O-r j fVf,< /ri
i Fire and Explosion Hazard wnen exposed 1 to heat or flame due to presence of
\ "of Xylene ; is 83 "to ; 100 ?.
i i?
j Xylehe.
Pyrji.no 1 A1333B
.Fydraul A-200
' :'
I-yaraui 260 '
i 1 ?tl i \ ' !' f
ri i j
{ j
'j
j
;
! Santicizer \
,79**
5 \ i
Mentors
{
i
j
i.
810.97
j 45^ Arocior
I l?6o plus 55# i tri-tetra ! chlorobenzene j and 0.125# Unox ! Epoxide.
) j
j ;
r ! 1 1 1 j
810.96 ; 33-1/3/* Arocior \ Flash
[ 12*'2. 66-2/3% | Arocior 12*lS
! j
1 \
1 plus minor amounts!
\ of Santolubc 70. \ 1 Lubrizol 13^0,DCF,t
J i
i
j A2C-01I Black c-ye j
? and blue A dye. *
i
bli.I9" ! Arocior 12oO,
j Flash
| Arocior X2*iS plus i Pt. of
j 5
, 21.8# Tricresyl Arocior
i phosphate ana
: 1248
` minor amounts of 1
<s 3<
< Santolube 70
j 382'F.
j
j{
DCF and
]
i Blue A eye.
!
611.04 ! 50/j Arocior 1246 1 Flash ?t. 5 --
i and 50# Arocior of Arocior;
; 1260.
; '1248 is ;
332"F. f
020.00 ; Buiil oettoras \ from Arcelor *
$
j Process-
.
5 7
iFire and explosion hazard when exposed - to heat or flame. Should avoid pro>longed breathing of fumes. iXo problem at operating temperatures .
$
1 Slight fire hazard when exposed to hear
ior flame. Can become dangerous when
Sheated to decomposition as it will then
.[emit highly toxic fumes. Xo problems
iat temperature handled in the dept.
i i
,
|
jSame as above.
1 ,* S
5
?' \t ,
' i ' ,
i Same as above.
'
!No problem at operating temperatures .
j
j These materials are extremely hot a.n.
[must be handled carefully. Fumes must j not be inhaled. Present drum area i.; [ enclosed anc should be adequate. Fume i respirator should be worn.
ru'i'i.WiA
O " Dept- 246 - Group Equipment (catch Plant)
Kcuip. Kur.bcr
(Iter. Nur.bcr)
Service
21-2210 ! .Biphenyl (102) j Feed Tank
' r
< (Capacity Jacket. J iT-.e Gallor:3 : Relief ;
10'6" xf 23,000 T Coils ( Ko Jacket '
Breather j 71ase | Vent________ - Arrestor a
Ko
Belief or ;
-
Rupture Disc : Grounded
Kone
l Ko
21-0767 (133)
3iphenyl
21-3261 (105)
Chlorinator #1 i
Yes l
Jacket ; over lower) half of ; tank. 90# ? sot on re-i lief valve!
li" \
Vented to ;
Biphenyl j
Stg. Tk. I
s
2" Valved- j Ko
line headed
with the !
chlor. to \
#1 blow i,
tank.
i
Rupture. Disc @ 20# - 3" line OK
KO
'21-3245 (105.)
#2
Ko Ko
.21-3251 (107)
21-1283 (103)
Chlorinator #3 .
Chlorinator #4 ;
KO K0 Ko 5 Ko
21-1432 (109)
Chlorinator
//5
'
Ko
38-5'-07 Chlorine \
Vher.
No
No
(116)
Vaporizer
internal
(In par <
pressure
allel with
50# steam >
new Vapor..
auto. shut;
Iter. #590).
off.
\
:i ;
71-2036 ; Blow Tank
Coils - no!) 18" vent ! Ko
(12e) ; #2
Jacket ` line to . ): ,
handle air);
; blowing.
Ko Ko
No Ko
No
09SSO
Dept. 245
Number f T-
1 ! Service
' Size
Capacity ; Jacket Cal. S Relief
20-0CU3 (130)
27-0045 (132 )
20-0062 (133)
1 Still #1 ]
j Furnace 1 #1 1 j Still #2 !' s
| 6-' X 5'6" 1100 N0 Jacket
tj I
j 3/16" X
i 3'9" x ! 4 >ioi"
600,ooq BTU ' J .| r
| 6' x
2200 Gal.;
1 11'10" .
i
it .
"1
ft
.'-;3-0770 i Condenser i 12" D x
>136)
i #1
5-
33-1378 (137:)
21-0771 (133) .
i Condenser j #2
! Receiver S #1
i 12" D X ;1 5'
{ 516n x \ 5!6"
1000
i No i 1 j No 1 j
N'o Jacket
21-1377 (139)
1 Receiver i; i'p
i 5'6" x !t 5-6"
1000 j i
21-0779 1 31end Tnk. : 7' XT'
2000 N'o Jacket
(1*2) j #1
21-1399 (H3)
1 j Blend 1 Jtr> \
Tnk.
1
I
I7'x
7'
2000
\
15-0233 j Sparkler
38"
!
i i
I
| ft
1 i
'
j
| Yes
(H3)
21-07-30 F.'n. Prod
7 ' *' 7T 2000 j
Breather Vent
No Vacuum
6" Vent I Stacrt vO | roof
Ii No i
! j No
! No
Flame Arrestor
No
' No
Relief or Ruoture Disc
-
30# Ruoture Disc of 4" Dine
No
Grounded No
No
No
No
No
30# Rupture Disc l 4"
Line
. No
No No
-
No No
No No
"
2" line around No
Bldg, dischg.
.
2 ft. from ,
ground. ' '
2" thru lean-, No
to tees into . #1 vent.
No
. No
No ti
No '
' No *
no
- * No
"
No *
No j ! . ; No
.
2" (manifold dl ochg. above control roor.) i 1;
HONS 0 5 5 6 7 9
Pl-lv-CO Fin.^rod
7' x 7' ! 20C0
2" conscr/a-
tion vent
j
089SS0 SNOW
:
aaacit'
< Sire Scc.1 lone
21-1310 i Sag. Tank ) 10' x 26';
(152) i #5 TC3
1
j
21-3526 i ;73 Mix Th. 512'6" x (
(154) j pyranol
> 22' i
15,000 \<
20,000
21-2404 Stg. Tank '(13' x 20 20,000
(156) j #7 1243 :
i|
21-0750 (167)
1
\
Blow Tank 7?1 .
:i- 7'
X
7'
*(j
21-0321 1 frl Mix
<.
1
X 10'-
(159) j Pydraul
*
j
2000 12500
?; s 4
21-2621 ; ,#2 Mix (164): 1
j
5j 10'6" X 2,3' 14580 J; /' i
2.1-1396 (186)(185
)
#2) \
Catch
21-0756 j #lj Pots
14'6" x 5'6" . J*-6 x 5'S"1 VA
' *
33-5328 ft Air Cooled i 1.2
38-5564 - Heat
IiTU
?. s
* '
67 l Exchanger
i:
21-0348 (162)
?l_h0v4 (U7)
l Stg.Tank ;8'x25'6" ; J #6 TCB/TTCB;
; Stg.Tank f 7/9 1242
>12'6':x 22? V' ' i
9,500
4
20,000
;I
2i-io55 ; #10 1243 (llo) \
*i 20,000 'i
21-4036 ; #11 1242
? . 20,000
(119) |
'
- 2? -
Dent. 24$
, .TpnVo-)'. Heiief No
No
No
'i
J Breather
; Vent
\ 2 oz.
%
i i
\i
ft
3" Traced Insulated
3s
| : 2" Vent
i*
[i r? riarr.e Arrestor y
No
It
<ft *
i?
It
No No No No No
No No No No
1 18" Vent 5 ir 1
>
2" Vent i No
1s 3" traced 5 .
? $ No
i?
It It
s s. ?j*
J
C
3 i" - 3 ft.
From Ground >
i Level
V!
ji 3" Conserv.
| Vent
oz
. No NO
1! ' No
V 3" Conserv.- ? _ No ? Vent + oz 5
f 6
\
j
<j i
^5 3 5
J
2
2
.
i i;
?
/ ||
i r,
Xt Belief or * Kuovure Disc Arcaneed
No 7 No
ft n 11 ri 11
11 ^` * > .
(t; it t;
.. "
1
Jj ti -
| it
'}
i it
5
tt
`
_
NO ' : No
i
K * No
s ij No
y
No ' '*
1 1
No *
- ,~ ' * f:
No No
Dept. 246 (ISOO Expansion)'
j
( TJ-
! Service
21-5229 | 3iphenyl (401) j Sts-Tani:
> |
1`
-5
; Sir e 2 Gallons :
i 25'
30 i no,oco; ;< i
Jacket belief
Coil 40,? Set
- ' 3 :
1
Breather 5 Flame
l Relief or \
7 Vent
i Arrestor P Ruotvre Disci Grounded
\ Yes. 6" ;6" Steam i- " Protec toseal'J 2 Grounds
Steam Jack- (Jacketed i Belief Cover - no ru
eted.
(Vent with 5 on manway- ? south sise
iflane
*
?
(arrestors. ;j
*i
21-5230 j Eiohenyl (403) | Mix Tank
)
21-5232 I #6 Chlor (4o6) i inator
\j ,33-5333 i #6 Chlor.
(403) | Cooler
21-5233 | f?T Chlor. (410) | Cooler
( 5'6" x 6'vg" 1,272) Coil
S Yes. 4" SYes. Jacketpd
No
| No
Steam
<50# set on t
l
`i }
i 4' x 20'' 3 5V !i
; <
Jacketed
<F.A. Jacket.)
*
1,750 l 4
Shell Trac ed
No. (Vented 1 to off gas 5
No
I 3" Rupture No 5 Disc - 47 lbs];
i No Jacket system)
1
i
ij "* ' ^ Ko
> No
H . * f-
;
1 No ' ?
No
,( No
; 4' x 20' 1,750 j Shell
r . C Traced
;
'l
' Jo Jacket
? No (Vented 1
jJV|f
to off gas system) '
` 1
Ko
} 3" Rupture a Ko J Disc - 47 Ibs( i .i
' -
T99SS0 SNOW
0
:y !-0
38-5869 > (412) j Cooler
21-5234 l #8 Chlor. (414) j
J
38-5890 = #3 Chlor. (416) : Cooler
>__ 5
1 U' X 20' 1
J__
(
---- 1,750 __
!j Ko ` *
; ii Shell
Traced No Jacket
Z No i
S| No f
No (Vented to off gas - system) 51 No <s
I
? '] t
'i i
Xo . ' - j
No
\ No
`* ' KO -
-
c
3 3" Rupture 5 Ko
lr.
Disc
- 47 Ibsi ';
Ko f : .1
No
'i No ' . j
'
21-5235 5 #9 Chlor. (413) j
:U' x 20'. s- 1,750 ) Shell
1 No (Vented :! No
i! j Traced [1 To off gas ? .
4 * * No Jacket !< system)
.
;! 3" Rupture ; No . v. Disc - 47 Lbsi
. j
33-5391 i #9 Chlor. :__ (420) . Cooler
4__; ?
3 Ko -
Ko f
ii No . '
0 . no
;; Ko
. <
MONS 055682
- 25
b;cuip. ; Kx;r.bcr [
i
?1-5236 1 (422) j
21-523? (tail)
Service Blow Tank
Xntermed. Stg.Tk.
:1 - . J
*
S'~e
> Capacity] Jacket Gallons ; Relief
j 4' x 10' j 1,000 \ No
iV
i ilT x-22'.i 15*000 ; Coils I }\
38-5392.!
(427) .j
PI-5238 ) (^29) j
i
1 21-5269 I (435)
21-5239 ( (502) j
i 3 38-5393 ; (504) |
38-5895 s (506). j
Off Gas Condenser
5 -S
20"
x
i-- 3*
i *. \ .
21i ;
Off Gas ! 7'6" X 8^9"3,o3o 5
StG-Tank ? J
ft.
* ;a
Sample
5 3'6" x
325 |
Surge Tank? v j
#3 still\ 78" X 93-
Pot V
<
; V. *i li
2,046 |
5 . s 5
#3 Still s -- Keat Exch.;
Vapor Cond:
^'
__ -j
Jl
j; u '
21-52415 #3
5 5'.x5'3" )
(508) j Receiver.
Tank
3
829
|
21-5240 j Pot
78" x 93?.. 2,oU6 ^
No Nc
No
NO ' No No Coil
No
'3-5396 ^ Cor.uenser
NO
Dept. 246 (1800 Expansion)
; Breather : Vent
i-
it
!
i ft
5
l Flaaie
: Relief or *
-
* Arrestor i Ruoture Disc > Grounded
\ Vented to !No 4 jjrowing Jet
?
'
\ No
$ -?
' 5 No
$ *
3" Vac-Press No 6 os. closes 4 oz. opens;
No (Vented to? One nBloawm TTVk.V);]` ''ETTafts'itti \Side.
No ; No ' 35
i No
l KO
No. 5 No 5
3" Rupture
Disc 34# Burst.
5 No
( 5
2" Vac-Pres| 6 02. press* No
4 oz. Vac. 5
.
no.
I r; no
|
No 5 No 5
3" Rupture-
Disc - 20# Burst.
\ No*
*--
5
--* 5 No
% No '
{ No | l No
I No
ji No ' >
. ^' [; Ko
l} No
. 053
Relief Valve * No 125# Press, v
3" Rupture Disc. .104# Burst.
3 Rupture Disc 20# Burst.
l; No L)!
i.
No
Relief Valve) No125#. Press. -
- 30 -
Dept. 246 (1800 Expansion)
Ecuap. j u-oer i (iter. ^ :
21-5242 ! (515)
Service
#4 Still Hoc. Tank
is
1 .* 5
*i
> ! Size
;Capacity;.-Packetj3reather ; Gallons \ Reli'af 5 .ZSSS______
; 5' :
5'3';'
829 ? Coil
| No
; Plate
I:
-- Arrestor 'j
;No '5 i 5
Relief or 5 Runtnre Disc' Grounded
3 Rupture Disc. iOij
Burst.
5 No ;; ;
21-525?
I. ? #3 Catch ;3'6"x4'3"j
325
No
No
? No * No
(523) Pot i '
I 5:
NO
21-5258 #4 Catch \? 3'6"x4'3| 325
No
No
No
(524)
?ot '> ;<
8-5894 526)
#4 Still ( -- Keat Exch.
NO No. 5 No
NO No
No No
21-5259 #3 Surge
(530)
Tank
5'x6'9" 5 1,045
Coil
21-5243 i -#1 (532) 1 Absorber
S * 36"x15' (Packed! Shell
. <5g00 1`os! Packed
jjof Poroc-il)
sri21-'
(5
#3 Finishes 5'x6'9" ; 1,045 ; Coil
Product Tk;
:J i;
fi
; ;.
1 21-5260i #4
5' 5'x6'9" ? 1,045
(537) 3 Surge Tk. ) |
i .?
Coil
2" press- jNo
Vac relief V
6 oz. -
Ij
1/2 oz. N2
31anket.
No : No
: 2'-' press- No ; vac. relief j :6 oz. - 1/2 oz. ; N2 Blanket ? ,
; 2" Press-Vac';. I Relief 6 oz.f, i 1/2.07.. N2 i) | Blanket.
No
No No
' .|
2" Rupture * No
disc, 140 lbs),
byrst. '
0
'i
No '
No.
No No
055683
21-r'244 ; (533) ;
#2 Absorbed- 36!,x15'
j (Packed' :
H'itb 5500 lbs. of : i porocel) -
Shell_ Traced
' No
f NO
< I.
2" Rupture disc. 140# burst.
No
ijquip.
Dent. 246 (iSOO Expansion)
l'*.-v.r.ocr.j_
vie:
; Capacity; Jacket Size (Gallons!__Relief
21-5245; #3 Absorber 536" x 15' 3 (Pac'xedj
(540) !
; with 59^0
i
,.
of !
1 ? -iporocel)'
j
j-
,i
i
Shell Traced
21-5247; #4 Finished:5.'x6'9" 5
(542) : Product Tk.:
I
1,045 5 ?
Coil
! S?
} Breather i Vent
No
Flame Arrestor
t! No
2" Press-Vac.
Relief. i 6 oz. - . ? -
1/2 oz. N25 Blanket 3f
No
21-5246; #4 Absorber 36"xl5' .((Packed
S----h--e---ll
^545) ;
! '(v.-ith 5900# Traced
/I
.;
jof Por'occl)
No
; No
Rupture Disc` Grounded
2" Rupture disc. 140# burst.
No
No No
2" Rupture disc - 140# burst.
No `
21-5248, #14 Finishedl2'6"x24' ) 22,000 |
(55S) i Product Stg.-
; Tank 1
J i
*v
! i 5
'
i
21-5249; #15 Finished! i2'6">:24;; 22,000 ;
(559) 5 Product Stg/
(Tank.
3
) ij !s
21-5250) #12 Finished' 12'6"x24'i 22,000 |
(560) jj ProductStg.-
;
!;
. i Tank
'
;
.21-5254 #16 Finished 12'6"x24 V 22,000 |
(561) Product Stgi
\ ;;
' . ; Tank
j
5
s ? *s
(
21-5252; #13 Finished; 12'6''x24j, 22,000 ::
(562) j Product Stg.(
< f,
' Task
1
) '
lo-'lSyi Thcrminol .614"xl6167 --
(325) Fouler
:
;
:)
Coil
t Vac. 6 oz. 5 ( 1/2 oz. Ng t
ii 31anket .
l
No
No No 'No
No.
i' ? Ho
2 - North 3: South Side.
ft
ft
t^
It
No
HONS 055684
HONS 0 5 5 6 8 5
Equir. J V.vrii-cT i
Nun'ccr) i
Service
2-1-5253 (556)
Therminolf Surge Tan'iC
15-0733
(590)
,i.
(Installer!
Mist
$
Eliminator)
cor Clc
in parallel
with existing
unit Item
#115) !
!
5\
i
5 W
G2T0V.
- 33 APPENDIX IV
Dept. 2*46 - Safety Devices Relief Valve, Rupture Disc, and Interlocks
*1 Continuous Chlorinators
3" Rupture Disc. *17 lbs. Bursting Pressure. j^l-Jl3594
.'
;
Chlorinators 6-9 Rupture Disc dischar
at ground level directly south of Bio
Tank.
!
FeCl-j Mix Tank Item"*103 .
Chlorinators 6-9 has a chlorine valve
interlocked to both pump and high
9temperature at Sparger `(205cC.) *: --
S.l ' Z
-
^/
Jacketed Flame Arrestor..
This contains a Relief 1/2" valve to (Steam) Jacket. Discharges at 50 psi
1:13332
Intermediate Storage ' (Item *12*4)
3" Combination vacuum-pressure vent pressure of 6ok closes". Vacuum of *1 Oil open. 50.6_22
*) -Conti r.u.ous Chlorinator Fans These are interlocked to temperature.
Items *103, *4.12, *416, *420
V,'il.l not start unless 120"C. in
chlorinator.
Off Gas Stg. Tk. (Item *(?9) Sample Surge Tk. (Item *435)
3" Ruoture disc 2Y,y bursting oressuro 51-135S3.
2" Combination pressure vacuum relic:' valve 6 02. pressure, *1 oz. vacuum 5-168*41.
Hif-i Stg. Tk. (Item *401)
1" pressure relief valve. Set at located in 8C,y steam line to tracers.
2*1" "Protectoseal" relief cove
6" Jacketed fier.e arrestor. S:.o.-.v t jacket reduced to lG I'flO.
HONS 055686
" ' - 34 -
''
. Dept. 246 - Safety Device's
. _ Belief valve, Rupture Disc and Interlocks
<
t,!3 & f!'1' Still Pots Items $02 & 111
113 Sc 4 Condensers 'Items 50S & 513 #3 & 4 Receivers Items- 508 Sc 515
i?3 Sc 4 Surge Tanks Items 530 Sc 53?
4`3 Sc 4 Finished Product Tanks
Items 534 Sc 542
'
'
14, 15 Sc 16 Finished Product Storage Tanks Items 560, 56?, 558, 558 Sc 5Gl
|?1, 2, 3 Sc 4 Absorbers Items 532, 539. 54o Sc 5'45
Therminol Furnace Heater Item 585
Tjierminol surge tank Itei.i 586
HONS 055681
.3" Rupture Disc. 20 lbs. Bursting Pressure
'
- -- 51-13593 Still #3 BTscharges So. of Still Ground
Level. Still #4 discharges No. of Still
Ground Level.
'
1/2" Relief Valve 125ir Relief pressure
7-83333
.
(1) 3" Rupture Disc 104# Bursting Pressure
..
51-13591
'(2) .
An electrically operated Solenoid
valve is interlocked in this system. Pump failure will activate the solenoid to close the auto, valve 1: the forward flow line.
The. solenoid is also activated when the receiver reaches a low level. . low level is 20#. Both receivers discharge at the. same respective
locations as #3 & #4 Stills,
.2" Combination Relief Device 6 oz. pressure - 1/2 oz. vacuum
2" Combination Relief device. 6 oz. pressure - 1/2 oz. vacuum
3" Combination Relief Device 6 oz. pressure - 1/2 oz. vacuum
2" Rupture Disc
.
104f" Bursting Pressure '5.1.-1.35.9'
All absorbers discharge a't gro. ' - r.
directly below absc-rbers.
(1) Pur.o failure, (20C 0PM).
(2) Less than 10-r gas pressure, 0 :. r then 30# ges pressure. Doth shu'
down the system..
(3) The furnace has a purple peeper t watch the pilot flame.
(4) A timer is used to keep furn
--
the low fire settin;-, fr>- VO : '
before the high fire setting c. ' .
activated. (auto valve V. ...
(5) A purge system. is in th V !
'
The nil.ot cm not be ifo
-
r.
r- rm ht: n
. 1'' ' '
/1/68
tern
- .35
DEPT.' 246 - SAFETY DEVICES RELIEF VALVES, RUPTURE DISCS, AND INTERLOCKS
Equipment Location
Description
5 chlorinators items 105 thru 109
Rupture disc, carbon, 8 inch,
20 P.SIG bursting pressure 70F.
Storeroom code 51-13466 "
'
#1, 2, 3 and 4 chlorinator rupture disc
discharges are 3" and discharge on top level.
#5 chlorinator rupture disc discharge in
3" and discharges on 1st level, 14" abov
floor.'
'
5 chlorinator jackets Items 105 thru 109
80# steam, no regulator. Pressure relief valve set for SO;-. Storeroom code 04-3l632.
#\ still item 130
Rupture disc with vacuum support 8 inch, monel, bursting pressure 3' PSIG @ 72F. Storeroom code 51-13:
Rupture disc discharge is 6", and is
directed West above roof of lean-to, 4th
level.
.
i2 still item 133
Rupture disc with vacuum support,
8", monel, bursting pressure 31 PST @ 72F. Storerbom code 51-13465.
Chlorine Vaporizer Item 116
Rupture disc discharge is 4" and is directed east above roof <?f control roc 3rd level.
