Paoli, Pennsylvania March 23, 1965
To: All Regional Sales Managers All Area Sales Managers All Salesmen
Cc: Mr. R.I. Fredericks Mr. K.A. McCaskill
Paoli Paoli
General Sales Bulletin #20-65
Subject: 5/8" THICK BESTWALL FIRESTOP Re: Southern Building Code Congro Report #63UU
By: G.C. Moore /ghp
File - Wallboard Manual Section 10
Attached are two (2) copies of the subject Committee on Compliance Approval Report dated October 10, 1963. This is a reissue of a previous Report #6280.
You will note that this Report has dropped the Underwriters' Retardant Report ^R2717-23 and the following have been included, 1) Floor and Cdiling Construction, Report 4R2717-26 or UL Design #13 for 1- Hours. 2) Under Floor and Ceiling Construction, Report #R2717~27 or UL Design #69 for 2 Hours, 3) Partition System using 5/8" Firestop vinyl clad with the Neslo "Z" stud, covered under Report #T-2lj06 for 2 Hours.
Destroy the old Approval Report #6280.
Additional copies of this sheet are available upon request. The Official Test Reports are available when Building Officials require them for their approval and record.
PLAINTIFF'S EXHIBIT GP-806
SGP 0025285
COMMITTEE
MYRON i. SASSER. Chm. L. P. HAMILTON THOMAS M. MOSES
BROWN-MARX BUILDING
BIRMINGHAM, ALABAMA
REPORT: 6344 APPROVED: 10-10-63 EXPIRES:
COMMITTEE on COMPLIANCE APPROVAL
ON
%" THICK BESTWALL FIRESTOP
MANUFACTURED BY
BESTWALL GYPSUM COMPANY
SOLD THROUGH
BESTWALL CERTAIN-TEED SALES CORPORATION
ARDMORE, PENNSYLVANIA
REPORT
The Manufacturer made formal application on July 19, 1963, for re-evaluation of their Approval Report No. 6280, dated December 28, 1962, requesting that Underwriters Re tardant report 2717-23 be removed from the Report and that Unde, writers Retardant reports number R 2717-26, R 271727 and Ohio State University report number T 2406 be in cluded in this Approval Report.
THIS APPROVAL REPORT SUPERSEDES AND TAKES PRECEDENCE OVER REPORT DATED FEB RUARY 6, 1959, AND REPORT 6280 DATED DECEMBER 28, 1962, THEREBY REMOVING AND MAKING IN VALID THE APPROVAL REPORT AS DATED FEBRU ARY 6, 1959, AND REPORT 6280 AS DATED DECEM BER 28, 1962.
The Committee on Compliance has reviewed the data submitted on August 11, 1958, together with new test re ports submitted on July 19, 1963, for compliance with the Southern Standard Building Code and submits its Report as follows:
DESCRIPTION:
Bestwall Firestop is a gypsum wallboard having a spe cial core formulation under a patented process in which in combustible glass fibers and unexpanded vermiculitc have been added to the gypsum core. It is manufactured in M"
and %'' thicknes s. Firestop is made generally in 4 ft. wide sheets with t; )ered edges and a finished wall or ceiling includes the convt tional tape and cement joint system. It is also ava'lable \ h a square edge or tongue and grooved edges and also in ft. and 4 ft. widths for use as an un finished fire ratet assembly as a garage wall or a backup for further treatment as acoustical tile, etc.
USES:
Wall, floor and ceiling assemblies, for load bearing and non-load bearing with fire retardant properties. Framing consists of metal or wood studs, bar joist or wood joist for load bearing and non-load bearing assemblies and no frames for non-load bearing partitions.
SUBSTANTIATING DATA:
1. Manufacturers literature.
(a) Sweet's insert 1963--Bestwall Gypsum Wallboard --Form BW-62250.
(b) Fire Resistive Ratings--Bestwall Firestop--Form BW-62465.
2. Copies of Official Fire Test Reports made under ASTM E 119.
Underwriter Retardant
2889
Underwriter Retardant
Underwriter Retardant
2717-7-8
3843 2717
Underwriter Retardant
2717-16
Underwriter Retardant
2717-19-21
Underwriter Retardant
2717-20-22
Underwriters Retardant
2717-26
Underwriters Retardant
2717-27
Ohio State Experimental Station Report T-209
Ohio State Experimental Station Report T-194
Ohio State Experimental Station Report T-2406--January 1963
Underwriters Letter Report July 20, 1962
8/5/47 7/12/51 12/27/55 12/1/52 6/3/57 8/26/57 3/27/63 4/22/63
Loadbe- ring Partition
Wood studs
1 hr.
Floor a id Ceiling
Wood joist & floor
1 hr.
N.n-Load Bearing Partition
Metal studs
1 hr.
Floor a: I Ceiling
Steel Bar Joists
1 hr.
Non-Load Bearing Wall
Semi- Solid Hummer "B" I hr.
