Document qm78ejoKjjdVe8mD6NpQG3Dyx

Lt/ > '> i`Jl~<>*yyA>Viij'iillfli* 'AW'-^-'f ^^nSlA^i1 INSIDE FRONT COVER: Contents (to be determined) PAGE 1 HEAD: . The _Pvi)R'AU^ Air Compressor Pact Finder COPY: ... is designed to make the many facts about Pydraul AC-A fire resistant lubricants for air compressors--Pydraul ACA Ac-A 02.5* Pydraul AC Winter Grade 28 and Pydraul 625--easy to find. These safety lubricants for air compressors were specially developed to offer you: * Safety from Fire and Explosion Pydraul eliminates combustible mists and minimizes carbonaceous residues -- greatly reducing the threat of compressor fires and explosions. * Lower Maintenance Costs ' Pydraul eliminates deposits on exhaust valves, in coolers and in piping. You save the costs of compressor downtime and cleaning. Many compressor users find "that these savings <? alon^ Justify using Pydraul lubricants. 0068543 TOWOLDMONOQ56761 P. 2 Head: Copy: How Compressor Fires & Explosion Occur compressor --------- Every theory about the mechanisms ofires and explosions Ihhm hold one idea in common: petroleum oils are direclty involved. Subhead: Petroleum Oil Mists &. Fllffis Mist and accumulated films from petroleum oil in compressor systems can, under a variety of con ditions, break down into combustible gases and carbonaceous residues that can ignite and produce an explosion, a receiver fire--or both. The U. S. Bureau of Mines1 found that carbon deposits in air compressors lubricated with petroleum oil form a "carbon-oxygen complex." Oxidation forms this complex, and accelerated by heat, this oxidation process can lead to an explosion. Subhead: The Shortcomings of Safety nevines Safety devices do not completely eliminate fire and explosion possibilities. A r-OGent study on "The Mechanism of Explosions In Starting Air Lines,"2 based on an exhaustive survey of compressor opera tions at 53 companies, reports that a stuck or leak ing air check valve permits the engine being started to pack the section of line between the check and air timing valve with an explosive "oil residue-air" mixture. A pressure wave will force this mixture upstream into the main air line--and coupling this with good flame propagation in the power cylinder, the condition is laid for explosion in the pipe system. Air line explosions and fires may even occur with out the engine being started or before the ignition is turned on.2 Carbon and rust particles in a "hot" air line, due to operating an overheated compressor too long--hardly an improbable condition--can be come saturated with oil, and with the flow of start ing air, can cause these oil-saturated particles to flame. Subhead: Explosion Tests at 1300 PSI The Walter Kidde Company, makers of fire ex tinguishing equipment, warns in a study3 that users of high pressure air should guard against introducing a shock wave into high pressure lines by suddenly opening a plug cock in air compressor systems using petroleum oil. This report showed that in a 1-inch diameter tube, the inside walls filmed with oil, a sudden admission of air at pressures above 1300 psi caused combustion. 0066544 How can you eliminate the conditions that cause fires and explosions ' in air com^pressors? Eliminate the source of carbon deposits, the basic cause of most air compressor disasters--petroleum oil. Substitute fire- and explosion-resistant Pydraul. TOWOLDMONOQ56762 ? v CoiM 1. "The Carbon-Oxygen Complex as a Possible Initiator of Explosions and Formation of Carbon Monoxide in Com pressed Air Systems," by Busch, Berger, and Schrenk, Bureau of Mines paper R.1.4465, June 1949v 2. "The Mechanism of Explosions in Starting Air Lines," by Ridgway, Robert S., Petroleum Refiner, June 1958. 