Consolidated bronze safety valve type 1471 (l" NPT serwd.) 'East end top of vaporizer, pressure relief . .Cl2 side Set for 50 PSI.
Chlorine Vaporizer Item 116
Rupture disc burst 50 PSI 100y Model 1A. Storeroom Code 51-13416
Chlorine Vaporizer Item 116
Sparkler press 36" Item 145
East end, bottom of vaporizer, mercold pressure switch set at 40 PSI, (w; ' turn off steam i's behind S.E. pane' board in control room.
Jacket tested for 100 PSI. 80# si regulated to 20#. Storeroom code pressure relief valve - 04~31o52
HONS 055688
- 36 -
Equipment Location Biphenyl Head Tank Jacket Item 103
Biphenyl storage Item 102 Preheater for stills
5 Chlorinators Item 103 thru 109
5 Chlorinators Item 105 thru 109
Description
Jacket tested for 105# hydrostatic
pressure. Using 80# steam regu lated to too//. Storeroom code for pressure relief valve O-'t-31632.
High temperature alarm read from 12 point recorder 29-6638.
Designed for 220 PSI, tested for
330 PSI. 2" carbon rupture disc, set for 100 PSI 350F. (Hot a Special Order.) Spared in Dept. Stocked locally.
There are 2 alarms and 2 interlock::, on
each chlorTnatov: (1) A high temperature thermo couple Is in the KC1 line
on top of each chlorinator. Alarm is set at 160C.
Chlorine cut-off point is 175"C.
(2) A high temperature interlock
(chlorine shutdown) end alen are activated at 22y*C. The temperature is sensed ft lb? bottom of the chlor.in.- tor -
the chlorine sparger, aryl i r. indicated on individual board indicators.
HONS 055689
.
. - 37 "
'
.t
_
. DEPT. 2K6 SAFETY DEVICE INSPECT ION METHOD ft: FREQUENCY RELIEF VALVES, RUPTURE DISCS , AND INTERLOCKS
Item 1.
2. 3- ' i). 5. 6. 7. 8. y. 10, 13 .''' 12.
33
Peso rijjtion '
Frequency*
111 thru jif? Chlorinator rupture
discs
. 12 months
#1 thru 11? chlorinator Jacket relief valves
12 months
111 still rupture disc
12 months
i`2 still rupture disc
12 months
Chlorine vaporizer rupture disc Chlorine vaporizer relief valve
12 months 12 months
Chlorine vaporizer Mereoid pressure switch
12 months .
36" press jacket relief valve
' 12 months
Biphenyl head tank Jacket relief valve
. 12 months
Biphenyl storage tank high temperature alarm
6 months _
Preheater rupture disc
12. months
111 thru if5 chlorinator high temperature off gas alarm
6 months
tl thru S chlorir.ator h5.gh temperature off gas shutdown
6 months
Method
Inspect discharge line thru.cross Replace
Replace Replace Rep.lace if necessci Replace Manual chock
Replace
Manual check manual check
Rcplc.cc if nee css a Manual check
Manual check
j, ' ,
* in uciidition to visual inspection-during monthly hav. arc! inspection.
ONS 055690
.1 33 -
.'APPENDIX V
' jjepty 246 - Grounding List
Location of Grounds on Hew Expansion.
On Steel Structure: (All on ground . level)
Nitrogen Storage:
Located at South Side 1st, 3rd, 5th Vertical Support. North Side End, 4th, 6th Vertical Supoort.
I One ground located East side on the North Suppor
Biphenyl Storage (Vertical): Tv:o grounds one on North side - Other on South side.
Tank Farm: #9 Tank:
#10 Tank: #11 Tank:
#12 Tank:
#13 Tank: ' #14 Tank:
' #15 Tank: : #16 Tank:
Hone (Grounded thru Bolts in Concrete
Hone (
"
None (
"
Two Grounds Located at North Side Sc South Side
Two Grounds Located at North Side Sc South Side
Two Grounds Located at North Side t- South Side
Two Grounds Located at North Side & South Side
Two. Grounds Located at North Side Sc South Side
Intermediate Storage: One Ground Located at West Side
Hew Office Sc MCC:
Tv.'O Grounds, Located 1 Foot Under Ground Level, at Foundation.
Loading Lock #5:
One.Ground Located Northwest Support.
Loading Bock #5:
One Ground located northeast Support.
HONS 055691
Sauget, Illinois
January 28, 1970
cc: : ; .
G. L. Pra ts R. M, InlC..". T. W. Dn.i Ion D. w. Jack sen, W. A. Kuhn - G J. J. I.uectsn C. B. Killiums
iStOKOCLOH GKO'JP OBJECTIVES
I. SAFETY
A. Ooj'ectives
- __
'
1. No serious injuries for Dept. 246 and maintenance
personnel in 246 area.
2. No disabling injuries for Dept. 246 and maintenance
personnel in 24o area.
3. 0.75 minor injuries per nan per year for Dept. 246
. personnel.
4. Three minor injuries per year for all maintenance
personnel while in Dept. 246.
'
E. Actions
_
1. Evaluate need for sight glasses
where they exist in preparation for
plant wide change, to pres-Sure
glasses.
2. Supply department data to comply
with VIGK Procedure 1,-40.
3. Doe safety device and interloci:
system inspection frequency
developed for department.
4. Install addition to fume removal
system.
5. Issue Quarterly status for Safety
Audit.
.
6. Eveluetfr gas mask location/
relocation to control room.
7. Install re.rro for lime delivery to
2nd. level.
8. Install concrete pad for fork lift
lime delivery.
9. Make safety eve? rati on of drum
. Icanto.
10. Davie:/ grounding of Equipr.srit
a. List equip.
to bo grounded
' b. Implement r round* ng
11. Establish equipment preventive
weinienenee 'procedure(SIAM).
12. Extend elevator to 2J foot level.
13. KiOcn ./aIk:.ay around fume sc.iv.bbsr. I'l. Complete repoirs on CNA explosion
damage.
15- Ins.;el! a.lavr in dv'-.ning station.
EDO Rc'''.rr-.:\c-.5M ] 47T T.*>0/r? i oq .
4/1 ri-cdv..:fio.\
Con- Drain;iion
tin uing 7/1 TOD
4/16 I re?.. : t;
4/1 Safety/ Product;.- /
2/1 Kaintc:v ;
7/1
1/1 Pooh
'-
4/1 2/1
4/1 1/1
V ' /
i:.i: . -A. ;^ m.
5r //1*1
j-!.v. V.r ill o .
J; n r. -..
;
HONS 055692
-k
XX. QUALITY
...
A. Objectives
1. Maintain .196 Aroclor Quality Level
19S9
a. ReeiGtivity(l09 OHM-CM)
b. Power Factor( at 60 CY) c,, TCC(PFM)
12*12
/. ?
3021 2.09
o./A 0.15
129'! 19783 0.61
0.52
Customer. Complaints: <;0.3/100 shipments
(1969 Actual: 0.51/100 shipments)
3. Improve reproduceability of electrriiceaal aann:alysis
.. Actions
'
.
EDO Resnonsib.Uic
1. Resolve status of new electrical
r/1 Laboratory" "
analysis(dependent on lab air
scrubber). 2. Determine reasons for and correct
* TED
discrepancies between lab analysis
and in-line instrument indications
' of electrical properties.
3. Define effects of storage retention.
* TSD
5. Define quality degradation during
* TSD '
loading; need for loading through
Porocel.
5. Evaluate need for isolated area for
* Laboratory
Aroclor analytical work.
6. Improve maintenance of Aroclor quality *
Production
in sampling bottles. (Dependent on
Action Ko.l also).
a. Sulfur treated bottles
b. Bottles at constant temperature 7. Install facilities to blow the mix
9/1 Product! Oil
tanks viith nitrogen.
.
8. Op cretin?, procedures changed to unload Pyranol cars with nitrogen.
Con- Production tin
ulrig
9. Install weather protection at loading 1/1 Cecil. Per t;;.
docks. 10. Alter piping to locate polishing
6/1 Prednetic.ii
filters ahead of absorbers in -!3 and
fik still systems. 11. Relocate gear meters to point in
6/1 product! on
' process where maintenance costs will
be decreased.
12. Complete tank car inspection procedure. Con- Pi-cv
tin
u i rig
13. Monitor quality of product end
3/1 TED/: r: 1.
chlorine during change to Ag Grade KOI.
1*1. Provide sales sample with necessary
A/1 Prod.
information for proper handling of
Aroclor products.
Dependent on accomplishment of Objective 3-
MONS 055693
J
XXI. CAPACITY
.
A. Objectives
1. Meet 170 sales forecast of 42K pounds Aroslors and 12H pounds Aroclor blends.
B. Actions
1. Make Brodiraatic meters operable.
2. Publish MIP and issue status
periodically.
3. Demonstrate maximum capacity.
4. Insulate #7 storage tank.
5- Evaluate need for improved mixing
facilities.
-
6. Evaluate need for increased loading
rate of Pyranols.
7. Demonstrate use of filter in xylene
mix drumming line.
EDC Eesocnsibil* 771 FmT. .......... 2/1 TSD
Qrt. Prod. 5/1 TSD 8/1 Prod./TSD
4/1 Production
2/1 Production
IV. COST
.
7TTObjectives
1. No negative variance from 1970 cost standard.
2. Mechanical expense not to exceed -1970 budget.
. 3. Overtime for Dept. 2{lG personnel - otf.
4. Absenteeism for Dept. 246 - 3
5. Mechanical overtime 4$j
B. Actions
1. Complete and implement preventive
maintenance list.
2. Install new pumps on 7/2 and "3 mix
tanks.
'
Respcn? V. f.y. 5 EaTnVr/i'rVcTI
6/3 Main t.
3- Annual physical inspection of we.rchouse stock to reduce repackaging
6/1 Production
costs.
Bet drum inventory levels agreed on by 3/1 P.-ck r ! : Production, Marketing and Production
Planning.
Eliminate overtime on Dorter Job. Complete upgrading of control room.
9A Produettc r. 4/i
Evaluate dismantling air dryers. Dismantle spiral heat exchanger.
9/1 I'i'cc..: 4/3 Rrodv: :..
9. Check asset run versus physical check of department.
10. Obtain credit for TCP and TTCB raw
4/1 JVoiv c ' V .1 3/3. Puiek:
material mischaiges in l$o9.
11. ret.enrilrifc- rvnxinu! i v/.^tor content
steel-KCl systems; to avoid corrosion
9/3.
in off-gas aystem.
32. List and evaluate needs on high repair cost items.
P/3 Main to:, a
on*** HONS
V. yields A. Objectives
Biphenyl TCB TTCB TCP
Goal
W~ 98 98 98
70 St.d.
93 93 99
69 Act. $57?JT~ 98.3'!
9*1.30 91.66
1. Continue close surveillance of blending procedures and. ravs material shipments.
EDC Respon" i. ti 1 (jon- Prod. ..... tin
uing
VI. PROCESS_CCIiTP,OJ, A. 6"63ec-JTves"
1. Improve operational control of the process.
B. Actions
. 1. Identify key process variables and initiate control cherts.
2. Prepare nev; operating instructions. 3. prepare Standard Manufacturing
Process. A. Complete Data Bank. 5. Establish end implement key variable
audit. 6. Make pertinent process control data
available to operators.
M 'Resportsj t Production''
7/1 Production 12/1 Fioduction
11/1 Prod./TSD 6/1 Prod. /:U D
1/1 Produc'd cn
VII. POLLUTION 7T. Object-lves
1. Reduce Aroclor loEf.es to sever from 130 pounds-, pei' day to 10 pounds per Oey from departs-sent.
2. Evaluate need to reduce KOI air pollution:.
B. Actions
1. Quantify process material going to toxic dump.
2. Determine adequacy of drowning jet. 3. Catch all v:c.stcs from drip pans and
sample lines. I\. Modify piping on cent? noons hl<v.. tank
to prevent accident'..'! Arcelor lesr.en to sewer, 5. Modify aVsc-rher rcn'S.ef lino.', to prevent Aroclor fro., reaching the e ev; e r. 6. Bssign and install r. ce-.:er basin to trap accidental /'roc] or loss.es.
7. Establish two week PM on blow tan:: level control(discontinue with Item A completion).
EDO >/:r
6/3 TIL' 3/1 fre/v fi.A
6/1 TAT)
7/1 ik Vfib
Vi 5 Maine
HONS 055695
VII. POI.UITIOi.'Ccont1 ci )
B. ActXons
'
6. Design end install a system to
remove Aroclor entrained in HC1
routinely sewered through drowning
Jet.
9. Continue to monitor sewers to find
sizes and locations of Aroclor losses
in plant.
.
EOC P.osnons j bi.li 1/l/^jToD
Con- Production tin Control uing
Group Members: V. F. Brav.-ley T. H. Carrico Bob Eden
R. 11. Homohries W. A. Kruil
J. R. Xuster R. H. McCutclifin
HONS 055696
COMPANY CONFIDENTIAL MANUFACTURING IMPROVEMENT PLAN
for
AROCLOR DEPT. 2i)6
Approved:
Manufacturing
Maintenance 3//1/70
i57~Trr"Jacr^oh7"B enT'Supt.', ' Technical Services
TT7/^-4;_d2ty^crr TC if T<uhn,TPM
Date Approved: Jan. 29, 197 Date Issued : March, 1970 Prepared by: W. A. Krull R. M. McCutchan R. M. Humphries R. M. Fabian T. E. Green.man
MONS 055697
AROCLOR MANUFACTURING IMPROVEMENT PLAN
DISTRIBUTION
W. G. KrummrlchBlant
C. I-. Bratsch T. W. Dalton C. N. Deubner D. W, Jackson W, L. Watson/D. T. Mayer T. E. Oreenman M. J. Beaudine L. W, Sprandel R, M. Humphries R. M. McCutchan/vV'Brawley/
T. Carrico R. M. Blowers B, R. Villiaras/C. F. Buckley
Anniston
J. C. Landwehr
General Offices
*H. S. Bergen W. A. Kuhn D. Donna (4) R. E. Howard/J. 0. Bright/
R. M. Kountz D. B. Hosmer/F. J. Holzapfel W. E. Chandler W. R. Richard ` D. A. Olson P. G. Benignus
South Second Street
T. M. Patrick R. H. Munch
* Summary Only
o^98 *0ts
TABLE OF CONTENTS
SECTION
Summary P.I.P. Status Action Plan Details Process Synopsis Optimum Process Capacity Quality Yields Pollution Control Process Control Assets Personnel Mechanical Expense Conversion Costs Appendix
PAGE
1 3
I
6 6 7 9 12
12 15 15 16 16 18 22
NO.
I II III IV
V VI VII VIII IX
X XI XII
TABLES
Title
PAGE
Sales Forecast W.G.K. Production Blend Production
Capacity Comparison Paw Material Usage Waste Materials Mechanical Expense Repair Costs Rsxvj Material Comparison Direct Cost Comparison Indirect & Total Comparison Aroclor Costs
7 7 8
8 12 14 36 36 18
19 20 20
APPENDICES
A Present Flovi Sheet
B Possible Continuous Flovi
Sheet
24
C Electrical Grade Analysis 25,
D Quality Comparison
27
E Department Personnel
28
P Work Plan G Process Control Status
29, 32
Report
MONS 055699
Aroclor M.I.P.
-1
March, 1970
SUMMARY;.
A. Objectives ,
W. 0. Krummrich Plant will help maintain the Aroclor franchise position by maKing Aroclor of a quality to match any in the world at or lower than the current cost. The Aroclor depart
ment also has the necessary capacity to meet the market demand as forecasted. The present position and needed modifications are outlined below.
B. Capacity
^.
Sales for WOK Aroclors are forecasted to increase from 42.gff pounds in 1970 to 59.2R pounds in 1974, The Aroclor expansion was designed for 70.OM pounds/year capacity. However, a decision was made not to install all of the storage tanks since they are not required at present rates. Storage capacity and operator
work loads restrict present capacity to an estimated 55.OM pounds/ year. Present capacity is adequate until 1973. Drumming, blending, storage, and off-gas drowning jet capacities will be investigated to insure adequate surge capacity to meet fore casted sales.
C. Quality
During 1969 Manufacturing at VICK demonstrated the capability of producing electrical grade Aroclors which are equivalent to Anniston's from a customers point of view. The present quality is stated to be more than adeqiuite by the Business Group and no effort will be made to improve" it at this time. Efforts wi.11 be
sdirected at maintaining this position. The following table shows the present quality situation for Aroclor 124?.
Present Aroclor 1242
Specification
.
D. Yields
TCC (EE5!)
Resistivity (10" ohm-cm_)_
0.15 0.65 mex,,
3000 500 min.
Power Factor e.t 60 cy. )
2.1 None
' The present biphenyl yield, in Aroclor production is 99+;J, total
potential compared to theory is only $10,000. Ho TSD effort ir. planned in this area.
In 1970 Manufacturing's goal is to improve raw material yields on Pydraui. and Fyranol blends from 94$ to 98$. Estimated savings ere
$5,000.
HONS 055700
Aroclor M.X.P.
2
5/70
SUMMARY:
E. Pollution Control
Water pollution control is the major problem area for this product group and correspondingly the bulk of the TSD effort : for 1970 will be in this area. Losses are presently being investigated by the Pollution Control Section. The total effort and costs are presently in the process of being defined
with a plant goal of 10 pounds per day set by 1/1/71.
P. ' process Control
Effort is underway to develop the Aroclor data bank. The Operating Instructions and Standard Manufacturing Process documents will be revised by Production.. The Department Safety
Audit is current. Control charts have been developed and are being maintained by Production.
G. Conversion Costs
The manufacturing costs in 1969 Tor producing Aroclors at WOK and Anniston were essentially the same ($7.4l/cwt WGK vs. $7.4>5/cwt @ Anniston). Increasing costs due to wages, salaries and materials at WGK are expected to be offset by incree.sed
production volume this year and in 1971. Following is a manu facturing cost projection:
.
ISM
mi
mi
Total Bulk Aroclor ' Manufacturing Costs
' $/cwt
6.78?
7.421
7.236
7.280
Present TSD effort in the chlorine department is projected to
reduce chlorine costs from $53.34/ton to $4l/ton by mid-1971. When this occurs, it will reduce Aroclor costs by an additional $0.6p/cwt to $6.6j/cwt. This is equivalent to $300,000/year savings at a 46.OM lbs/yr rate.
11. Mechanical Expense
The true repair portion of the mechanical expense is expected to increase in 1970 as the result of the expansion ccpital 5 rise"' 1 cb
iri late 1963 and due to increased labor and materials costs, h.h.h repair cost items will be reviewed to determine possible cost reductions.
MONS 055701
Aroclor M.I.P.
-3 -
3/70
SUMMARY:
I. Manpower
The projected manpower expenditure for TSD process engineering is 150 mandays for 1970. If TSD becomes involved with re- ' claiming Aroclors this estimate would increase substantially.
P.I.P. STATUS
The following items were part of the PIP dated 2/21/68 or the P.I.P, Six month status dated 11/22/68. This table gives the present status
of these items as of January 1, 1970. Any items that were com plete at the time of writing the six month status are not included in this list.
JOB 1. Coordinate Quality Tests
2. Fume Removal System 5. Improve Blend Operation
STATUS
Quality adequate as stated by W. A. Kuhn in memo dated 8/25/69. Some items noted in M.I.P.
Installation complete. Extension of system in M.I.P. Action Plan
Project complete
A. Instrumentation Changes
5. New Drumming Facility
6. Horizontal pump and bolldown facility ill still
Complete Carried over to MIP Project dropped.
7. Investigate Possible Blend Specification Changes
In progress by Production supervision.
Other items mentioned in the PIP which stay require work are biphenyl drying, bromine in chlorine, additional blend storage, and blend specifications. The blend items have been carried over to the M.I.P. The raw material items were not carried over since quality is adequat and Anniston is trying to eliminate the water contamination of biphen However, the raw material quality will be monitored.
ACTION PLAN ................... ' '
.................
"
On the following pages is the plan for completing projects to improve the manufacture of Aroclors at WOK, The need for the projects is described in the Details Section of this document.
MONS 055702
..'Arocjlqr M.I.P.
- if -
3/70
GOALS AND WORK PLAN
' ITEM
RESPONSIBILITY
EDO
I. COST: MEET THE 1970 COST STANDARDS FOR ALL PRODUCTS
A. Reduce Drumming Costs
1. Evaluate Improved Drumming Facility
TSD (Process)
6/1/70
B. Increase Yields
1. Improve blend raw material yields
Production
1/1/70
2, Chlorine Usage Study
TSD (Process)
1/1/71
C. Reduce Maintenance Costs
1. Determine Off-Gas Corrosion Level
TSD (Process)
9/1/70
2. Preventive Maintenance List
Production/ Maintenance
3/1/70
II. QUALITY: ALL SHIPMENTS RECEIVED BY CUSTOMERS IN SPECIFICATIONS
A. Roofs on Loading Docks
TSD (Mech. Design)
6/1/70
v B C.
Resolve Electrical Property
TSD/Prod./Malnt,
J/l/71
Measurement .
(Contingent on Lab Air Scrubber)
Pre-Loading Quality Treatment
TSD (Process)
*
D. Ag Grade KC1 Test (Bromine)
TSD (Process)
3/1/70
III. CAPACITY: HAVE PRODUCTION CAPABILITY TO MEET SALES MEEDS
A. Replace Mix Tank Pumps
Maintenance
6/1/70
B. Drowning Jet Evaluation
TSD (Process)
6/1/70
C. Improve Mix Tank Mixing
Production/TSD
6/1/70
D. Establish Minimum Drum Inventory
Level Approved by Prod., Produc
tion Planning & Marketing
Production
3/1/70
* Dependent on ability to reproduce electrical property measur Clients or II B.
MONS 055703
Aroclor M.I.P.
-5GOALS AMP WORK PLAN' - (Continued)
3/70
ITEM
RESPONSIBILITY
IV. SAFETY: NO DISABLING OR SERIOUS INJURIES TO PERSONNEL IN THE DEPARTMENT
A, Fume Removal System Extension
TSD (Process)
B, Lime Delivery Facility
TSD (Mech. Design)
C. Safety Audit Items
Production
EDC
7/1/70 Hold 11/1/70
V. POLLUTION; PREVENT AROCLOR FROM LEAVING THE DEPARTMENT IN THE SEWERS
A. Control Rupture Disc Discharge
TSD (Process)
6/1/70
B. Install Sewer Basins
TSD (Mech. Design)
7/1/70
C. Sewer Pollution Check
TSD (Pollution Con trol)
Continu
D. Reduce Blow Tank Aroclor Losses TSD(Process)
10/1/70
E. Check Aroclor in Off-Gas
TSD (Process)
4/1/70
F. Catch Wastes from Drip Pans and Sample Lines
Production
3/1/70
0. Piping Modifications on Blow Tank TSD (Mech. Design)
5/1/70
MONS 0 5 5 7 0 4
VI". PROCESS CONTROL: MAINTAIN CONTROL OF ;PROCESS & PREVENT UPSKTS
A. Complete Process Variable Chart and Key Variable List
Production
4/3/70
B. Revise Operating Instructions
Production
7/1/70
C. Revise Standard Manufacturing Process
Production
12/3/7'.'
