Document qdd298YdJ4v75LbnLodzBL37M
U/d-oa ? % & & (
INTERNAL CORRESPONDENCE
UNION CARBIDE CORPORATION technical center
P.O. BOX 0361, SOUTH CHARLESTON. WV 35303
TolNaon.^
Rucker
D,vision 512/2009
Location
Area
Capvto B. H. Avashia, M.D. - 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 R. E. Coyner - 2009 J. E. Liana - 740/2322 C. P. Maxwell - 701/2 B. R. McMakin - 2009
DBCe June 11, 1987
Originating Dept.
AreB
Subject
Industrial Hygiene Asbestos Exposure Monitoring
. Attached are the results of asbestos exposure monitoring for two days
at the Institute Plant while removing asbestos on a 3-inch steam line at the
#3 dock area. The line stripped was located on risers and an overhead
piperack extending across the railroad tracks. Glovebags and enclosures were
not used because it was not feasible according to the Construction Department
insulation craft representative (Asbestos Competent Person) and the 512 Plant
Industrial Hygiene Department. Employees used a powered man-basket to reach
lines that were overhead. Area was barricaded until removal of asbestos was
completed.
.
r
Two out of six personal exposure samples exceeded the 0.2 fiber/cc permissible exposure level standard and three other personal exposure samples exceeded the 0.1 fiber/cc action level standard. We encourage you to use supplied air respirators as much as possible in the asbestos abatement procedure.
Employees wore two pair of coveralls, headcovers, boots, gloves and AO R57-A half-face HEPA cartridge respirators. No street clothes were worn. They showered before lunch and at the end of the workday before leaving plant.
UCC 011338
ASBESTOS EXPOSURE MONITORING
-2-
June 11, 1987
Please inform of their exposure monitoring results as soon as possible. Have them
sign and date this report and return to M. A. Patel at Building 701-330.
If you have any questions or if we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
VES:HJK:MAP:rab 2385P
Manhar A<; Patel
U
UCC 011339
Date 4-30-87 4-30-87 4-30-87 5-1-87 5-1-87 1-1-87
Sample Type/ Employee Name
Comp. Ref. W2198 W2199
ASBESTOS EXPOSURE MONITORING
Sample Time
Air Cone.
twa8
Fibers/cc Fibers/cc
..................... COMMENTS
6hr 50min
1.153
6hr 46min
0.047
6hr 46min
0.190
0.985 0.040 0.161
Stripped, bagged and vacuumed approx. 100 feet of line at #3 dock.
/
Stripped, bagged and vacuumed approx. 100 feet of line at #3 dock.
ir
Stripped, bagged and vacuumed ' approx. 100 feet of line at
#3 dock.
7hr 3min
0.233
0.205
Stripped, bagged and vacuumed approx. 70 feet of line at #3 dock.
7hr 3min
0.116
6hr 59min
0.119
0.103 0.104
Stripped, bagged and'vacuumed approx. 70 feet of line at #3 dock.
Stripped, bagged and vacuumed approx. 70 feet of line at #3 dock.
384P
UCC 011340