Document qd97d5EqwV2qE98eEYBjgx9Zq

$ Silo Sealents as a Source of Pblychlorobiplieiiyl (PCB) Contamination of Animal Feed Ly U. F. Skrentny,* R. J5r. IIemken,* and H. W. Donoccxx* Vnivertity of Kentucky, Lexington, Kentucky 40506 The physical and chemical properties of poly chlorinated biphenyls (PCB's) are ideal for use in a wide range of industrial and commercial materials such aB plastics, polymer films, water-proofing compounds and putty, asphaltic materials, printing inks, waxes and synthetic adhesive (1,2). Because of the numerous applications of PCB's, they are widely distributed in the environment and have reportedly contaminated a number of wildlife species (3,4,5). It has been point ed out that residues of PCB's may interfere with the detection and analysis of certain organochlorine pesticides (5). Recently, Armour and Burke (6) have successfully dealt with this problem and described a silicic acid column method for separating PCB's from DDT and its analogs. The extensive distribution of PCB residues in the environment and their potential hazards have stimulated increased interest in these compounds. Polychlorinated biphenyls were used in the formulation of some paints and sealents which are used on silo walls. Since there is no level of PCB's con sidered safe in milk at the present time, it is important to have information on the potential contami nation of silage by contact with silo walls sealed with materials containing PCB's. Several dairy farmers in Kentucky were recently prevented from shipping milk because of significant levels of PCB residues in their milk. In addition, several other dairy farmers were notified that samples of their milk contained trace levels of iklB's and they would be prevented from shipping their milk if the levels were not maintained or reduced. One of the silos involved in the above mentioned actions had been coated''Sb^yeats earlier with a sealent containing PCB's.*' . .. Our study was initiated to determine the level and department of Entomology ^Department of Animal Sciences 409 Bulletin of Environment*! Coauratnction A Toxicology, Vl. 6, No. &, 1971, published by Springer-Ycrltg N*w York Inc. OSH**** STLCOPCB4079169 distribution of PCB contamination in corn silage from several silos thought to be coated with sealents con taining PCB's. Samples of silo wall chips also were examined for PCB residues, and limited laboratory tests were conducted on ^he solubility of PCB's in water and in a water extract'of silage. Experimental Materials. A sample of Aroclor 1254 for experi mental use was obtained from the Kentucky Department of Health. A standard hexane solution of this material was prepared for gas chromatographic analysis so that 1 microliter of solution contained 1 nanogram of Aroclor 1254. Apparatus. A Varian Aerograph series 1700 gas chromatograph equipped with an electron capture detec tor and a glass column, 10' x 1/8", containing 4% SE 30 and 6% QF 1 (1:1 mixture) on Anakron ABS 80/90 mesh was used for these studies. Operating conditions were as follows: nitrogen 3,5 ml/minute; column temperature, 195C; injector temperature, 200C; detector tempera ture, 200C; standing current, 1.28 x 10-8 AMPS. The recorder speed was 10 inches per hour. Extraction and Cleanup of Samples. A 25-g sample of corn silage was homogenized For 3 minutes with 300 ml of a hexane-isopropyl alcohol (2:1) mixture. The homogenate was filtered and the filtrate transferr ed to a separatory funnel. The alcohol was removed from this mixture by, washing with 300 ml of a 2% NaCl solution. The cori silage sample was homogenized a second time with 150 ml of benzene, filtered and the benzene was addpd to the hexane. This mixture was concentrated to approximately 2 ml and added to a florisil column (2). The column, 22 mm I.D., was packed with 25 g of activated florisil, with approxi mately one inch of anhydrous sodium sulfate added to the column. The PCB's were eluted with 200 ml of hexane. The hexane was concehtrated to 10 ml for gas chromatographic analysis. It was established that DDT and its analogs were not present in sufficient quanti ties to interfere with the quantitation of the PCB's. 