Document qdneXG9j9Gy490ny6qe4Ddmyx
bcc:
T. L. (Joaaage/D. K. Roush R. A. Garcia - 1010
J. A. Hcilala - Pittsburgh
August 17, 1971
Mr. Tad Scanga Ale ca Nam Kamaington. Pa. 15230 Dear Mr. Scangai Thla will confirm your telephone conversation with our Mr. John Hellala regarding conversion of your heat transfer system from Therminol PR to Therminol 55. We are pleased that you are agreeable to Baking this change as quickly as possible. As indicated in previous correspondence dated June 8, 1970 Thereinol PR is a polychlorinated biphenyl (PCB) and artidee have been published indicating that PCBa have been discovered at sows points in the narine, aquatic and wildlife environments. This ohemioal is a long-lasting, stable material and its ultlaate effeet in the environment is not known. During the past year the PDA has posted guide lines of 5 ppm in food products and 0.2 ppm in dairy products. Because alternate non-PCB heat transfer fluids are available we have taken measures to convert all Thsrmlnol PR users where even the remotest possibility of food contamination exists to materials suoh as Therminol 55 or Thsrmlnol 66. In your case we recommend Therminol 55. You should drain the Therminol PM from your system as thoroughly as possible -- whioh means removing essentially all of the PR fluid. You can then add the Therminol 55 and resume system operation. Sons new Thsrmlnol 55 could be used as a flushing agent to remove any residual PR left in the system. This flush ing material should also be drained and returned for disposal. Ws would like to remind you that Therminol 55 is not classified as a fire resistance heat transfer fluid. Consequently, you may wish to consider the use of protective devleee to minimise any added fire risks. We suggest that you consult with the Insurer of your property relative to this matter.
DSW 018235
STLCOPCB4004780
2 -
Also enclosed Are labels to be plaoed on the containers of drained PH fluid for return to the address shown. We will pay the return freight.
Should you hare any sealed containers of new Therninol PR they oan be returned for full credit but please nark the drums clearly - "for return credit".
Your cooperation is appreciated.
Sincerely,
os enclosures
J. J. Roder Product Supervisor Heat Transfer Fluids
OSW 018236
STLCOPCB4004781