VII. PLANT IMPROVEMENT: MAINTAIN HIGH LEVEL OF HOUSEKEEPING AND IMPROVE OPERATIONS
A. Upgrade Control Room
TSD (Mech. Design)
4/1/70
B, ' Dismantle' Obsolete" Equipment
Maintenance
3/1/70
C. Road & Sewer Improvements
TSD (Mech. Design)
Hold
D. Pave Tank Farm
TSD (Mech. Design)
Ho) ci
E. Replace Lean-To
TSD (Mech. Design
Hold
Aroclor M.I.P.
-6
3/70
DETAILS: A. Process Synopsis
1. Present Situation
Department 2*16 produces Aroclors with 32, 42, It8, 54, 60 and 62 percent chlorine. The name for each Aroclor utilizes a four digit suffix number in which the last two digits indi cate the approximate weight percent chlorine. For example, Aroclor 12A2 contains approximately 42% chlorine,
Aroclor 1242 is produced continuously and the others batchwise, but the main process steps are the same. A flow sheet depicting the process is attached as Appendix A.
The chlorination is done by contacting biphenyl with chlorine gas to cause a substitution of chlorine atoms for hydrogen on the biphenyl molecule. The reaction is catalyzed with ferric chloride. Aroclor and hydrogen chloride are produced. The hydrogen chloride is piped to the chlorosulfonic and/or muriatic acid departments. The Aroclor produced is sent to an inter mediate storage tank.
From the storage tank the crude Aroclor is blown with compressed air to remove any remaining HCll and then straight trite ever distilled with lime. The distilled Aroclor is put through f porocel packed absorber and held in nitrogen blanketed storage.
The Aroclor is either shipped as is or blended with other
Aroclors, trichlorobenzene (TCBl or tri-tetrac'nlorobenzene (TTCB).
. The blends are made by pumping the materials to a tank where
- they are mixed to produce the correct properties. Products
arc shipped in tank cars, tank trailers ana drums.
2, Optimum Process
The optimum process for Aroclor production should be the con tinuous production of all the Aroclors. This could bo done by
vising seven chlorinators in series as shown on the flow shc-ov attached as Appendix B.
The number of stills needed would depend on how many products
it was necessary to produce at eny one time. Appendix !3 skews
the proposed optimum process with three still lines. This eye Is?.,> utilizes existing equipment primarily, with some additions . necessary.
The optimum process will actually depend on the amount of produc tion as well as the relative amounts of each. The forecast: s' rate does not warrant continuous chlorination to higher Ic-vo'c.
MONS 055705
Aroclor M,I,P. 'DETAILS: ' '
-7-
3/70
-B. Products - By-Products ' -`1, Capacity
The following table shows the February 15, 1970 sales fore.cast for Monsanto U. S. Liquid Aroclors.
TABLE I SALES FORECAST (M POUNDS)
Product
1221 1232 121(2 121(8 125lf 1260 1262
TOTAL
1270 ;
0.5 1.3 511.4 7.1 13.7 4.3 1.1
82.4
Ml
0.2 0.8 59.7 8.8 14.5 4.6 1.2
89.8
i272
0.2 0.9 64.7 9.6 15.2 5.0 1,2
96.8
Ml
0.2 1.1 69.8 10.2 16.2 5.4 1.3
104.2
the February 15, 1970 sales forecast ` the part of the total U.S, Liquid Aroclor forecasted for
production at W.G.K. The table also shows the 1969 production Table III (on the following page) shows the forecasted blend production at W.G.K,
TABLE II
Product
1221 1252 121(2 121(8 125i( 1260 1262
TOTAL
W.G.K. PRODUCTION (R POUNDS)
122
1270
1971
0 0.1 22.7
Z-9
8.6 4.2 0.1
42.7
0 0.3 24.2 6.7 7.7 2.9 _ti
41.9
0 0.4 27.0 7.5 8.4 3.0 0,1
46.4
Ml 0
0.5 29.8
8.3 8.9 3.3 0,1
50.9
173
0 0.7 32. v 8.6 9-6 3.5
56.4
HONS 055706
Aroclor M.I.P.
-8TABLE III
3/70
BLEND PRODUCTION (M POUNDS)
Product
''
i27o
mi
1272
1260 PPO 1254 PPO 1242 PPO A13B3B
2.8 0.7 0:7 0.7 4;9 4.2 4;7 5.0 3.5 0.7 0.8 0.9 1.7 1.2 1.2 1.3
TOTAL PYRANOL
12.9
6.8
7.4
7.9
pydraul A-200
Pydraul 280 1254-10# Xylene
4.0
1.0 0.2
4.2 0.8
0.15
4.8
0.9 0.15
5.0 1.0
0.15
* The Aroclor in these blends is already Included in Table II,
1273
o;8 5:5 1:0 1.4
6.7
5.2 1.1 0.15
Table IV shows the known capacity of each step of the process In relation to the required'capacity. The required capacity
is taken from the 1973 forecast in Table II. The demonstrated capacity figures ceune from production records and capacity checks.
TABLE IV
CAPACITY COMPARISON ffl #/YSAR)
Process Step
Demonstrated
1969 Production
1970 Forecast
1973 Poroce.r
Chlorination (1142) Chlorination (other
Aroclors) Distillation (1242) Distillation (1248
& 1254) Distillation (1260,
1262, 1232) Absorption (1242) Absorption (1248) Absorption (1254) Absorption (.1260)
Blending (Fydrauls) Blending (Fyranols) Drumming (All)
37.5* 25.9*****
31.9* 21.9**
8.5**
51.7* 35.9* 34.4* 60.7*
6.3** 14.5**
22.7 20.0
22.7 1.15.6
4.4
22.7 7.0 8.6 4.2 5.0
12.9 13.3
24.2 17.7
24.2 14.4
3.3
24.2 6.7 7.7 .9 5.0 6.8
12,0
32.7 22.7
' 32.7 18.4
4.3
32.7 8.8 9.6 3.5 6.3 8.7
15.4
* Capacity Check
** Extrapolated Monthly Production Kecord
*** Extrapolated Monthly Production Record with 13 shifts/week plus
overtime.
'
HONS 055707
Aroclor M,I,P, DETAILS
-9-
3/70
8. Products - By-Products
1, Capacity (Continued)
In every case in Table IV, the demonstrated capacity exceeds
the forecasted 1973 production requirements. The chlorination and distillation figures represent something less than maximum
capacity, so these operations appear adequate through 1973. The absorbers and blending also appear adequate.
The drumming and blend storage capacities'were marginal in
19^9, However, with the significant decrease forecasted for Pyranol blends (12,9 E pounds in 1969 vs. 6,9 E pounds in 1970) capacity in this area is adequate. The Pydraul and Pyranol blends will be watched for sales forecast changes and actions planned accordingly.
It is anticipated that Aroclor storage would restrict capacity to about 55 M pounds per year. This is above the 1973 forecast but the restriction may require investigation. When the recent expansion was installed, CED forecasted a need for three more
22,000 gallon storage tanks in 1970, but due to the reduced forecast, the additions can probably be postponed.
To operate the department at full rate, personnel additions may be necessary. It is anticipated by Production that the chlorinators and stills would need additional operators, Production will attempt operation at high rates at 6 month intervals to insure system capability.
.
s The off-gas drowning Jet in the department could restrict capacity due to Jet size if it becomes necessary to operate
when muriatic acid and chlorosulfonic acid are shut down. An evaluation of the scrubber will be made to determine the
operating limit of the present system and the cost to add capacity,
2. Quality
As specified by W. A. Kuhn in a nemo dated August 25, 1969
the finished goods quality of the Aroclor presently produced is satisfactory. Only minor projects to maintain the quali;y will be done. A project to put roofs on the tank car loading docks will be done which will insure against contamination while loading.
K0NS 055708
^Arocidr M;I;P.
- 10' -
;3/70
-2,- Quality (Continued)
The following table relates the present storage tank quality .of Aroclor 1242 to the present specifications. It also ;shows the present control levels at which production becomes
.concerned that the quality level is deteriorating and correc tive action is taken.
........... ..... Specification
AROCLOR 1242 QUALITY
- -- ; TCC
" Resistivity
ism) . (10y OHM-CM)
0.65 max.
500 min.
' ' Power Factor {% at 60 cy.)
Hone
Storage Tank Quality 0.15
3,000
2.1
Control Level
0.20
1,500
3.5
The major quality concern at the plant is the analytical method used for electrical properties. The problem exists in the reproduceability of results with both the present
method and the new'tentative method. The tentative method tends to show better properties but is inconsistent. The present method requires meticulous lab procedures or shows poor results. To compound the problem, the manner of taking and handling the sample can ruin the results. This whole problem needs to be resolved. .
The lab is installing a new air scrubbing system which may help the new tentative method. The short term procedure is to have Organic Research run samples periodically to check the plant lab results. Longer term, the new system will be checked when the air scrubber is installed. If it looks like the problem is solved, we will use this procedure, If not, an evaluation of an Isolated Aroclor analytical facility will be made. Improved sampling procedures will also be tried.
Other measures that may improve the quality of Aroclor will be
held in reserve until a better quality is needed to meet market
demands. A list of these follows:
.
Measure
Effect
1. Separate chlorine revaporisation Better quality raw material
.2 High temperature aging
May have slight stability benefit
3. Alternate absorber packings
Better electrical or stab.il.it qualities
MONS 055709
Aroclor M.I.P
11 -
3/70
DETAILS:
2. Quality (Continued)
Aroclor quality is generally consistent, but one upset has occurred. Colored product suddenly appeared in early June, 1969 and stayed until July. Procedures used to eliminate the problem included: Cleaning the intermediate storage tank, still, receiver and the line between the still and receiver; changing the porocel, absorber; and making sure the still vacuum is vented at the receiver and not at the still. Since July 20, 1969 there has not been a color higher than 15 APHA. Of the items attempted to remove the color, it seems the venting of the still is the most likely suspect. Venting at the still could cause off color material to be drawn forward from the still bottoms.
For a few consecutive lots in September, 1969 Monsanto stability was high. After many attempts and failures at both Anniston and W.G.K., the lab re-runs came out within specifications. Part of the lab equipment evidently became contaminated. The quality of the Aroclor had not changed.
The quality of raw materials will be monitored with control
charts. In May, 1969 the water content in biphenyl increased
to 100 ppm. This could cause excessive corrosion in the off gas system. Since October, 1969 the water content has returned to a normal level of about 50 ppm.
An evaluation will be made of a filtering end absorbing steu just prior to loading tank cars and tank trailers. It is ' occasionally necessary to resample e~nd sometimes unload a car or trailer because the electrical properties have detcrioratr d,
Nine complaints were received from customers in 1969 of v:hich seven pertained to shipping container complaints and only two on material quality.
Appendix C contains a table showing seme of the properties of VJ.G.K, Aroclor, The figures represent August, 1969 YT'D produc tion. The other table in Appendix D shows a comparison iatwe-; r>
Monsanto, Bayer, Soviet Askarel, Prodelec and Kanegefuchi
products of similar chemical makeup. From the table, it can be seen that the products have similar quality except for the
generally inferior duality of the Soviet Askarel. This table was made using V.'GK, ~PR D Report Ho. 2, Job Ho. tORJ, dated V28/69; Anniston Research and Development Report No. J>, Job Ho. 570-502, dated 7/19/68; and a mono from C. R. Coleman, Ruabon to J. H, Heggart, Brussels, dated 5/28/69.
MONS 055710
Aroclor M.I.P*
12
5/70
DETAILS:
B. Products - By-Products (Continued)
3. Yields
'
The cost sheets and operations reports for 1969 for Dept. 246 were used to derive this table.
TABLE V
RAW MATERIAL USAGE
Raw Material
Theory
(Total Pounds) Actual
(Actual-Theory) difference $/yr Potential
Biphenyl Chlorine
23,159.050 39,998.413
23,338,758 42,668,421
179,708 2,670,008
10,000 73,000
TCB
2,603,092
2,647,033
43,941
5,000
TTCB
991,327
1,051,778
59,951
7,000
The yield on Biphenyl is 99-3f and would be difficult to improve. The chlorine yield is not an accurate figure since a pro-rating procedure is used to determine usage. An attempt will be made to determine actual chlorine losses.
The low TCP, TCB end TTCB yields will be investigated by Production. The amount of these materials actually received may not be the same as the amount Purchasing specifies. If ' this is not the problem further investigation may be necessary.
4. Pollution Control
The escape of Aroclors to the environment poses a serious business threat to this product group. There is concern not only in the production of these products, but also customer handling of these products and the disposal of spent Material. To cope viith this problem we must reduce plant losses, educate users and resolve customer spent material disposal.
The WOK plant objectives for 1970 are to reduce Aroclor losses to the sower to JO pourids/doy by 10/1/70 and to 10 pounds/d ay by 1/1/71.
MONS 055714
Aroclor M.I.P.
- 13 -
5/70
-DETAILS: . \ .
4. Pollution' Control (Continued)
Present losses are estimated to be 230 pounds/day by the 'TSD Pollution Control Group. Of this total 130 pounds/day
are estimated lost by Department 246 and the remainder from other departments in the plant.
These goals require the following actions:
a. .. ... :
Production housekeeping to reduce leaks and spills reaching the sewer. Actions have been taken to do this and more will be added as data shows the need.
b. A project to prevent the blow tank from overflowing due
to instrument failure as it has in the past. Piping the
blow line through the intermediate storage tank will pre
vent this loss. Mechanical Design has the project package
out with completion expected in March, 19?0. This is
Estimate Number 1493 for $5,400 expense.
c. A project to prevent the losses from the relief lines of - the absorbers from reaching the sewer. This is necessary " because the rupture discs have allowed material to reach
the sewer in the past and although production has made operation changes, we cannot be sure losses will not occur again. This project has Estimate No. 1512 for $6,000, of which $1,500 is expense and $4,500 capital. Installat.io is expected by 7/1/70.
d. A system to remove Aroclor carryover in the blow ton!: line is necessary since we know at least 25 pounds per day is lost here. This goes to the sewer through the drowning
Jet. Controls will be installed to reduce the air flow
and an estimate will be made of costs to reduce the amount carried over in the remaining air.
e. A basin intercepting the sewer to collect the non-routino
losses is being considered. This would allow' the Aroclor to settle out of the sewer water leaving the department.
The total estimated expenditures for all these projects is about $50,000, half expense and half capital.
MONS 055712
Aroclor M.I.P.
- 14 -
3/70
DETAILS:
4. Pollution Control (Continued)
Other pollutants are not thought to be of a serious nature. . Atmospheric pollution is held down using a scrubber which
will be evaluated for capacity. Some HC1 loss is evident when a large amount of off-gas is sewered in the department.
Using yield data, the amount of waste materials was esti mated by R. McCutchan based on 40 R pounds per year production. These figures account for all yield losses and are maximum
amounts. This estimation is shown in Table VI.
TABLE VI__
WASTE MATERIALS Atmospheric Pollutants
Material
HC1 Chlorine Aroclor + Biphenyl Pydraul TCB & TTCB Pyranol
#/Year
8,000
Not Measurable Very Small Slight ' 1,800 3,600
Sewer Pollutants (Potential)
HC.1 Aroclor
TCB & TTCB Chlorine
Pydraul & Pyranol
200,000 50,000 10,000 0 10,000
Montar Aroclor
Pyranol Pydraul
Toxic Pump
160,000 40,000
0 0
HONS 055713
Aroclor M.I.P. DETAILS:
- 15 -
5/70
5. Process Control
The preserit level of operator training is adequate and the present training policy for new operators will be
continued. The length of operator training varies from J to 6 weeks depending on the job.
The May, 1969 safety audit contains a number of control
items which will be completed according to the priority
set in the audit. A quarterly review and report on these items will be made.
In addition to these items the blending procedure may need
modification depending on the outcome of the blend specifi cation study.
Control charts are being initiated for the finished product and raw material analysis variables. These charts should
give an indication as to the level of control existing in the department and the areas in need of improvement.
The Standard Manufacturing Process documents are being re vised by Production. The documents will be completed for
all products and processes. Attached as Appendix F is a list of process control measures to be taken along with expected dates of completion.
C. Assets
Since the facility is presently adequate to meet the forecasted manufacturing requirements, no major e-dditions or changes are anticipated. The project to replace the lean-to used for drumming is presently on hold with no date of completion fore casted.
Minor changes in the assets of the department are outlined in the Action Plan and explained in various parts of the Details Section of this document.
The capitalization of the facility as of January 51, 1970 was;
Asset Value - $2,057,107
Accrued Depreciation -
769,^95
Book Value - 1,267,612
MONS 055?l<t
Aroclor M.I.P.
- l6 -
3/70
DETAILS:
D. Personnel
No change in the present number of personnel is anticipated. The present number of operators is sufficient to handle the forecasted manufacturing requirements up to 55 Fi pounds/year.
If the rate is increased to a level near 100$, additional
operators may be needed. A study of the needs of the department will be made when it appears the need is arising.
A listing of operators and their duties is attached as Appendix "D'1. The total number of operators in the department is 17-1/2.
E. Mechenlcal Expense
The 1968 and 1969 mechanical expense and the 1970 budget for Dept, SJI6 is tabulated below:
TABLE VII
Areas and Shops Plant-wide
91> 92 & 93 expense jfc Absorbed 0.H,
1968
$32,808 27,367 86,156 1,768
i22
$54,600 39,700 1(1,200
- 4,600
1970 (Budget!
$ 49,700 50,500 66,900
$158,099
$131,000
$167,100
The primary repair cost occurred in the following categories:
TABLE VIII
1968
19 pimps
$15,153
21 Tanks
3,689
87 Dept. Repairmen
4,018
97 Piping 29 Instrument
5,339 7,820
25 Ejector
2,345
80 Painting
2,769
82 Insulation
6,158
Electrical
. 5,537
98 Structural Steel 10,189
1969
Change 1969-1968
$25,400
5,013 11,600
5,300 16,300
700 200 12,190 2,800 500
$10,247 1,324 7,582
39C-) 8,480
1,645 (-) 2,569$-) 6,052
2,737(-) 9,609 -
$10,700 3,400 9,800 6, goo
12,800
2,500 5,900 15,200 9,300
500
HONS 055715
Aroclor M.I.P,
- 17 -
3/70
DETAILS:
i E. Mechanical Expense (Continued) "Of'particular Interest are:
-Pumps: '
Pumps accounted for 26.9% of the total true repair expense. A Malnt. Engineering assignment has been
Initiated to solve the therminol pump cost problem. This pump and other pump seal problems have been identified as the major problems.
Dept, Repairman: This item accounted for 12.3# of the true
repair costs. These costs will be reduced in 1970,
High costs are attributed to leaks from new piping
Installed by outside contractors. Material costs
. will be investigated to Improve any repetitious
repairs being made by the repairman.
.
Instruments & Electors: These items accounted for l8f of the true repair expense. Costs will be approximately the seme in 1970. Inflationary increases will be compensated for by improved P.M. of equipment.
Insulation: Insulation costs accounted for 12.9# of the true repair costs. Normal repairs and programmed upgrading planned for 1970 indicate an expenditure of approxi mately the seme magnitude.
Maintenance Engineering:
1) Replacement of the obsolete Taber pumps on the #2 and #3 mix tanks is planned for 1970,
2) Alarm system tie-in for. the spare #2 still pump
will be completed in 1970.
3) Implement Safety end Inspection Procedure for unfired pressure vessels in 1970.
Programmed Plant Improvements:
1) Provide drainage North of department
along tracks
*
$ JO,000 Cep.
2) Replace lean-to to Building CR
$100,000
These projects are on hold status at the present time.
M0NS 055716
Aroclor M.I.P.
DETAILS:
- 18 -
5/70
E. Mechanical Expense (Continued)
..
Corrosion in the off-gas system has occurred in the past in the header and the condensate tank vapor space. It would be useful to determine what moisture level can be tolerated, but it is hot'
known if this level can be determined. If there is a good prob ability of success, the determination will be attempted on a low priority basis.
Estimated damages of $25,000 resulted from the explosion in Department 222. The repairs are presently in progress.
F. Conversion Costs
Table IX below shows a comparison between Krummrich and Anniston
Liquid Aroclor raw material costs. The figures were obtained from the cost reports for the year 1969. Following is the comparison:
TABLE IX RAW MATERIAL COMPARISON (gi/POUND)
Item
Chlorine Biphenyl Drums HC1 "Nitrogen Lime 5 Gal. Cans Clay and Porocel Ferric Chloride
W.G.K.
2.674 2.952 0.199 0.5750.013 0.001 0.004 0.005 0.006
Anniston
2.433 2.824 0.306 O.I980.023 0.007 0.004 0.003 0.002
Difference W.G.K. - Anniston
0.241 0.128 0.1070.3770.0100.006-
' 0.002 0.004
Net Material Cost Material Handling
5.279
0.021
5.404 0.013
O.I250.008
TOTAL RAW MATERIAL COST 5.300
5.417
0.117-
HONS 055717
Aroclor M.I.P DETAILS:
19 -
3/70
P. Conversion Costs (Continued)
Although the total raw material costs are almost the same, '
there are some outstanding differences between the two plants.
The muriatic acid credit at Krummrlch is much higher and off
sets the higher cost of chlorine and biphenyl. This compari
son does not mean a great deal since the usage of raw material
would depend on the type of Aroclor being produced. Chlorine
and biphenyl are more costly at Krummrich.
Table X shows the direct conversion costs.
TABLE X
DIRECT COST COMPARISON (d/POOHD3
Item
Steam Electricity Comp. Air Water Gas Wages Salaries Payroll Overhead Supplies Packing Labor Packing Overhead Laboratory Clothing H Laundry Technical Services Experimental Rental Equipment Prod. Process Res. Prod, Dept. Contr. Tank Car Storage Mech. Expense Stert-up Expense We.ste Disposal Research
W.O.K
0,216 0.029 O.OJO 0.024 0.004 0.372 0.070 0.074 0,050 0.044 0.023 0.074 0.011 0.037
0.002 0.047
0.005 0.305
Anniston
0.137 0.023
0.020 0.021 0.261 0.041 0.056 0.058 0.050 0.018 0.051 0.005 0.070 0.116-
0.008 0.026 0,035 0.561 0.018 0.074 0.001
Difference W.G.K. - Anniston
0.079 0.006 0.030 0.004
0.017 0.111 0.02` O.Oli 0.00C0.006 0.005
0.023 0.006
0.033 0.116 0,002
0.039 0.026 0.030 0.256 0.038 0.074
0.001-
TOTAL DIRECT CONVERSION
1.417
1.398
0,019
0NS 055718
Aroclor M.I.P.
-20-
3/70
DETAILS:
'
F. "conversion Costs (Continued)
Although the preceding table shows the total direct conversion costs about the same, four differences are evident. W.O.K. Esteem costs more per M BTU than Anniston, explaining the steam
difference. Steam usage is about the same. Anniston has a' credit listed under experimental amounting to about 12^/cwt. Mechanical Expense and waste disposal are items where Anniston is significantly higher than. W.G.K.
