Document qkMNwbDo174Dd7B08vGvd9Kwj

Paoli, Pennsylvania March 23, 1965 To: All Regional Sales Managers All Area Sales Managers All Salesmen Cc: Mr. R.I. Fredericks Mr. K.A. McCaskill Paoli Paoli General Sales Bulletin #20-65 Subject: 5/8" THICK BESTWALL FIRESTOP Re: Southern Building Code Congro Report #63UU By: G.C. Moore /ghp File - Wallboard Manual Section 10 Attached are two (2) copies of the subject Committee on Compliance Approval Report dated October 10, 1963. This is a reissue of a previous Report #6280. You will note that this Report has dropped the Underwriters' Retardant Report ^R2717-23 and the following have been included, 1) Floor and Cdiling Construction, Report 4R2717-26 or UL Design #13 for 1- Hours. 2) Under Floor and Ceiling Construction, Report #R2717~27 or UL Design #69 for 2 Hours, 3) Partition System using 5/8" Firestop vinyl clad with the Neslo "Z" stud, covered under Report #T-2lj06 for 2 Hours. Destroy the old Approval Report #6280. Additional copies of this sheet are available upon request. The Official Test Reports are available when Building Officials require them for their approval and record. PLAINTIFF'S EXHIBIT GP-806 SGP 0025285 COMMITTEE MYRON i. SASSER. Chm. L. P. HAMILTON THOMAS M. MOSES BROWN-MARX BUILDING BIRMINGHAM, ALABAMA REPORT: 6344 APPROVED: 10-10-63 EXPIRES: COMMITTEE on COMPLIANCE APPROVAL ON %" THICK BESTWALL FIRESTOP MANUFACTURED BY BESTWALL GYPSUM COMPANY SOLD THROUGH BESTWALL CERTAIN-TEED SALES CORPORATION ARDMORE, PENNSYLVANIA REPORT The Manufacturer made formal application on July 19, 1963, for re-evaluation of their Approval Report No. 6280, dated December 28, 1962, requesting that Underwriters Re tardant report 2717-23 be removed from the Report and that Unde, writers Retardant reports number R 2717-26, R 271727 and Ohio State University report number T 2406 be in cluded in this Approval Report. THIS APPROVAL REPORT SUPERSEDES AND TAKES PRECEDENCE OVER REPORT DATED FEB RUARY 6, 1959, AND REPORT 6280 DATED DECEMBER 28, 1962, THEREBY REMOVING AND MAKING IN VALID THE APPROVAL REPORT AS DATED FEBRU ARY 6, 1959, AND REPORT 6280 AS DATED DECEM BER 28, 1962. The Committee on Compliance has reviewed the data submitted on August 11, 1958, together with new test re ports submitted on July 19, 1963, for compliance with the Southern Standard Building Code and submits its Report as follows: DESCRIPTION: Bestwall Firestop is a gypsum wallboard having a spe cial core formulation under a patented process in which in combustible glass fibers and unexpanded vermiculitc have been added to the gypsum core. It is manufactured in M" and %'' thicknes s. Firestop is made generally in 4 ft. wide sheets with t; )ered edges and a finished wall or ceiling includes the convt tional tape and cement joint system. It is also ava'lable \ h a square edge or tongue and grooved edges and also in ft. and 4 ft. widths for use as an un finished fire ratet assembly as a garage wall or a backup for further treatment as acoustical tile, etc. USES: Wall, floor and ceiling assemblies, for load bearing and non-load bearing with fire retardant properties. Framing consists of metal or wood studs, bar joist or wood joist for load bearing and non-load bearing assemblies and no frames for non-load bearing partitions. SUBSTANTIATING DATA: 1. Manufacturers literature. (a) Sweet's insert 1963--Bestwall Gypsum Wallboard --Form BW-62250. (b) Fire Resistive Ratings--Bestwall Firestop--Form BW-62465. 2. Copies of Official Fire Test Reports made under ASTM E 119. Underwriter Retardant 2889 Underwriter Retardant Underwriter Retardant 2717-7-8 3843 2717 Underwriter Retardant 2717-16 Underwriter Retardant 2717-19-21 Underwriter Retardant 2717-20-22 Underwriters Retardant 2717-26 Underwriters Retardant 2717-27 Ohio State Experimental Station Report T-209 Ohio State Experimental Station Report T-194 Ohio State Experimental Station Report T-2406--January 1963 Underwriters Letter Report July 20, 1962 8/5/47 7/12/51 12/27/55 12/1/52 6/3/57 8/26/57 3/27/63 4/22/63 Loadbe- ring Partition Wood studs 1 hr. Floor a id Ceiling Wood joist & floor 1 hr. N.n-Load Bearing Partition Metal studs 1 hr. Floor a: I Ceiling Steel Bar Joists 1 hr. Non-Load Bearing Wall Semi- Solid Hummer "B" I hr. Non-Load Bearing Wall Semi-Solid Modified 2 hr. 3 hr. Floor and Ceiling Steel Bar Joist 1M> hr. Floor and Ceiling Steel Bar Joists 2 hr. Load Bearing Wall Metal studs I hr. Load Bear ing Wall Wood studs 2 hr. Non-Load Bearing Wall Metal studs 2 hr. Tape and cement not required for fire