March 30, 1970 Bulletin B-?577 PLAINTIFF'S EXHIBIT KN-33 1 To: Pyrospray Manual Holders Re: 1970 Pyrospray Brochure Attached you will find a copy of the 1970 Pyrospray Brochure which has been inserted in the 1970 Sweets Catalog. At the time this brochure was sent to press, the binder problem which developed with Bonded "K-dB" had not been encountered. At this time we believe we are well on the way to solving the prob lem that developed and expect to be in a position within the next 90 days to inform you accordingly. LCJ:jca Enc. X0349702 T- ..*> v\tt- *>' V ' ' ; V'yj .Vfe: r.-li :. ^( - *T. . i'j -VC;1 >?#*.._ V - or-. .*r *' crrS^i: rf. - . . ii.~s\'t v? -................ '....V ^ : - . , m'm'^ : -*`s iV . . :.*. .fZ7 B 001945 # fireproofing: condensation control thermal insulation It t ae2 - - - -r ,':. .:~1M -l - ' ; -. /nrzi^nzDrx nr .: >/ C--. ; t-, ,\! |j - v-..r . (\ : f-- ; r-- ; . * ji i \ '-. --.i .: \ \ H corporation; *&*&&*>< SOUND CONTROL DIViSIOJ : z-J'. a:: :-M W-vf- '**. ^z*+> ^ri. ; v.:?.;.Vi. iVSEBOl v ;> 1 m 9703 %L "w 1 PYROSPRAY RATIONAL SUSIUMIC AOCtlTT nlNir OKMTIOM UlLDtMO Oadftartwr*. Md. ArrftMact: BUM. Aattieord * MR*. Waanwifton. O.C. Ganaral Cawttactar Chaitaa H. TomokMa Co- WaalMiton. O.C. Applicator Mton Inautatan and Sapety. Inc- Aaknton. Vo. Mt OUVCB P1AZA Ntlbtflh PtMiyMM* ArcMtact: Wdham Lncji* and Ataociatam. Mas York. Haw YarA 6arural Contractor Owact Conatructan Co- Pittaourffi. FannaftmMa Aooacator CaiMt Scania. Me- AitUMrgn. ^annaytwi. BIDWUT riSCUL BUILDING HlffHMROii. illWHMKl AKMKt: Wilburn McCwwiefc. St. Lftwil Maliurt Oifttril Contractor: Anodaon Construction Co. MinMiwm. Minnaooia Aopfccotor: tntmation So*oa Company. Mutnoopeba. Minnaiaf WUTT AMO WMITMCT tot Hartford. Connecticut Arctutoct: DuSesa Auooatu, Hartford. Conoocttcut Gonorai Contractor. Coorf* A. FuOor Co. Inc. Coct Hartford, CawwcbciH Applicator: H. Carr and Sana* Inc. Providonco. Khoti Ialand 349704 n I PYROSPRAY products ore blends of virgin asbestos fibers, re-v.-r* fined white mineral fibers, and inorganic binders. - * Developed for the many economical spray applications required in to-->T day's construction market, the machine applied products are incombus^.^ tibie, chemically stable, light-weight, rot-proof, vermin-proof, unaffected by water and possess excellent fireproofing, thermal and acoustical^ values. .''-i '*y The light weight monolithic blanket of fiber, Is unaffected by expansion and contraction of base material. r.>.: -Decorative colors and textures can be made to its surface by various tamping or spray painting procedures. KEENE manufactures three blends of PYROSPRAY. A brief discussion' of each follows in order to assist in the evaluation and proper selection' of the material best suited.for various types of field applications. `U- -V*^ PWLAWD inCMHTS NATWMt BAM Cdatri Urtibai Barati Mid Cmvry Mh 4 tom, Nov Torft, Mom Voift Cowtnctor Abvcthw and Tmor, lodOA, Mac atidCaaam, tote* I types available: type I-- Fireproofing . This premium blend of combustible fibers has been for mulated and tested by Underwriter's Laboratories, Inc. primarily for use in fireproofing applications of steel beams and columns, structural deck systems and venti lating ducts. Sprayed with modem application equipment, PYROSPRAY type I does not require the use of an ad hesive bonding agent and in most fireproofing applica tions does not require tamping. PYROSPRAY I can also be used for insulation applica tions, acoustical treatment and condensation control^ These applications, which require the use of a Pyrosprayf adhesive bonding agent, can be finished in fine, medium^ or coarse travertine textured surfaces. PYROSPRAY I is available in 50 lb. paper bags. See charts and additional data on pages 4 L 5 of this] catalog. Note: PYROSPRAY I may also be used as a base coat for^ a Type S/I acoustical application. ` .WV** VAjJU type S -- Acoustical (Hard Finish) ..'-.