Table XI shows the indrect costs and a total.
TABLE XI
1969 INDIRECT & TOTAL COMPARISON (^/POUMD)
Item
W.G.K,
Anniston
Difference
Total Raw Material Total Directs Depreciation
F.I.E.
5.500 1.5*17
0.40? 0.?01
00..2?927?
0.117 0.019
0.106
0.022-
TOTAL PRODUCT COST
7.421
7.4?5
0.014-
The total product cost was roughly the same for the two plants. Anniston's higher raw material costs, due primarily to a smaller
HC1 credit, are offset by the WGK depreciation being higher than Anniston.
Table XII breaks down the Krummrich costs for 1968 and 1969; 1970 cost standards for a rate of ?,920,000 pounds per month (?>?47,000 forecasted); and a rough prediction of 1971 costs. The 1968 and 1969 figures are corrected to reflect an approxi
mate bulk cost which would correspond to the cost standard figu> The 1970 and 1971 figures represent a bulk cost taking into account the forecasted amount of each Aroclor.
TABLE XII
AROCLOR COSTS (j/POUND)
Item
Total Raw Material Total Directs Total Indirects
1968
4.770 1.545 0.470
M2
5.?oo 1.417 0.704
1970 Std.
5.169 1. >86 0.681
1971
5.200 1.4?0 0.650
Total Aroclor
6.785
7.421
7.P36
7.280
HONS
Aroclor M.I.P.
21
3/70
DETAILS:
F. Conversion Costs (Continued)
The costs forecasted for 1971 assume that the raw material price will not change significantly. Items showing an anti cipated increase are labor, salaries, payroll overhead, and mechanical expense. These items were Increased by about 10, The increases were offset by an anticipated increase in production causing the total costs to hold roughly the seme.
Present WOK plant chlorine costs are $53-34/ton ($.02667/lb), This cost is targeted to be reduced to $4l.00/ton ($.020/lb)
by 7/1/71. This would decrease liquid Aroclor manufacturing costs by approximately $0.65/cwt to $6.63/cwt in mid 1971. This is equivalent to $300,000/yr at a 46,03 lb/year rate.
The following lists show the relative dollar amounts of each category and are taken from the December, 1969 YTD cost sheet.
COSTS
Items Raw Materials
Amount $2,266,443
% 71.4
100,0
Direct Costs Wages Mechanical Expense Steam Laboratory Payroll Overhead Salaries
v Prod. Process Res. Supplj cs Packing Labor Technical Services Compressed Air Electricity Packing Overhead Water Purchased Cl & Laundry Safety Tank Car Storage Gas
Clothing Laundry Rentals Equipment Experimental Plant Trucks
Indirect Costs
Depreciation FIE
.
606,474 159>072 130,441
92 31,734 31,802 29,857 20,017 21,213 18,807 15,675 12,877 12,222 10,022 10,218
3,082
2,245 1,877 1,615
906 200
4o
301.080
172,113 128,976
19.1 5.0 4.1 2.9 1.0 1.0 0.9 0.6 0.7 0.6 0.5 0.4 0.4 0.3 0.3 0.1 0.1 0.1 0.1
---
9.5 5.4 4.1
100.0
26.3 21.5 15.3
5.2
5.2 4.9 3.3 3.5 3.1 2.6 2.1 2.0
1.7 1.7 0.5 0.4 . 0.3 0.3 0.1 0.0 0.0
100.0 2
42. e
'A), $3;174,006 100.0 * This shows the breakdown of each major division.
HONS 05572
AROCLOR COSTS AND PRODUCTION COMPARISON 0?A?W.
Product Hill pound-, per year
Years
HONS 055721
Aroclor M.I.P.
- 22 -
3/70
V. APPENDIX
Pecs are the items mentioned in the report as
additional information relating to the process, quality and
personnel,
'J
HONS 055722
n' 1 " Chlorine
22 APPENDIX A
HONS 055723
Biphenyl o^henyl Stor rj;r. it
^Cb-lox-
Sic
!Cat. Tank I
Jntalyst
P0SSI5L3 CC 'SOOTS ARRAIfGEKEUT
-^thlofr 7ii32
Int.: I Sto^
' SP
Zh..j! oCrT| ____ i
:xiu8 \~w
#3 :ll6o
^Chlor;------ >* ChXor^i^^hlori--T-->-Chloi* or
I , jJ ! L!
/ --Jll6s
mstr
Int. j Stor!
ILtlgS--TZ&~'i
?Tnt. f jstor
Int. :stor
:l. ..
...
Int.j11*8 Int. j lisa
Stor {
. jstor
Blow; Tank
...i
V
Blow j Tank
31ow j V jTank I `
'T`
V
Jt.
.
Bottoms
;#1 C--------- Still'
J5T.BOttOES I----------"fS1t1ill i Y :
Bottoms !----------Stillj T ~r
Y Jl
; j //2 j 1 <'J- ' T "* ;
r--p
: #1 j : Hoc j. *> -
#3 j Rec |
.#**!! Sec | ;
^ZiS S O SNOW
!i
1 b'cor i
$2W
r* &*- tl_
^260
. #4 i ,Abs.|
V/I262
#1 Blencj
i
i 1 F.P. !
! 'f
t i
i
j 1260] { Stor!
1262 Stor
----- . , . --r*. 12*2
rJL_
p5 i
?urSel
_V Ji! Abs
IF.?. j
12t8
_Y #2 ; Abs I
V P" i iSurge ..P- '
Y l#3 j klbs j
V
I F.P. I
! 125*
* or
tor; inks.; stor J
Stor; 125* ,Stor.J
- 25 -
appendix c
1969 ELECTRICAL GRADS AROCLOK ANALYSIS
1242 Lots
TCC (ppm)
-9 Lstivity X10
KL-403 -4
-9 - 12
- 15 - 22
- 25 - 27
- 29 - 31 - 34
- 37 - 39 - 43 - 44 - 46
- 47 - 49
- 51 - 52 - 54
- 55 - 57 - 63 - 65 - 68
- 71 - 76 - 78 - 80
- 81 - 64 - 86 - 88
- 89 - 91
- 93 - 96 - 98
- 99 4003 4 006
4007 4 016
4018 4019
0.13 0.16 0.11
0.12
0.12
0.15 0.12
0.13 0. n 0.16
0.18
0.18 0.19
0.11
0.12 0.14
0.16 0.14 0.11 0.18 0.14
0.12
0.18
0.08 0.10 0.17 0.07 0.36
0. 3.5 0.12 0.13
0.25 0.09 0.14
0.15 0.10
0.17 0.17 0.23 0.33 0.13 0.17 0.24 0.10 0.14
0.19
2600 1850 8900
2680 2400
1475 104 00
2640 6404
1675 1065 3250 2150
1360
1300 2650 1750 4000 2000
1000
945 1020 2400 2640 1850 7450 2 BOO 8.I.60 .1.760 24 80 2400
59:;5 2320 1480 384 0 3650 3.04 0 5443 2240
632 2000 13.05 1841
1200
8000 6300
Power Factor
1.26 2.16
0.77 1.62
1.66 3.83 0.60 1.98 0.99
2.31 3.16 1.33 1.27 2.94 1.40
1.99 2.83
1.19 1.77 2.94 2.29 2.50 2.01
1.80
1.80 0.8.1
1 34 0.99 2.8? 1. %
1.74
1.17 2.58
2.58 1.98
1.39 3.4? 4.80 ?. 76 4.17 1.68 2.65 a. 89
1.51 3.48
1.37
Specif i ca.ti on
0.65
500 Min,
[.one
HONS 055725
- 26 APPENDIX C
1969 ELECTRICAL GRADS AROCLOR ANALYSIS (uoramued;
121)2 lots
TCC (ppm)
Resistivity X10`9
1)021
1)025 1)030 1)038
1)01)1 1)01)8
0.15 0.16 0.14 0.14
0.25 0.11
2960 1200 3760 3520 1680
1520
7 Power Fac
1,49 4.62 1 2Q 2.28 3.00 2.70
121)2 Average
Specification
12511 Lots
KL-603 -^ -7 -9 - I? - 15 - 17 - 24 - 26 - 30 - 33 - 43 - 45
1254 Average
Specifications
0.15
0.65 Max.
0.57 0.77 0.80 0.49 0.57 0.46 0.41 0.55 0.36 0.44 0.30 0.55 0.55
0.52
None Set
3021 500 Min.
8000 9445 16,250 17/600 30/400
7200 10/900
30,400 20,800 40,000
32,018 14,408 16,8.10
'
19/556
500 Min.
2.09
None
0.43 0.44 0.36 0.35 2.4b 0.46 0.76 0.29 0.32 0.56
0.69 0.47
O.GO
None :
1260 Lots
KL-1003 -5 -6 -11 - 12 - 17 - '}&
'
1260 Average
Specification
1 Not Analyzed
1 |
53,633 24,800 64,037 160,000
9,846 26,415 60,038
56,966
500 Min.
0.39 0.30 0.2 V oMj 0.60 0.3? 0.20
0.33
None J
HONS 055526
APPENDIX D
QUALITY COMPARISON FOP ELECTRICAL GRADE AROCLOR 1242
Property
Monsanto
Specifi-
1
cation
U.G.K.
3 Annie-''
0 v Kanega-''
ton Aokc.re.l Bayer' fuchi Prod.'? e.
Color (APHA) 4o Hex. free Chloride
(ppm) Acid No.
0.05 Max
(Mg KOH/g) Monsanto
Stability (ppm)
Hydrolysis
0.010" 0.4 Max
Chlorides
0.5 Max
toTM) Thermal Chemi cal Chlorides 0.63 Mux
(ppm)
Wcstinghouse Stabil.1 ty
(PP-n) ,, Ml) at 25 C
1.6240 1.6260
Sp. Gr. at
1.381 -
25 c. Viscosity at
100"C (SOS)
1.392 62 - 92
Pour Plant
-(C) Power Factor
(.IOO"C)
-14 Min.
1000 cycles 60 cycler.
Jliclectrl c
Constant
4.70 -
(100"C)
4.90
.1000 cycles
CO cycles
Resistivity at
JOO'C
q 500
(0:it:-ct10 * )
Dial illation
Ha'.gc (C)
lop
90;.: Viator (pp>:.)
525 MS'.i 360 Max
yi> Mfex
10 0.02 0.001 0.12
0.06
0,14
0,30 1.6251 1.384
83.6 -17
0.15 1.95
4.83 4.86 3500
321 353
18
15 0.01 0.001 0.10
0.12
0.18
0.32 1.624? 1.386
87.2 -18
0.1? 1.00
4.82 4.83 3600
327 362
27
40 0.009 0.002 0.37
0.67
1.95
1.6228 1.380
79-0 -15
0.50 4.50 4.72
1200
323 35-1
28
10 10 0.009 0.018 0.001 0.001 0.03 0.02 0.07 0.11 0.14 0.16
1.6240 1.6?51 1.381 1.391
0. ?3 2.01
4.8.1
O.Jo 3.81
4.89
800
500
3?7 3''9
62
228 260
94
10 0.018 0.001 0.06 0.3 1 0.16
1.6?!',G Ji .Av Mr> - v
0,26 2.4 0 h ,f2
7 0''
229 246
51
1) V'von V!0Si, Pi'.?:)) Report No. 2, Job llo. 91270'4022, doted 4/28/03.
2) non Ann!aton Report No. 2, Job No. 270-903 deled 7/5/68.
,) 4;Vo*:i S:!.ip.i cr. rood vod ft Arm Is ton in 1966 end reported in Remcr'.'i
& Development Report No.
Job No. 270-302, Oeted 7/19/60.
HONS 055727
* apfztjbia E DEPASTKEST 2-6 PEHSOCTEL
I supervisor I
i icrc-en m
<!
I
!W
Second peer. (t)
! Swingrr.an (1)
Standard
7' Days/'vk 3 Shifts/
Day
7 Dc.ys/Wk 7 Days/VJk
3 Shifts/ 3 Shifts/
Day
Day
21st Shift-Still
Duties.
Duties
Duties
21st
ic-tch
2 Still s
Shift-Second
5 Chiorinators
3 Mix Tanks S -Y. S
Sew
T ank Farm
Standard
Catalyst 2 Stills
1 Day
1 J&x Tank
Load all
Standard
2 Blovr
C?.rs and
Bichcryl
Tanks
Trailers
1 Head Tank
Pump
^ Absorber? Pinished
1 Off Car-
me Product
Condenser
Ccr.nlt?te Tanks to
Charge of Storage
1 Off Gas
T'lernino-
Stores
teatin-
Tank Sc Mist Svster.
Eliminator
1 Cor.tlr.-
Sample
1 Surge Tank 53 or
5 Days/Wk 2 Shifts/
Day
Duties
All Drumming of material in Dept.
1! Renair
5 Days 1 Shift
Biphenyl Handling
and All Repair Vterk
ll?TS | Porter (1/2)
Monday
0 Days/ra
21st Shift- 1/2 Shift
Premium
Day
Thurs & Fri
2 Days Repairman
Sat. & Sun.
2 Days Relief Foreman
Clean Con
trol room Rest Room 2 Offices
and Smoking
Shelter
055728
5 ST" n ?.
a'OEK
no. 1TDY l Reduce Drumming Costs
CC3T
EST. MAM-DAYS
RESPONSIBILITY
EDC
COMMENTS
A. Insulate #7 Storage Tank
$2500
0
TSD (Process)
1/1/70 CANCELLED
B. Evaluate Improved Drumming 2, Increase Yields
05
TSD (Process)
6/1/70 Report Drafted
A. Improve Blend Raw Material Yields
00
Production
1/1/70 Action Taken
B. Chlorine Usage Study
0 10
TSD (Process)
1/1/71 In Progress
3- Reduce Maintenance Costs
A. Determine Off-Gas Corrosion
0 10
TSD (Process)
9/1/70 MM&T Advice Needed
B. Preventive Maintenance Lists Maintain Quality
0 10
Prod/Maint.
3/1/70
In
Progress 0
vroo
A. Roofs on Loading Docks
8000
15
TSD (Mech. Design' 6/1/70
3. Resolve Electrical Property Measurement
0
C. Preloading Qt ality Treatment T.B.D.
0 20
TSD/Maint TSD (Process)
1/1/71 *
Waiting for Lab Scrubber
Waiting for 4B
D. Ag Grade KC1 Test Maintain Adequate Capacity
0 10
TSD (Process)
3/1/70
Check effect on Arocior
A. Reolacc Mix Jerk Pure s D. Drov.'r.i:'" Jet Ivc.luation
$5000 0
5 5
Maint. TSD (Process)
6/1/70 6/1/70
Ivicrovc Ml:: `ink Mixing
Q5
Production/
TSD (Process)
oCOn r'. `"`.ty to r??~or\ co elcctri A1 property nerevrements
8/1/70
Obsolete.
Check Capa city '
Minor Modi fication
WC~X PLA?.T - (Continued)
APPENDIX F.
T'nrvr
EST.
EST.
COST MAN-DAYS
RESPONSIBILITY ` EDC
COMMENTS
intain Adequate Capacity (Cent m)
D. Establish Minimum Drum
Inventory
.
0 5 Production
3/1/70
6. Provide Safe Vorking Atmosphere
A. Fume Removal System Addition $8000
3. Lime Delivery Facility
1000
10 5
TSD (Process)
TSD (Mech. Design)
7/1/70 Hold
Extension of System waiting
for fork lift app.
C. Safety Audit Items
T.B.D 15
Production
11/1/70 Ref. Safety Audit
7. Keep Aroclor from Sewers
A. Control Rupture Disc
tv:
5000 15
(TSD-Process)
6/1/70
Recycle to Surge Tank
B. Install Sewer Basins n Sewer Pollution Check
$11,000 0
15
TSD (Mech. Design)7/l/70
TSD (Pollution Control)
Cont.
Trap Aroclor
Sampling to continue
MONS 055730
D. Reduce Blow Tank Losses
0 10
TSD (Process)
10/1/70 Aroclor to sewer
z. Determine Amount of A-oclcr In Off-Gas
7. Cater Vactos from Drip D-vur C:v.*r>le linos
r. P.vv.r : V-' 1
s on
05
00
5-CO
20
TSD (Process)
Production
TSD (Xech. '* z: pn
4/1/70 3/1/70
At Dents. 217 218
5/1/70
MCNS OSS
APP~K?.~..T ?.
VO??:
fContinued)
2S7.
2ST.
NO. COST KAN-DAYS
3 Maintain Control of Process
A. COT.pr.ctc Process Yaricblcs CP-t.rt !; Key Vo.ric.ble List
0 10
3. Bevisc Operating Instructions 0 10
C. Revise 5td. Mfg. Process
0 10
9 Maintain M.lr.h Level of House keeping and Improve Operations
A. Upgrade Control Room
$!'?, CCO
0
3. Dismantle Obsolete Equipment 2, TOO
0
C. Rood -5: Cover Improvements
50,000
20
D. Pave Tank Part!
T.3.D.. 10
E. Replace Lean-to
$200,000
30
RESPONSIBILITY
EDC
COMMENTS
Production
Production Production
Vl/70 In progress
7/1/70 In progress 12/1/70 In progress
TSD(Moc h.Design) 4/1/70 In progress
Maintenance
3/1/70 In progress-
TSD(Koch.Design)
tt W
tt
M ft
ft
On Hold No work being done
On Hold No work being done
On Kold No work being done
HONS 055732
PKOC3SS CONTROL STATUS REPORT AND OBJECTIVES
PROCESS
Aroclor.
Pyranols
pydrauls
Z. Data Banh
.. Standard M?r*.ufacturina; Process
3/1/7C
3/1/70
3/1/70
t. Safety Audit
3/1/70
3/1/70
3/1/70
c. Tentative Process
3/1/70
3/1/70
3/1/70
d. Chemical/Fhysical
Properties
3/1/70
3/1/70
3/1/70
e. Monthly Operation Reports
3/1/70
3/1/70
3/1/70
f. Monthly Key Variable
, Keeorts
5/1/70
5/1/70
5/1/70
g. Process Control Audits
3/1/70
8/1/70
8/1/70
h. Corrolair.t File
3/1/70
3/1/70
3/1/70
i. Customer Service Pile
3/1/70
3/1/70
3/1/70
j. Lo,~ -Sheets
3/1/70
3/1/70
3/1/70
k. Operating Instruc tions
3/1/70
3/1/70
3/1/70
1. Data Bank Index
3/1/70
3/1/70
3/1/70
it,. IFO's
3/1/70
3/1/70
3/1/70
11. Variables Analysis
a. Variable AraJv^is
2/20/7C
3/1/70
3/15/70
b. Y.'r; Va-.! ab Vvr
4/1/70
4/1/70
4/1/70
1254/10 Xylene
12/1/70 'l
3/1/70 3/1/70. 3/1/70 3/1/70 5/1/70 8/1/70 3/1/70 3/1/70 3/1/70 3/1/70 3/1/70 3/1/70
3/15/70 4/l/ro
APPENDIX G (Continued) PROCESS CONTROL STATUS REPORT AKD OBJECTIVES (Continued)
III. Standard Manufacturing Process Revision
Aroclor
Pyranols
Pydrauls
125V10J6 Xylene Mix
a. Variable Analysis b. Key Variables
Current-Batch 10/66 Cont.
9/68 Rev. 9/1/70
ft
Current-10/66 Rev. 11/1/70
tt '
Current-10/66 .Rev.-12/1/70
rr
Current-None Rev.-12/1/70
t*
c. Documentation and
Reporting
.
rr
n;
W
.IV. Key Variable Control Instrumentation
.'
a. IFO
Complete
Complete
Complete
Complete
b. IPMO c PM Program
Complete 6/1/70
Complete 6/1/70
Complete 6/1/70
Complete 6/1/70
d. Control Setting Documentation
6/1/70
6/1/70
; 6/1/70
6/1/70
V. Operating Instructions
a. Revision
Current-10/66 Current 10/66 Current-10/66
Rev. 6/1/70
Rev. 7/1/70
Rev. 7/1/70
Current-10/66 Rev. 7/1/70
b. Operator Training
9/1/70
9/1/70
9/1/70
9/1/70
VI. Management System Same as
a. Reporting System II c. 5/1/70
5/1/70
5/1/70
5/1/70
MONS 0 5 5 7 3 3
b. Process Control Co:rmittee
c. Process Avdit
7/1/70 8/1/70
7/1/70 8/1/70
7/1/70 8/1/70
7/1/70 8/1/70
MONSANTO COMPANY ORGANIC CHEMICAL DIVISION
STANDARD MANUFACTURING PROCESS
FOR
PYRANOLS DEPT. 259
.
INERTEENS
DEPT. 259
FR-0
DEPT. 259
Supersedes:
Standard Manufacturing Process for the of Pyranols and Inerteens in Department A-2A6, Dated October, 1966, and all amendments.
Prepared by: R. M. McCutchan
i\/.| , : 1 '
Approved by:
__
*
General ManufacTurlmJ'supTr
'}i/(Z
Research
Issued: Dtcember, 1970 Copy ___ .fl___ of
Manufacturing Manage"
This process Is the property of the Monsanto Company end the recipient Is responsible for its safekeeping. It contains confidential lr.fo:-r,a"1 of Monsanto Company which must not be reproduced, revealed to coauthor! persons or sen:, outside the company without proper authorization. Elt'retain in a secure file or return to the Standard Documents Departu-vnt.
HONS 055559
DISTRIBUTION SHEET 1. Technical Information Center 2. Technical Information Center 3. Record Center
Manufacturing Manager 5. Manufacturing Superintendent - W.O.K. 6. W.G.K. Department Supervisor 7. W.O.K. Technical Service Department 8. W.G.K. Process Research 9. W.G.K. Library 10. D. Danna - G.O'. 11. D. Danna - 0.0. 12. D. Danna - G.O. _ 13. Extra 14. Extra 15. Extra
HONS 055560
AMENDING RECORD SHEET MONS 055561
SECTION I SECTION II SECTION III SECTION IV APPENDIX A APPENDIX B
APPENDIX C APPENDIX D APPENDIX E APPENDIX F APPENDIX G APPENDIX Vi APPENDIX I APPENDIX J APPENDIX K APPENDIX L APPENDIX M APPENDIX N
TABLE OF CONTENTS Index Synopsis of Process Process Flow Sheet Process in Detail Comments on Process Equipment List Finished Goods and Raw Material Specifications Physical Constants Utilities Personnel Packaging and Shipping Material Balance Product Losses Process Control Safety and Toxicity Background Information Time Cycle and Capacity Quality Considerations Miscellaneous
. _
Page
MONS 055562
DEPT. 259 - STANDARD MANUFACTURING PROCESS
Pyranols, Inerteens, FR-0
' .......
SECTION I
SYNOPSIS OF PROCESS
Pyranol and Inerteen are tradenames used to designate mixtures of Arool or and either trichlorobenzene (TCB) or tri-tetrachlorobenzene (TTCB). A chloride scavenger, glycidyl phenyl ether or unox epoxide 221 is also added.
