Document qmEO4Ko3jYRDwegmZ8qLwxjE

insured Armstrong Contracting & Supply Coapany maw cmcE addsess 120 No. Lins Street, Lancaster, Pennsylvania PLAINTIFFS^ ,S8t' location (Preset er Jot>) Dupont Company, Ola Hickory, Tennessee report prepared BY; tf. A, Sharp DATE: 7-12-68 acent Alexander 4c Alexander KEY personnel INTERVIEWED (Nonet and r;r/*} S.E.Dyer, Ifen&ger, Walt Shipley, Safety Director for Dupont and Prank Redmile, Field Project >2anager " I. CURRENT OPERATIONS Insulation of pipes, ducts arri equipment. 1 COMPENSATION, BODILY IN1URY AND PROPERTY- DAMAGE HA2ARDS a* Mier Employee Hcserds (B* tptteific): Inhalation of dusts involving calciia silicate and asbestos. L. Hew ot*\Wv* feeing twrttohetf Through housekeeping, vacouiraing sxti an exhaust system, e. Bodily Injury osi Property Damage Hiardj (Be ?///; None observed. Visitors to job site are not permitted. &, He* ore these feeing controlkd? Through observance of "no visitors" allowed signs. \ OPERATIONS e. Whet new excretions will star! before your neat visit? % b. How will Injured control Major Hoxtrii anticipated? Continuing as in 1. above. As in (b) above. PLAINTIFF'S EXHIBIT . ACCIDENT DATA Discussed with: Nome e. Cumulative Summery Iron job storting date 4-58 Lost-time Accident* _______ Last-time Days IS Medicel-enly Accidents _______ J- Bodily Injury end Property Damage Accidents _ XL Autobile Aceidentj SL. - _&Yr05S3ft TUle b. Predominating Causes? 1. Employees. Inattention t. Bodily Property QemegO 3. Automobile - . SAFETY MEETINGS * c. Frequency of Supervisory Mee&tg* weakly*' b. Conducted by; Nome Dupont Safety Personnel 2c Insured Title (Armstrong) e. Dole of lost mealing 7-6-68 d. Did subcontractor* Representative* attend? Qc] Ye* Q No . Are meetings Wt-pUnned ond conducted? 7** f ) No f. When did you lost attend? Have not attended f. Describe frequeacy end actuce of "Tool Box" steeringv. Meekly 374152 WV-05530 PROGRAM EFFECTIVENESS Ar* you presently satisfied wiiH scheduling, thoroughness and follow.** of Insured In the following to** Control Activities? e. Accident Investigation Use I Personal Protective Equipment (3r Hecetsory Action Token Job or Dept. Safety Inspection* F<n end Explosion Controls Equipment Operation ond Maintenance Driver/Operator Selection & Training Now Employee indoctrination s* Qv y. Housekeeping Conditions I S. IsInsured's program effective? I xl Ye* Cm If set, what are its weaknesses? (Bn aptclflci - No i. Kftwe you submitted recommendations for Improvement? 23 Ye* Q No When? 7-12-^8 f. Were they discussed this visit? [p Ye* No if yes, with whom? Hr. Shipley, Mr. Reds&le' k Mr. Dyer. g. What wo* hi* reaction? very good RECOMMENDATIONS e. Was copy of C-1488 left oi location? Q Yes S3 Ho ' h. Was it necessary to submit recommendations to Insured's headquarters ^ CDS3 ** He Vf,*YwH, atoeh copy of Form C*2T2 to each copy of report* c. List outstanding essential recommendations by number, dote first submitted, with brief rewarding bone i. ASSISTANCE REQUIRED FROM ATNA LIFE AND CASUALTY HOME OFFICE IRrqvhhirzA yowrt AA-JdS should fee used when c.*J*r^a **> baohf.'*. pc*'*'*, cuppt/e*) ?. Summary {answer In tuffIcSant detail but do not repeat intn"8'/on e&ave* S??3C ATTACHED PAGE e. Management attitude ond porticipotlon. b. What did yoo contribute this v Other items el special interest. e. Distribution , Q] Home Office Agent fT] Writing Office Baltimore Insured gT)fNomes) L3.2filler. fiapt,S. E>fogE*. Kr. M.*- H^rf^rth, Tn*?. t/rrr R. B. Ross. District.Ser..,, 0they gQ/tfameJ 'RearHny Pa. r N**hviVVfe Rft * DO NOT WRITE IN THIS SPACE 3741 sr- fl II t^ .. SUMMARY 9M Dupont Safety personnel has always been most helpful in assisting those contractors doing work for them within the plant* This results in a very good safety attitude on the part of the management of Armstrong Contracting & Supply Company. This is I evident in a lack of accidents on this job* 9 <b) Discussed thoroughly the National Insulation Manufacturers Association pamphlet regarding >cehousing, storage, handling, fabrication in job site shops, application, handling of cements, spraying, stripping and cleaning up. Then made inspection of fabrication shop and spraying operations in the power plant. 9 (c) Air samples within the fabrication shop are taken over an 8 hour work shift at least once a month. Samples analyzed at the University of Pittsburgh. Those saaples recently taken tested cut to where ppa were well below the maximusallowabie. Fabrication shop has vaceuura available for catching dust as asbestos is cut and in addition has exhaust fens at top of building near roof and at a lower level. Unsafe conditions noticed concerned housekeeping and the use of a 30s1 y-** stal fan for cooling purposes. This fan was scattering calcium silicate and asbestos dust into the air resulting in a, very dusty work area. 374154 Armstrong Contracting ft Supply Coopery 120 Ho. lisa Street Lancaster feonsylvsnia tf. A. Sharp Dupont Cexpasy, Old Hickory,Tennessee 7-12-68 ESSENTIALs 1. Dost, as noticed in the fabrication shop at the Dupont plant in Old Hickory, Tennessee, should be rasreved frea floor, tables and ledges by aeans of a vaccuusu This should be done on a continuing schedule throughout the day to prevent excessive dust in the air. *2* The 30* pedestal fan located in the fabrication shop should ba recoved froa its present position and should be so located that it vill not blew * dust into the air. 374151: