Document qdLMpyQELB9brq2JGN9Y2Njrj

Module 4 AT&T Asbestos Work Practice Course 600518D Telecommunications Related Asbestos Activities OVERHEADS REMOVAL PROCESS rOR RESISTORS TwoPtnom Cut win ktds on back ofpanel Use power tool to ranove two beaut -Remore rvsitor whrr & inmUtor U*e ertHpuitat at needed to teal raiten, wAav and inndatert Wait 20 minxes beftre cortinuhg ranoval SCRIPT 5. Prior to removal, a qualified person must perform an exposure assessment. Removal process for resistors: -Two person operation -One person cuts wire leads on back of panel -Second person uses power tool to remove two hex nuts -Remove resistor, washer and insulator -Use encapsulate, as appropriate, to seal resistors, washers and insulators. WAIT 20 MINUTES BEFORE CONTINUING REMOVAL AND DISPOSAL OPERATION! SG 6 Ifthere is any possibility the resistor has been damaged during the removal process, it must be sealed with an encapsulate before disposal. If asbestos containing washers are identified inside the equipment, the washer and insulator should be encapsulated. PICTORIAL OF ROLLING LADDER BRAKE ASSEMBLY As always, all asbestos containing waste should be disposed properly. 6. The brake lining in rolling ladders equipped with top brakes is typically asbestos. Once the work area is protected, wet the brake lining pad and carefully remove. Properly bag and dispose of the brake lining. 8 5 ATT-NJ-DEG-0077925