Pyranols are used as a dielectric In electrical equipment (transformers), and particularly as a transformer cooling medium. The addition of TCB or TTCB to the Aroclor increases fludlty of the blend 8t only a slight expense to Its electrical properties. Extreme care is used In the production of pyranol blends because the customer specifications are very stringent.
the present time four electrical grade blends are made. They
Common Name
.1 Inerteen 54201 CM .2 Inerteen 70/30
3- Inerteen PPO 4. Pyranol A13B3B
Other Names
Inerteen 100-42, 1242 PPO Inerteen 54201 KA, 1254 PPO
--1260 PPO
One other blend, Therminol PR-0, Is included in this SMP because its components are similar to the electrical grade blends listed above. Therminol FR-0 is a low temperature heat transfer fluid and is not considered an electrical grade product.
The proportion of components blended to manufacture the various blends are listed below:
Wt. %
Inerteen
Product
54201 CM
TCB
TTCB Aroclor 1242
-- ------ '
Aroclor 1254
--
Aroclor 1260 Unox Epoxide
----
Olycldyl Phenyl 0.20
Ether
Inerteen -.70/30
30 --
.....
70 -- --
0.20
Inerteen PPO 40 ' --
--
__
60 --
0.20
Pyranol A13B3B
--
55
__
45 0.125 --
Therminol FR-0 ...
20 80
__
-- --
Primary chemical reactions are absent in the production of these
blends. The manufacturing steps are blending, earth treatment and filtration, and packaging.
Blending is a simple mixing operation. Small adjustments are necessary until proper specific gravity and refractive index are obtained. To Improve electrical properties, a small amount of
attapulgus earth is added to the blend and subsequently filtered out. The electrical grade products are sold in tank cars or in drums of 55 gal, 30 ga., and 5 gal. Therminol FR-0 is sold in trailers or 55 gallon drums.
MONS 055563
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteena, FR-0 SECTION I (cont'd.) SYNOPSIS OF PROCESS The Pyranol tradename Is used by the General Electric Corporation and Inerteen by the Westinghouse Electric Corporation.
HONS 05556*.
DEPT. g5Q - STANDARD MANUFACTURING PROCESS Pvranols. Inerteens. FR-0
SECTION II
FLOW SHEETS
.
Flow sheets for the blending operations are hl-llghted on the following department drawings.
HONS 055565
HONS 055566
HCNS 055567
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, FR-0
SECTION III PROCESS IN DETAIL
'
A. BLEND CALCULATION
The first step In making a blend Is to determine the batch size desired, and the weight of each major component based on the percentages listed in Section I. Using these weights, and the known specific gravity and refractive Index of both the Aroclor and chlorobenzene, the theoretical S. 0. and index of the blend is calculated. This is done simply by . weighted averages. By trial and error the ratio of the major components Is shifted slightly, If necessary, so that both specific gravity and refractive Index will be as near as
possible to the middle of their respective specification ranges
B. BLENDING
The major raw materials are pumped to the mix tank (#2 or if},), the chlorobenzene first. This Is to avoid the more viscous Aroclor from clinging to the walls and bottom of the tank. The mix tank contents are agitated for at least four hours after the major components have been added. The blend Is heated to 90-100C during this time. A 16 oz. control sample Is taken for S. G. and index. If adjustments are needed they are calculated In the same way as the original batch. Once S. G. and index are In spec., the chloride scavenger (glycldyl phenyl ether or unox epoxide) Is added based on the total batch weight.
C. EARTH TREATMENT AND FILTRATION
.
After agitating for another A hours a final sample of three
5-pint bottles is taken. If all analyses are In specification,
and the power factor at 60 cycles Is under
and the
resistivity Is at least 1500 x 10, then the product is ready
for packaging. (These quality levels have been set within the
department.) If this quality Is not met, then 20-25 lbs. of
attapulgus earth Is added to the blend, agitated for A hours,
and circulated through a filter for 1-2 hrs. Samples are
taken and reanalyzed for electrical properties. This earth
treatment step can be repeated as often as necessary. The
3.0$ power factor and 1500 x 10 resistivity levels were set
for efficiency of operation only (See Cl in "Comments on
Process" section. The critical analysis Is the tank car
analysis.
D. PACKAGING
MONS 055568
See Appendix F for container sizes and product welgnts.
In the case of tank cars or trailers, product samples are token from the car or trailer and an analysis run. If a certificate of analysis is requested, this is the one used. _ Drum samples are not taken, but merely identified by lot number
which correlates to a mix tank analysis.
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pvranols, Inerteens, FR-0
SECTION IV
A, RAW MATERIAL YIELDS
In calculating yields, the Aroclor yield is assumed to be 100# and the chlorobenzene yield calculated on that basis. Therefore, minor losses will show up as chlorobenzene yields less than 100#. Actual material losses are very small, an estimated 0.2#. Very small losses occur at the mix tank vents, leaking pumps, and in discarded filter cartridges. The only significant loss occurs when a tank car is overfilled. A yield loss (but not a material loss) occurs when drums are . filled to more than the indicated net weight.
Chlorobenzene yields do not necessarily reflect only the above mentioned losses. The yields also reflect the specific gravities and refractive indices of the chlorobenzenes and the Aroclors. This is because the finished product is made to meet certain specification ranges, not a certain weight ratio. Therefore, it is possible to have below 100#chlorobenzene yields even with no material losses. Likewise, yields over 100# can be legitimate and do occur.
B. CAPACITY
-
The rated monthly capacity of Dept. 259 for producing Pyranols is 1.68M lbs. The first time this level of production was demonstrated 'was in October, 1970, when 2.08M lbs. were produced. A more "normal" level is 1.0-1.3M lbs./mo. The primary bottleneck to higher production is the fact that the two mix tanks are also the only storage tanks. Loading or drumming is done directly from the mix tanks. Response to orders with little or no lead time is poor because four blends are made in only two mix tanks.
A few minor points:
1. The mix tanks should be agitated and circulated while charging as well as afterwards to reduce actual blending time. If this is done, it was decided after evaluation that in-line stationary mixer was not needed.
2. There are no problems in making a batch on top of a heel. At times this can be done advantageously in order to get to the next batch more quickly.
3. Brodie meters were installed to meter Aroclor and chloro benzenes to the mix tanks. After much testing it was decided that the reliability of gauge board level indicators more than offset the time saving offered by the meters.
MONS 055569
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pvranols, Inerteens, FR-0
SECTION XV (cont'd.)
C. QUALITY
Quality Is singularly the most Important consideration in the production of electrical grade blends. The pro duction of off-grade blends has resulted in much controversy, extended correspondence, and chemical research. No attempt will be made to cover the entire scope of the quality problem. Some of the factors related to quality are discussed briefly:
1. Electrical Properties - A rather arbitrary "mix tank specification" has been observed by the department for power factor @ 60 cycles and resistivity. This is a maximum of 3-0# power factor and a minimum of 1500 x ic9 resistivity. This is more stringent than the formal plant specification because these two analyses must be in specification jjv the tank csr. Normally these electrical properties drop when pumping from tank to tank, or tank to car. The reason for this is unknown, but the suspicion is alviays contamination. It Is also recognized that proper sampling is extremely important.
2. MoiEture - The moisture content of Pyranol and Inerteen batches can be reduced to 10-15 PPm by blowing the batches with Ng supplied by Dept. 2b6. In the blowing operation, the batch should not be heated above 100C for prolonged periods to prevent TCB or TTCB vaporization losses. The vaporization loss of sufficient TCB or TTCB may throw the blend out of specification on specific gravity and refractiv index and require a TCB or TTCB adjustment.
. Pyranols 8nd Inerteens have an affinity for moisture. Tanks and containers should be kept closed when possible.
When a low moisture content has been achieved and the material is to be drummed, a high temperature (120ClbOC) is better for maintaining the low H,,0 level than is continued blowing with Ug. It should be noted, however, that if the drums or cans are quite full at normal temperatures, at the higher temperatures the required net weights cannot be met. This recently caused changing the 5 gallon A-13B3B and Inerteen PPO cans from 65 lbs. to 60 lbs.
3. Early in 1970 the refractive index specification for A13B3B and inerteen PPO was widened. Prior to this the specific gravity usually had to be very near the low end of the range in order that the refractive index be in specification on the high side. In other words, the two ranges did not correlate well with each other.
055570 HONS
DEPT. 253 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, FR-0
SECTION IV (cont'd.)
C. QUALITY (cont'd.)
4. Attapulgus earth tends to remove a small amount of the glycldyl phenyl ether In a batch. If a batch Is extensively earth treated after the scavenger has been added, there should be a final re-analysls for the glycldyl phenyl ether.The only known way of removing excess scavenger is by earth treatment or by lowering the percentage b^ compositing a larger batch.
5. Chloride Scavenger - Many of the Inorganic chloride troubles of the past have been traced to the chloride scavenger. Tin tetraphenyl is no longer used as a chloride scavenger because the mixes would not pass the 0.1 ppm inorganic chloride specification In many Instances. Unstable glycldyl phenyl ether has been responsible for offgrade Inerteen PPO in the past. Inerteen batches with chloride concentrations as high as O.30 ppm have been successfully treated to reduce the chloride concentration to 0.1 ppm by the addition of 10-20 pounds of Attapulgus earth to the mix tank and circulating the batch through the filter.
6. Raw Material Stability - During 19*17, considerable difficulty was encountered producing pyranosl that would pass the 0.1 ppm specification on inorganic chlorides. After extensive research work, the difficulty was traced to the Instability of the raw material trlchlorobzenene.
At the present time, so many variations In the final analysis are `experienced that it Is virtually Impossible to track down where the electrical properties degrade. The variations are probably due to sampling variances, bottle contamination, atmospheric contamination In plant and laboratory, and personal analytical techniques. V/hen these difficulties are closer to a solution, the following improve ments should be evaluated:
(1) Earth treat or porocel treat TCB or TTCB before it Is blended with the Aroclor.
(2) Flush car to be loaded with high quality 1242 rinse, and then upgrade rinse between uses, or, load car with product and then circulate car contents through an absorber before shipping.
HONS 055571
Dept. gc;a - Equipment List Pvranols. Inerteensi FR-0 APPENDIX A
Item Equipment No. Name
* 142 #1 Blend Tank
Equipment Number
21-0779
143 #2 Blend Tank 144 Blend Pump
21-1399
19-1757 66-3718
152 #5 TCB Storage Tk. 21-1310
153 #5 TCB Storage Tank Pump
154 #3 Mix Tank
19-0929 66-0856
21-3526
Description
Tank made by Graver. DWG. E-862. Welded steel tank, 7' dla. x 7' high, dished heads 1/2", shell 3/8". All surfaces sprayed with .005" zinc, then .003" tin. 2" xHy pipe coll. Cast bronze stirrer and bronze shaft. Test pressure of tank is 60# hydro., coil is 3# hydro, pressure. Capacity 2,000 gals.
Same as Item No. 142.
Taber Pump 304 s.s., 2 1 x 1 1/2 Capacity is 60 gpm, 100 head. Motor is 10 hp, 1800 rpm.
Tank made by Leader Iron Works. C-609. 10' OD x 26' long on Str side, dished heads, shell 1/2" head 1/16". Test of tank is 6C/ and coil is 300# hydro pressure. All coils, supports, and inside surface sprayed with . 00p" zinc and .003 tin.
Taber Vert. sub. pump tyce L-2. 2 1/2" x 2" length 4'7" Cap. 50 gpm at 40' static head. Motor is 3 HP, 1800 RPM.
Alpha Tank 12' x" dia. x 22' high. 20,000 gal. stg. capacity Aluminum constructed. Dwg. TSD-3011.
HONS 055S72
Dept. g<sg - Equipment List
Pvranols. Iri<Lrteens', FR-Q
Item Equipment No. Name
Equipment Number
**155 #1 Mix Tk. Pump
19-3172 66-2651
**159 #1 Mix Tank
21-0321 66-2168
160 #3 Mix Tank Pump
162 #6 TTCB Storage
19-1540 66-3133
21-0848
163 TTCB Pump
19-1111 66-0745
164 #2 Mix Tank
21-2621
23-4109 66-4592
165 Pyranol Pump
19-2179
#2 Mix Tank Pump 66-2971
166 18" Sparkler
15-0172
Filter for #2 Mix
Tank
.
174 TCB and TTCB
19-1111
Tank car unloading
pump
187 18" sparkler
15-
filter for #3 mix
tank
Description
Durco pump model WH 2 alloy construction 2" x 1 1/2" 8" impeller. Cap. 160 gpm at 55' head.
Tank (Nooter), Dwg. D-6455, 141 O.D. x 10' high. 3/8" shell, steel construction. Capacity is 15,000 gallons. Agitator motor is 7-1/2 H.P.,1750 R.P.M.
Taber Horiz.,Cent. Pump 3<54 s.S. 2" suction, 1 1/2" discharge. Motor is 10 H.P.,1750 RPM.
Tank made by Graver. Dwg. E4413. 8' ID x 25'6" long. Steam coil. Capacity 9,500 gals.
Blackmer pump #5-0L.All iron steam jacketed pump with Cl base plate. Motor is 7 1/2 HP, 1750 RPM.
Vertical cylindrical steel tank 10'6" ID x 23'0" high. Capacity 14,800 gal. Lightening mixer. Motor is 7 1/2 HP, 1800 RPM. Capacity 14,580 gals.
Taber pump. 304 s.s. 2" suction 1 1/2" discharge. Motor is 10 HP, 1745 RPM.
Made by Sparkler Mfg. Co.,Model 18-D-12. Filter is all bronze construction.
Blackmer Model 3202 Cast Iron. 2" x 2" suction and discharge.
Same as Item 166.
HONS 055573
DEPT. 259 - Equipment List
Pyranols, Inerteens, FR-0
ITEM NO. -"
***l60
***1 65 145
EQUIPMENT NAME
FILTER(at loading dock,Spot #3, Track 10A)
EQUIPMENT NO. --
#2 mix tank pump
52- 2875
3 mix tank pump
52-2875
36" Sparkler Filter 15-0238 (no longer used)
DESCRIPTION
Alsop filter model no. PAK 125-4, 316s.s.,6000 in|r filtration area, 840 ind volume.
Durco 2x1 1/2 x 9 1/2 (will take up to 11 1/2" Impeller), Alloy 20. Motor is 7-5 HP, 1750 rpi
Same as Item No. 160.
33-D-12 horizontal plate filter, 30 4s.s., jacket tested for 30 psi.
* These are Dept. 246 items and are used for blends only when a small batch is needed (2000 gal. or less).
*# Used for Pydraul blends.
*#* New Item - 165 - placed old Item 160 in October, 1970. New Item 160 replaced old Item 165 in December, 1970.
HONS 055574
APPENDIX B SPECIFICATIONS
The following isa list of the raw materials used for the manufacture of Pyranols and Inerteens. Specification sheets that are available are Included for the materials.
MATERIAL CODE
RAW MATERIAL
58500
60200
81105 81103 61325 81101 36100 19409 43101
Tri-Tetrachlorobenzene Trichlorobenzene Aroclor 1260
Aroclor 1254 Unox Epoxide 221 Aroclor 1242
Olycidyl Phenyl Ether Attapulgus Earth Nitrogen
*
The following is a list of the finished products manufactured in Department 259* Specification sheets are Included.
PRODUCT CODE
PRODUCT
81110
81097 81092 81098
81109
Inerteen 54201CM Pyranol AI3B3B Inerteen PPO Inerteen 70/30 Thermlnol, FR-0
MONS 055575
Monsanto
SPECIFICATION
PRODUCTION
A. P:. Lelsv
PROCUREMENT
6. Laverle
GENERAL DESCRIPTION
'
MATERIAL CODE
58500
PLANT
W.G.K.
date erreertve
5/70
Tri-Tetrachlorocor.zor.e "il
USING DEPTS.
259
tUPPL/KP
Hooker Electrochemical
APPROVALS R6.SAKCH
W. R. Richard
QtVALIT Y CONTROL (Chitt Chn\t*{)
R. M. Blowers
CltEMIC At POMUL A
Mixture
C MAR A Cl CRIATIC
VNFESTR.TCTED INFORMATION
|3 x 5 Pt. Amber Bottles
LIMIT*
I
' Ml
Color
APHA 15, max.
Conoltlon
Clear
(R) Sp.Or.@15>5/15>5C Acidity (mg.KOH/g.)
1.510-1.522 0.014, max.
Moisture (H?0)
75 ppm, max.
(K) Refractive Index @25C
1.5775-1.5790
Free Chlorides
O.lOppm, max.
Crystallizing Point
-15C or lower
Last Crystal Point
0C, max.
Dielectric Strength@25C
30KV, min.
Distillation Range(ASTM D-85O,, Modified)
First Drop
210C, min.
555 by volume
215C, min.
65$ nv volume
22oC, min.
90$ by volume
255C, max.
55$ by volume
265C, max.
Dry Point
278c, max.
10,103
10,105 10,114
10,087
, ?10,620
10 12 10,110 12,035
12,033 11,605
12.03L'
Corrosion Test 6 hrc. @210C
with bright aluminum foil
Change in weight of A1
Color
.
Condition
Aeidlty(mg.KOH/g.)
Free Chlorides
Chemical Composition
Tri chlorobenzene
l,2,3,4Tetrachlorobenzene
1 / 2, 4,5Tetra chlorobenzene
Pentachlorobenzene
Fire Point
0.0$
APHA 100, max. Clear 0.014, max. O.lOppm, max.
58.5$, min. 26.0-29.0$ 3.0$, max. 5-5$, max. None to boiling point
10,126 10,1 10,1.; 10,C:. 10,1-'. 12, ci:
10,1.0
OEM HAL INFORMATION Dielectric. Constant 1000 cycles, 100C Viscosity @100F
4.8-5.1 28-32 SUS
HONS 055576
Certificate of analysis required on the above properties - to be tc the Cr.lef Chemist, W. G. Krummrlch Plant to arrive on or before
IK) ReullA. AmaIt.I,. All oihor. Anolyttil by ..quoit only.
Of Shipment.
WOK- >1.
r;joR5tiito
OROANIC C H K Ml C A L I DIVISION
RAW MATERIAL SPECIFICATION
TfToBTTTTToN . . ,
B-/-W.- Coriew/H. McCutchan
VKOCUAAMeNt
'
''
J. D. eyerie
___________
M*fCU .ore
60200
^UAhlT
WGK
oatk cryeenve
Trichlorcbon~?r.a
UJlf0 OtPl s.
259
11/13/70
Hooker
APPROVALS I RMCMICH
N. R. Richard
""""l OV)*L'TY CONTROL (UA/*.t ChtnUn)
I R, M. BloweriS
9 KNKRAL DESCRIPTION
CHIMIC *L rOAMUL A
TCB
C6H3CL3
AUAKAUPIA IPICA OP 11/20/68
chaaactahutic
UNRESTRICTED INFORMATION
Color
APHA 15, max.'
Condition
Clear
Sp. Or. @15.5/15.50
1.460 - 1.477
Acidity (mg. KOH/g,)
0,014, max,
Moisture (H2O)
75 ppm., max.
() Rofractlve Index @25DC
1.5680 - 1.5715
Free Chlorides
_ 0.10 ppm., max.
Crystallizing Point
10C, max.
Dleloetric Strength 25C _3__0__KV, _m__in_.
Distinction Range (ASTM D-850,Modified)
(corrected for Stem and Barometric Pressure)
First Drop
205C, min.
5$_by volume
210C, min.
50^ by volume
213C, min.
90# by volume
215C, min.
Corrosion Tost, 6 hro r.t
210C with bright aluminum
foil Chenge In weight of A1
0.0#
Color
APHA 200, max.
Condition
Clear
'
Acidity (mg. KOH/g.)
0.014, max,
Free Chlorides
0.10 ppm., max.
Monsanto Stability Tost
0.5 ppm., max.*
Hydrolysis Stability Tost C.5 ppm,, max,
Fire Point
None to boiling point
Fixed Chlorine
58.5/5, min.
*
10105 10105 10100 10109 10620 10125 10110 10107 II605 10103
10126
11503
112061722;.
10083
Eviry other car can be over 0.5 ppm but never over 1.0 ppm. Valuer, ov: 0.5 ppm to be cleared in advance.*
Certificate of Analysis required on the above properties - To be sen; to the Chief Chemist, W. 0. Krurrmrich Plant- to arrive on or befoie receipt of shipment.
(ft) ftoultn* Antyl, All lfm* Ar.tlyMd ky r*tvsil only.
HONS 055571
Monsanto
OROANlC CHEMICAL* OIVlHON
Krummrich & Anniston RAW MATERIAL SPECIFICATION
PRODUCTION
PROCURE MENT
oknkral description
MATERIAL COD3 '
61325
PLANT
V/GK k Ann.
O AT B EFFECTIVE
8/13/69
MATERIAL
EP- 221
UIH8 OCPTS. 259 WGK
27 Ann.
UPPLIER
Union Carbide
APPROVALS HE8CAKCH
V. ^ QUALITY CONTROL
R. Blowers
Ch*#>ltt) t Ron
CHEMICAL FORMULA
UPERtEOEl SPEC* OP
> AMPLE POR ANALYtll
1 - 16 os. W M Bottle
Hlggerson/Stit.rs
UNRESTRICTED INFORMATION
(R) Appea ranee
Clear liq., free from dirt fibers, or other contamination
(K) Assay Color
88%, min. 150 APHA, max .
Total Free Chlorides
1 0 ppm, max.
Refractive Index @25DC.
Report
Moistu re
0, 1%, max.
Acidity
0, 2 mg KOH/gm, max .
Sp. Gr. @90/15.5*C.
Report
13019
13017 1008-1 13021 13000 lOi 10C .37 130;
Supplier's certificate of ant. /sis to'be sent on day of shipment tot
Chief Chemist, Monsanto Co., ">i
, 111.
OR Chief Chemist Monsanto Co. , Anniston, Ala.
(R) Poulin* An*ly$l, All olhoro Ar\aly**4 by r<p>**i only.
m0NS 055578
AOOU^TtON
A. E. I-71-v
r'RoCVRiMttWT
.
OimilAl PCWtPTtCW
SHio*
mol wt, 150, 17
u^triiKoc* r**ec or
5/26/66 CHAftAevoaiirie
UNCLASSIFIED INFORMATION
AtUAACH
V.', R. R V - ^
QUALITY CONTROL (Ct\Ut
R. Blowers CHEMICAL POfcXtULA
'CHZ
\77
7iiauco y
,
|Higgerson/Sti tes
(R) Sp. Or. @20/20 C , (R) Total Chlorine (as Cl ) GENERAL INFORMATION
1.105 - 1.115 40 ppm, max.
11,664 12, 510
At the present time the material being supplied to WGK for use in the manufacturing of Westinghouse Inerteen PPO, is a commercial Grade of Glycidyl Phenyl Ether. In addition to the 2 tests shown above, the supplier's specification lists:
Purity (Based on Epoxide Content, per cent by weight
. 98%, max,
- --
Color
30 APHA, max.1
The supplier's Technical Bulletin shows the following Physical Properties for the Refined Grade.