-.sKtWSC This blend of incombustible fibers has been formulated primarily for acoustical treatment where a hard surface or finish is required to offer greater resistance to abrasion. PYROSPRAY type S is of a heavy density weighing 1.5 lbs per board foot Sprayed wtih modem application equip ment, this blend requires the use of an adhesive as a bond' ing agent and can be finished in fine, medium or coarse I .7i :"o 1 _/-. i i 1 travertine textured surfaces. ..7 .. .- .-J Additional finishing can be made with a spray 'of transpar^ ent sealer for a natural off-white finish, or Latex paint.'! EYROSPRAY S is available in 50 lb. paper bags. See charts and additional data on page 6. . ' ~v -- Thermal Insulation and Acoustical Treatment: This advanced, factory-formulated product is composed of asbestos-free, inorganic white mineral fibers, blended with chemically stable binders and corrosion inhibitors. When machine sprayed, application is dustless and void of offen sive odors; forms a light weight, incombustible, monolithic blanket with an 0.26 K value. This product was designed to meet the modem thermal insulation and acoustical treatments required by the metidj building industry. Bonded "K-dB" Hardcote also is available and is rec mended for wall treatment where a hard surface or finishes* is required to offer a greater resistance to abrasion, >*s3S|: For additional information, please refer to the Bonded "K-dB" PYROSPRAY catalog. r 0349705 ft Pyrospray Characteristics^ Fir* Hazard Classification -- Pyrospray rated incqmbua- . tibia by Underwriters' Laboratories,incorporated.'5ip :' v-x. . Fire Retardancy --.Tests by Underwriters'lLaboratoge, Inc. prove Pyrospray Fireproofing Fiber,to be'of iupenoi efficiency. Resistance to Corrosion -- Pyrospray' Mineral.Rbefjco^ tains additive corrosion inhibitors which afford prbtectior to steel against rusting.. " Resistance to Air Erosion--Laboratory tests *prove.Py spray Fireproofing effectively resists erosion^dustirig^ flaking due to high velocity air movement Excee<f?GS' requirements. Pyrospray Adhesion -- When tested in accoidance MIL-C-2861 Specification the adhesion^exceeds^^S, . To Steel --191 lbs. per square foot To Painted Steel -- 90 lbs. per square foot Hi?;r2sL. To Galvanized Steel --137 lbs. per square foot^rpS Pyrospray meets all requirements Bonded Impact Test--G.S.A. :jPs <-? Specification 224-3A Section 05 (3) Deflection Test -- G.S.A. Specification 224-3A Section 05 (2)' ' Efficient Thermal Insulation -- Pyrospray with.'a K valueof, 026 BTU/hrVsq.fL/ degree F/Hnch thickness, provides highly effective thermal insulation (see page 6), High Acoustical Absorption -- Pyrospray Fiber coatings; provide excellent acoustical correction due to high sound absorption (see page 6). " Condensation Control -- The natural physical character-, irtics of Pyrospray permits the application to Icritickljrujf faces for control of condensation. Light Weight -- Pyrospray Mineral Fiber Fireproofing ., stalled adds less weight to the structure than any"'other type of fireproofing. Pyrospray 1" thick, weighs'1. Ib^per board foot .'r-v:V East of Application -- Pyrospray Fireproofing isJ machine applied directly to steel surfaces in. one appiicatio^Speed of application and ease of clean-up permit^a siT stantial reduction to normal construction schedules""'**'3 Economical -- Pyrospray Fire Resistance applicatibnsjre* quire less materials and with fast machine^application methods, the fireproofing installation is accomplished^.? less cost. sjj-.ic';"' "" Safety and Versatility -- Contact Pyrospray Fireproofing permits unrestricted ceiling design and location of parti-'2, tions. Remodeling of area can be accomplished without j damage or removal of the fireproofing, and safety of the*' structure is always assured. Pyrospray Sealer -- Pyrospray Transparent Sealer as ap-f plied to Pyrospray fiber coatings is rated incombustible'!., by Underwriters' Laboratories, Incorporated. iw description Girders or Spandrels Columns Cellular Steel Floor or Roof Composite Design (3) Blended Fluted C-.-.