3. "Oil Combustion Phenomena in High Pressure Air Systems," M. W. Weibel, Walter Kidde & Co., Inc., Report R-831, copyright 1952. 0068545 TOWOLDMONOQ56763 TABLE 1 PHYSICAL PROPERTIES Appearance Spec. Gravity 257257. Neutralisation No. (acidity) (mg KOH/gm) max. Moisture (max.) VISCOSITY Centistokes 100F. 2107. Saybolts as 1007. measured: 2107. "Absolute Saybolts" 1007. (SSU x Density) 2107. Pour Point Compressibility x 10-* sq. in./lb. Maximum Exit Air Temperature Boiling Point 7. at 760 mm Hg. Coefficient of Thermal Expansion per 7. Specific Heat (BTU/lb./7.) ( 777.) Thermal Conductivity BTU/hr./ft/7. --Vanor Pressure Hp fa7007:---- -- Bulk Modulus /Room Temp.\ ( 1000-6000 ) V psi / Surface Tension Dynes/cm 25C. Solubility in Water COMPATIBILITY WITH METALS PYDRAUL 625A Cl e<;r Gtotnty Blue Liquid i a,, 0, Sc 0.15% , PYDRAUL AC-A PYDRAUL AC-/\ WINTER GRADE 28 Clear Blue Liquid 0.15 0.15% Clear Blue Liquid i 0.15 0.15% . 125 to 145 - fezsr. * 62WSSU 4^ 4^9 SSU *iCi -845 SSU ui' 69 SSU *ic*e +307. 2.. so *" 206 y, ZO 44.6to5:0 41+ 408.6-SSU Hbi 4HSSU 4* 550 SSU tC -soSSU +207r 2,5c -&66 26 to 30 3.9 m.ss 432.5-SSU 3 3 380 SSU v li< -WO SSU *4.' 62 SSU l sv. 2,1. s- 3507. .3507. 3507. -7247. -688*fr S,Cf. 688`f- 0. CC4 > *0v00040" 0.00040- O.crv^-i 000040 c.lo* -078 0. 5) * -0:32- &32 C,C(*L* *6.065 -0066 O, ces* 6.066 ______ 0.09mm---------- ------------ 2.0x10-* ---------- ---------- 2.0x10*--------- -375,000 4 CO, vOC 40.2 Negligible -375,600 *tcr,ec'C 45.0 Negligible 875,000- 41.0 Negligible Tr>c1\<.\ Pydraul air compressor lubricants are compatible with all con struction metals including aluminum. In most operations, alu minum bearing surfaces that have been anodized will wear as long as any other metal bearing lubricated with Pydraul lubri cants. 006(1546 TOWOLDMONOQ56764 TOWOLDMONOQ56765 TOWOLDMONOQ56766 VISCOSITY, SAYBOLT UNIVERSAL SECONDS VISCOSITY, SAYBOLT UNIVERSAL SECONDS VISCOSITY, SAYBOLT UNIVERSAL SECONOS VISCOSITY, SAYBOLT UNIVERSAL SECONDS 0068549 TEMPERATURE, DEGREES FAHRENHEIT I I TOWOLDMONOQ56767 visc o sity, s a y b o it u n iv e r s a l seconds VISCOSITY, SAYBOLT UNIVERSAL SECONDS TEMPERATURE, DEGREES FAHRENHEIT TOWOLDMONOQ56768 Pydraul Fire-Resistance Pydraul fire-resistant fluids and lubricants have worked in industry since 1951 providing many millions of machine hours of fire-free operation. Never during these hours of machine operation has a Pydraul fluid contributed to a flre-- and never since their introduction in 195^ has any Pydraul fire-resistant compressor lubricant caused a compressor fire or explosion. FIRE-RESISTANCE TESTS OF PYDRAUL AC-A, PYDRAUL AC-A WINTERGRADE AND PYDRAUL 625A TEST ' RESULTS High Pressure Spray Test AMS-3150C and Federal Test Method Std. 791* Test fluid sprayed at 1000 psi . through orifice, passing through flame of oxyacetylene torch, 6000F. Does not flash or ignite up to 3i feet from orifice. Atomized Spray Test (procedure used by Factory Mutual Engineering Division). Test fluid heated to 1^0F. sprayed at 1000 psi from - atomized cone type nozzle. A torch is passed through this spray 2 feet and 2 to inches from the orifice 'b Hot Manifold Test (Federal Test Method Std. 791). Test fluid dripped on tube at 1300 F. Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200F., to test for spontaneous ignition Local burning by torch at 6 inches and 2 feet from orifice. Flames selfextinquishes immediately when torch removed. Does not flash or burn. Doesl^not Ignite. TOWOLDMONOQ56769 1' ) i I . ! i . . . . . PYDRAUL AC 4 Virtually Eliminates Valve Deposits Compressor Data: 142 CFM, 6" LP Bore, 5" HP Bore, 5" Stroke, 870 RPM, 100 psi air I 6 The photos compare exhaust valve deposits formed during individual 500-hour operations on two lubri cants: a premium grade petroleum oil . . . and Pydraul A OA *. A glance at the photo of the valve lubricated with petroleum oil shows considerable carbon deposit build-up after 500 hours operation. The improve ment in the valve condition in the photo on the right is obvious--virtually no carbon deposits after^ A 500 hours operation with Pydraul 1 n the /'c particular case, the compressor operator expects to . get 7500 to 10,000 hours of service from Pydraul --AG-without shutting down--a 15- to 20-fold in crease in operating time without a shutdown. Re sult: substantial maintenance savings in time and money--and virtual elimination of the fuel source of most air compressor fires and explosions. No photographs available of Pydraul 625 and Pydraul AC Winter Grade 28, but results are at least identical. 6855* TOWOLDMONOQ56770 Converting To PYDRAUL Is Easy First, simply drain the petroleum oil and wipe the crankcase or lubricator. Thoroughly clean the exhaust valves and interstage equipment before filling the crankcase or lubricator with Pydraul. Pydraul will loosen carbonaceous deposits, varnishes and sludge. Unless these loosened deposits are cleaned from the system, they could clog pipelines and components, requiring additional downtime and production loss. Once the valves have been thoroughly cleaned of potentially dan gerous carbon deposits, Pydraul lubricants will keep them clean--and let compressors run longer between maintenance shutdowns. STANDARD CHECK FOR COMPRESSORS-Plastic separator bowls. Not all plastic separator bowls are suitable for Pydraul service. Certain plastics are "crazed" or Boftened when exposed to Pydraul. Bowls made of glass, brass, steel, and these plastics--polycarbon ate, polyethylene, or nylon--are recommended for use with Pydraul. If you have a question regarding the resistance of a particular plastic, Monsanto will be happy to advise you. Diaphragm valves. Pydraul lubricants have a sof tening effect on neoprene and buna N rubber diaphragms normally used for petroleum oil service. These diaphragms should be replaced with butyl rubber, KPR (ethylene propylene rubber), fluoroelastomer, silicone or other compatible elastomer materials resistant to Pydraul fluids. Diaphragm sheeting is available from'normal sources of supply. All diaphragms in unloading valves or downstream control valves should be replaced at the time of changeover. Diaphragms in valving downstream from separator systems or drying systems need not be replaced at changeover time, but should be changed on a preventative maintenance schedule as soon as practicable after operation on Pydraul is begun. For air compressors supplying air for instrumenta tion functions, mist eliminator systems are rec ommended to remove lubricant mists and moisture from air streams. A Monsanto development, a Brink mist eliminator is a particularly effective system, available from Monsanto in a series of low- cost mist eliminator systems to operate at all capacities. For information on a Brink series suitable for your compressor system, write to: Monsanto Engineering Sales Department 800 North Lindbergh Blvd. St. Louis, Mo. 63166 _--; fc^ Telephone: (314) 694-2286 * fa V_> (Joseph A. Brink) . SPECIAL CHECK FOR SPLASH-LUBRICATED COMPRESSORS Crankcase paint. Pydraul air compressor lubricants will soften and loosen some paints from crankcase interiors. These paint particles could block the lubri cant passages. For this reason, it is a good practice to remove paint from crankcase interiors before Pydraul is added to the system. Standard paint removers are adequate for removing this paint. SPECIAL CHECK FOR FORCE-FEED LUBRICATORS Sight-glass fluid. If a