Document qkd2xonRGegg3dxrrwJnr38Kx
850
CHAPTER 33
1958 Guide
velocity of the air entering the effective face area of the cleaner and may be expressed by the equation:
where
V -- face velocity, feet per minute Q .= airflow, cubic feet per minute A effective face area, square feet
.Effective face area is further defined as that area of the filter face inside the enclosing frame, flanges, or seals, but not corrected for any area occupied by any bracing, and retaining or strengthening grid members, located within the enclosing frame.
The rated capacity of general ventilation filters is often based on face velocities in the range of 250 to 520 fpm. Resistance to air flow, measured
Air Cleaning
851'
of test dust that is used and in,the method of measuring the dust .content, of the entering and leaving air. The numerical value of . the arrestance or efficiency of an air cleaner may be different for different methods of test even when the same test dust is used, and is generally different for different, test dusts using the same test method., Caution is to be exercised in interpreting published air filter arrestance data, since the test efficiency may be different from that obtained in an actual installation, or in the space being supplied with air.
The two most common methods for evaluating efficiency,are: (1) the weight method, in which the weight concentration of dust in the air enter ing and leaving the filter is measured by some suitable means, and (2) the dust spot test in which the dust content of the entering and leaving air, is measured .in terms of its ability to stain filter paper. : The particle, count method is not used for efficiency evaluation, except in investigation of filter.
Fio. 3. Resistance to Air Flow of Four Unit Air Filters
in inches of water column, at rated capacity, is generally available from the manufacturer (see Catalog Data Section). A suitable allowance must be made in the system design for increase in resistance as the filter becomes loaded with dust. Fig. 3 indicates the range of resistance to air flow found on tests of four unit filters. Type A is a dense pack used in bactenum control; Type B is a medium pack used for general ventilation work; Type C is a low resistance unit, for use where low resistance is the important factor and maximum cleaning efficiencies are not essential; and Type D is a high-velocity viscous-impingement filter.
The effectiveness of air cleaners in removing a given dust from the air is called efficiency or arrestance. If the efficiency is denoted by E, then algebraically E is given by:
E = (2)
where
Di = amount of dust per unit volume in uncleaned air. >j = amount of dust per unit volume in cleaned air.
A number of procedures for evaluating air cleaner efficiency have been proposed and are in use. These procedures differ principally in the type
Fig. 4. Dust and Lint Holding Capacity of Two Filters
performance on specific particles such as pollen, or on certain industrial
usts harmful to health. Dust particles can be captured on microscope
slides by means of one of the various kinds of impingement devices. The process is useful if inspection and analysis of dust are desired, but particle
counting is not sufficiently precise for evaluating the efficiency of a cleaner operating on a heterogeneous dust.
. Among the weight methods that have been used are the Air Filter Insti-
W a ,and modifications of the former ASHVE Code7. By the latter
tetSfii ' a known weight of a prepared dust is injected into air supplied estr and the <luantity of dust in the cleaned air is determined by Dmt -i?8 and weighing the dust from a known volume of cleaned air. Jr extraction from the air is accomplished by drawing the air through a
emcible or thimble by means of a high vacuum. The test dust Th ed m the AHVE Code is a mixture of coal ash and carbon black,
q. A}r FiUer Institute Code, Section I, specifies a test dust mixture of
ASHVPrv^ Air leaner Test Dust-fine, carbon black, and lint. T.i'ke the
known
the enterin8 concentration (A) is determined by feeding a
n Weight of the prepared test dust. The concentration of dust in the