-lular Floor or Roof Units ilended (4) Fluted-Cellular Floor or Roof Units - ' posite Design (5) Siended Fluted-Cellular Floor or Roof Units Blended (6) Fluted-Cellular Floor or Roof Units Air Inlet Cover Air Inlets Air Cells Air Outlets A;r Ct-lls Structural rieader above Fire Resistant Ceiling rating 4 hr 2 hr 3 hr 4 hr 3 hr 4 hr 3 hr 2 hr 3 hr 3 hr * 3 hr 3 hr 3 hr 3hr 3 hr 3 hr 3 hr 2 hr thickness ) 1" f (2) nn 2Vs" w vr 3/e" VfcT in flutes) 'fz Vf (rin flutes) W' (rin flutes) VuT (1" in flutes) 1" Board r W 'w w jT ($49707 * authority ---- " ~rv UL #R4609-13 UL #R4609-11 & UL #R4609-12 1 UL #R4609-9 UL # R4609-9 UL #R4609-5 UL 5r R4609-13 UL #R4609-5 UL *R4609-6 UL #R4609-10 UL # R4609-15 * UL "R5257-1 - -- ` - -* UL #R4609-10 UL #R5079 UL #R4609-10 UL *R4609-10 UL #R4609-10 UL #R4609-10 UL #R4647-13 iissionl CONSTRUCTION UNINSULATED Metal roof deck or siding (corrugated) 1-28 Concrete roof slab 2" thick 0.79 4" thick 0.70 6" thick 0.63 8" thick 0.57 Poured gypsum roof deck -- 2V*" thick 0.38 Wood frame construction, 1" wood roofer, airspace, */'' gypsum bd. 0.31 8" common brick wall 0.41 8" cinder block wall 0.39 PYROSPRAY TYPE I OR BONDED "K-dB*' Yi* IV*" 0.37 022 0.15 0.12 0.31 020 0.14 0.11 020 0.19 0.14 0.11 028 0.18 0.14 0.11 027 0.18 0.13 0.11 0.22 0.15 0.12 0.10 0.19 0.14 0.11 0.09 023 0.16 0.12 0.10 022 0.16 0.12 0.10 THICKNESS BASE 125 *U" Metal Lath .71 V." Solid (painted) .03 */*" Solid .07 COEFFICIENTS 250 500 1000 2000 .66 .76 .95 .91 23 24 27 .74 28 .70 24 .90 4000 NRC iTSr tfigSL .85 .80 .85 .45 Eg .80 .75 a** FLAME SPREAD FUEL CONTRIBUTED SMOKE DEVELOPED PYROSPRAY FIBER 15 15 PYROSPRAY SEALER BONDED "K-dB* PYROSPRAY 15 10 15 20 rCo34y m ---------------- -- ggggg -ARCHITECTURAL SPECIFICATIONS sPraV insulation |f PYROSPRAY type L -- fireproofing BONDED "K-dB" PYROSPRAY PYROSPRAY type S. -- acoustical treatment (select relevant paragraph) Scope: The work required under this section shall include furnishing all materials, labor and equipment necessary for the application of sprayed-on mineral fireproofing -- ther mal insulation -- acoustical treatment -- in accordance with the specifications, drawings, and terms and conditions of the contract documents. Work of other sections: The installation of all bases and surfaces to which sprayed-on mineral fiber is to be applied, as well as hangers, clips and other mechanical supports re quired for suspended ceilings, piping, ducts, electrical work, or other mechanical devices shall be completed by others prior to the installation of sprayed fiber. Utilities, including heat, light, electric power, and water shall be furnished by others. Contractor's Qualifications and Responsibility: The con tractor shall be a licensed applicator of the manufacturer and use materials and equipment approved by the manu facturer. The work performed shall be in strict accordance with the manufacturer's instructions and approved speci fications. The contractor shall examine all surfaces of areas to be sprayed and notify the General Contractor of the exist ence of any conditions which would prove unsatisfactory for proper application of sprayed-on mineral fiber. All unsatisfactory conditions must be corrected before pro ceeding with the installation of sprayed fibep The Contractor shall coordinate the work of this section with the work of other trades, so as not to delay progress of the job. Applicable Code & Specifications: All Pyrospray Type I Fireproofing installed shall conform to the applicable re quirements of the Building Code and all authorities having jurisdiction. Should the requirements specified herein dif fer from the requirements of the Authorities having juris diction, the more stringent requirements shall apply. (list Fire Resistance Ratings desired) Prior to the application of Pyrospray Type I Fireproofing, the Contractor shall furnish the Architect with evidence that the proposed installation to the structural system as shown in the drawings has been approved by the Authori ties having jurisdiction. Test data indicating the resistance to air erosion and non dusting properties of the mineral fiber coating