r" ' 11 v/! INTERNAL CORRESPONDENCE CHEiVilCALS AND PLASTICS P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 To (Name) Division Location Copy to Mr. J. W. Biddle Mr. C. W. Carman Mr. G. F. Hurley/ Mr. L. R. Noblev Mr. D. Paugh Mr. C. E. Richardson Dal- June 2, 1977 O'S "Ccg Dec. IH/EP ^b,ect Asbestos Insulation INTRODUCTION We were notified that asbestos insulation would be stripped from the dust collector on #2 boiler at the Institute Plant. DISCUSSION The area around the dust collector was isolated by ropes and warning signs were visable. Water was used to help control dust. The 3M disposable dust mask was used by all employees in the controlled area. Air samples were taken to evaluate levels of asbestos dust in the air. RESULTS DATE NAME 5/26/77 -- 5/26/77 -- 5/26/77 Day TIME AREA CONCENTRATION FIBERS/CC 0845-0900 Area Sample1''"' 5 * Upwind, ^"6' High .05 0902-1035 Area Sample^5* Downwind, 6 * High .63 0935-1035 Personal Sample Scaffold-Stripping Insulation 2.44 UCC 016679 2 6/2/77 DATE NAME 5/26/77 Hall 5/26/77 TIME AREA CONCENTRATION FIBERS/CC 0935-1035 Personal Sample Scaffold-Stripping Insulation 1.78 1040-1102 Area Sample^SO* Upwind 3' High .06 CONCLUSIONS One sample exceeded the Threshold Limit Value of two fibers/cc by a small amount. In some areas the employees were lax in us ing water to wet the insulation. Better control could have been achieved if more water was applied. Several of the employees were not wearing the respiratory protection properly. In the use of the 3M mask, a proper face seal is essential. Both straps of the mask must be used and they must be properly positioned on the back of the head. The principles of the masks use covered in the training sessions must be applied in the field to assure adequate protection. METHOD Samples were counted in accordance with the NIOSH Method for Sampling Evaluation of Airborne Asbestos Dust. Please contact us if we can provide any additional assistance. JPG/mar UCC 016680 H'| t 5' ii!|: INTERNAL CORRESPONDENCE CHEMICALS AND PLASTICS P. C. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 To (Name) Division location Ccp^ to Mr. J. W. Biddle Mr. C. w. Carman Mr. G. F. Hurley Mr. L. R. Noble Mr. D. Paugh Mr. C. E. Richardson \ D*ltf June 2, 1977 O- g r 9 Dcp, IH/EP s wc- Asbestos Insulation INTRODUCTION We were notified that asbestos insulation would be stripped from the dust collector on #2 boiler at the Institute Plant. DISCUSSION The area around the dust collector was isolated by ropes and warning signs were visable. Water was used to help control dust. The 3M disposable dust mask was used by all employees in ' the controlled area. Air samples were taken to evaluate levels of asbestos dust in the air. RESULTS DATE NAME 5/26/77 -- 5/26/77 -- 5/26/77 Day TIME AREA CONCENTRATION FIBERS/CC 0845-0900 Area Sample^ 5' Upwind, ^*6' High .05 0902-1035 Area Samplers' Downwind, 0 t High .63 0935-1035 Personal Sample Scaffold-Stripping Insulation 2.44 UCC 016681 2 6/2/77 DATE NAME 5/26/77 Hall 5/26/77 -- TIME AREA CONCENTRATION FIBERS/CC 0935-1035 Personal Sample Scaffold-Stripping Insulation 1.78 1040-1102 Area Sample^50' Upwind, 3' High .06 CONCLUSIONS One sample exceeded the Threshold Limit Value of two fibers/cc by a small amount. In some areas the employees were lax in us ing water to wet the insulation. Better control could have been achieved if more water was applied. Several of the employees were not wearing the respiratory protection properly. In the use of the 3M mask, a proper face seal is essential. Both straps of the mask must be used and they must be properly positioned on the back of the head. The principles of the masks use covered in the training sessions must be applied in the field to assure adequate protection. . METHOD Samples were counted in accordance with the NIOSH Method for Sampling Evaluation of Airborne Asbestos Dust. Please contact us if we can provide any additional assistance. JPG/mar UCC 