separate force-feed lubri cator of the type normally filled with water and glycerine is used, one of two changes is necessary: either replace the sight-glass fluid with one heavier than Pydraul or insert a metal bobber in the sightglass. Pydraul fluids are heavier than water or glycerine and will not rise through these standard sight-glass liquids. Fluorochemical 101, a clear liquid supplied by the Minnesota Mining and Manu facturing Company, has a higher density than Pydraul and is a completely satisfactory replace ment. Metal bobbers. The alternate to using Fluoro chemical 101 is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, remov ing the guide wire and inserting the bobber. Opera tion of the lubricator is then indicated by movement of the bobber with each stroke of the pump plunger instead of counting the drops as with guide wires. Bobbers are available for either McCord, Manzell, or Lincoln Engineering lubricators. Modification of the Madison-Kipp lubricator requires replacement of the entire sight-glass. Vacuum-sight lubricators. Vacuum-sight lubrica tors require no modification for Pydraul usage. O0b*** 7 TOWOLDMONOQ56771 f/uRAUL Proyides N e Lubricating Qualities rs of service in air compressors of almost >e have proved the lubricating qualities of Sair compressor lubricants equivalent to premium petroleum oil. / ire the statements below from Engineers the performance of Pydraul as a4ubricant. "Lubricating properties of Pydraul AC have been very satisfactory. Wehr measurements on Moly- pak rings taken approximately five months later indicate 0.003" wear. This is normal and con sidered very good. No comssion of cylinder liners, valves and piping has/been experienced, and service is very satisfacrory."\ "Pydraul AC-tsutside of reducing the firehazard --also provid/s very satisfactory lubricatiorv and protection of/valves ... It seems rather logical to assume theft the complete absence of deposits due to progressive oil oxidation and consequent high temperatures, shall help improve valve per\ formande and maintenance. The higher gravity of Pydraul seems to result in better mechanical separation, and its water-like permanent clean liness does not interfere with the cleanliness of surfaces contacted." Compressor equipment: Joy Manufacturing WN-112-E TOWOLDMONOQ56772 PYDRAUL Provides ^xc^iUvdf $We Lubricating Qualities TABLE 3 RLWbSTSENGTH FALEx LoT> TBS.T PftSVtOfe Le.90 MW*fcOA0*(LB$.) VoRQUE / (LB& INCHES) Pydraul 625A Pydraul AC-ft Pydraul AC* A Winter Grade 28 4440- A36n9Q? \/ A / 92 \ TABLE 6 SHELL FOUR-BALL WEAR (167F., 1 hour, 630 rpm., mm scar diameter) STEEL ON STEEL PYDRAUL 625* PYDRAUL AO 1 PYDRAUL AC A WINTER GRADE 28 10 kg 40 kg c.* Qr2 m 0.1* 0702 o.tn C ,c(Z 8r30 0. 0r65 5TCrc 0, ^11 0. HS -- 0, TpAu0Ii;B|YlLIPET7ESJ* (Vickers V-lOSf;E., 140#F,, 1000 $, grams (Ibss or gain) . grams (toss or gain) j Bussing 201&krams (loss/or g4i Busl\ing 201$ grams (losi or gai TABLE 4 WEAR-UNDER-eOMTiNUOUS-LOAD FAUEk lOEA^- TtS.T ..-1*1 iIVa WltiWmiUiTi Er.cO , id 10 MJNUTCS Loik O'u.tos $ g|.QCU - Pydraul 625A Pydraul AC * ft Pydraul AC- A Winter Grade 28 M 1 -0.00001-80000428 0 , <o 0 0004^0 S-.S -8:000332' 0,S ereeo^so- 0.9 0000968 tly av^lable oij Pydpul DROP SIZE 0068855 Drop size of a lubricant is important to determine an adequate lubricant injection rate to insure proper compressor lubrication. The rate of lubri- j cation is controlled by noting the drops per unit j TABLE 5 of time. TIMKEN <X*ftME-PKESSUKE)* The drop size for the fluids tabulated below were | O K t- ongCiu.)Pinn STZfip&i|)(^.)rietermined by noting the number of drops formed Pydraul 625A Pydraul AC * A Pydraul AC-/\ 3o Bt^OOirei ^ $ 20rO60-psi 2.