Document qmax1myb7qnnM57BBv4bDOEyq
402
CHAPTER 21
1948 Guide
''
-Nb" z'oir -space-open
fnsuhted *jith airspace or coh ered W)1h magne sia, asbestos, or sand.
Inner Oner-from fop casing ring to grate level
/fetof casing
Fig. 3. Details of Furnace Bonnet, Casing, and Foundation (From Gravity Code and Manual)
Supporttojo/st or co/hr ~
2' or/ess.
Masonry wall,
fletal th/mb/e. Collar
HUjoints Taped with
asbestos paper
K'lr//gn,btcotlar
Insulated with s layers of air ce/losbestos paper whenp/pe passes thru unbeated space.
Fig. 4. Details of Bonnet and Leader of Gravity Warm-Air Furnace (From Gravity Code and Manual)
Figs. 3 and 4 show recommended practice as given in the N. W.A .H. &A.C. Assn. Gravity Code and Manual. For construction, design features, and ratings of gravity furnaces see Chapter 18.
Carrying Capacity
The Btu carrying capacities of the selected warm air and return air combinations are shown in Tables 6, 7 and 8:
Table (F--Combination Numbers 1 to 5--Warm Air Carrying Capacities to first story registers with 1 to 5 elbows and with leaders 4 to 24 ft long.
Table 7-7-Combination Numbers 11 to 16 and 21 to 247-Warm Air Carrying Capaci ties to second story registers with 1 to 5 elbows with leaders;4 to 24 ft long.
Table fc--Combination Numbers 31 to 38--Return Air Carrying Capacities for types A, B, C, D, E, and F return combinations.
Gravity Warm Air Systems
403
Table 6. Warm Air Carrying Capacity, Btu Delivered, First Story Registers3 Length 0} Leader Pipe--in Feet
Combi
nation
No. .
No. OF Elbows
4 Ft
6 Ft
8 Ft 10 Ft 12 Ft 14 Ft 16 Ft 18 Ft 20 Ft 22 Ft 24 FT
1 6,020 5.850 5,680 5,510 5.340 5,170 5,000 4,830 4,660 4,490 4,320 2 7,620 7.400 7,180 6,970 6.760 6,540 6,320 6,110 5,890 5,680 5.460 3 1 9,400 9,140 8,870 8,600 8,340 8.070 7,810 7,540 7,270 7,010 6,740 4 13,360 12.970 12,590 12.210 11.830 11,450 11,080 10,700 10,320 9,950 : 9,560 5 17,520 17,020 16,530 16,040 15,550 15,050 14,550 14,050 13,560 13,060 12,560 1 5,850 5,660 5.490 5,330 5,160 5,000 4.840 4,670 4,510 4,340 4,180 2 7,360 7,150 6,940 6,730 6,520 6,320 6.110 5.910 5,700 5,500 5,290 3 2 9.090 8,840 8,580 8,320 8,060 7.800 7,550 7,290 7,040 6.780 6,520 4 ' 12.910 12,540 12,170 11,800 11,430 11,060 10.600 10,320 9,950 9,580 9,210 5 16,940 16,450 15,990 15,500 15,040 14,550 14,080 13,600 13,120 12,650 12,150 1 5.620 5.460 5,310 5.150 4,990 4,830 4,670 4,510 4,350 4,190 4,030 2 7.120 6,910 6,710 6,510 6.310 6,110 5,900 5,700 5,500 5,300 5.100 3 3 8,780 8,530 8,280 8,030 7.780 7,530 7,290 7,040 6.800 6.550 6,300 4 12,450 12,100 11.750 11.400 11,050 10,700 10,350 10,000 9,650 9,300 8,950 5 16,360 15,900 15,440 14.970 14,510 14,050 13,600 13,130 12,660 12,200 11,760 1 5,420 5,260 5.110 4,960 4,800 4,650 4,500 4,350 4,190 4,040 3,890 2 6,860 6,660 6,460 6,270 6,080 5,890 5,690 5,500 5,300 5,110 4,910 3 4 8,460 8,200 7,980 7,740 7.500 7,260 7,020 6,780 6,550 6,310 6,070 4 12,010 11,670 11,330 10,990 10,650 10,310 9,970 9,630 9,290 8,950 8,610 5 15,770 15,320 14,880 14,420 13,990 13,540 13,100 12,650 12,200 11,750 11,310 1 5,240 5,090 4.940 4.790 4.640 4,500 4,350 4,200 4,050 3,910 3,760 2 6,630 6,440 6.250 6,060 5,880 5,690 5,500 5.320 5.130 4,940 4.750 3 5 8,180 7,950 7,720 7,490 7,260 7,030 6.800 6,560 6,330 6,100 5.860 4 11,610 11,290 10,950 10,620 10,300 9,970 9,640 9,320 8,990 8,660 8,320 5 15,250 14.800 14,380 13,950 13,520 13,090 12,650 12,230 11,800 11,370 10,940
^Additional values for 6 and 7 elbows are given in original Manual.
