Document qd2EmeJaKM2Zrq8YpkxzGeeDx
Jas. P. Marsh & Company
Specialties, Heating
MARSH SYSTEM UNIT THERMOSTATIC RADIATOR TRAPS
Like Marsh System Unit Valves, these traps are made in two-tone lustrous polished and satin finish in either chrome or nickel. It is the function of the Marsh System Unit_Radiator Trap, installed at the outlet of the radiator, to retain steam within the radiator until it has given' up its heat units. It is equally es sential that all water of condensate, air and gases be passed out of the radi ator into the return sys tem. This is dependent upon the sensitive opera tion of the thermostatic diaphragm within ranges where steam, water and
CAPACITIES No. 1 Series Radiatof Trap
Sizes
Sq. Ft. C. I. Raciiation
air are at temperatures varying only slightly from each other-
installed upon the radi ator it has a second impor tant function; that of auto matically maintaining the
necessary difference in pres
sure or vacuum between supply and return systems,
assuring circulation throughout the heating
system.
Marsh System Unit
Thermostatic Traps are
manufactured in two
. styles :-The Marsh No. I
Series, made in H in.
Marsh Ho. t Trap
connection size only, and
the No. 2 Series, made
in three sizes, )4, %, and 1 in. The
No. I Series is obtainable in the follow
ing patterns; Angle, Straightway, Right
'/l* z connection
ISO
No. 2 Series Radiator Trap
Sizes
Sq. Ft. C. I. Radiation
'/j* z |/)* connection z 74 connection
I* x \a connection
200 500 1000
Hand, Left Hand and Back Offset. The same patterns are supplied in the in. No. 2 Series. The % and 1 in. sizes of No. 2 Series have the following patterns: Angle, Right Hand, Left Hand and Back Offset.
The body (2) is a steam bronze casting accurately machined consists of a tinned brass screw nwitii^A ^jart spun and
and tested to 125 pounds working pressure. Modern methods sweated to the diaphragm wafer. The upper diaphragm wafer
of machining on all parts, including the body (2) and bonnet is spun and sweated to the adjustment screw assembly con
(1) are employed, gauged by micrometer scale with a toler sisting of two parts combined to form the adjustment screw
ance of .007 inches. The traps are built with renewable seat (5) and swivel When the two wafers are assembled, pro
(8) made of ahard brass screw machine part.
jection on both the upper post (5) and the valve needle (7)
The expansible portion of the thermostatic diaphragm combine to form a matched fit when the diaphragm is com
assembly consists of an upper and lower wafer oi tinned pletely compressed. An interior reinforcement arrangement
or bronze, drawn and spun to perfection of temper, (4) forms a perfect inner ring reinforcement between the
ver wafer is fastened to the valve needle (7) which upper and lower wafers. 814
Jas. P. Marsh & Company
Specialties, Heating
MARSH SYSTEM UNIT TRAPS
Marsh No. 8 Drip Trap
This trap is con
tinuous in discharge
and is designed to
quickly remove con
densation and air
from drip points on
steam mains, steam
risers, steam coils,
or blast heaters or
for any like service
within the capacity
of the trap. The design permits a deep water seal on the discharge. The thermostatic by pass member is the same as in the Marsh No. 1 Radi ator Trap. Body of trap is provided with one 1)4 in.
Capacities
Steam Pressure, lb.
Capacities Water per Hour. lb.
Vi 500 1 900 2 1400 3 1600 4 1800 5 2000 10 3200 15 4000
tapped inlet and
two 1 )4 in. outlet openings. It may be
suspended directly in the piping.
Marsh No. 12 Drip Trap
Designed for removal
of air and condensation
from short steam
mains, branches or
risers, unit heaters,
steam coils, etc. Con
densation is removed
through a float oper
ated valve located at
attmhheeothvlobaewlormdeisyso.tlsotpcaaoAtiticeinrdtbrinyeins idePreSstseuaCrema. Ipb.aciCtWHieaoapsutaercr.'iptui>ee.sr
pass in the cap of the trap. The ther mostatic member is interchangeable with the member of the standard No. 1 Radiator Trap.
Vi
2 3 4 5 10 15
350 - 600 800 1200
1400 1600 2000 2800
Equaliser and Boiler Return Trap
Marsh System Unit Air Trap
This unit vents the air from return piping of 'Marsh Vapor Systems. It also ventsair and exhaust vapor from the return trap. A ball float mechanism permits the
escape of air and prevents the leakage of water.
This trap is made in one size to handle in stallations up to 10,000 sq. ft. of radi ation.
Marsh System Unit No. 14 Heavy Duty Trap
The Marsh No. 14 Float and Thermo static Heavy Duty Trap is designed to handle very large volumes of water and air and for service on air heating coils, hot water and storage heaters, steam headers, large steam mains, etc.
Marsh No. 10 System Unit Equalizer and Boiler Return Trap
This unit, installed on Marsh Vapor Systems, performs the two functions of equalizing the vacuum between the supply and return piping and returning water to the boiler. 11 eliminates the installation of additional piping and guarantees pro tection to the boiler.. This trap is made in sizes up to 10,000 sq. ft." capacity and can be installed in series for large installations.
Capacities 1 lb. 3 lb. 5 lb. 10lb. 15 lb. ttlk 25 lb.
1900 4160 6200 8200
3260 7140 8400 M5d0
4180 5800 7100 8000 9200 9170 12000 14600 17700 19700 12000 18400 24000 29450 34800 19000 26500 34900 38400 44700
815