016682 VINTERNAL CORRESPONDENCE -- Mt(Z) :hemicals AND PLASTICS o (Name) ivijion ocation '.opy to Mr. A. S. Howard Mr. D. R. Paugh Mr. H. L. Reveal Mr. E. C. Shipley Mr. J. W. Biddle Mr. C. W. Carman Mr. G. F. Hurley Mr. L. R. Noble ' Mr. F. Williams P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 Date August 25, 1977 Originating > IH/EP Subject Asbestos Monitoring at Institute Gentlemen: On August 15, 1977, air samples were taken during the removal of insulation possibly containing asbestos from the breech work at the powerhouse at Institute. Two insulators wore personal sam pling pumps during the operation. Also, an area sample was taken twenty feet downwind from the job. The area sample indicated a concentration of 0.48 fibers/cubic centimeters while the personal samples indicated concentrations of 2.59 and 2.61 fibers/cubic centimeter. These concentrations are higher than the current OSHA eight-hour, time-weighted average of two fibers/cubic centimeter of air. Therefore, respiratory protective equipment must be worn in the area. Several workers were not wearing respirators at the time the samples were taken. Although water hoses were used to wet the insulation before and during removal, some insulators were working ahead of the water hoses and stirring up clouds of dust. Wetting with water significantly reduces emission of airborne dust when properly used. The above air samples were sampled and analyzed by phasecontrast microscopy using Union Carbide Corporation, Chemicals and Plastics Industrial Hygiene Handbook Method Number 38C-29X4-Rla. This method is identical to the procedures used by NIOSH, the organization responsible for developing methods specified by OSHA. If we can provide additional assistance, please contact us. WFBJr/mac Attachment UCC 016683 DATE EMPLOYEE SAMPLING TIME (MINUTES) 08/15/77' R. P. Williams 1032 - 1115 (43) 08/15/77 W. G. Adkins 1033 - 1115 (42) 08/15/77 Area Sample 1045 - 1118 (33) CONCENTRATION FIBERS/CC 2.59 2.61 0.48 TWA FIBERS/CC 2.59 2.61 ------- UCC 016684 I INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX 8361, SOUTH CHARLESTON, WV 253C3 Tc INti" e; W. L. Browning = -5 0-- J. W. Perry, Jr. --institute Plant cte October 23, 1981 Q S IH/EP C. W. Carman * M. L. Mills ' L. R. Noble D. R. Paugh R. E. Peele H. H. Frazier R. J. Sexton, M.D. F. Williams ________ Asbestos Monitoring in Gasket Shop, 512 Construction Gentlemen: In my letter of October 20, 1981, concerning asbestos monitor ing in the Gasket Shop - 512 Construction, an error was made due to misinterpretation of the data we received from the 512 Industrial Hygiene group. Please replace the letter dated October 20, 1981 from your file with the one attached to this note. Very truly yours, MAP/sc Attachment Manhar A. Patel UCC 016685 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.D. BOX 8361, SOUTH CHARLESTON. WV 25303 t= irjare) an W. L. Browning j. w. Perry, Jr Institute Plant a-e October 23, 1981 O-wneot IH/EP C. W. Carman M. L. Mills L. R. Noble D. R. Paugh R. E. Peele H. H. Frazier R. J. Sexton, M.D. F. Williams Asbestos Monitoring in Gasket Shop, 512 Construction (Replaces letter of October 20, 1981 - front page only.) Gentlemen: Attached are the results of the area and personal exposure monitoring done for asbestos in the Gasket Shop - laundry, Building 3 of the Construction Department, Institute Plant. This monitoring was done by the Institute Plant Industrial Hygiene group on October and 9, 1981. 