^. lOO08T>sl itT,>oo $ (cOO at room temperature (75F.) on a 1 mm I.D. by 3'/2 mm O.D. glass tip. (Larger or smaller drops j will result if different sized tips are used.) Winter Grade 28 Drops per cubic centimeter /W Ft\.eng)f\Typ>fcVj Petroleum/Oil (measured b/Thwlisn txtrMie rVsurey-51oGO/toXDOO psK----7 Medium weight petroleum oil Pydraul AC 33 39 When installing new equipment, it is best to start with an increased lubricant feed rate and reduce this rate by successive increments. Inspection of cylinder walls and valves will indicate the proper degree of wetting. TOWOLDMONOQ56773 PYDRAUL Is Used As A Lubricant For Air Compressors Made By Ali Major Manufacturers New air compressors of most types and sizes pro duced by major compressor manufacturers can be manufactured for lubrication with Pydraul. The manufacturers listed (right)have manufactured com pressors equipped for Pydraul, upon specification of the buyer, for over ten years. Many compressors have operated on Pydraul lubricants continually with exhaust air temperatures of 350F. Pydraul is also used to lubricate cylinders in compressors operating at pressures over 4500 psig. Mixing Compatibility Pydraul AC~A, Pydraul AC-A Wlntergrade 28 and Pydraul 625A are completely miscible in all proportions with competitive synthetic lubricants such as Fyrquel* 150, 220, 300, 500 and Houghto-Safe** 1010, 1120 and 1130. Registered trademark of Stauffer Chemical Company Registered trademark of E. F. Houghton Co. 150 \ YE^/ YES YES 220 VA'K YES YES 300 , Aes YES YES 550 y/ YeV YES YES 10 0066556 I TOWOLDMONOQ56774 0V- American Messer Corporation Bury Compressor Company Carrier Corporation Chicago Pneumatic Tool Company Clark Brothers Company, division of Dresser Industries Cooper-Bessemer Corporation DeLaval Steam Turbine Company Gardner-Denver Company Ingersoll-Rand Company Joy Manufacturing Company Kinney Manufacturing, division of The New York Air Brake Company Norwalk Company, Incorporated Schramm, Incorporated Worthington Corporation TOWOLDMONOQ56775 Safe Handling There has been no reported case in many years of service to indicate any special health hazard with Pydraul air compressor lubricants. However, as with all specialized Industrial fluids and lubricants, certain precautions are advisable. Animal toxicity screening studies indicate Pydraul AC-A, Pydraul AC-A Wintergrade 28 and Pydraul 625A may be considered only slighly toxic from the standpoint of accidental ingestion or skin absorption. It does not appear to have any significant potential for skin or eye irritation. Because these fluids have excellent solvent properties repeated or prolonged skin contact could lead to de-fatting and drying of the skin; thus reasonable personal hygiene practices are recommended to avoid prolonged and repeated skin exposure. If Pydraul fluids are splashed or sprayed into the eyes, moderately severe pain and irritation may result. There is no evidence to show Pydraul causes permanent eye tissue damage. Eyes should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physicians have used 1% pontocaine solution, as well as the ophthalmic cortisone acetate solution. Vapor inhalation. At room temperatures, there is no vapor inhalation hazard from Pydraul fluids. Although there has been no problem with high concentrations of vapors, inhalation of vapors at high temperatures should be prevented. If the compressed air is to be used for air line masks, respirators and other Inhalation equipment, it is always recommended that a commercial filter cartridge for air-supplied masks be Incorporated in the compressor air line to remove any foreign matter. This is good industrial practice for any compressor fluid or lubricant. 0068558 TOWOLDMONOQ56776