Table 7. Warm Air Carrying Capacity, Btu Delivered, Second Story Registers* Length of Leader Pipe--in Feet
Combination
No.
.
. No. OF
Elbows
4 Ft
6 Ft
8 Ft
10 Ft 12 Ft 14 Ft 16 Ft 18 Ft 20 Ft 22 FT 24 Ft
11-22 12-24
14 15 16
8,370 8,140 7,900 7,670 7,430 7,190 6,950 6.710 6,470 6,240 6,000 10,040 9.760 9,470 9,190 8,900 8,620 8.330 8,050 7,770 7,480 7.200 1 11,710 11,380 11,050 10,720 10,390 10,060 9,720 9,390 9,060 8,730 8,400 16,200 15,750 15,300 14,840 14,380 13.920 13,460 13,000 12,550 12,100 11,640 18,920 18,390 17,850 17,310 16,780 16,240 15,710 15,180 14,640 14,100 13,570
11-22 12-24
14 15
16
7,940 7,720 7,500 7,280 7,050 6.830 6.600 6,370 6,150 5,930 5,700 9.540 .9,270 9.000 8.730 8,460 8,190 7.920 7,650 7.380 7.110 6.840 2 11,120 10,810 10,500 10.180 9,870 9.550 9,230 8,920 8,610 8.290 7,980 15,400 14,970 14,530 14.100 13,670 13.230 12,800 12,360 11,930 11,500 11,070 17,980 17,470 16,960 16,450 15,950 15,430 14,830 14,420 13,910 13,400 12,890
11-22
12-24 14 15 16
7,530 7,320 7.110 6,900 6,680 6,470 6,250 6,040 5,830 5,620 5.400 9,030 8,780 8,520 8.270 8,010 7,750 7,500 7,240 6,990 6,730 6,470 3 10,530 10,240 9,940 9,650 9,350 9,050 8,750 8,450 8,160 7,860 7,560 14.580 14,180 13,780 13,370 12,950 12.530 12.120 11,710 11,300 10,890 10,480 17,040 16,550 16,070 15,580 15,110 14,620 14,140 13,660 13,180 12,700 12,210
11-22
12-24 14 15 16
7,120 6,920 6,720 6,520 6,310 6,110 5,900 5.700 5,500 5,300 5,100 8.530 8,290 8.050 7,810 7,570 7,330 7,080 6.840 6.600 6,360 6,120 4 9,950 9,670 9,390 9,110 8,830 8.550 8.260 7.980 7,700 7.420 7,140 13,780 13,390 13.000 12,610 12,220 11,830 11,440 11,050 10,670 10,280 9,890 16,080 15,620 15,170 14,710 14,260 13,810 13,350 12,900 12,440 11,980 11,530
11-22 12-24
. 14 15 16
6,700 6,510 6,320 6.130 5,940 5,750 5.560 5,370 5.180 4,990 4,800 8,040 7,810 7,580 7,350 7,130 6,900 6,670 6,440 6.220 5,990 5,760 5 9,370 9,110 8,850 8.580 8,310 8,050 7,780 7,510 7,250 6,980 6.720 12,970 12,600 12,240 11.870 11,500 11.140 10,770 10.400 10,040 9,680 9,310 15,140 14,710 14.280 13.850 13,420 13,000 12,570 12,140 11,710 11.280 10,850
aWhen floor registers are used, see Fig. 2. bNo. 21 for Btu values multiply 11-22 values by 0.83. No. 23 for Btu values multiply 12-24 values by 0.83.