Document qgpGObxkxVgxNLBNjE2zJ4RM
MATERIAL SAFETY DATA SHEET CFR 1910.1200 OSHA Haxard
-.OMosicatioa RaU Format
HIRE SAFETY APPLIANCES COMPANY
p. o. Box 426
Pittabargh, PA 15230 PHONE (412) 967-3000
NOTE: This produce contains Stannic Chloride, a substance subject to the Pennsylvania Worker and Community Righc-To-Know Act.
PRODUCT IDENTITY
LABEL IDENTITY CHEMICAL NAME -
MSA P/N 5607 VentiLstion Smoke Tube Assembly MSA P/N 5645 Ventilation Smoke Tubes (pkg. of 12)
Stannic Chloride Sorbed on Pumice
ADDITIONAL IDENTITIES - Smoke Tubes
FORMULA -
SnCl4 00 Pumice
APPLICABLE CHEMICAL CONTENTS
*'annic Chloride (CAS 7646-78-8) Pumice (CAS 1332-09-8)
%
50-60
40-50
TLV 2mg/m>
lQng/m3
*A* inorganic tin compounds
Each tube contains approximately 2 gas. SnCl4
CAUTION:
SnCl4 reacts with moisture in air yielding tin oxides saoke, and hydrochloric
acid. This aixture is irritating to the eyes and mucous membranes. Avoid
contact vith smoke puffs pumped from the tube.
Tube effluent contains
TLV
HC1 (CAS 7647-01-0) Tin Oxides (no CAS number known)
7ag/aJ Ceiling 2mg/m3 (49 inorganic
Tin Compounds)
SnClA (CAS 7646-78-8)
2ag/m3 (as inorganic Tin Compounds)
ACCIH TLVs 1987-88
Page l of 4
Part 4-Attachment #5
MSA P/N 5645
PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE AND ODOR - Gray co Black Granule*, Acid Odor
BOILING POINT - SnCU 235* P
VAPOR PRESSURE - SnCl.4 l0-20mm HG ac Room Temp. VAPOR DENSITY (AIR,- 1) - I
SPECIFIC GRAVITY PERCENT VOLATILE
SOLUBILITY IN WATER -- SnCl.4 soluble decomposes
(H2<>*1>- >1 BY VOLUME -
Appro*.
50?
PHYSICAL HAZARD INFORMATION
PHYSICAL HAZARD - SnCl.4 is strongly acidic and reacts with water vapor yielding tin oxides smoke and corrosive hydrochloric acid mixture.
CONDITIONS OR MATERIALS TO AVOID - Avoid strong bases, alcohols, ethylene oxide, alkyl nitratca, and aainea.
FLASH POINT - SnCU is not flansaable.
LEL N/A
UEL N/A
EXTINGUISHING MEDIA - Aa needed for surrounding fire.
SPECIAL FIRE FIGHTING PROCEDURES - Wear impervious covering and aalf-contained praaaure demand breathing apparatus with full facepitct.
UNUSUAL FIRS AND EXPLOSION HAZARDS - Tubes may rupture end emit toxic fumes sad dense smoke
under firs conditions. Avoid contact with run-off water which may be acidified by leached tub contenta.
HEALTH HAZARDS
HEALTH HAZARDS - Corroaive, Toxic, Irritant
SnCl4: inh Rat LC50 2300g/3 10 minutes HCl: INH Human LCLo 1300ppm 30 minutes
SIGNS AND SYMPTOMS 07 EXPOSURE - Eye, skin, end respiratory system irritation, coughing, shortness of breath, headache, nausea, vomiting. Direct contact with liquid SnClg produces acid burns.
PRIMARY ROUTES OF ENTRY: Eyes, nose, mouth, skin
TARGET ORGANS: Eyes, mucous membranes, skin
N/A - Not Applicable
Page 2 of 4
DO A 043899 CONFIDENTIAL
MSA P/N 5645
MEDICAL CONDITIONS GENERALLY RECOGNIZED AS BEING AGGRAVATED BY EXPOSURE - No information
EXPOSURE LIMITS - See page 1
CARCINOGENICITY DATA - Not listed in NIOSH RTECS.
EMERGENCY AND FIRST AID PROCEDURES -
Smoke puff generation is under manual control of the user by actuation of a squeeze bulb and overexposure is unlikely under intended conditions of use. First aid procedures follow should overexposure somehow occur. Eyes: Remove victim from exposure. Flush eyes with water for 15 minutes holding eyes
open and raising eyelids to flush underlid areas. SEE A PHYSICIAN IMMEDIATELY.
Inhalation: Remove from exposure. Give oxygen if breathing is difficult. Give artificial respiration if breathing, has stopped. GET MEDICAL ATTENTION IMMEDIATELY
Ingestion: If tube contents are-somehow ingested, give 2 glasses of water to dilute chemical. Do not induce vomiting. GET MEDICAL ATTENTION IMMEDIATELY.
SAFE HANDLING AND USE
HYGIENIC PRACTICES - Wash hands after using product.
PROTECTIVE MEASURES DURING REPAIR AND MAINTENANCE OP CONTAMINATED EQUIPMENT - Not Applicable
PROCEDURES FOR SPILL OR LEAR CLEANUP If contents of a tube are released, leave area until smoke generation subsides. Avoid skin contact with spilled material and avoid breathing any smoke generated. Fill a bucket 3/4 full of water and add 1 ounce of sodium bicarbonate. Sweep up the tube and spilled contents and place in the bucket overnight to completely deactivate remaining chemical. Filter solids from water and dispose to trash. Neutralized water can be poured down drain.
Page 3 of 4
DO A 040900 CONFIDFNTTAL
MSA P/M 5645
WASTE DISPOSAL - Tape over ends of exhausted tubes aad dispose in accordance with local, sc and federal regulations.
STORAGE - Store tubes in a cool dry location protected from crushing and impact forces.
CONTROL MEASURES PERSONAL PROTECTIVE EQUIPMENT - Due to the limited amount of SnCl^ per tube and the control
smolte release rate, use of personal protective equipment is not indicated under antlcipa conditions of use. The user is cautioned to avoid breaching the cube emissions which ar irritant.
ENGINEERING CONTROLS - Not Applicable. WORK PRACTICES: This product is for use in determination of direction and velocity of
ventilation air currents. Avoid breathing emissions from tube. DATE OF PREPARATION - January 1988
The information provided herein has been compiled from sources believed to be reliable. However, Mine Safety Appliances Company makes no warranty as to the accuracy, completeness or sufficiency of the information and in no event will Mine Safety Appliances Company be responsible for loss or damage of any nature whatsoever resulting from use of the infor mation.
Page 4 of 4
00 A rw