shall be fur nished to the Architect assuring the safety of the applica tion in air plenum areas. All mineral fiber applied as thermal insulation or for acous tical correction shall be rated as incombustible by the Underwriters' Laboratories, Inc. (For Acoustical and Thermal Insulation only) The fiber application shall be--------inch thick and have a thermal conductivity (K) of not greater than 0.26 BTU/hr^sq. ft/ nch thickness. The application shall have a minimum noise reduction coefficient of --__ Materials: All Sprayed Mineral Fiber shall be Pyrospray as manufactured by Keene Corporation, Princeton, New Jfersey or approved equal. The fiberfs) shall be quality controlled mixture(s) of virgin asbestos fibers and mineral wool fibers, blended with inorganic binders and rust inhibitors. The material(s) shall be supplied to the job site in sealed paper bags, properly displaying appropriate labels for the application specified. Adhesive -- for applications other than fireproofing, Bonded "K-dB" Pyrospray adhesive as supplied by Keene Cor poration or an approved equal shall be used. Transparent Sealer --Sealer when required shall be rated incombustible by Underwriters' Laboratories, Inc., such as -Vinrez 3R-58 PYROSPRAY Sealer supplied by Keene Cor poration or an approved equal. Preparation of Surfaces -- Pyrospray Mineral Fiber shall only be installed to reasonably clean surfaces, which are free of. grease, dirt, oil, loose paint, or other material which may prevent good adhesion. For applications to gypsum board all joints should be taped or sealed. For direct application to metal lath, high rib lath, should be used and securely fastened to channels set on 12 to 16 inches O.C. (for all exposed finish applications to lath, a scratch coat of sand and gypsum is preferred prior to fiber application.) Application: The application of sprayed fiber shall be in accordance with the specifications and the instructions of the approved manufacturer and of the licensed or fran chised contractor. The fiber shall be applied with manu facturer's approved equipment Pyrospray Type I Fireproofing fiber may be applied as fireproofing to steel surfaces without Pyrospray adhesive, providing the steel surface be wetted with water, and the fiber sprayed immediately onto the wetted steel surface. The total required thickness of the fiber shall be applied in one spraying operation and finished by mechanically tamping to the required thickness or water tamped by ap plying a light spray of water. (Dependent upon .desired, finish or ULI test procedure.) Pyrospray products other than Bonded "K-dB" applied as thermal insulation or acoustical correction should be ap plied using Pyrospray adhesive as a bonding medium. Fiber shall be sprayed onto the wet adhesive film to a thibkness to produce the specified thickness after tamping to a fine -- medimum -- coarse travertine finish. Incombustible transparent Pyrospray sealer shall be spray applied to produce a film of 3 mil thickness, or the installed fiber be spray painted with a pigmented latex-type paint to a desired color. Pyrospray Type S/I Acoustical Finish A base coat of Pyrospray Type I be applied as stated above including a leveling tamp. Pyrospray Type S Fiber would be sprayed onto the water wet surface of the base coat and tamped to'produce a fine -- medium -- coarse travertine finish of 'A inch thickness. Finished surafce shall be sealed with latex-type paint or with Pyrospray transparent sealer. - 0349709 KEENE \\\\\\\\11 11lit// . \\\\\ \ t 111 /////// \\\\\Wl 11 /////// \\\\\\\\iu////// WWUMII/////// wwuu///////' 'mm/zm' In addition to the~quality_fine of J^YROSPRAY jJi^ucts, /^; ^^^ ^ Keene Coiporation,^Sound 'Control Division'provides a'5^^ complete lineof acoustical 'products. See''catalogs in' ' . Architectural 14a/Ke~and Plant Engineering 12a/Ke Files. For the namt'ef the'approved PYROSPRAY contractor 'JP'-r-frArt*-' b> your mrea contact: .......... I Member ef SPRAYED MINERAL FIBER MANUFACTURERS ASSOCIATION, INC. TWX: ($10) j-.i.'; . .-v