Document qkZdM374qVd4ODbbqyeLZZnVj
FRICTION MATERIALS STANDARDS INSTITUTE, INC., -210 ROUTE ,74,
w. u.
BULLETIN
NO. 4 4 6
July 11, 1972
TO: ALL MEMBERS
SUBJECT: EQUIPMENT/TRA J NING FOR^ASBESTOS MEASUREMENTS
At the recent Annual Membership Meeting it was brought to my attent on that many members had not received information on equipment for measuring airborne asbestos in the work place. Most of the following information is a re-hash of earlier information - partic ular.y Bulletin #428 of February 18, 1972.
0S:A STANDARDS. OTHER PAPERS REL*T>VF TQ ASBESTOS IN THE WORK PLACE
1. Occupational Safety Health Administration (OSHA) Standards per Williams - Steiger OSHA Act of 1970. -Federal Register, May 29, 1971
2. OSHA Standards for Exposure to Asbestos IX/st, Federal Register, vAine 7, 1972
3. "Measurement of Airborne Asbestos Fiber by the Membrane Filter Method". Asbestos Textile Institute P.0. Box 239 Pompton Lakes, New Jersey 07442
- {Price Ol.OO/copy)
The Institute distributed copies of these to the members during the past year. The most pertinent are Item 2 (OSHA Standards for Asbestos) and Item 3 (Measurement of Airborne Asbestos...").
GENERAL METHOD (MEMBRANE FILTER METHOD)
A pick-up is worn by a worker in the area to be measured. A battery operated vacuum pump draws in air over a specified period--say 60 minutes, 90 minutes or four hours. Asbestos fiber is trapped by the filter and then sealed and sent to the laboratory. The sample is examined using an optical microscope where asbestos fibers are counted.
Details on the optical count are given in the book "Measurement of Airborne Asbestos Fiber by the Membrane Filter Method".
\
Bulletin ;.-446
-2- July-11, -1972
EQUIPMENT & SUPPLIES
Depending on the size of operation, at least two oumos costing about $150 each are required:
(a) Mine Safety Appliance Co., Pittsburgh, Pa. 15208
(b) Willson Products Div., Reading, Pa. 19603 (c) Unico Environmental Instruments, Fall River, Mass.
02720
A battery charger (one for each 2 pumps) is suggested. The charger would coit about $50.
Pad and filter inserted run about 70 a piece, and are available from the Willipore-Corporation, Bedford, Mass., 01730.
A tinocular microscope with phase contrast illumination set for
400/430X magnification is required. IVhile a Bausch & Lomb microscope
costing $1,200/1,500 is basic, binocular microcopes with additional fix
tures should be worth the additional cost. (Seek professional advice on
this.)
-
-
Most of the above information is verbatim from the book "Measurement of Airborne Asbestos Fiber by the Membrane Filter Method."
OUTSIDE SERVICES AND TRAINING
It may be feasible to have outsiders do the full job - from sampling through examination and reporting. Others will do the analysis work only
where the samples are mailed to the laboratories.
Tracerlabs in California will do analysis work for about $50.-60. per analysis.
Johns-Vanvilie will do the full job for a fee (Contact Mr. W. Reitze, Manager Industrial Hygiene Engineering Service, Johns-Manville Corporation, P.0, Box ,"5108, Denver, Colorado 0217)
George Clayton Labs, Southfield, Michigan will do the full job for
'a fee.
'
There are other labs that may do the entire package or the analysis work cnly.
Johns-Vanvi11e indicated it would be willing to train personnel in the technique in a two day period. They would take one trainee or at most tv;c trainees, to one instructor for $200. a day. These sessions .would be at rhinaern (Somerville) New Jersey or Waukhegan, Illinois. Again, the contact would be with Mr. Reitze in Denver.
It is most important that those concerned with the OSHA Standards enforcement receive this basic information. Should additional informa tion be required, please advise.
E. \`l. Drislane Executive Director