Document qmrpyx8qQKYaE7my9x8nO18ZR
474
CHAPTER 45
Table 1 .... Approximate Space Efficiency for Warehouses of 1 -5,000,000 Cu Ft Volume
Types CoSt A, Over Mod of Kb C& 0, (rg* Proportion m Aide
% Piling to Gran
SqFt
Ceft
Multistory, sprinklered, coils A heavy Multistory, sprinklered, coils B
Multistory, sprinklered, coils A & B Multistory, sprinklered, coils A & B
Multistory, unsprinklered, coils A A B One story, wide aisle, coils A
80 76
81% 75 77
73
57 GO 66%
59 63 57
two low ceiling areas adjacent to one high ceiling area, or one moderate height and one high ceiling floor. A basement may be provided below the freezer area to provide space for utili ties and cooler space.
For many years the accepted refrigerated warehouse plan was a basement and 3 to 12 or more floors above, with heights from 10 to 12 ft, floor to floor, and piling heights from
to'10 ft- These multi-story houses comprise by far the majority of prigting operating space. However, new materials and methods of construction, plus mechanized product han dling are tending to give the one story, or modification of the one story, the maximum capacity per dollar of investment with a minimum of overall operating expense including cost of investment, refrigeration, and labor.
The necessity of developing plant derigna to result in a minimum of overall costs has resulted in the practice of re stricting office facilities and utility areas to a bare minimum. Platform area is of major importance so as to assure ef ficiency in the operation of loading merchandise in and out.
BUILDING SIZE DETERMINATION
Size is generally rated in cubic feet of gross refrigerated
volume. Auxiliary space and walls are not included in this
volume. From a design standpoint, the utility of a warehouse
is more accurately stated by its usable piling volume and the
resulting load capacity in pounds. The ratio of piling area to
refrigerated square feet will vary greatly with floor plan and
type of construction, as deductions must be made for in
terior columns, normal aisles, access to piles of reasonable
depth, and dear space for air circulation between walls and
piles. Piling area will be between 0 and 80 percent of refrig
erated area, with 70 to 80 percent good for public warehous
ing. Piling height should be not less than one foot below over
head obstructions such as coils, sprinklers, or beams. Usable
height will be from 70 to 90 percent of floor to ceiling, resulting
in a piling volume of from 40 to 65 percent of gross refrig
erated volume, with from 55 to 65 percent good practice for
larger public warehouses (Table 1). A public warehouse carry
ing a variety of goods will average from 17H to 22 lb per cu
ft of piling volume on a net weight basis. Individual com
modities may be as low as 6 lb or up to 45 ib per cu ft. De
sign for expected tonnage of goods to be stored is preferable
to broad use of gross refrigerated volume.
Ceiling heights should be sufficient to allow for ample air
circulation above the pile. The space above the pile will vary
with the type of refrigerating equipment from one ft for an
unobstructed ceiling to three ft or more with overhead coils,
ducts, and sprinklers.
There is wide deviation among experienced warehousemen
as to what piling heights are most desirable for overall econ
omy. Height ranges from
to 20 ft are suggested. The
1962 Guide And Data Boole
Table 2 .... Piling Heights Using Pallets Without Auxiliary Support
Co<aatocGfy
Eggs, wood cases Apples, boxes Grapes, lugs Canned goods, cartons Tierces, on end Cans, 30 lb Butter, 63 lb cubes Butter, 63 Ib cubes Frozen fruits & vegetables,
cartons Frozen juice concentrate,
cartons Turkevs, boxes approx. 100 lb Boned meat, fiber cartons, if
flat
EMU High
Pile
12 12 21
4 12 12 12
18
PoOeh m P3e
3 3 3 3-4 4 3 4 6
3-4
4-5 3
3-4
Over. <4
Heigjtf, h
14% 13% 14% 15-18 13 14% 14 15
15-18
18 13H-15
13-15
differences are derived from the type of commodities h&.nrhpd, size of lots, and movement. The 8 to 10 ft range of the typical multi-story building has many adherents as an efficient height for either hand or mechanized handling.
An impressive brief has been made for the 6% ft height to provide for mechanical handling Qf pallets, one high, to be moved with light equipment in a multi-story building de signed for 150 lb per sq ft floor loading.
On the other side are many proponents of high piling, from 14 to 20 ft. The differences generally reflect the class of com modities stored, but some of the high piling group fed it worthwhile to make use of crates, braces, pallet corner irons, pallet racks and other devices to obtain height for com modities which do not pile well. It has also been brought out that, in the one story building additional height above 14 ft involves only the added height of wall and columns with comparatively small cost of construction and added refrigera tion load. Therefore, even partial use of such added height can well be profitable. Commodities best suited to high piling are solidly packed cartons, rigid boxes, 30 lb cans, or smaller cans in cartons, and barrels. The use of braces and other equipment allows high piling of many other commodities and packages, but at more cost for additional warehouse equip ment, labor, and lost productive piling volume because of the pallet area occupied by such devices.