resistive ratings. SGP 0025286 REFERENCES TO SOUTHERN STANDARD BUILDING CODE: Chapter X--Fire Resistance Rating for Materials and Construction. IDENTIFICATION: Bestwall Firestop is shipped twin mounted (2 boards face to face) and an end bundling tape with the U. L. Mani fest (label) on each end. All Bestwall Firestop sheets shall carry a face marking in the center of the board, repeated every five feet (or %") Bestwall Firestop Type "X". COMMITTEE FINDINGS: The Committee on Compliance in review of the data sub mitted finds that, in their opinion. %" thick Bestwall Fire stop Constructions meet the provL.ons of the Southern Stand ard Building Code as follows: (A) --%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code v here 1 hour fire resistance, load bearing or non >ad bearing, combustible or incombustible wall id partition or floor and ceiling construction h required. (B) --%" Bestwall Firesto in multiple layer (2 layer) application in the co itruction as detailed in the fire test reports ir. 'ets the provisions in the Southern Standard Building Code whore 2 hour fire resistive walls and partitions, load-bearing or non-load bearing, combustible or incombustible is required. (C)--%" Bestwall Firestop in multiple layer applica tion in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 3 hours non-load bearing fire resistive walls and partitions are required. (D) --%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where lVz and 2 hour fire re sistive floor and ceiling incombustible construc tion is required. (E)--In view of the Fire Hazard Classification show ing a 10 to 15 Flame Spread Rating, %" Bestwall Firestop shall not be limited under the South ern Standard Building Code other than as above in A, B, C and D. (F)--Height of non-load bearing frameless partition shall be limited to 12 ft. Maximum height of frame partitions shall be governed by rules on frame material (including section) used. (G)--Joints may be taped or untaped depending on the erectors desires since the taping of joints has no effect on the retardant ratings. COMMITTEE RECOMMENDATIONS: The Committee recommends that %" thick Bestwall Firestop uses and limitations as set forth in this Report be approved by the Southern Building Code Congress. LIMITATIONS: That Bestwall Firestop shall be made under Under writers Inspection Service, listed by Underwriters Labora tories and carry the U. L. Manifest on the end bundling tape. PERIOD OF APPROVAL: This Approval or Certificate of Compliance will be in effect as long as the product "Bestwall Firestop" is listed by Underwriters Laboratories and manufactured under Under writers' Inspection Service. Should any revision or changes of method of construction occur, this Approval shall terminate. This, however, is not to be construed to preclude any new submittals. L. P. Hamilton, Columbia, South Carolina ^o^m^MT^oses^Vinter Park, Florida SGP 0025287 COMMITTEE MYRON J. SASSER, Chm. L. P. HAMILTON THOMAS M. MOSES BROWN-MARX BUILDING BIRMINGHAM, ALABAMA REPORT: 6344 APPROVED: 10-10-63 EXPIRES: COMMITTEE on COMPLIANCE APPROVAL ON s/8" THICK BESTWALL FIRESTOP MANUFACTURED BY BESTWALL GYPSUM COMPANY SOLD THROUGH BESTWALL CERTAIN-TEED SALES CORPORATION ARDMORE, PENNSYLVANIA REPORT The Manufacturer m. ie formal application on July 19, 1963, for re-evaluation of their Approval Report No. 6280, dated December 28, 1962, 'equesting that Underwriters Re tardant report 2717-23 bo emoved from the Report and that Underwriters Retardant r.ports number R 2717-26, R 271727 and Ohio State Unive sity report number T 2406 be in cluded in this Approval Report. THIS APPROVAL REPORT SUPERSEDES AND TAKES PRECEDENCE OVER REPORT DATED FEB RUARY 6, 1959, AND REPORT 6280 DATED DECEMBER 28, 1962, THERERY REMOVING AND MAKING IN VALID THE APPROVAL REPORT AS DATED FEBRU ARY 6, 1959, AND REPORT 6280 AS DATED DECEM BER 28, 1962. The Committee on Compliance has reviewed the data submitted on August 11, 1958, together with new test re ports submitted on July 19, 1963, for compliance with the Southern Standard Building Code and submits its Report as follows: DESCRIPTION: Bestwall Firestop is a gypsum wallboard having a spe cial core formulation under a patented process in which in combustible glass fibers and unexpanded veimiculite have been added to the gypsum core. It is manufactured in Vz" and %" thicknesses. Firestop is mrde generally in 4 ft. wide sheets with tapered edges and a inished wall or ceiling includes the conventional tape and cement joint system. It is also available with a squaie edge r tongue and grooved edges and also in 2 ft. and 4 ft. wio-hs for use as an un finished fire rated assembly as a garage wall or a backup for further treatment as acoustical tile, etc. USES: Wall, floor and ceiling assemblies, for load bearing and non-load bearing with fire retardant properties. Framing consists of metal or wood studs, bar joist or wood joist for load bearing and non-load bearing assemblies and no frames for non-loaa bearing partitions. SUBSTANTIATING DATA: 1. Manufacturers literature. (a) Sweet's insert 1963--Bestwall Gypsum Wallboard --Form BW-62250. (b) Fire Resistive Ratings--Bestwall Firestop--Form BW-62465. 