Non-Load Bearing Wall
Semi-Solid Modified
2 hr. 3 hr.
Floor and Ceiling
Steel Bar Joist
1M> hr.
Floor and Ceiling
Steel Bar Joists
2 hr.
Load Bearing Wall
Metal studs
I hr.
Load Bear ing Wall
Wood studs
2 hr.
Non-Load Bearing Wall
Metal studs 2 hr.
Tape and cement not required for fire resistive ratings.
SGP 0025286
REFERENCES TO SOUTHERN STANDARD BUILDING CODE:
Chapter X--Fire Resistance Rating for Materials and Construction.
IDENTIFICATION:
Bestwall Firestop is shipped twin mounted (2 boards face to face) and an end bundling tape with the U. L. Mani fest (label) on each end.
All Bestwall Firestop sheets shall carry a face marking
in the center of the board, repeated every five feet
(or
%") Bestwall Firestop Type "X".
COMMITTEE FINDINGS:
The Committee on Compliance in review of the data sub mitted finds that, in their opinion. %" thick Bestwall Fire stop Constructions meet the provL.ons of the Southern Stand ard Building Code as follows:
(A) --%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code v here 1 hour fire resistance, load bearing or non >ad bearing, combustible or incombustible wall id partition or floor and ceiling construction h required.
(B) --%" Bestwall Firesto in multiple layer (2 layer) application in the co itruction as detailed in the fire test reports ir. 'ets the provisions in the Southern Standard Building Code whore 2 hour fire resistive walls and partitions, load-bearing or non-load bearing, combustible or incombustible is required.
(C)--%" Bestwall Firestop in multiple layer applica tion in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 3 hours non-load bearing fire resistive walls and partitions are required.
(D) --%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where lVz and 2 hour fire re sistive floor and ceiling incombustible construc tion is required.
(E)--In view of the Fire Hazard Classification show ing a 10 to 15 Flame Spread Rating, %" Bestwall Firestop shall not be limited under the South ern Standard Building Code other than as above in A, B, C and D.
(F)--Height of non-load bearing frameless partition shall be limited to 12 ft. Maximum height of frame partitions shall be governed by rules on frame material (including section) used.
(G)--Joints may be taped or untaped depending on the erectors desires since the taping of joints has no effect on the retardant ratings.
COMMITTEE RECOMMENDATIONS: The Committee recommends that %" thick Bestwall
Firestop uses and limitations as set forth in this Report be approved by the Southern Building Code Congress.
LIMITATIONS: That Bestwall Firestop shall be made under Under
writers Inspection Service, listed by Underwriters Labora tories and carry the U. L. Manifest on the end bundling tape.
PERIOD OF APPROVAL: This Approval or Certificate of Compliance will be in
effect as long as the product "Bestwall Firestop" is listed by Underwriters Laboratories and manufactured under Under writers' Inspection Service. Should any revision or changes of method of construction occur, this Approval shall terminate. This, however, is not to be construed to preclude any new submittals.
L. P. Hamilton, Columbia, South Carolina ^o^m^MT^oses^Vinter Park, Florida
SGP 0025287
COMMITTEE
MYRON J. SASSER, Chm. L. P. HAMILTON THOMAS M. MOSES
BROWN-MARX BUILDING
BIRMINGHAM, ALABAMA
REPORT: 6344 APPROVED: 10-10-63 EXPIRES:
COMMITTEE on COMPLIANCE APPROVAL
ON
s/8" THICK BESTWALL FIRESTOP
MANUFACTURED BY
BESTWALL GYPSUM COMPANY
SOLD THROUGH
BESTWALL CERTAIN-TEED SALES CORPORATION
ARDMORE, PENNSYLVANIA
REPORT
The Manufacturer m. ie formal application on July 19, 1963, for re-evaluation of their Approval Report No. 6280, dated December 28, 1962, 'equesting that Underwriters Re tardant report 2717-23 bo emoved from the Report and that Underwriters Retardant r.ports number R 2717-26, R 271727 and Ohio State Unive sity report number T 2406 be in cluded in this Approval Report.
THIS APPROVAL REPORT SUPERSEDES AND TAKES PRECEDENCE OVER REPORT DATED FEB RUARY 6, 1959, AND REPORT 6280 DATED DECEMBER 28, 1962, THERERY REMOVING AND MAKING IN VALID THE APPROVAL REPORT AS DATED FEBRU ARY 6, 1959, AND REPORT 6280 AS DATED DECEM BER 28, 1962.
The Committee on Compliance has reviewed the data submitted on August 11, 1958, together with new test re ports submitted on July 19, 1963, for compliance with the Southern Standard Building Code and submits its Report as follows:
DESCRIPTION:
Bestwall Firestop is a gypsum wallboard having a spe cial core formulation under a patented process in which in combustible glass fibers and unexpanded veimiculite have been added to the gypsum core. It is manufactured in Vz"
and %" thicknesses. Firestop is mrde generally in 4 ft. wide sheets with tapered edges and a inished wall or ceiling includes the conventional tape and cement joint system. It is also available with a squaie edge r tongue and grooved edges and also in 2 ft. and 4 ft. wio-hs for use as an un finished fire rated assembly as a garage wall or a backup for further treatment as acoustical tile, etc.