'Therefore; separation of the 2 groups of materials on a silicic acid column was not necessary. The extraction and cleanup of the silo wall chips were similar to that employed for silage except that a 5-g sample of silo wall-chips was ground in a mortar with 25 ml of the isopropyl alcohol-hexane mixture and then a second time^ with 25 ml of benzene. The column cleanup was the same as above. <10 tflS9* OS'N STLCOPCB4079170 Collection of Samples. Silage samples were removed from the top of silos that ranged from 12 to 16 feet in diameter. At certain distances from the silo wall, towards the center, a silage sample was collected. A sample representing each distance from the wall con sisted of a composite of.silage from 6 sampling sites. Small chips from each silo wall were taken from 6 points of the exposed wall. All samples were kept frozen until analyzed. Solubility Experiments. An attempt was made to determine the amount of PCB's that would dissolve in water or in a water extract of silage. For this purpose 5 g of the silo wall chips obtained from farm C were placed in flasks with 45 ml of water or with 45 ml of a water extract of silage in the other. The silage extract was prepared by homogenizing 50 g of a silage sample, previously shown to be free of PCB residues, with 200 ml of water. The filtered water from the silage had a pH of 4.3. The flasks were incubated at 37*C with shaking for intervals up to 72 hours. For analysis, 15-ml aliquots were filtered through Whatman No. 5 filter paper to remove the suspended particles. The samples were extracted with hexane, passed through a bed of anhydrous sodium sulfate and concentrated to 10 ml. Determination of PCB Residues. Aroclor 1254 is a mixture of chlorinated biphenyls which produced 17 peaks when analyzed by gas chromatography (Fig. 1). Since pure standards of each peak were not available, a problem relative to how to quantify the residues of PCB's in silage and silo wall samples existed. However, this problem was not too great in this particular study because the relative peak heights were the same in Aroclor 1254, in silo wall chippings and in the silage (Fig. 1, Table 1). Because of this, only peaks J and M were used for quantification. The standards were injected frequently into the gas chromatograph during the analysis and in amounts which approximated the levels of residues in the samples. Owing to inter fering materials, peaks A, B, C and 0, P, Q (Fig. 1) were not always evident in the silage samples. Results and Discussion Gas chromatographic analysis of silo wall chips from the farms included in this study demonstrated that they did contain Aroclor 1254 residues (Fig. 1). Scan II in Fig. 1 is representative of the results obtained from the silo chips and is identical to scan I which is a technical sample of Aroclor 1254. The data shown in Fig. 1 were obtained using a 10 ft column. However, a 41] DSW 332595 STLCOPCB4079171 II 1 Figure 1. Gas chromatographic analysis of (I) a technical sample of Aroclor 1254 and (II) of an extract of silo wall chips from farm B. See methods section for operating parameters. ia DSW 332596 STLCOPCB4079172 6 ft column yielded identical results except that peaks B, C and H, I were not resolved completely. farm A silo contained very small amounts of PCB residues, having an average concentration of only ppm. Farm B contained 10,000 ppm residues of PCB farm C approximately 2,000 ppm. The 10 and In the silage, the greatest amounts of residues were ip material collected within the first 6 inches of the wall (Table 2) . The relative peak heights given in Table 1 show that the PCB's in the silage were similar to Aroclor and that the number of peaks were identical. The residue declined rapidly as the distance from the wall increased and none were detected in samples taken 4 to 6 ft from the silo wall. Silage samples taken at 0 to 2 inches from the wall contained extremely high residues and may have resulted, in part, from small flakes of the sealent in the silage. One sample collected 0-1 inch from the wall of silo C, for example, contained 60 ppm residues of PCB's. However, samples taken at the 2-to 4-inch distance also contained high levels of PCB residues which indicated that the con tamination of the silage was not caused entirely by mechanical means. A decrease in residues was noted in silage samples taken from farm C after a 6 month period. Perhaps the lower levels of PCB residues detected in the second sampling reflect a loss of the PCB as a result of their movement with the liquids which had drained from the sampling area. It was clear from the laboratory experiments that PCB's from