2, The gasket cutting is done infrequently and it would generally last for a short period of time. The results of the survey indicate that the asbestos exposure in excess of the permissible limit of 2 fibers per centimeter cube of air did not occur. The workers did not wear a respiratory protective device while working with the gasket material. It is emphasized that all workers wear a disposable 3M #8710 dust respirator which is approved by NIOSH for protection from asbestos exposure. Please notify the monitored workers of their exposure results. If I can be of further assistance, please give me a call at extension 3750. Very truly yours, ri--X-PjJ. Manhar A. Patel MAP/sc Attachment UCC 016686 SINESS ONFIDENTiAl j ASBESTOS MONITORING CONSTRUCTION GASKET SHOP INSTITUTE PLANT Name/Area Monitored F. M. Hatfield 3 Feet from cutting blade F. M. Hatfield 3 Feet from cutting blade Date Sampling Time Minutes Asbestos Cone. Fibers >5 um/cm^ 10/2/81 18 < 0.1 10/2/81 17 < 0.1 10/9/81 10/9/81 15 15 0.4 0.2 UCC 016687 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P O BOX 336 1 . SOUTH CHARLESTON, WV 25303 R. C. Proffitt 511-2009 512 M. E. Bell C. W. Max-well M. L. Mills L. R. Noble D. R. Paugh R. E. Peele A. L. Postlethwait W. F. Williams Date June 21, 1983 cr:g,natDear; 522 Industrial Hygiene/ Environmental Protection Asbestos Monitoring in Storeroom, 511 Construction Department Dear Mr. Proffitt: On May 9, 1983, the Technical Center Industrial Hygiene group conducted a monitoring survey for determining the exposure of employees to asbestos dust particles while handling asbestos containing gaskets in the storeroom at the 512 Construction Department. This work was done by M. E. Bell of our group. Mr. J. H. White was monitored for asbestos exposure when he received one hundred asbestos spiral-wound gaskets in three bundles. During the monitoring period, Mr. White removed these gaskets from the box, counted and placed them in a storage bin in the storeroom. Mr. White wore a dust respirator approved for asbestos while performing the job. In addition to the personal sample, an area sample was also collected. The results of monitoring shown in the attachment indicate that exposure to asbestos fibers above the permissible exposure limit of 2 fiber/cc are unlikely. It is our observation that while unpacking and placing gaskets in the bin the probability of exposure is minute; however, it is believed that once the gaskets are stored in the bin some dust will become loose due to friction and may build up over a period of time. We recommend that the gasket storage bin be cleaned once every month. The person cleaning the bin should wear a dust res pirator. The method of cleaning the bin should be wet. The easiest way would be to rinse the bin with water in the sink. Please notify Mr. White of his exposure results. If we can- - y. UCC 016688 R. C. Proffitt 2 06/21/83 be of further assistance, please call us at extension 3750. Very truly yours, MAP/sc Attachment Manhar A. Patel UCC 016689 ASBESTOS SAMPLING May 9, 1983 lUfINISI CONHDSNTIAL Name or Location 1. J. H. White 2. Area Sample Sampling Time (Mins) 10 9 Concentration Fibers/cc 0 < .07 The permissible exposure limit is 2 fibers > 5 pm/cc of air UCC 016689A INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX 036 1, SOUTH CHARLESTON. WV 2 o.^ei G> w> Phares I'VrS'O'-' J`'3',0n U3..e November 22, 1985 Ong.r^cjDen-. HS&EA Industrial Hygiene B. H. Avashia, M.D. J. H. Barna J. A. Byrd T. L. Collins W. V. Filipek C. P. Maxwell M. L. Mills Asbestos Monitoring at South Charleston Plant D. R. Paugh Attached are the results of asbestos exposure monitoring conducted on November 18, 1985 at the South Charleston polyols unit near Building 103. Construction employees stripped the insulation from a tank 13 feet in diameter and 30 feet tall. The stripping and bagging was done by eight men, four were monitored. One man was monitored at the base of the tank while receiving and removing the bags of asbestos as they were lowered from the scaffold. A spray of water was used to wet the insulation and minimize dust. The area was barricaded and well posted for the asbestos hazard. All nine employees wore disposable respirators, disposable head covers, disposable coveralls, boots and solvex gloves. The protective equipment was removed upon leaving the barricaded area and used new equipment upon returning. All samples were found to be well below the allowable exposure level of 2 fibers/cm^. This indicates that a good job is being done of controlling the amount of airborne dust by water spray, and bagging at the point of removal. Please notify all employees of their-exposure results. If we can be of further assistance, please contact us on extension 4779 or 3750. 