Boiling Point @ 760 mm. Melting Point Flash Point Refractive Index @20'C. Viscosity @20 *C ,
30'C.
245"C. . 3, 5C, 175*F, 1,5314 7,05 cs. 4. 88 cs.
11,862 11,861
11,86 3
Supplier's certificate of analysis to be sent on day of shipment to; Chief Chemist, Monsanto Co., y.-.pgnt 111,
(ftf Xtvtl.'i
*ior*'*
All
.
Ar-.iyt.:* fc?
tnly.
HONS 055579
Monsanto . .
W. G. Krurhmrich Plant RAW MATERIAL SPECIFICATION
PRODUCTION
PnOCUAEMtNT
J. Leyerle
OKNCRAt OCICRIPTtON
19409MATEniAL COt>
material Attapulgus ,,irth <?G0/UP
PLANT
WGK.
UtINS OCPTI.
246 ( 259
OAT* EFFECTIVE
2/3/69-
&lUFFUER Mineral
Chemical Phillips Corp,
APPROVALS *rT *rcm
. VI ^ *1 ->Prr R'IUITFR.|'8PI fCht*t Chttnltt)
R. Blowers
CHKMtC At FQrtMUL A
Clay
1/21/66
CHAAACTCRHTIC
2 x 16 y.. V/,. M. Bottles . | Htp.Rerson/St lt'-o
METHOD
UNRESTRICTED INFORMATION (R) Volatile Matter (at 950*C.) (R) Mesh Tost:
Through USS 325
6 - 8% 90%, min.
This material is not accepted without the supplier's analysis of the above properties.
W floiitlnt
AU o:h: .1nolyttd ty
only.
HONS 055580
Mensar/io
OhthHIC CMCMtWAL* OtVUtOI
R AW MATERIAL SPECIFICATION
MATERIAL COrC
43099 PLANT
..
WGK DATS CKPKCTIVK
3/29/68
MATtHUL
Nitrogen Gas USING tlKPTI.
See Below (3) UPPWCA
Air Reduction Sales Co.
"
tkMucInoH
O.D.D.
PMOCURKMINT
H. Denser
APPHOVALS
T. W. D.
E.D.M.
J.M.C.
kmiascm R H. Mills
E.L. M.
J.A.S.
QUALITY COMTftOL (Ch.'lt C/.tttllO
.
W. J, Gresham
'
ODeG.
SN&HAL OflSCMPTlOu
' CHEMICAL FORMULA
'
'
'
Grade - O. P. Special Nitrogen
lUPIMUOKI SPECS OP
2/18/65 CflAPACTCniATie
SAMPLE PON ANALYSIS LIMITS
itsuto or L. E, Hornback METHOD
Assay (1) Oxygen Hydrogen Dew Point
.
>
Nitrogen Argon Oxygen Carbon Dioxide Acetylene
99.9%, min. ' 0. 1%, max.
0% -76*F.
'
Typical Analysis
99.78% 0,12% 0, 1%
. .00005%
.00005%
'
(2)
(1) Nitrogen plus inert rare gviec
(2) Any analyses to be obtained front sun-tlicr on request.
(3) 213, 244, 246, 247, A-255, A-256, 259, 267, 270, B-270 l: 281.
(t) .'U.i.'Ja* AMtfr)i, tJI *0KI14
by roa>J
yv p r-.ius
HONS 055581
Monsanto
OAOAHlC CHtMICAll DIVISION
KRUMMRICH AND ANNISTON
FINISHED PRODUCT SPECIFICATION
P*ObOtVI6N A . E I-eisv
trrzrw. E. Ault
ICSftAb C.lt
'CA.'nr'oV clor-- 1242, Electr-ic.
WGK 246
WGK
|81101
wnViYrztmv----carcyera """
- 10/22/69 fiPVt-.W AUO
1 104 0-24 0-04/11/16- 03/09
1 nho r.'U-
.. .... 1 R,.M. Blowers . ...
T. Bell
pc "JEW*
m>v nr *wfciiw^0s>c3J.a3vij.v^
8/1/69
| 3 x 5 pt. Amber Bottles I Hiqqerson/Stites
CHARA6T(lATie
*J&3f
.
UNRESTRICTED INFORMATION
WGK
ANNISTON
<R> Color (APHA) 1
.40, max.
(R) Condition (R) . Sp.Gr. 8 25/15.5C. (R) Acidity (rag. KOH/g.)
. Clear 1.381 - 1.392 0.010, max.
(R) Moisture (HjO)
35 ppm., max.
(R) Refractive Index 8 25C. 1.6240 - 1.6260
(R) Inorganic (Free)
Chlorides
0.05 ppm., max.
(R) Pour Point (R) Dielectric Constant
-14'C. or Lower 4.70 - 4.90
(1000 cycles @ 100C.)
(R) Resistivity
50Q, min.
(500 VDC 8 lOO'C. 0.1" Gap)
As OHM-CM x 109
(R) Hydrolysis Stability Test 0.5 ppm, max. (As Chlorides)
(R) Monsanto Stability Test (As Chlorides)
0.4 ppm., max.
(R) Distillation Range (ASTM D-20, Corrected)
10% Distilled by wt.
325 C. , min.
90% Distilled by wt.
360C., max.
Sulfates"
None
Dielectric Strength
8 25C.
35 KV, min.
Dash Point ("F)
338 - 392
fire Point
None
Corrosion Test
(6 hrs. 8 210C. with bright
aluminum foil)
Change in wt. of AL %
0.0
A.C. Color (APHA)
60, max.
A.C. Condition
Clear
A.C. Acidity (mg. KOH/g.) 0.010, max.
A.C. Inorganic (Free)
0.05 ppm., max.
Chlorides
vise. 8 100F. (SUS)
82 - 92
"
10084
10084 10114 10087
10620 10125
14-44-54 G-l 14-49-54 14-42-54 14-53-54 14-34-54
12741 -- 014
10115 14-47-54 11608 14-36-54
11607 14-35-57
12672 11503 10117
010 14-61-57 14-31-54
12169
11605 10123 10123 10126
043
14-28-54 14-28-54 14-55-57
10084 10084 10087 12741
10086
14-44-54 C-l 14-42-54 014
14- 4-53
IB) B*!( AMfotU, AU M&trs Aneiy$tt &r rag.iMl Only
OVER
HONS 055582
GENERAL INFORMATION
Specific Heat 25 *C, Coefficient of Expansion
(29 - 65*C) Fixed Chlorine Power Factor @ lOO'C,
60 cyclee 1000 cydeB
0. 30 0, 00068 cc/'C.
42.5 - 43.5* ( Typical Values)
5 0,30
SPECIAL CUSTOMER REQUIREMENTS
General Electric .
Thermal Chemical Chlorides
0.65 ppm,, max,
V/cotlnghouae
Hydrolizable Chlori,ne (weetinghouee Stability Test)
1.0 ppm., max.
12722 T-2219
HONS 055583
I.IVIOulUU
0HOAHIC CHtMICAL* DIVISION
FINISHED PRODUCT SPECIFICATION
PRODUCTION
A . E. Lelsy pALki
W. E. Ault
CNKRAL 0**c(PTin
'
.Also called Pyranol 1476
Aroclor 1254 Electrical u
pa'oouc i'ccoT"
I 24/
IflUVYICcKt,ffacntidivzAn' n,
81105 IAlUicooc
82613
Sales
11/4/68; APPROVALS
J lgM=290>0/3Ll/]6-n^/nQ ----.--------------------
Vi OUAUYV
RCO. NTRROiLch(Cahlredt Ch*nleO
R. M, Blowers
T. Bell
C HQ MIC At FORMULA
MOV. WT,
PUPtniiDKi iPtc*. or 6/28/65
C H AH AC T KHItT 1C
rR AHALYPli 3x5 pt. Amber Bottles E, McEntire/ LIMITS
.SlltOS MT lot-"1
UNRESTRICTED INFORMATION
(R) (r) (r (r) (r) (R) (r) (r) (R)
(R)
(R)
(R)
(R)
Color, APHA
50, max.
Condition
Clear
Sp. Or,. 65/l5.5C
1.495 - I.505
Acidity (mg. KOH/gm.) Moisture (HeO)
0.010, max. 35 ppm, max.
Refractive Index @25C
1.6370 - 1,6390
Inorganic (Free) Chlorides 0.05 pom., max,
Pour Point
7 - 12feC
Dielectric Constant
4.15 - 4^5
(1000 cycles 100C)
Resistivity
500, min.
(500 VDC @100C 0.1" GAP)
as OHM-CM x 109
Hydrolysis Stability Test 1.0 ppm,, max.
(as Chlorides)
Monsanto Stability Test
0.5 ppm., max.
(ae Chlorides)
Dletillf.tlon Range
(ASTIi D-20, Corrected)
10# Distilled by Wt,
366 - 378C
50$ Distilled by Wt, 90# Distilled by Wt.
371 - 383C 379 - 394C
Sulfates
Hone
Dielectric Strength @25C 35KV, min.
Flash Point
None
Fire Point
Hone
Vise. 210F (SUS) ,
44-48
Corrosion Test
'
(6 hrs 210C with bright
aluminum foil)
Change in wt. of Al (#)
0.0
A. C. Color, AP1IA
60, max.
A, C. Condition
Clear
A. C. Acidity (mg.KOH/g.) 0,010, max.
A. C, Inorganic (Free) Chlorides
0,05 ppm., max.
WGK T5o84 10084 10114 10087 10620 10125 12741 10115 11608
11607
12672
11503
10117
12169 11605 1012> 10123 10086 10126
' 10084 10084 IOO87 10118
Ann. I^T4-5' 0-1 14-49-5' 14-42-5' 14-53-5' 14-34-5' 014 14-27-5' 14-36-5'
14-35-5?
010
14-61-57
14-31-5-
043 14-28-5 1 14-28-5;. 14-4-52 14-55-57
14 -44-5'. G-l 14-42-54 010
flu He
Anoly*
A II other* AnalytcA by rtrjueit Only MMBmeuctsL'vr.'caVB.sc irwci T-rtTv*-
MONS 055584
SPECIAL CUSTOMER REQUIREMENT
Cornell - Dublller
Resistivity (500 VDC 100C 0.1" GAP as OHM-CM x 109)
GENERAL INFORMATION
Specific Heat @25C Coefficient of Expansion
(25-65c) Fixed Chlorine
1500, min.
0.27 0.00066 cc/C 54.5 - 55.5*
11607
14-55-54
HONS 055585
Anniston And Krummrich FINISHED PRODUCT SPECIFICATION
SkobuerlOH A. E, Leisy
rrtn---------------- "--
w.. JSU^alA------
KNSMAt &KCftl*TlON
Ann.
82614-Ann.
SSaales
fginri'^ifenja:------- - I-----------------------------------
JL2mm.
lMQ-2.9P.-Q4/ll/lii-03-nq
ptMETWH---------------- :----------------------- --
. s}LrJuJslXjZii?.$&..,. SiiAur? coAtruwu <i.5GVMtffti>
.S^-iiL--lUaitf&EST-. Bpii
MOL WT.
pic.w"niiocii
op
S/25/66
UNRESTRICTED INFORMATION
PC* A&At,r4
3 x S pt. Amber Bottles LIMIT*
() Color (APHA) <R> Condition (R) Sp. Gr. @ 90.15.5C R) Acidity (mg KOH/g.) i R) Moisture (H2O) (ppm)
(R) Viscosity @ 210"F. (SUS)
(R) Refractive Index 8 25C. (R) Inorganic (Free) Chlorides (R) Pour Point (C) (R) Distillation Range
(ASTM D-20, Corrected)
104 Distilled by wt. 504 Distilled by wt. 904 Distilled by wt.
(R) Corrosion Test (6 hrs. @ 210C. with
bright aluminum foil)
(R) Change in weight of A1 (4) (R) A.C. Color (APHA) (R) A.C. Condition (R) A.C. Acidity (mg. KOH/g.) (R) A.C. Inorganic (Free)
Chlorides
Flash Point
Fire Point
Fixed Chlorine (4)
(R) Dielectric Strength 1? 50C.
(R) Resistivity (500 VDC @ 100*C. 0.1" gas as ohm-cm x 10)
(R) Dielectric Constant 1000 cycles, 10QC.
150, max. Clear 1.555 - 1.566 0,014, max. 35, max. 72 - 78 1.6455 - 1.6470 0.05 ppm, max. 25 - 34
385 - 398 C. 390 - 404 C. 400 - 420oC.
0.0
.
150, max.
Clear
0.014, max.
0.05 ppm, max. None None 59.5 - 60.5
30 K.V., min. 500, min.
3.6 - 3.8
Hiqgerson/Stites cirtco
10084 10084 10114 10087 10620 10086 10125 10118 4P115 10117
10126
10084 10084 10087
10118 10123 10123 10088
11605 11607
11607
' (R) Rouiint Analyst, All eihert AnolytcJ by MqutH Only
OVER
HONS 055566
Aroclor 1260 Electrical Grade (Cont'd.)
2.
RESTRICTED INFORMATION
Limits
Method
(R) Monsanto Stability Test (As Chlorides in ppm.)
0.7, max.
11503
GENERAL INFORMATION
(R) Evaporation Loss after 6 hrs. @ 100C. (%)
0.2, max.
10116
(R) Stability test - after 30
days @ 100C. in glass
No liberation of
sealed in air.
chlorine or chlorides
HONS 055587
lJ
OROANIC CutHtC ALS DIVISION
*.<* d
FINISHED PRODUCT SPECIFICATION
FKo&uction
__ IVCVx'XA 5A201 c.;
7* L AH~f
"
Anniston Tnmr cTviv
r' ^"c*yul'v ccTC 826.90 `SALIM COO'.
.CLls_
2-22-G8
APPROVAL*
I 1050-215- 16-09
TSllSCAMCM
C'U-,'7
H. L Williams /g/ H, L, Milllams 10/23/68 | V, ft. IUr.lnrd. /,n/ U,` A, J1.ic'itvd \\I\h/jO
IALC*1 1
1 r r' 'JI"~
' " 1 r
* jouAUt V COH-U\cC~<CSlp1 O.-.Mlil)
-
H, E, Ault /a/ V, B, Ault 11/19/68| G, VI, Hiller /s/ G. W. )I1 Her 10/22/CO
6CNCMAL DCICRlPTlON
ChWMICAL POflklULA
99.87. Aroclor 1242 0,2% Phenoxypropene Oxide MOL WT.
UPEftlKOCS SPEC*. OP
c mar ac r cmtT ie
AMPLE POP ANALVOl* 3x5 pt. Amber bottles
LIMITS
ItfiUCOftV
0. V. Hiller
'
METHOD
.
(R> Color, APHA
60 Max.
(it) Condition
Clear
(R) Specific Gravity @ 25/15 5C (R) Acidity (Mg KOtl/g)
1.301-1.392 0.010 Max.
(R) Moloturc, ppm
35 Max,
(R) Refractive Indent @ 25C
1.6240-1I02GO
(ft) Inorganic (Free) Chlorides, ppm (R) Pour Point, *C
0.05 liax. -17 or lower
(K)`Rcfilfltlvity, ohu-cia
100 x 10s Min.
500 VDO Q 100*0 0.1" Gnp
(R) Distillation Kongo (ASH! I -20,
. corrected)
10% Distilled by vt.
325`C Min.
. 90% Distilled by vt. (R) Dielectric Strength @ 25'C (R) Fire Point
360*C l!ax, 35 KV Min. None to Boiling
(R) Viscosity @ 100`F, SU3
82-92
(R) Phenoxypropene Oxide, % (R) Corrosion Toot 6 hrc. @ 210eC
0.18-0.22
with bright Al foil
Change ln vt,' of Al foil, % 0.0
Color, APHA Condition Acidity (Mg KOH/g)
100 Ifcx. Clear 0.010 Hex.
Inorganic (Free) Chloridss.ppto 0.05 Mix.
046 G-l 052 050 047 048 045 053 121
054
043 114 049 071 136
046 G-l 050 014
(H) Rontint Analysis, All othrts Anrlyttd by if<ju#si Only
MOWS 055588
Monsanto
0ROANJC CH MIC
OlVIllON
Anniston s. W.G.Krummrich
FINISHED PRODUCT SPECIFICATION
USobwff 15h
A E. Leis.v
{*(. '
"** '
... .....' ...
W, E. Ault_______________________ DMCRIRTtON
Mixture of:
| Transformer Pyr&nol A13E3B *
L .. ... .. _
rL`H,Anniston
___ ' - -vnboucT
i__________|_u____________ 2S>
1 WCK 6tVriroTrf)vr---------
81097 'IM.U4
*WGk' i
. .SAI.r.55 1 r mi IT
1050-300-16-03/09
/ APMVV All 1 " " ~ Tar"i arc"m
W ,R. _Reha.ui---------------------------------------OvAt.irr eoNrNOL (Chtat Ch*it'
_________ R. BlowersT- Bell
CHlMie *L ^OHMULA
45% Aroclor 1260 55% Tri-Tetrachlorobenzene EP-221
UCAKD(I ASICI. or
U/69
AHOLK rOA ANAUVStO
3 x 5 pt. Amber bottles
tTniveo av Higgereon/Stitae
C NAAlf T IflllT
UNRESTRICTEP IN FORMATION
(R) Color, APH/T
(R) Condition (R) Sp.Gr. @ 15.5/15.5`C,
(Rl Acidity (mg. KOH/g.)
(R) Moisture (H,0)
(R) Refractive Index @ 25 *C,
(R) Inorg, (Free) Chlorides
(R) Dielectric Strength @ 25*C.
(R) Resistivity
"
(500 VDC @ 100*C; 0, 1"
gap as ohms/cm. x 10')
(R) Viscosity @ 100 *F.
(R)* Pour Point
(R) Active EP-221 (%) (R) Distillation Range
(ASTM D-20, Corrected)
First Drop
35% by vol.
55% by vol.
65% by vol.
90% by vol.
(R) Corrosion Test (6 hrs. @ 210*C,
with bright aluminum foil)
Change in weight of Al%
AC Color
AC Condition
AC Acidity (rrg. KOH/g.)
AC Inorg. (Free) Chlorides
Dielectric Constant 1000 cycles, 100*C,
Fixed Chlorine
Fire Point
Arc-Formed Combustible gases Electrical Stability (Aged 96
hours @ 100*6. covered
jar, 15% air)
Decreace in Resistivity
R ESTR 1C TED 1NFQRMA THUft _.
7W) -Power Fa-,,t i
cycle*
and li0*C
150, max. Clear 1.563 - 1. 571 0.014, max. 30 ppm., max, 1.6068-1.6088 0.10 ppm., max. 35 K.V.,,min. 100, min.
41 - 45 SUS -44*C., max. 0.115 - 0.135
210*C., min. 240 - 256 *C, 290 - 330*C. 385 - 400*C, 395 - 415*C.
0.0 .M-'llA .'.00, max. Clear 0,014, max. 1,0 ppm., max. 3.8 - 4.2
60.0 - 61.0 None to boiling pt, 1.0%, max.
10%, max.
5.0%, max, ,
10, 084 10, 084 10, 114 10,087 10,620 in i?a 12,741 11,605 11,607
10, 086 10, 1)5 13,014
10,126
10, 084 10,084 10,087 12,741 11,608
10, 088 10, 12>3 10,711 10,121
11,608
(R / ticuune An aly m, 4 1.' /<. to A
(over)
\ ltd by taguttt Only
MONS 055589
37 11^mi
,
GENERAL INFORMATION
Dielectric Constant (1000 cycles @ 25*C.)
. 4,5 -4.9
11,608
MONS 055590
Monsanto OAOANIC CHCMICALI OIVIIIOH Anniston & Krummrich
FINISHED PRODUCT SPECIFICATION
ROOUCtlON
A. E. beisy
*ALfc*
M
W. E. Ault
EEMEEEL DC&CniPfl&M
"rJ"- .... ....
ftKOOuCT
Transformer PLANT
WGK
Inerteen PPO PRODUCT COOK 81092 __ 9JULAJZ_________
joCAT. ^ ^ I'.'.i;'
w,` ...... " SALES
3/30/70
1050-200-16-03/09
AEEEOVEIE
riic8A*eH
` " .............
-
,W.. R. Richard 9UAMTY CONTROL (tiitrt
R. M. Blowers
T.
EMEMiE EL rpEMUlE
Bell
Mixture - 60% Aroclor 1260: 40% Trichlorobenzene
Plus 0.20% Phenoxypropene Oxide
(Westinghouse Inerteen 7336-9)
MOU WT.
URKMSDBI , Of
AH*>LR POft *HAI.VI
ikiui'u'*Yr" 1
"
5/29/69
3 x 5 pt. Amber Bottles Higgerson/Stites .
CHAR ACT CRIST 1C
UMIT9
H3TU09
UNRESTRICTED INFORMATION
(R) Color
APHA 150, Max.
(R) Condition
Clear
(R) Sp.Gr. @ 15.5/15.5C
1.560 - 1.568
(R) Acidity (mg. KOH/g.)
0.014, Max.
(R) Moisture {H20)
30 ppm, Max.
(R) Refractive Index @ 25C.
1.6130-1.6154
(R) Inorganic (Free) Chlorides
0.10 ppm., Max.
(R) Dielectric Strength @ 25C.
35 KV, Min.
(R) Resistivity @ 100C
100 x 10 ohm/cm, Min.
500 VDC and 0.1" gap
,R) Viscosity @ 100F.
52-56 SUS
(R) Pour Point
-32C. , Max.
(R) Distillation Range:
. . (|ASTM D-20, Corrected)
First Drop
200C. , Min.
Below 270C., by wt.
40%, Max.
90% by wt.
395 - 415C.
(R) Corrosion Test, 6 hrs.
0 210C. with bright
Aluminum Foil
(R) Change in wt. of A1.
0.0%
AC Color
APHA 200, Max.
AC Condition
Clear
AC Acidity (mg. KOH/g.)
0.014, Max.
AC Inorganic (Free)
2.0 ppm, Max.
Chlorides
'
(R) Phenoxypropene Oxide
0.18 - 0.22%
(R) Fire Point
None to Boiling Point
(R) Dielectric Constant
3.7 - 4.0
1000 cycles, 100C.
Fixed Chlorine
59.1%, Min.
Arc Formed Combustible Gases
1.0%,Max.
Electrical Stability (ages 96 hr 1.
@ 100C, covered jar, 15% air)
Decrease in Resistivity
10%, Max.
10,084 10,084 10,114 10,087 10,620 10,125 12,741 11,605 11,607
10,086 10,115 10,117
10,126
10,084 10,084 10,087 12,741
11,865 10,123 10,608
10,088 10,711 10,121
RESTRICTED INFORMATION
(R) Power Factor @ 60 cycles and 100"C.
5.0%, Max.
