I EXHIBIT I j WBP M-2 j LKB 9000 GAS CHROMATOGRAPH - MASS SPECTROMETER The complete Instrument for gas chromatography and mass spectrometry MON-MT-008538 CoprityM (C) 196S UlFiodwktai Afc TOWOLDMONOOQ3170 Versatility The LKB 9000 is a fully equipped combination instrument providing simple, reliable and flexible operation in the routine mass spectromctric anal ysis of organic substances which have been purified by the built-in gas chro matograph. It utilizes the most advanced and sophisticated methods and instru mentation for each of its important unit operations, from sample introduction into the gas chromatograph to recording of a mass spectrum. Alternative inlet systems are provided for operation of the mass spectrometer with previously purified liquids and solids. Wc arc justly proud of the performance of this first commercial instrument to integrate a gas chromatograph, a molecule separator and a mass spectrometer into one unit, an instrument which is eminently suit able for: Biochemical Analysis Identification of Trace Components in Complex Mixtures 0 Elucidation of Molecular Structures 0 Studies of Isolope Abundance Block diagram of LKB 9000 gafi chromatograph - mast tpocUomalar. m P'> >< pi Jj Flov 1^ A' .' t ' K^jcv ; . now Control Vtv* ?p*;d Tgmperelur* Prgjirdmmer ...sMoUcUa^r^j ..-iL. ... nn iiTo Mi.elPump'; Ing 8yetem Tmj>*nrtvr# Controller vl!`' \y vyyi'A-:'/v: LrA''-'";, ;Lf vid'.WSK'L EnilMlon ContrpflMt ,,^6oa ;V .Cfttiwectton igr ?ll''^OT5s3 .4ij TOWOLDMONOOQ3171 tKB 0000 showing iho an&lyxet unit (on Uft) and the control unit. Advanced instrumentation GAS CHROMATOGRAPHY for the preliminary pur ification of organic compounds in complex mixtures is achieved with coiled columns housed in a compact oven. A circulating air bath assures accurate temperature regulation in isothermal or temperature-programmed operation. SAMPLE ENRICHMENT in a unique molecule separa tor*, is carried out by the preferential removal of carrier gas from the effluent stream of the gas chromatograph. IONIZATION is achieved by electron impact. Automatic regulation of electron energy provides optimal levels of ionization during operation of the ion source as a GLC detector, and for the reproducible production of an array of fragment ions during recording of a mass spectrum. Mass spectra arc obtained with a rapid-scanning, singlefocusing magnetic sector analyzer with sufficient resolving power for operation with compounds in a molecular weight range up to 1200. Optimal resolving power under different operating condi tions is made possible with externally variable ion source and collector slits, * According to Btckoi, KttnlortchunDiicnlrum, Ktrliruho, nd Ryhtne, Kfirollmbo IntUtulot, Stockholm, MON-MT-008540 TOWOLDMONOOQ3172 Gas Chromatography Components for the GLC inlet are designed to provide op timal performance with the most demanding chromato graphic conditions. Minimum dead volume and effective uniform heating of all parts ensure symmetrical peaks with no loss of column efficiency, even with capillary col umns and long packed columns. This is well illustrated by the chromatogram on this page which shows the separation of hydrocarbons from Kerosene in a temperature pro grammed analysis on a 1 % SK-30 column 15 meters in length. Electron Multiplier Assembly Sftmpltt Column; ...... - . iuciai,* pt>m Bopper opiums Column PeeWnfl! .\ 1weVosbMedS,4QelloenitlWiedmBeni-oCthhromemm48 - K. vP-. r.'.-.f' : Hollum Inlet Proeiure: 3.5 bn/om' is?:yf: Helium flow Rete: $0 mvmln. : |fviS-v> :V.f <&>. y * 0; TOWOLDMONOOQ3173 High Sensitivity i \ i Due to the fact that minute samples may be used (0.01 mi crogram with a capillary column or 0.1 microgram with a packed column is sufficient for a complete mass spectrum), the I.KB 9000 is ideal for studies of analytical problems in biochemistry. It is eminently suitable for the analysis of amino acid and carbohydrate derivatives, steroids and bile acid esters, insecticides and for studies of lipid metabolism. Mass spectra of biologically important high molecular compounds are easily obtained following purification with the GLC inlet. With this inlet, a resolving power of more than 600 can be attained, Under ideal operating conditions using an all-glass or direct probe inlet M/AM is 1000 at ionsource exit slit and collector slit settings of 0.05 and 0.10 mm respectively (10% valley definition). Fast scan (m/a 24-400 In 1 tec.) of 0.5 vq dohydroepianrfrosterono trimothylsity] other. MON-MT-008542 TOWOLDMONOOQ3174 Sample Enrichment Substances eluted from the GLC column are carried along with the helium carrier gas into the molecule separator, which, in two stages, preferentially removes most of the helium, while the sample passes into the ion source chamber in a highly concen trated molecular beam. The jet-type separator, of Bcckcr-Ryhage design, is equipped with forcvacuum and diffusion pumps. The unit provides a pressure drop from approximately atmospheric to about 10"4 mm Hg, and is effective with organic compounds of all molecular weights. The large pressure drop in the molecule separator enables operation of the spectrometer at less than 10' mm Hg. Independent, controlled beating of the separators prevents sample condensation. GLC Infot System Accessibility Compact arrangement of chromatographic column, molecule separator, valve, and ion source ensures easy operation and negligible zone widening in the effluent prior to ionization. Other Inlets Convenient