2. Copies of Official Fire Test Reports made under ASTM E 119. Underwriter Retardant Underwriter Retardant Underwriter Retardant 2o89 2717-7-8 3843 2717 Underwriter Retardant Underwriter Retardant 2717-16 2717-19-21 Underwriter Retardant Underwriters Retardant 2717-20-22 2717-26 Underwriters Retardant 2717-27 Ohio State Experimental Station Report T-209 Ohio State Experimental Station Report T-194 Ohio State Experimental Station Report T-2406--January 1963 Underwriters Letter Repo rt July 20, 1962 8/5/47 7/12/51 12/27/55 12/1/52 6/3/57 8/26/57 3/27/63 4/22/63 Loadbearing Partition Floor and Ceiling N.n-Load Bearing Partition Floor and Ceiling Non-Load Bearing Wall Wood studs Wood joist & floor 1 hr. 1 hr. Metal studs Steel Bar Joists Semi- Solid Hummer "B" 1 hr. 1 hr. 1 hr. Non-Load Bearing Wall Floor and Ceiling Floor and Ceiling Semi-Solid Modified Steel Bar Joist Steel Bar Joists 2 hr. 3 hr. l'/2 hr. 2 hr. Load Bearing Wall Metal studs Load Bear ing Wall Wood studs Non-Load Bearing Wall Metal studs Tape and cement not required for fire resistive ratings. 1 hr. 2 hr. 2 hr. SGP 0025288 REFERENCES TO SOUTHERN STANDARD BUILDING CODE: Chapter X--Fire Resistance Rating for Materials and Construction. IDENTIFICATION: Bestwall Firestop is shipped twin mounted (2 boards face to face) and an end bundling tape with the U. L. Mani fest (label) on each end. All Bestwall Firestop sheets shall carry a face marking in the center of the board, repeated every five feet (or %") Bestwall Firestop Type "X". COMMITTEE FINDINGS: The Committee on Compliance in review of the data sub mitted finds that, in their opinion, %" thick Bestwall Fire stop Constructions meet the provisions of the Southern Stand ard Building Code as follows: (A)--%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where 1 hour fire 1 'sistance, load bearing or non-load bearing, combustible or incombustible wall and partition or floor and ceiling construction is required. (B) -- %" Bestwall Firestop in multipl' layer 2 layer) application in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 2 hour fire resistive walls and partitions, load-bearing or non-load bearing, combustible or incombustible is required. (C)---%" Bestwall Firestop in multiple layer applica tion in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 3 hours non-load bearing fire resistive walls and partitions are required. (D)--%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where IV2 and 2 hour fire re sistive floor and ceiling incombustible construc tion is required. (E)--In view of the Fire Hazard Classification show ing a 10 to 15 Flame Spread Rating, %" Bestwall Firestop shall not be limited under the South ern Standard Building Code other than as above in A, B, C and D. (F)--Height of non-load bearing frameless partition shall be limited to 12 ft. Maximum height of frame partitions shall be governed by rules on frame material (including section) used, j (G)--Joints may be taped or untaped depending on the erectors desires since the taping of joints has no effect on the retardant ratings. COMMITTEE RECOMMENDATIONS: The Committee recommends that %" thick Bestwall Firestop uses and limitations as set forth in this Report be approved by the Southern Building Code Congress. LIMITATIONS: That Bestwall Firestop shall be made under Under writers Inspection Service, listed by Underwriters Labora tories and carry the U. L. Manifest on the end bundling tape. PERIOD OF APPROVAL: This Approval or Certificate of Compliance will be in effect as long as the product "Bestwall Firestop" is listed bv Underwriters Laboratories and manufactured under Unceiwriters' Inspection Service. Should any revision or changes of method of construction occur, this Approval shall terminate. This, however, is not to be construed to preclude any new submittals. Qxvuasyl. Moses^Vinter Park, Florida SGP 0025289