11,609
(R) Routine Analysis, Ait others Analysed by request Only
(OVER)
HONS 055591
GENERAL INFORMATION
Dielectric Constant 1000 cycles, Z5*C,
Analysis of each 10 ml. fraction of a fractional distillation Chlorino/Hydrogen Ratio Arc Formed Combustible Gasoo
4.0-4,$
lt min. 1.5%, max.
HONS 055592
Monsanto
Anniston and Krummrich FINISHED PRODUCT SPECIFICATION
PROOUC IIDN
W, E. Ault
PRODUCT
oca. "
INERTEEN 7 Jl TRANSFORMER FLU.D
A r;
puant Annisto:WGK
DAT CL>VkI<! five
7/10/69
1`AOOUCT coo.. Ami.
81098 - WGK
SALES
lALCt CODE
1050-210-16-03/09
APPROV Alt R e s a .. 1
v.'. . r c-.ard
QUALITY CONTROL (Chlt ChtmltO
R. Mowers
till wo;
'
dNCRAl. DCICRIKTION
CHKMIC At PORMULA
Mixture
70% Aroclor 12 ; J 30% Trichlorofcenzene
Plus
0.30% Phenoxypi opene Oxide
MOL WT. UK KRIIDIIM fC .Or
4/18/66_______
AMPLK COM ANALYllI | 3x5 pt. Amber 1' o',ties
ItlUKOBV
Higgerson/Stites
C UAH AC T CHUT IC
LIMITS
MITHOO
UNRESTRICTED INFORMATION
_
'
(R) (R) (R) (R) (R) (R) (R)
(R) (R) (R)
-
(R) (R) (R) ,, (R) (R)
Color
Condition
Sp, Cr. @ 15.5/15, 5 *C,
Acidity (mg. KOH/g.)
Inorganic Chloride
Viscosity @ 100*F.
Resistivity 100`C.
ohm/cm
Dielectric Strength @ 25*C.
Refractive Index @ 25 *C,
Distillation
1st Drop
Below 270eC.
90% by wt.
Pour Point
Moisture (HjO)
Fire Point
Phenoxypropene Oxide
Corrosion Test 6 hrs. @ 210*C.
with bright A1 foil Change
in wt, of A1
'
AC Color
AC Condition
AC Acidity (mg KOH/g. )
AC Inorganic Chloride
50 APKA, max. Clea 1 1.518 - 1.528 0,011 max. 0.05 ppm., max. 58 - 62 SUS 500 >: .10 min.
35 KV, min. 1.6151 - 1.6173
200*C*.., min. 35%, v;ax. 379 ;94*C. - 3 0" C . , ma x. 30 p;;p.., max. None lu boiling pt. 0.18 * 0.22% 0. 0%
200 APHA, max. Clea:. 0.01s. max. 2.0 j on . , max.
10,084 10,084 10,114 10,087 12,741 10,086 11,607
11,605 10,125 10,117
10,115 10,620 10, 123 11,86 5 10, 126
10, 084 10, 084 10, 087 12,741
RESTRICTED INFORMATION
(R) Power Factor @ 60 cycles and 100C.
5.0%. max.
11,608
(f\) Rvulint Anol)tix, ill fth:a Ana'.yttd ly
0*'
Monsanto
ORGANIC CHEMICALS DIVISION
FINISHED PRODUCT SPECIFICATION
PRODUCTION
A. E. :.eisy
ales
W. E. Ault
QCNCRAL DESCRIPTION
PROOuCT
THSFMINOI, PR-0 PHiCMjtT CODE
TWtrOXKr,fr
..n/u/jQ.. APPROVAL* resc arc h
& A L.T C OO C
Salma
1
W. R. Richard
OJA LIT V CONTROL (Chief ChemfO
R. M. Blowers
CHEMICAL FORMULA
Formerly called MCS-295
MOL WT. UPERSEOE1 SPEC*. OF
11/4/68
CHARACTERISTIC
AMPLE FOR ANALYSIS
3 x 16 oz. W.M.Bottle
LIMITS
VIRES! /VCTED INFORMATION
80% Aroclor 1242 20# Tri-tetra Chlor-ober. ;or -
ISSUCO *Y
" ' ....... '
METHOD
;R) Appearance
Water white to pale yellow oily liquid
IClSn
!R) Vise. 10QF 'Rj Fire Point IR) Sp. Or. <P 25/15.5C
7.6-8.4 es None to boiling pt. 1.400-1.420
1CC-86 10123 10114
' ' P.) Pear Point (P.) Aridity, mg KOH/g (R) Water ( R) D; stillavion Range: ir.t drop
-15F, max. 0.05, max. 75 ppm., max.
Report
ICllt 1C 03 7 1C62C' lOu ;.v
30# over
Report
(R/ Routine Analysis, All others Analysed by request Cnly
HONS 055594
APPENDIX C PHYSICAL CONSTANTS DATA SHEETS
This section contains physical and chemical data of the raw materials and finished products.
Time 0 3 days 7 days
DEGRADATION OP TCB
INORGANIC CHLORIDES
Dark
Sunlight
.000004#
.000004#
.000004#
.0005#
.000004#
.001#
VAPOR PRESSURE OF PYRANOL 1481 (obsolete)
Temperature
112hc
? 40 30 20 10
0
Partial Pressure TCB
13.12 mm 0.76 0.34 0.23 0.111 0.057 0.027
Partial Pressure Aroclor 1254
0.039 mm 0.00051 0.00022 0.000086 0.000032 0.000011 0.0000036
Total Pressure Pyranol 1481
13.16 mm 0.76 0.34 0.23 0.114 0.057 0.02?
a.... 6o2oo PHYSICAL CONSTANTS DATA
'VtlilTAWCE
STRUCTURAL FORMULA
TRICHLOROBENZENE
(Mixture of 1, 2, 3 & 1, 2, 4T. C.B.)
TOWTMlEB'l'Y
*
DA'fi
Hooker Electrochemical Company 7-25-57
NAME
Formula
'
Molecular V/elchl
Aooeaiance
BoIHm Point ?t 70 mm Bollinjppint at mm
Cf.H,Cl, rffl3 Clear colorless
1
280*C
-____ SOURCE _fc_OATE Ref. 1 Ref. I
" Ref.-1
Ref. 2
Boilim Point el mm Crystalline Point
10`C. Max.
Ref. 3
Solution Point Soecific C-ravllve> 15. 5*C/15. 5'C.
Specific Gravity bounds per Gal. 9 15, 5 CC
Coefficient of Expansion Cubical
Reflective Index* 20 a ! Infra Red Spectrum (Relmnee)
Ultra Violet Spectrum (Rtftmct)
Viscosity 100* F
& cosily 210`F Sur r.ce TcnsiM @25* C _
_
SotiSUityJiLUstet. Sd ftilitv in water @ 25'C
5dubililv in
1.4bU- 1. 47 5
12. 2 .0008& 1. 57^
Ret. 3
Ref. 2 Ref. 2
1.100 Centistokes 0. 549 Centistokes . 38. 9 dynes/cm
. 0025 grams/100 grams
Ref. 2 Ref. 2 Ref. 2
Ref. 2
""
Flesli Tcint r f.Mahcdi Cleveland open cu j None
Fire Point (i
" " " None up to boiling pt.
I ftl Combust ion
He ol Formrtion tT mcl Slriilitv (cnl./kt/min.)
Leteril Hell ol Fusion________________________
uent Kurt ol Vn. $p; tilic tie-si @ 25*C
54 cal/gram 0. 20
Cji ical TciV.cereiure
CiUliEiElkXSM____________ Oilseciatiwi Ccn-tnl
'
Moisture content
Distillation range
V)
*
Decomposition temperature
Density correction factor
<Yeo_>i Isomer distribution
. 05`,'a. Max. 5*C. Max. incl 21fc*C 300 +C
. 00124 per 1*C
Mixture 1. 2. 3dl. 2. 4
<e O References (1) Dances Handbcr ok
References (2) Hooker Data SI eet
References (71 Hooker SDecifi cation Toxicity (Civt Rtftrtnct)
Ref. 2 Ref. 2
Ref. 2
Ref. 3 Ref. 3 Ref. 2 Ref. 2 Ref. 2
HONS 055596
. PHYSICAL
idrnnwgf"1.......................................
0
TKt-TETRA BLEND
Foimult Moltculti tVoisbt
NAME
pollinx Point ol ?C9 r.a
CON STAN'
6a 11
DATA
M iTJt'Ty *V ao^ITulT'^CI)' i
f(t)Tr"
1, 2, 3, 4-Tetra
26-29%
1,2.4, 5-Tetra
0- 3%
Penta
0- 5.5%
Trlchlorbenrene Remainder
Mixture ___
W W I .Inn IH
210-278C.
SOUHCf. 0 PATE Soectficatton
/GE material DS R R!R
Boilini Point it m CtystJlIjiir.! Point
Soecilic Cittvitv * 15. 5115. 5'1C. .
ocilie Giaxitv * Pounds p:i Gal.
kC
Coeftieienl ol Expansion
Reltocliyo lotuf 25UC. n i
Inlu Red SpKtrom (Mmmi
Ultis Violet Spectrum Wtlcrmcti
Viscosity*
.......... .
Viscosity * XurlfCG Trn*lon
...............
Solitllltv inV/flti
..............
Solrtllitvln
. ..
._
-15C. (Max. ) nr 1.510-1.520
12. (i......
1. 577J-.1.5780
. ...
& j
i
Lj
Fluli Point F (ikthd/ Fits Point C
Hoot ol CO'.Vitlltn
...................
Hot! ol Fwir.otiin
..
Tl'Oimrl Jli'illltv (eI.A/'<nin.)...................
LflBiUisSPliisita______ ____ L'tnnl Hr! ol Vro.
Specific Ko-t
-
Ciiiictl Tt.-oorrtuie
CutirlP.fv.a_________________________
Dis ".I: lion
None to B. P.
-----
,
is e u
at
O ------- ---------------------------------
'
* >
HONS 055597
---- . -------
Toxicity rCiK Rrirrriui) Sax. Handbook f Dangerous Materials Rc inhold. N.V. llllii uw.92&3oC. \l , C. A. S..D. Sneet a4. 1'JaJ.
NOTE: 7 He if dolo thouitl Ml A* ntajtd on Iiid* of Mo fit onto CHoutcol Cotnpaoy. V tt Additional ikeeti if ntteitary.
ZJ'H tl>
36100 PHYSICAL COi'-IST/ trrro D/-. i/
i .............. --
"irn'wevu, AL. ro.i.vyuA
___ i__ (Phenoxvpropeneoxdde lA__
A. M. Ellenbur?
NAME
Foirti#
I'.)!!-iiI'.i V.'-iri.l *"*f *V\
Pill' -' Pol:> r' 7.'1 r: i
"-----------------------
DATR
7/1.57
157 . 10 245t.
'.............
/~\-OCH3CH .C H2
Nc/
. . 5Pi!f!SJ!JL.vr.'
_
Ref. 1
Ref. 1
..............
PMUm Pa'i'.i rt rn
B;ilii:' Peat ft li.n
CivAsIHilPt Pciitt
r*
Mi'in robt
.
t' olilcGnvilvo 20/4wC
to cl.'ic GrvHvo I'c --oia f v Gsl. t o.o C
Co .Ifei! cl Cr--,:!c.o fli rtiiivo Irlos*
"6
Infra Red $r:rtrMf/it//*r.;
Ultra Vloltl InTM tnc'rnct)
VlKMltV*
20cC
VlsMsIlv o
30C
Srrf'^T`^!M
J>nUr
fol' illlly IV. 20C
Srt'tiliiriafMi'"* or:
tnlibliitv liiAcetone
. .
3.5C
1.1092
5
0. 0008.1 cp./r.e/C:
1.5314
'
1Ref. __________________
Ref. 1______________
.
_Ril__ 1______
_RReefJ.u_1l
-
__
7.05 cs .44.} 88 ca___ . 0 24fthv wl_______________ J2 DC?. '
Ref. 1
.
Ref. Ref
11____________. ______ U____ '
Ref. 1
.
Ref 1
Ref. 1_______________ _
FI: A fF <r ! Ttt * Ons'i Cun . .
Eii tvv l'c
'
'
H' N'O-"'-
1 ol Ft:." '.i:i I!' lirol S'.':l 11.7(c:l./!;v'rr.in.1
....
I" 1 ""I rl V:\
...
$ n-.i:--'
\c-; :"-|T -'-.r=.;v:>
c<' r>:> *
,
t! 1 r-
. ..........
175 F .
--
..._
Ref. 1
^^ilX^U-TachiUciOJiO 2ln.- Rn.fUo.ft
l}
i: L>
P MONS 055598 O ,
To,' :?y fV\iLT) 50 IMtc?) _L_?_rx' nvr <*_
Mainly skin Irrlfv.t
.
r,Kt. i
Ref.' 1
HO ftfi Tht?i den tSoidd ry>! fc<* rtlca'td ovltlio of !'onsar!o Ch**z4t.c-l Cor-pony. Vs* tuldtthsnal i,S ms If
____
t6a>inim---A. M. El f b'/ r g
Foimula_____________ __________
MoltcuHi Weifcht________
tauim_________ Boiling Paint el 760 mm Rar.ee___
emd-jL 3_.jmi____ 1!____ ___
6fliiins_EcJrXJt__ Jam. Soiling Point at mm
CmUlliiing Poinl
_____
Meltm; Point_____ _
SaliSisafsial_____________
*SoccilicGiavily 5/25 C. ISpccilit Giavily a 28/ 5.5 C.
Pounds pcT fesl. tg "75TC
n l t, CoeHicienloi Expansion 15-65 C.
Reliactivo Indot 5 C. n
lulu Ulllt
RVeiodleStptScplieucniliuWm (tI/lai/twrewn;ct/
aViscosity __ 10_ZL______
Viscosity .iOO-F,.
____
Surttct Ttnsioii Dy-s/cm jg.zO/C..
Solubililv In V/atoc
Solubility In SAAicc-vol l9 C.
Solubility in Pyrdtr.f Ig ?QCC,
Cjj> Hi C! 1 Z5~ ave. _pIqx1slss . Moh.^E-Q-. )25_-160 C. -1.5.5 qSLX.
Nor - c rvsial ti oi .- e
1. 580 1.561 - 1, 19> 11.50 .Q..0.PQ6fc_Xix:/ ' C.. J..U45.-- U5&.5.
J.1-..15 SU.S . -Z^Si_SiI3_ JJL.L Ir-sy! .blp n. ) e./IOQ cc
(' .5--\ v. .y _________ Cl_________
SOURCE & DATE
M,r.sa.Ur_&u.lL -QP,l, , Mi*
S^Uu.aly-:- .^4- i5_ .MLJL--OELul.3
C(UU
FJasb Point ^V-MeiAeiL- < . o. c.
ritoToinl *C~
c.o.c ,
Heal oi Combustion
Hoot ol Fourction
Thetmnl Sl&llily (ttlTIO/'mln.)
UStnlJisjUf.fJiusn
Ltlt"L!kLsl.V.a_?-aJiiil3_i_________
CiHittl Ttapwautc___________ ___
CutaLQm'Ji-
GiSMMlltC.CB.Et.i5l.-_______ _
Sm c I: c Hen'
100 1 C
Pi' . r
________ ___
-T---'-O---i-i-m-----C---o-----d--cc-m-c-'i;-\-i-'-v--,---c--a--l-/
D e cc1 r. r Cc-s'ar 100 C.
60 cv.
I so C. N'cne
6i____ _Lli?1_
JL_LiflL 14 C c.r loufr
'aTa"~"(q~~2~c. -9
Tonicity Km iitlntncc) *____
V'-- Cnn'^c' Med, eg_Df'jy
|_A_u!.aAexL.... ______
X^-bp-
JJ- A-
_____
so'* O, y
/x________ -.f,?.
____ _____ y.
J6L_E._QP.-XjX
OOss .<<00 5
I
NOTE; 1 hr i ( d<ito ihouId net bt tt(tot ed t>uf ji<f r of Monso'wo CAemicoZ Cof'/'ofiy l st
'her:* >( n
13 PHYSICAL CONSTANTS DATA
"iWmter ............ -.................................... ABOCLOB 1264
structural formula
'zrmwn.'zrm------------------------------------ -
A.M.EUerbjrE
NAME '
Formula
Moleculai Wei phi
Aooeaiance
fisJliaiMitJLMjnai___ &arj?je______ ____
Bo linapolrt al 3 ir.m
"
fin lin( Point ft mm
line Point at mm
Cn stations Point Mnltinj Pfiinl
Solution Polnl
'n
Soccllic Giavitv 0 25/2!: "C.
Specific Gisvlly 6.6/15. 5UC. Pounds per Gal. <# 26 C
Coefficient ol Expansion 25 65UC.
Retractive Index
5'Pr" 5
Inlia Red Spoctium CRc/en;
Ultra Violet Spectrum (Reftrcnctj
Viscosity 9
210 F
Viscosity rr
Sul rce Tension Sol ublllly InV/alei
........... .... Dvr.es/cm ........... _......... .
Solubility in. 3A Alcohol @21"C______
Mljollity in Pvrf @ 31UC.
oatt------------4-2?-4"
Cl? HnCle. 32$ 'AVF.^:
Pule vp.l.nw 366-40. C iRn?.ior
Ifso-j oil
(,.kC
. 50URCE..6 DATE
Mogsar.:o BuItll. OP I1` <' 1 p = II
Non-crvslal.ietr-fi
1-638.... 1 4fin.-1.500 12.82 0, 00066 eg,'cc/"C._ 1.6370 -1. 6390
II
II
HliR.IJP-116 Sf-eclflcaMo- 2/14 /*6
..
44-48 SUS
MB OP- 115
60.3 2SC. 42.0100a -n
Insoluble__________________
10 e. /10P cc. 114 e. /100 cc
II II
If II
Flash Polnl tiMr.M) c.o. c.
E!l PointC
c.o. c.
tiM 1 of Cofr.busllrn
Her ol Formation
ms |mrl StibllilvIcal.Ae/min.)
U nut Meal of Fusion
nnf Hp*I ft!
a l / rrm
...
Setciiic iioat
r:- c.
Cri leal Tccroeralure
foil leal Piesswc
.
DUSDclatUn Constant
~
Sr rcl'ic lire fit 3QQ c.____________
Poe Pot- . !' crm.i2 Co-.dUc-ivl-v. Celt
cm/C.'Sec.
N sr. e No-: p
50 0. 26!
0. 33?
M*c. ,,
22 n Ip 2flr
D.plf :.r;c Co* .*?.***, lOO^C, SO .
4. IK 4. 3.:
II II
Calculat'd _MB QP-ll-............................
II
To be published
MB-OP-11r
HONS 055600
__ -
I Other Constants |
Toxicily (Glue Rt(erence)
Cor-ar M'-d:gil Dff..
m p or-ir
NOTE; These doto should not be teleased outside of ^lonsoata Chemical Company. Use additional sheet! if nt re i scry.
r II I
I wri
'Tudni'Bcr
--
AROCLOR 1260
'
S-> WI \J w v / * < J I W u. / i K
' STRycl JR A L rC-MMUc A
' '*
< tmmtrp rv----------------------------------
oatT
______ A. M. Ellenbore4/25/5"
C1 6.25
NAME
SOURCE ft DATE
Formula Molecular WoifihJ
'
u| 1 "-i
1.B, 26__________
361 (Ave. 1
Aoooaiince
._
Bel tins Point at 760 mm Ranee Bo lint Point at 3 mm ..." ...
.
Lt. Yell, soft sticky resin
3B5-420V. 19B-245UP
Monsanto BuIIll. QP-115'19 II
finilln? Point ft mm
poilin! Point at mm Crvsltlllzlni Point
_ Non-Crystallizing________
II
Solution Point Soecitit Gravitye
. 25/25/''C.
1.620
Specific Gravitv
an Mb Bur
1.555-1.566 ____ ,_________ Specification 2/14/55
Pounds poi Osl. v 25 C " 13.50
_________ MB OP-115____
__
Co fficicnt of Expansion po-tnnr Re icctive index o OB^r n J
Infra Red Spectrum (Reference)
0. 00067 cc/ccrc. 1. 6455-1.6465___________ _Sfie-cilicAtiQU-Z/. Ll/Jif? _ _
Ultu Violet SpectrumiReicmcc)
Viscosity o
..... . 210UF.
72-78 SUS
MB OP-115
. _.
yis cosltv Sun ace Tension
.
Solubility in Wtler _
____i Insoluble_______ __________
Solubilitv in ( Sol ability in _ _
._
Finsh Point ^F ftk-Ml c. o. c.
Ql Point C Hjf | p| Cpn.lsusllon
o. c.
He. t ol Formction
Thi imil SlrWIIIy IciUke/mlnJ
.
Lelent Heat ol Fusion
Uent Heel ol Vrt>.
$3!clfic Heat Cri leal Te-raotarure
ral/crm @ 25C.
.....
Ctii jql Pressure
Qissoeletion CcictfM
_......... _ ....
None None
48 0. 228
0, 303
Pour Point
V)
n O(AS
DinWfrir. Constant. 100 C 60 cy.
sts> o
25.-3 4UC\ 3.6-3.8
~ .
II ff
Calculated1 MR OP.-1 15 _
II ' II .. ff
HONS 055601
_ '*'
TPAiclly (Give Reference)
Coniact Medical Deot.
MB OP-115
HOTEl These data should net be released cutside ef Monscr,io Chemical Company. Use odditir.r.rd sheets if I
a.. PHYSICAL CONSTANTS DATA
nmmr
STRUCTURAL TOLUULA
INERTEKN P.P.O. tomnrwrsr"
60% 407o 0 ,27.
Mixture
Aroclor 1260 Trichlorobenzenc Phenoxypropene Oxide
NAME Fotmula Itolociiliii V.'ei jhl Anftf.fMM
jtollln I'rlri <d 7E0 r..n EtoHlripo'r: ft mm
Ranne
Yellow tinted mobile oil 200 - 415 'C.
souncc 6 OATE
Ref. 1________________ . Ref. 1___________________
Bolllr? Politl ;t n Crvstelllilw. Point
______________________ __
Solution Point $oecltlc Giwilv r> 1.5.5/1 5.5 C .
Snodlic Gravity Pounds pit Gel. <e 15.5 C
Coollicier.lcl Exn?.ion (20 - 100'C.t Refractive Ir.lsx * 25*0. n2 )/!/& fiei) Ss'AlflT (Reference)
Ultra Violet $t:st(l'.:a (Reference)
Viscosity 100CF.
Viscosity ? 20 'C.
1.560-1.568
'
13.05
0.0007 cc/cc/*C. 1.6137 - 1.615.7
52 - 56 SUS 15 cs.
Ref. 1 ._
...
Ref. 1__________ Ref. 1 Ref. 1 .
Ref. 1 Ref. 2
. ....
Snlibiiitv InVeter ~Splr5mt- In Solubility ir.
. . ..............
A i j 1 i
Fit :h Pci.;: F :i CQC
_
H'j*t e! C-*.iYr>!in Mart t>l FtrairtiM
Ih ir.i Sl-'iilliV (c.?./.:v'r.'.iii.> \J' v.u: '\eA Fiv'i
U`
Sr-. elffo
M5*C. -80#C^i ..