arrangement of valves facilitates quick switching between the GI.C inlet and the standard all-glass inlet. Provision is made for connection of a direct probe and vacuum lock system. Ion source Inlet valve Molecule separator Flash heater with injection port Column MON-MT-008543 TOWOLDMONOOQ3175 Technical Specifications The l.KH 9000 is a single focusing mass spectrometer, equipped with a 60 sector, 20 cm radius magnetic analy/.cr and a sweep generator for fast scanning of spectra, 'Die ion source is of the electron bombardment type, utilising a rhenium filament and is operated at a vari able accelerating voltage of 3.5 kV maximum. The system for measurement of ion intensity consists of a 14-stagc electron multiplier, followed by an electrometer, and a wide band amplifier feeding a direct-writing UV record ing oscillograph. The high capacity vacuum system consists of two isolated pumping assemblies, one for the analyzer tube and one for the inlet systems, A cold trap is provided for liquid N2 or (X>j, but this need only be used for mass spectral analysis of extremely small samples and during bake-out. Mass range Automatic scanning: Continuously variable m/c 2-1200 Manual adjustment: Continuously variable m/e 2-700 (at 3.5 kV accelerating voltage). Resolution M/AM 1000 at ion source exit slit and collector slit settings of 0.05 and 0.10 mnt respectively (10 /o valley definition). Sensitivity , At optimal performance the required sample amount is less than 0.01 /ig (capillary column) and 0.1 g (packed column). Scanning Magnetic scan, the range of which can be pre-set to any suitable value by means of limit switches. Scanning time 1--960 seconds in 9 steps for full scan. Examples: m/e 12--- 100 in 2.5 sec. m/e 12-- 400 in 4.2 sec. m/c 24-- 800 in 4.2 sec. nt/e 48--1000 in 3.6 sec. M{AM - 1000 m/c 12-- 100 in 1.0 sec. m/c 12--- 400 in 1.7 sec. m/e 24-- 800 in 1.7 sec. m/c 48--1000 in 1.5 sec. M/.dM = 400 Accelerating voltage 2.5, 3.0 and 3.5 kV using 3-stcp selector. Stability better than 0.01 % per 10 min. Magnetic field 0--13 kilogauss, continuously variable. Stability better than 0.01 % per 10 min. Electron energy 10--100 eV. Automatic step-up to pre-selected value dur ing scan (e.g. from 20 to 70 eV), MON-MT-008544 TOWOLDMONOOQ3176 .i -L Ion source exit slit Continuously adjustable 0--0.4 mm from outside the vac uum. Collector slit Continuously adjustable 0--0.6 mm and rotatable -- 2 from outside the vacuum. Electron multiplier 14 dynodes, variable gain JO8--107. The multiplier is fed by a high-voltageD.C. power supply (stability better than 0.01 /o per 10 min.), 1.7--3.7 kV in eleven steps. Recording A collector electrode, located just after the exit slit of the ion source, is connected through an electrometer amplifier to a strip-chart recorder. With GLC, typical chromato grams are produced by continuous recording of total ion current in the spectrometer. With other inlet systems the recorder serves to indicate optimal ion intensity for mass spectral analysis. Mass spectra are recorded at 3 sensitivities on a multi channel UV recording oscillograph, the operation of which is automatically synchronized with the automatic scan. Inlet systems Gas chromatograph and all-glass system for alternative use. Provision made for connection of optional inlet sys tems. Gas chromatograph The cylindrical oven with a circulating air bath accepts coiled columns of variable length but maximum dimen sions of 140 mm (5 'It") coil diameter and 100 mm (4") heights, Column temperatures are regulated by propor tional control (25--350C) for isothermal operation, and can be programmed linearly at rates up to 15C per min. A carrier gas flow meter and flow control regulator are included with the standard instrument. Molecule separator 2-step jet separator of the Becker-Ryhage type, separately heated by means of a built-in temperature controller. Temperature range 50--300C. The enrichment factor is greater than 100 when working with compounds in the molecular weight range above 400. The principles of the molecule separator are protected by patents in V.S.A., West Germany, France, Great Britain, Italy, Canada, and Japan. Vacuum system Analyzer tube: Fore pump Oil diff. pump Mercury booster pump 2.5 m3/h 550 ltrs/sec. 12 ltrs/sec. Cold trap for liquid N2 or COa Ultimate vacuum 10~7 mm Hg (closed inlet valve) Inlet systems: Fore pump Oil diff. pump Mercury booster pump 9.5 ma/h 150 ltrs/sec. 2 ltrs/sec. Gauges: Pirani and Penning type vacuum gauges. Bake-out Analyzer tube and other high vacuum parts can be outgassed at 300--400C by indirect heating. Mains connection 220/380V (220V to ground, 380V between phases) 3phase A.C. Other voltages are suitable, but require a separate transformer, optionally available. Power consumption Approx. 8kVA, unsymmetrical load, max. 15A/pha$e (at 220/380V). Cooling water consumption Approx. 3 ltrs/min., temperature max. 20C (70 F). Dimensions and weights Analyzer unit: h ==125 cm (4 ft. 1 in.) w-- 85 cm (2 ft. 9 in.) 1 = 165 cm (5 ft, 5 in.) Control unit: Approx, weight = 600 kg (1,300 lb) h=150cm (4 ft. 11 in.) w = 105cm (3 ft. 5 in.) 1 =105 cm (3 ft. 5 in.) Approx, weight -- 250 kg (550 lb) LKB INSTRUMENTS, INC., 12221 Parklawn Drive, Rockville, Maryland 20852 Tel: 949-6510 International Headquarters: LKB-Produkter AB, P.O.Box 76, Stockholm-Bromma 1, Sweden MON-MT-008545 Brochure 9000-E01. Printed In Sweden 10M/1065 Graflkon, Stockholm Enbart I0r eprldning utomltnda TOWOLDMONOOQ3177