0763P WORK BY; APPROVED Vance Stover A ^ Manhar A. Patel UCC 016690 ASBESTOS MONITORING AT SOUTH CHARLESTON PLANT Computer re fe re n c e W 1856 *o c H3 c o c: fO CJ)To- CD CD C 4-5 ec *-- fT3 r" Q. r-- r = z > CD CL 3 r-- JO X3 f-- to (D 1- c U s- o 4-5 f- to CD CD 4- S- 4-5 <4_ to CD O r-- 4--5 r- to to -c cd 4-5 2 -O c to ' 4- fC rC--D CO u CO r-- CO CD E fC o JD L- O) o *3 *a 4- E cd cu CD E L. CD &- C "O OOC o 4-> r- z z o r- CD 4-5 > S- i- CD c O CD C CD cE2 O <T5 o CD O ^ JC 2: S- r- ^^ u <o 2\ 1-- 00 LO 1 i- o i- cd zr _o o r-- CO LL. '' ^^ u o </> LO S- LO $- CJ 0) O 1- C -Q C O -r- o O LL. LO LO CD o CM r-- cm CM O oooo CM co CM CO r-- ro LO 00 r-- C\J CM o oooo * cn C 00 <D r"" 4--^ LO a Q) 3 EEC fO rco 1-- s c o >> r- CD 4-> r-- 3 o rC o Q_ --1 cd __ 1 E ro z or CO CM LO CO <3- CO d" S- oc r-- 4-5 CD 2 03 CD c o CD CD r-- s. 1-- CO C O 3 cu t o 1-- o LO CO a; CO 4-> r-- rc 1 o r-- r* LO LO in LO CO CO CO11 CO 00 00 CO CO r-- r-- p-- 11 1 r-- r-- p-- '-- -- r-- >-- UCC 016691 INTERNAL CORRESPONDENCE RECEIVED ov 2 5 1985 UNION CARBIDE CORPORATION TECHNICAL CENTER SAFETY DEFT, PQ. BOX S361, SOUTH CHARLESTON. WV 25303 G. W. Phares November 22, 1985 dent HS&EA Industrial Hygiene B. H. Avashia, M.D. J. H. Barna J. A. Byrd T. L. Collins W. V. Filipek C. P. Maxwell M. L. Mills--------- ^ L. R. Noble D. R. Paugh Asbestos Monitoring at South Charleston Plant <v Attached are the results of asbestos exposure monitoring conducted on November 18, 1985 at the South Charleston polyols unit near Building 103. Construction employees stripped the insulation from a tank 13 feet in diameter and 30 feet tall. The stripping and bagging was done by eight men, four were monitored. One man was monitorea at the base of the tank while receiving and removing the bags of asbestos as they were lowered from the scaffold. A spray of water was used to wet the insulation and minimize dust. The area was barricaded and well posted for the asbestos hazard. All nine employees wore disposable respirators, disposable head covers, disposable coveralls, boots and solvex gloves. The protective equipment was removed upon leaving the barricaded area and used new equipment upon returning. All samples were found to be well below the allowable exposure level of 2 fibers/cm^. This indicates that a good job is being done of controlling the amount of airborne dust by water spray, and bagging at the point of removal. Please notify all employees of their exposure results. If we can be of further assistance, please contact us on extension 4779 or 3750. 0763P WORK BY:___________________ Vance Stover APPROVED BY: A Manhar A. Patel UCC 016692 ASBESTOS MONITORING AT SOUTH CHARLESTON PLANT o c: ro c "O c 03 o CJ) *r-- CD CD C 4-> r- rd C r" rc-- CXr- r : r > <D CL 13 r- 00 r~ JO ID CL) i- cr *r- 00 O S- O CD a; 4-- S- 4-> 4- 00 4- f0 <D o r*" +-> r~ 00 - CD CO u to to to -C CD .C CD E 5 -O c to CO o -Q S- cd "O ITS TO 4-- is c O) S- CD CD CD s. C "O o oc o r- a> o 4-> -rr- CD : z : 4-> > Sr-- O CD C CD CE5 O 03 o CD O ^ -Q s: S- r- u < 3: u r-- h- m in i s- u a> o nr _o o CO U- ou to LO S- LT> S- U CD o C -O Oo *Lru- o LO lo CD r-^ o r--* CNJ cnj C\J O oooO CNJ co CNJ ro r-- co ID CO r-- CNJ CNJ o oooo CD c to CD r-- 4-) LD CL CD 3 <3E E C *3" ro LO J-- c O >> t-- (D 4-> r-- rO 3 O ro o Q. _! CD -J E rd 2S or 00 CNJ LD co CO *3- *3" s- o r-- 4-> rO CD CD CD Z \-- c CD 2 Co SCO 9 < o 3 or '"O 1-- o LO CO i CD CO 4-> r-- rO 1 O r-- -- LO LO LO LO 00 CO CO 00 1111 CO 00 CO CO f--* 11 1 r** n-- -- r-- p-- *-- LD LO CO r- 3: <D u c QJ S- CD 4CD J- S- 0) -M 3 Q_ CL C co LD O r^ oo UCC 016693