C'itic 1T: -uCli
.
__
Gti j L~'"
. ..
Ci;
. '
Pour Point
0. 26 -32'C. or lov/er
Dielectric Constant. 100C. 60 cv.
Thermal Coa/rjsctivitv. cal/ u cm/eec/ "C. O
3.7 - 4.0 20 x 10-5 at 50*C.
[_R>Jj&UcRC'&JJLL ? sifj cj'.t.io.ae
jLS_
__*&/&uutCA.i&) - Aiarj53)UP_Chf.-misjLVai.td*
Tntirilv /Ci'iv Ptlerc-tcc)
Contact Medical Dent.
Ref, 1
Ref, ?.
Ref. 1 Ref. 1 Ref. 2
HONS 056602 I
PHYSICAL CONSTANTS DA I A
''RWiv.cr--------------------' '
"
tuctw*u roRMyi*
PYRANOL MB 1
n)
xvupwvny------------------------------------ -
Mixture 757o Aroclor 1254 25% Trlchloroberuene
NAME
FomuLa.... ............ Molecular v/eighl___ tsimtmt________
fell'S EaiJiLJl.__ mm________ BmlintEoinlja___ mm-----------Boiline Paint al mm________ Crvsla'liaine Point MEltLO.PjtiQj______
SOUftCf. ft DATE
Specs. Jan 28, 1955
Specific Gravity v Pounds per del, m IS. jffiT
CocHictenl of Expansion (20- lOO^C) Retractive lnde n 25C "8 Inlra Red Speclium (Reiercnct) lljlra Violet Speclrurn (Hthmct)
Viscosity o_______ 10W__
!tiKSS!DL<! SlUlKS.lMSlill___ MSilltoiLKilB.SaiitUUlfvJiL____ VJobiJily.in,_____
-1JL.7.5-7Qr.a2_sns.
Flesh _________ fnc Pojnl.!C_____ XLjO-C*..
I.'in) iLCPIitSUFS______________ Meet ol Fwmrtion Theimsl St'tiilltv (col.Ao/min.)___
UtoMiteAsLtiaisi________
___ ___UMJjiUUte,.....________
l.rilicel fc-.TOC'.me__,________ CuiifsUrrjY.Ut).u:Kii|iea.Ccrr:tiil._ PO1, r lie__
--ijoae-lc-hailing-- ..-15ZCjic_ teller.
I Dielectric Constant, IPQC, 60 cy, 4.1 . 4.6
Tomcrty (Cnv Rtjrl'ncc)
Contact Medical Dept,
HONS 055603
NOTE: Tbfti data thould no l b* rtlecs td on it id* of Mtn.ianlo Chtmieot Company. Use additional th.ttIs if mat i cry
PHYSICAL COWSTAiTi'S DATA
iTftuc'fuaM. rortiAut* " * ..............
PYRANOL 1488 COMHM.CU UY
DATs
Mixture 607o Aroclor 1260 40% Trichlorobenaenc
A,. Ml..EUenb\irf>
NAM*
....
7-9-57
unt<MrMrurttra-t joor.'i^i--u.
source & date
2E>_ Iible?ul;'.r V;>iit
l: .......
lllr'FrJiifU/lniKarrs
ft n
.........
200 - 415*0.
.. . hoi. i ... ... Ref. 1
P/sIIIm PM;| (! m . ...................... pollir" Pv'ii.t it rm Pfyrf'.lllii*' Polr.t
" -
Pc'rl
ftMilir.O'- :lvo 15.5/15.5*0____
y- .tills Crvitvo
'
h j.T!'-; ri C:i. o i 5 5 CC
C: :illsl:.! tl Era v!n <80 - 100 *C.l Ro*rr?tJv> 1rJ?x <? ?r*C. nJ
IMlB ll'.l h:c`.ir:l mA'-'-.t')
Uilttf Vip!'-i t:
CRcfcrrr.f t)
VtSCWitYO J.flO *j.
yis;pp!tv p 20 *c.
_
5i-dr v. T
.
"illi;* li3..1aL. M VlllY i.l
W V.litv in
.
1.560 - 1.568
13.05 0. 0007 cc/cc/*C. 1.6137 - 1.6147
52-56 SUS 15 cs.
Kef., i .::
iuTT l Ref. 1 . Ref. 1....
.
Ref. 1 Raf. 2
D; *r-'-;TFr->!> one Fi; i ','r.
i:- ' ' r. ; .1
H:;!.0! Kr-r";i,'i . . .
TF rrrl $ ,-!li;Y(r!.A'7riii.l
l: r-' < i i:' 5;i
l- 1 r < t.i V- v
t. ' (?.s *c. - 80*c.l
ClL 1: 1V : n
.
t: ti Si' i`r V `
Nojvj to boiling
Ref. 1
0.26
Ref. 2
.
Po-\r Sc'hit --
1 -32*C. or lower 1
Ref. 1
r>SSr1:Sr
100*C.
VK
60 cv. ThftiTn-'l CouAiC.'ivitY. cal/
OS cro/r.ec/ *0.
3.7 - 4.0 20 x 10-5 P.t 50*C. .
Ref. 1 Ref. 2................
S XlrffTOnro (1)
------R--e---/-o--r-o--r.c ^ {?.)
rnjcJ.'icV'to*-** J 6-6-55 Ch*1 i'.ll Coll i
HTUnr.it)
1 Co*\t7.ct MocHc i
HONS 055604
NO Y tii: Thttt
i/t&utj t<ol be rclca-rd e tit of 'Jonte-.s.to Clicylal Co.'.tocAv. Vte oJJiiJtfuJ shod* if r*r: .*v.
DEPT. 259 - STANDARD MANUFACTURING PROCESS P.vranols, Inerteens. and FR-0
APPENDIX D
UTILITIES
The utility calculations are based on 1970 YTD usages. Monthly
YTD production averages 1.2M-lbs.
The breakdown of utility usage by individual equipment is only an estimate. The estimates are based on the total monthly usage of each utility as taken from the cost report, and the relative period of time that each is operated.
ITEM NO.
153 154 160
163 164 165
17^
44ov, 3 phase, 60 cycle
EQUIPMENT MOTOR
MOTOR HP
PEAK LOAD KW
MONTHLY USAGE KWH
TCB Pump #3 Mix Tank #3 Mix Tank Pump TTCB Pump //2 Mix Tank #2 Mix Tank Pump TCB/TTCB Tank Car Pump
3.0 7.5 10.0
7.5 7.5 10.0
5-0
2.6 6.6 8.8
6.6 6.6 8.8
4.4
250 4000 3000
250 4000 3000
500
TOTALS
50.5
`44.4
15000
In addition, 110V power is used for lighting and small miscellaneous equipment.
2. NITROGEN (bulk) - Because this cost is negligible, all costs are charged to Aroclors.
ITEM NO.
USING EQUIPMENT
NORMAL USE SC EH
PEAK USE SC EH
MONTHLY USAGE,SCF
154
#3 Mix Tank
4
164
#2 Mix Tank
4
TOTALS
8
5 2000
5 2000 10 4000
STEAM (80 psig @325P)
ITEM USING
NORMAL USE
NO. EQUIPMENT M BTU1s./HR..
154 #3 Mix Tk
500
164 #2 Mix Tk
500
--- Drum Heater
50
and MloC.
____
TOTALS
1050
PEAK USE M BTU's/HR.
750 750 100 --
1600
MONTHLY USAGES BTU's
300 300
40
____
640
MONS
055605
15.
DEPARTMENT 259 - Standard Manufacturing Process P.Vdraul A-200 and 280
APPENDIX E
PERSONNEL
Departments 246 and 259 are operated with one work force. For this reason the description of operating classifications and assignments given below are for both Dept. 246 and 259.
OPERATING CLASSIFICATIONS
JOB '
.
NUMBER OF HEN
(21 shifts/week)
Premium Operator
A
Still Operator
Second Operator
4
Standard Operator
2
#1 Swlngman #2. Swlngman
1 1
Repairman
1
Porter '
1/2
TOTAL
17 1/2 men
There is one premium operator, one still operator, and one second operator every shift. The Standard Operators work the day and middle shifts 5 days/week. #1 Swlngman works as the hourly foremen on Saturday and Sunday, as Premium Operator on Monday, and Repairman on Thursday and Friday. #2 Swlngman works 3 shifts as a Standard Operator, one shift as a Still Operator, and one shift as a Second Operator. The repairman works Saturday-Wednesday on the day shift. The porter works 1/2 time in 246/259 and 1/2 time in 243/244/248. A typical work schedule is Included in this Appendix.
OPERATING ASSIGNMENTS
Only the major equipment and operating responsibilities are indicated in this listing. All are responsible for safety and housekeeping.
PREMIUM OPERATOR; Operates 4 continuous chlorlnators and 5 batch chiorinaTors. The premium operator has been required to run only 4 of the 5 batch chlorlnators if the continuous chlorlnators are running.
STILL OPERATOR: Is responsible for 4 take-over stills, runs~only~3 or less at a time.
SECOND OPERATOR: Operates two blend tanks, two finished
product tanks, 9 storage tanks, three mix tanks, makes all. Pyranol and Pydraul mixes, loads trailers and tank car3, and belongs to the Fire Brigade.
MONS 055606
DEPARTMENT 269 - Standard Manufacturing Process P.vdraul A-gQO and g8o
APPENDIX E (cont'd.)
16.
STANDARD OPERATOR: Fills, stencils and labels 5-pint bottles, and 5, 30, and 55 gallon drums.
REPAIRMAN: Unloads cars and trailers of biphenyl, TCB, TTCB, and finished product. Does minor repair work in department.
HOURLY FOREMAN: Is department foreman on weekends, responsible for maintenance arrangements, night sheets, and line-up of work.
PORTER: Cleans offices, control room, repair room, rest room,
and smoking shelter.
*
HONS 05560?
HONS 055608
Sex* / 2 3 H S t 7 ?
/ fl tt 13 W /5 ft n
Sob
RepmitMiit PRen. ofex
2'-" open. Sro cPER. -
o/a?; ' ^2 Swtttz f- '-:f
DEP~ 24<o SCHEDULE'S
r S ft T VT f S 1 Mr \/ T r 1 ;nrv/TF 5 S MTVT f $ s nr wr c- s J M T WT e S
taxrJiGn*# / ( / 1 i i 1 1 1 1
iREfotfi/nAti 2 2Z2 l 1 Z 2 22 2 t 1 2 2222ii2 222 2 t 1 2 7.7.7.2 \ i ?. 2222*12
PReniUrrj OPspxroR
0 ssos s t 6 6663333 31 w 11414 S'S-SS S 6 (0 6663333
n SSSSSLL 6 6i 3333 3 / 0/1414141;. SSSiSCC 6463333 3 ! `4 4 4 <4 4
L 6663333 3 i ! `f *6 * * SSSSSb6 6663335 s t 14 ^ h tr asSSSib
Still OPeRPTiR
0 /6/6/1/3 *3/3/3 MKWFf FlJfftfl
/?/6 /6/F fc/6 /*/S/313/S Wi4 W W /s' wr KTlClCn !lo ibll
H w m * li 1S1S tr/^irn
It 16 17 >3 1313/* Win rti<: wiff/tf iClf im HsH, !U It/l I$I3131313
L etsan haa /'-/Mi /3 /3 13/t /* M lt H /S'IJ> (differ 17 /6/6/6 It, n 1312 1313 13 M |H l*# m IS* is
SECofJCt D 7 tTRftl 1 ? <! to to /o // 1? 7 7 7 7 7 f f f f f ? t 11 1 10/0 /* to to n 7 7 7 7
OPERffnR N 7 13 Home * 'W7 7 7 7 7 urrrn 1 * 1 *010 10 10 10 17 7 7 7 7 7}rrrfi
L toiom 1 n 7
ri * 1
1010 17 7 7 7 7 7 r r r r sr 1 1 1 1 7 / me
ST*HOAttt> t> n% m tt h n iljgtt /2tt tt/7 *7% M 11 H /7 17 j% Ml 12 1217 /? /I H n n%l2ll izu 17
ope#rt* n IZ ll 12 12 H
//If It II II
IZ a 12 12 12
II U t it ll
ll 12 ll 1212
tt a tt it ii
>T>e
SMTwT.es 5 r.rwr f s frwTPS s n T a T f s sMTvrps S M TT PS
PERIL
i a 3 l 6 7 ir i i*r3ttr/t/7 /f 1120 V 22 731414 2627 2/2139
MAY
/*#/ IZ/3H ifA mill 2J 2A23
a > it
/ 2 3 V -T 6 7 f 1
JUNE
Jrvty
) 3.3 4S0 7 f 7 to u rzi3 wif/Lnitntfi *1121327 2SSSZI ji^rs*
1 231 5 6 7 r 1 /* n tz 13 h ifn n if OlMZilXiZjM if'1-'* 27 27 212# 2/
fiuzvir
M/I 121* ///* unit nun21 13 242SZL 212*23 33/
i
SsFTerncn-P, mi Kan ir n J&2/22 2J2 2T2J 27 2/213*
1 2.3 4/ L 7 9 1 /o //
Ocrosea
3i
# 23 4 e 6 7 t 1 10 // tt/J/y/T/6/7 ir n ia 2/2213 2*
tfovj/>i
i \3 ys-67 11 10 1112.1114 IS lt/7 it112021 utsi-l/sx-nit 2330
PEX.EP) BSR
13JJ TAV
FEseuniZy AAttC//
APRIL
/a. arttf n,n rtn Jazi iii37Jf2f2Z 2? 2171'! 31
I7/J/1 uiueLani>s V
1 Z j v r 4 7 r i / // /J Hits'tL
1 2 3 V 5" 6 7 11 to tt 12.13 W/r/6 n ifto to V U232J/2S2L23
r.t
/ 2 ;f i l 7 d S / W *X /? // /i*/6 17 It /12A it 2Zn;:!2?12Ti PSTHoU
1 ---------*--------*
1 7. 3 4 C tm 7 1^11
#1 /Ai; 17/iV/V i: . Uil/21*I2V jriLuxtiM*
DEPT. 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0
APPENDIX F
PACKAGING AND SHIPPING
Aroclors, and Pyranols are filled about 30$ In drums and 70$ in tank cars or tank trucks. About 2/3 of the Pydrauls are drummed and 1/3 sold as bulk.
A substantial amount (about 30$) of the Aroclor produced is used to make Pyranols and Pydrauls. This $ will drop to 20-25$ as the Aroclor-containing Pydraul formulations are replaced.
Sales are largely directly to the customer. The remainder is in bulk shipments to the J. F. Queeny Plant or to Therminol users within W.G.K.
All electrical grade tank truck shipments are made in the customers' trucks which are stainless steel. Non-electrical Aroclors are shipped in leased trucks and may be iron although other materials of construction are suitable. Pydraul is shipped in steel tank trucks. At present no Pyranols or Inerteens are shipped by truck.
Electrical grade Aroclor and Pyranols are shipped in solid aluminum tank cars or in lined tank cars either *1,000 or 8,000 gallons in capacity. The lining is either tin, zinc or aluminum spray because Iron contamination is detrimental to the electrical properties. Electrical grade cars are either owned by Monsanto or on a long term lease. Non-Electrical grade Aroclor is shipped In steel cars.
All bulk shipments of material are sampled from the final container. That is all tank cars and tank trucks are sample d and analyzed after loading. Drums are not analyzed; the storage tank analysis
is used unless a drum sample analysis is requested.
Tank cars and tank trucks are Inspected by supervision to be sure they are free of dirt and water or other foreign material before loading. Heels are drained before loading when their quality ic questionable or when it is incompatible with the material to be loaded. Car washing when necessary is done by the repair track. Tank cars are sealed with a numbered aluminum seal by repair track personnel.
Epoxy phenolic double lined, drums are used for Aroclors, Thcrmlnols, and Pyranols and plain steel drums are used for Pydrauls.
The drummed product is sold to the W.G.K. warehouse and from there sold to customers. Minimums and maximums for number of drums in the warehouse is set by Production and Production Planning personnel. They are reviewed at least once a year. Warehouse stock reports are reviewed by production at least weekly to determine heeds. On the following page is a listing of all Dept. 2*l6/259 drummed produ
HONS 055609
Product
Grade
'' gg~x 600 E
... g'a.
x 600 HE..... 2^0
Xg42..H.-5.5.IS. .
___ g'u
lgHg x 55 NE
.2^0
Aroclor
Dept. 2kb - Drum Stocks . Minimum Maximum On Hand
,12^8 x.600 E 12^ X 600 NE ... .
12M_x_S5_E_ 124$. x 65 NE
...-261 260
260
3.g5^ .x. 600 E
_2gJL_
1250.0_E_.
___ gp___
125^.x. 60 NE .... 280
1P(>0 x 606 E
1260. x . 600 NE J.260 x 60 E lg60 x 60 NE
2Q1 200
22___ 290..
1262 x 600 NE lg6g x 60 NE
500 ... 500
ii'g^i) VlOS Xvlend 2gS
' ermlnol FR I x 600 I x 55
II x 600 II * 55 III x 600 IH-Jl.iL
2U5 2AS 165 265
28.5 ^5
Pyranol & Pydraul
1260" PKrjrsT^ T206 pptnrjoO T?o(TFlrc5~x_65~ ys-stnw -a bin --FP'iTx J65~
" PYtTxToO--
255 255 205 210 210 Flo
1
Date. Needed
Pilled
--------------__
-- Cate.
TfiJsirii-nrsrb" -- 30-0
TiTjiilT x""jo(3~
300"
AlSliJjO x oy
30D~
STiHjr'r^tr-
T2V2TF0"x~S0O ' " "2T5
Tg^rpcrr^go '" 215
'''irrTFcnr 53 ~ 2Tb
Fyc!raul~T2T)"0' x ik3 2oo Ty draul-AYC'J' x'"5.- ~~ 250 Pydraul ?<T0 >: o?l ^60 Vydraul '230 >: 60" 200
1
|
1
HONS 055610
DEPARTMENT 259 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0 APPENDIX 0 MATERIAL BALANCE A detailed material balance on Dept. 259 was not made because losses In the process are negligible In terms of yield. Minor losses are discussed In Appendix H. TCB and TTCB yields on Individual batches can be less than standard or over theory. This Is due to the fact that blends are made and adjusted to a specific gravity range rather than by percent composition. (See "Yield11 section of Comments on Process). The attapulgus earth and nitrogen is used to upgrade the electrical properties. They do not become a part of the finished goods.
MCNS 055611
DEPT. 259 - STANDARD MANUFACTURING PROCESS 'Pyranol'a. Inerteens, and FR-0
APPfeHDlX H PFODUCT LOSSES
Estimated product losses in terms of source are shown below:
Loss (Est.)
Source
Typical 12,000
% of Total #Ar. Based on
Gal. Batch (gals.) Produced
15TT Pvranols
1.Spills
2.Samples and rinses
10 gal. 6
0.0&2% 0.050
12,500 7,500
3.Retained in empty drums
2
ll.Pump leakage 2
5. FI Iter waste 2
0.017 0.017 0.017
2,500 2,500 2,500
6.Fumes TOTALS
2 2k gallons
0.017 0.200%
2,500 30,000
DISCHARGE TO ATMOSPHERE
. Based on the above estimate, Pyranol production losses to the atmos phere amount to about 2500 lbs. of material per year (source #6). This is TCB, TTCB, and Aroclors. This estimate is based on a minimal amount of mix tank vent sampling data.
DISCHARGE TO SEWERS
Materials from sources #2 and
are currently being held in drums for
incineration. Product from sources #3 and #5 go to the landfill.
Spills (source #1) soak into the soil and chat in the department are?.
It is unknown whether or not any of the material gets to the sewer via
rainwater run-off. Within six months a project will be completed which
will collect any spills in a settling basin.
HONS 055612
DECT. 59 - STANDARD MANUFACTURING PROCESS Pyranols, Inerteens, and FR-0 APPENDIX I PROCESS CONTROL
Three forms are Included in this section: 1. A table of process control variables. 2. A Pyranol batch sheet. 3. A daily transfer sheet (for all transfers made by Second Operator).
KEY VARIABLES 1. TCB and TTCB Quality - The certificate of analysis should Be noted before the material is used. If poor quality chlorobenzenes are used, poor blends result. In some cases the low quality blend can be upgraded, but in others it cannot. 2. Mix Tank Temperature - In most cases the temperature should be 90-100C.' At lower temperatures high moisture content is possible. At high temperatures (130C. and above) loss of the chlorobenzene may be great enough to throw the specif! gravity or refractive index out of specification. 3. Use of Batch Sheets - In a batch blending operation the only operating data available is that which the operator records. Therefore these records must be maintained properly, if r.he batch is in specification on the first analysis, the transfer data will bo little used. When problems occur the raw data is indispensible.
055612
HONS
Pyranola 12^0 PPO, 70/30. A13B3B, end 5*201 CX
tm l*
ItttScta kftrtr,
fcbrtafels Or tas&Ltr, TSalA,
1. Raw mttrUl
Analysis (a) A12r*c2e.lo1r25*1,
and 1260
analysis.
specification
At leasq
gravity Is checked
before
each us<
Bach finish)
lot of Arocloii
(See finished goods speciflleatlors sheet*).
Directly affects Make adjust*
all rinlshed
mente when
goods analyses. necessary.
The reliability of Aroclor quality la very high. There fore a specific gravity and refractive index check Is the only required analysis
prior to its use In a Pyranol (Inerteen) blend.
shift A(0)
S.O. ant Each speclflcatl<f> Index aj
1011* 10125
Directly affects Accept or
all finished
reject ship*
TCB and 7TCB are supplied by Booker. A Certificate of
checked
goods analyses. sent.
Analysis Is received with each
on each
shipment.
shipment!
Raw Material Addition (a)
Contents
tank befoi charging
raw eater lals.
Proportion^ of aajor coaportents!
Por differlent productsL the elx tank] should be [empty beforef [charging; identical products can! be built 01 a heel.
The ratios should be near those specified lnj the Standard! [Manufacturing 'process Ibut not [necessarily [exactly.
Level gauges, or meter.1
Bach Pyranol has different ehseical and
physical proper ties.
Drw out elx tank before eaking new
batch.
poraally a new bIx Is not Bade on an existing heel. This Is done only when dmislng a tank empty would unduly delay the production of another Identical
lx (or other similar circum stance) .
The eost critical analyses are specific gravity and refractive index. Vhen these are correct! usually all otheq physical analy ses are correct.
Manual valvesf In relationship to the old
or automatic specifications (orior to H/l/70)
cutoff aeteri for Inerteen PPO and A13B3B,
are used in the specific gravity had to be
charging a
near the lower limit for these
mix tank.
two products, and the refractive
Specific
Index near the upper Halt.
gravities can! This meant specs, were difficult
be averaged. to achieve ano TCB and TTCB
Refractive
standard yields were often not
Indices can
averaged, hutl
with leas
accuracy and
reliability.
HONS 0 5 5 6 1 4
ST9SS0 SNOW