the silo wall chips wou}d contaminate . distilled water and a silage extract in which they were placed. The silage extract contained 0.42 ppm after 72 hours (Table 3). These data suggest that the PCB's contaminate silage by being dissolved in the silage liquor which, in turn, moves from the wall, and down ward, spreading the PCB's over a wide area. This con tamination may be enhanced by the action of automatic feeding devices working inside the silo which mix highly contaminated silage near the wall with that near the center. In some top feeding silos a layer of silage 3 to 6 inches thick sometimes remains against the walls of the silo and does not mix with the rest of the silage. As shown in this study, the silage nearest the walls contained the greatest residues of PCB's and if that portion of silage was discarded, it is very unlikely that contamination of the silage would be sufficient to cause contamination of the milk and meat of animals. 1S DSW 332597 STLCOPCB4079173 TABU II O N CM #--o4 w Is* at o 0u 0 e x: rv m to co m > n CO iE_ tC 0 h. fO CO o> 0 CD Cv 00 CO 0 Q Ui Cp--M4 i* 0 18 &" i c*5 W M a 0 CL. E0>l O Ho> -- -o 22 K NCM tNv ON 0c c --* cj c a27 4s-i sH --saC ec O fl N tv rv N oo o o .C OO O>- *cH "Jo T3 (0 0) a Ps in rr o m cd SC pE c *0 2 a. Ou, 0 t:, ** 9 w " 33 u cm --i 0 0^ > T3 CM > 10 u -I o -c w33 .iC *0o4 as CO o CL T3 2 c0 0 m0 -4A- 01 0 5_ 0m =3 <4-1 *2 O CMO .c o 0 K a 0 a. O J o 0> c0c oo o w oo o <7> co *r CD -- o;o CM CM CO 0) fc- p O* o <g O o a <0 $ 0) o r CO P-. CO to 0 Fh3 os ca -4 M So 3 * a -*4 0 CO O CL *4-1 0 1 CtvM I o o ao oo o CO o 0-1 o CD CO o mo o -H -4 o o tv o CM M cc L s o o o CM o rv o o ^ a cn 0 J *a 0 u L04 a J e lx uc oO CMli o o F4 ro CO o* o o u o u . Oo r-H in V4M- GB 14M-4 CM CO H a a CM tn C 4-4 o -M C .G Oo o xc oo e. e co <D oo oo 4- *2 <M u 3-H oflj xS x! o5o os o 4_| (fl o a a u E6E CO O O $ 3 <% 0 X) o 414 DSW 332598 STLCOPCB4079174 TABLE 3 Level of PCB Residues in Distilled Water and in an Aqueous Extract of Corn Silage at.Various Intervals after the Addition of Silo Wall Chips from Farm C Hours of Incubation 24 48 72 PPM Residues in Distilled water Silage extract 0.02 .03 .06 0.16 .25 .42 *1*110 chips incubated, with shaking, at 37*C. Unlike farms B and C, the silo wall chips from farm . A contained'only small amounts of PCB's and the silage was free. of.these residues. Since PCB residues had been reported in the milk of cows on farm A, it was obvious that there was another source of contamination. Further search for the PCB source on farm A revealed that the feed troughs were the contributing sources. These troughs had been coated with a sealent containing Aroclor 1254, and chips from the bottom of the troughs contained 8,000 ppm of residues. Care will be required to prevent accidental contamination of animal feed due to the large number of materials that contain PCB's and the potential of silage and other feed to pickup PCB residues. In all samples analyzed, except one, the various components of the Aroclor 1254 mixture appeared to move into and contaminate the silage in an equal manner. This indicated that there was little or no selectivity in solubility of movement of the compounds that make up the Aroclor material in the silo walls. With the one exception mentioned above, peaks E, G and L (Fig. 1) were present at twice the amount of the rest. This occurred in the sample from farm B taken 36-48 inches from the silo wall and the total residues levels were very small. It is possible that the mobility of the components of Aroclor 1254 may vary to some degree. Obviously, more information concerning the compounds in the Aroclor mixture, and other PCB-containing products, must be obtained before their toxicological significances as residues in milk and other food products can be completely assessed. References 1. Gustafson, C. G. Environ. Science and Tech., , 814-819 (1970), 415 DSW 332599 STLCOPCB4079175 2. Reynolds, L. M. Bull. Environ. Contam. Toxicol., 4, 128-143 (1969). 3. P.isebrough, R. W., Reichle, P., Herman, S. G., Peakall, D. B., and Kirven, M. N. Nature 220, 1098-1102 (1968). ' ' 4. Risebrough, R. W., Reichle, P., and Olcott, H. S. Bull. Environ. Contam. Toxicol. 4, 192-201 (1969). ~ 5. - Koeman, J. H.f Ten Noever Debrauw, M. C., and DeVos, R. H. Nature 221, 1126-1128 (1969). 6. Armour, J. A., and Burke, J. A. JAOAC 53, 761-768 (1970) . 416 DSW 332600 STLCOPCB4079176