Piling heights resulting from the use of pallets only for some large volume commodities are listed in Table 2.
INSULATION
The method and materials used to apply insulating ma terials to walls, floors, and ceilings need careful consideration. The main object is to secure an insulation envelope which offers a maximum of resistance to heat and moisture penetra tion. This requires adequate and good quality insulation, and a good vapor seal on the warm side of the insulation. It is well to emphasize that no insulation is better than its vapor seal, but some insulations are impervious to water vapor trans mission. It is still important to waterproof joints.
Once the water vapor passes the vapor barrier, a whole series of events begin to take place, ail of which are highly detrimental to the refrigerated warehouse and its operation. For example, during warm and humid weather with accom panying high dew-point temperatures, the water vapor cu-
%
Refrigerated Warehouse Practice
475
grating through the insulation will be chilled to its dew point
somewhere in the insulation, and will condense to water. In
the *=** of a cooler, the insulation will remain wet; while in a
freezer, ice will be formed. In both cases, the value of the in
sulation will gradually decrease until it is finally completely
destroyed.
Part of the water vapor entering the insulation, after con
densing or freezing, will revaporize or sublime. This vapor
rosy again condense as it advances from the warm side to the
cold side of the insulation. Additional infiltration moisture
follows and thus the insulation gradually becomes less effec
tive because of moisture buildup. Some moisture passes into
the refrigerated space and collects on the refrigerating coils,
but this action is not usually sufficient to dry out the insula
tion. In the
of walls with insufficient insulation, the dew
point of the migrating water vapor may, during certain pe
riods, be reached at the inside wall surface and result in con
densation and freezing at this point. This can also happen to
a wall which originally had adequate insulation but which,
through water or ice formation in the insulation, has lost its
insulating value. In either case, the ice deposited on the wall
will gradually push the insulation and its protective covering
away from the wall until finally the whole insulation struc
ture collapses.
A discu^ion of the value of protecting the insulation would
not be complete without emphasizing the importance of water
tight roofs with well designed and constructed flashings,
water-proofed or water repellent walls, etc., all of which should
receive thorough consideration.
Experience with various designs and kinds of insulating ma
terial applied to refrigerated spaces indicates that the greater
the care used in its installation and in its protection from dam
age through exterior causes, the longer will be its life and use
fulness.
Consideration is now being given to free standing insula
tion walls where no masonry is used. Inside buck-stays can
he used to provide structural support for the walls. The warm
aide of the insulation is, therefore, left exposed for application
of the vapor barrier and later maintenance repair if this be
comes necessary.
Insulating materials preferably should not be placed on
ceilings but on the floor or roof above, [f that construction is
oot feasible and the insulation must be installed on a concrete
criling, the first layer should contain wooden strips fastened
to Uie ceiling to which the insulation can be securely nailed
besides being suitably adhered in place.
Methods of application, and the structure to carry the
insulation will vary with the type of insulation, but with each, skill of application and attention to effective air and vapor seals are essential to continued effectiveness.
Advisable thickness of insulation varies with average and extreme temperatures of the location, but is somewhat more than would give minimum cost of insulation and refrigeration. The additional protection is advisable to avoid localized warmer areas.
Insulation and vapor barriers are discussed in Chapter 22 of the 1961 Geode And Data Book.
CONSTRUCTION TYPES Aftff construction has been used formerly because of its initial low cost. The fact that this construction is not fire proof is a major fault. Also, after 20 years or more, the up keep becomes high. Failure occurs when woodwork is exposed to dampness, especially where beams and girders pas through the insulation and rest on the bearing walls, or exterior col umns, if any. It is now customary, in repairing such struc tures, to water-proof the ends of beams and girders where they pass through insulated enclosures. Curtain wall construction, as shown in Figs. 2 and 3, is dis tinguished by the fact that the exterior columns of the build ing are split, the outer walls being earned up independently of the rest of the building. The floors, roof, interior columns, and the inner portion of the wall columns form one structure which is surrounded by the independent exterior walls. The insulation forms a continuous envelope between the build ing proper and the outer shell and is applied on the inner face of Uie outer shell. Split columns are also often used at stair and elevator shafts and between the various sections of a large warehouse to provide as nearly as practicable an unbroken and unpierced insulation envelope. Even in this type of building, com promises must be made, as it is impossible not to pierce the insulation envelope with the building construction at some points. While insulation for buildings of the curtain wall type is in most cases applied in sheets stuck to the curtain and partition walls, a number of buildings of this type have been insulated with loose fill material. The curtain wall should have a posi-
Rg. 3 ... Section of Multi-Story Building with Curtain Wall Construction