USES:
Wall, floor and ceiling assemblies, for load bearing and non-load bearing with fire retardant properties. Framing consists of metal or wood studs, bar joist or wood joist for load bearing and non-load bearing assemblies and no frames for non-loaa bearing partitions.
SUBSTANTIATING DATA:
1. Manufacturers literature.
(a) Sweet's insert 1963--Bestwall Gypsum Wallboard --Form BW-62250.
(b) Fire Resistive Ratings--Bestwall Firestop--Form BW-62465.
2. Copies of Official Fire Test Reports made under ASTM E 119.
Underwriter Retardant
Underwriter Retardant
Underwriter Retardant
2o89
2717-7-8 3843 2717
Underwriter Retardant
Underwriter Retardant
2717-16 2717-19-21
Underwriter Retardant
Underwriters Retardant
2717-20-22 2717-26
Underwriters Retardant
2717-27
Ohio State Experimental Station Report T-209
Ohio State Experimental Station Report T-194
Ohio State Experimental Station Report T-2406--January 1963
Underwriters Letter Repo rt July 20, 1962
8/5/47 7/12/51 12/27/55 12/1/52 6/3/57 8/26/57 3/27/63 4/22/63
Loadbearing Partition
Floor and Ceiling
N.n-Load Bearing Partition
Floor and Ceiling
Non-Load Bearing Wall
Wood studs
Wood joist & floor
1 hr. 1 hr.
Metal studs
Steel Bar Joists
Semi- Solid Hummer "B"
1 hr. 1 hr. 1 hr.
Non-Load Bearing Wall
Floor and Ceiling
Floor and Ceiling
Semi-Solid Modified
Steel Bar Joist
Steel Bar Joists
2 hr. 3 hr.
l'/2 hr.
2 hr.
Load Bearing Wall
Metal studs
Load Bear ing Wall
Wood studs
Non-Load Bearing Wall
Metal studs
Tape and cement not required for fire resistive ratings.
1 hr. 2 hr. 2 hr.
SGP 0025288
REFERENCES TO SOUTHERN STANDARD BUILDING CODE:
Chapter X--Fire Resistance Rating for Materials and Construction.
IDENTIFICATION:
Bestwall Firestop is shipped twin mounted (2 boards face to face) and an end bundling tape with the U. L. Mani fest (label) on each end.
All Bestwall Firestop sheets shall carry a face marking
in the center of the board, repeated every five feet
(or
%") Bestwall Firestop Type "X".
COMMITTEE FINDINGS:
The Committee on Compliance in review of the data sub mitted finds that, in their opinion, %" thick Bestwall Fire stop Constructions meet the provisions of the Southern Stand ard Building Code as follows:
(A)--%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where 1 hour fire 1 'sistance, load bearing or non-load bearing, combustible or incombustible wall and partition or floor and ceiling construction is required.
(B) -- %" Bestwall Firestop in multipl' layer 2 layer) application in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 2 hour fire resistive walls and partitions, load-bearing or non-load bearing, combustible or incombustible is required.
(C)---%" Bestwall Firestop in multiple layer applica tion in the construction as detailed in the fire test reports meets the provisions in the Southern Standard Building Code where 3 hours non-load bearing fire resistive walls and partitions are required.
(D)--%" Bestwall Firestop in single layer application in the construction as detailed in the fire test re ports meets the provisions in the Southern Stand ard Building Code where IV2 and 2 hour fire re sistive floor and ceiling incombustible construc tion is required.
(E)--In view of the Fire Hazard Classification show ing a 10 to 15 Flame Spread Rating, %" Bestwall Firestop shall not be limited under the South ern Standard Building Code other than as above in A, B, C and D.
(F)--Height of non-load bearing frameless partition shall be limited to 12 ft. Maximum height of frame partitions shall be governed by rules on frame material (including section) used, j
(G)--Joints may be taped or untaped depending on the erectors desires since the taping of joints has no effect on the retardant ratings.
COMMITTEE RECOMMENDATIONS: The Committee recommends that %" thick Bestwall
Firestop uses and limitations as set forth in this Report be approved by the Southern Building Code Congress.
LIMITATIONS: That Bestwall Firestop shall be made under Under
writers Inspection Service, listed by Underwriters Labora tories and carry the U. L. Manifest on the end bundling tape.
PERIOD OF APPROVAL: This Approval or Certificate of Compliance will be in
effect as long as the product "Bestwall Firestop" is listed bv Underwriters Laboratories and manufactured under Unceiwriters' Inspection Service. Should any revision or changes of method of construction occur, this Approval shall terminate. This, however, is not to be construed to preclude any new submittals.
Qxvuasyl. Moses^Vinter Park, Florida
SGP 0025289