Document qdpvXG6Zgeon3oQqg5mjyq235
Union Carbide Agricultural Products Company,
Institute Plant
Inc.
INDUSTRIAL HYGIEN E SAMPLING RESULTS
TO: Mr. G. F. Morris COPIES TO:
Mr. P. C. Bowyer
Building: 23_________________________
Mr. C. W. Hill, Jr.-----------------------
Institute Plant______________________
Mr. L. V. Youngblood
Purpose:
_________ Routine
X
Special Request
_________ Regulatory Agency Inspection
Sample Date(s): November 13, 1986
Sample Location:
Boilermaker Shop______________ Department No.:
327
Process/Activity:
HAVEG Vessel Repair___________
Contaminant:
Asbestos Fibers______________________________
Exposure Limit: OSHA Q.2f/cc(TWA^);~
(TWA^)
ACGIH 0.2f/cc(TWA >;-(TWA^)
Sample Type:
UCC
________________________(TWA );-(TWA ) 8
X Personal
X Area
________ Source
LA
Surface Wipe
________ Other (See comments)
Analytical Method:
Per 29 CPR 1910.1001, Appendix A
Results: _______ See Comments
X See Attached Table
COMMENTS: Two boilermakers were monitored for exposure to airborne asbestos
fibers on the above date while making repairs to a HAVEG vessel. The
material of construction was known to contain asbestos since the vessel was
fabricated prior to 1980. Repairs were made by using a hammer and chisel to
chip away the HAVEG material bonding several nozzles to the vessel body.
Non-asbestos bonding material was later applied to complete the repairs.
The vessel, which was roughly 2.5 feet in diameter and 15 feet long, was
positioned horizontally in the shop and had both ends open while chipping was
performed. The locations of the defects required the boilermakers to lie
inside the vessel at times. Dust controls such as misting and local exhaust ventilation were not used. However, the two boilermakers wore full-facepiece
airline respirators and Tyvek suits with boots and hoods.
A0399 1
UCC 008974
Union Carbide Agricultural Products Company,
Institute Plant
Inc.
I N D U S T R I A L HYGIENE SAMPLING RESULTS
Barrier ropes and warning signs were placed around the worksite to restrict access. An area sample was obtained at the barrier to evaluate the airborne concentration of asbestos fibers.
The eight-hour time-weighted average exposures for the boilermakers were below the permissible exposure limit and below the action level (i.e_,less than one-half the PEL). This is due to the fact that the duration of the chipping activity was relatively short. Had the chipping taken much longer, it is likely that the exposures would have been excessive, since the short term exposure concentrations ranged from 0.16 to 0.95 fibers/cc. The airborne concentration at the barrier rope was less than the action level.
Currently, no action is required except that these monitoring results must be reviewed with all affected employees (i.e., all boilermakers who may at times repair HAVEG vessels containing asbestos). In lieu of reviewing the results, a copy of the results can be posted in the boilermaker shop where all affected employees can see it.
RECOMMENDATIONS: In order to prevent excessive exposures to asbestos fibers during HAVES repair, one or more of the following control methods should be used on future gobs when feasible.
1. A fine water mist should be applied continually at the point of chipping to prevent fibers from becoming airborne. A simple spray bottle can be used to do this.
UCC 008975
Union Carbide Agricultural Products Company,
Institute Plant
Inc.
INDUSTRIAL HYGIENE SAMPLING RESULTS
2. Local exhaust ventilation equipment including a high efficiency particulate air (HEPA) filter system should be used to remove airborne fibers from the work area and reduce or prevent exposure. An example of such equipment would be a "negative air machine", typically used during asbestos abatement projects. The versatility of such a machine would make it useful for other applica tions.
3. Use glove bags to enclose the work area on the vessel and thus prevent the spread of asbestos fibers. Though de signed primarily to enclose a section of pipe for insula tion removal they could be adapted to this type of work very easily.
If you have any questions or require any assistance in pursuing these control strategies, please call me.
Report Date: Signed: NOTE:
January 12, 1987
Bldg. 2
Room: 172 Phone
PERSONAL SAMPLE RESULTS MUST BE DISCUSSED
WITH ALL AFFECTED EMPLOYEES
6105
2182k
A03993
UCC 008976
Union Carbide Agricultural Products Company,
Institute Plant
Inc.
INDUSTRIAL HYGIENE SAMPLING RESULTS
WORKPLACE LOCATION: Boilermaker Shop
NAME(s) OE SAMPLER(s): J. L- Miller
CONTAMINANT: Asbestos Fibers_____________ OSHA PEL: TWAg Q.2f/cc TWA12 ~
REPORT DATE: January 12, 1987 ACGIH TLV: TWA8 0.2f/cc TWA12___-____ UCC GUIDELINE: TWAg - TWA12 ~
Sample Number
Sample Date
W4768 AA1G436 W4768 AA10441
W4768 AA10437
W4768 AA10438
11-13-86 11-13-86 11-13-86
11-13-86
Sample Description
BOILERMAKER c. E. Adkins c. E. Adkins
J. E. Higginbotham, Jr.
At barrier tape ten feet from end of vessel.
Sample Time (min.)
Sample Results (f/cc)
CO
o
38
10 TWAg =
0.95 0.06
48 0.16
TWAg =
0.016
52 0.085
UCC 008977