Document qd2EmeJaKM2Zrq8YpkxzGeeDx

Jas. P. Marsh & Company Specialties, Heating MARSH SYSTEM UNIT THERMOSTATIC RADIATOR TRAPS Like Marsh System Unit Valves, these traps are made in two-tone lustrous polished and satin finish in either chrome or nickel. It is the function of the Marsh System Unit_Radiator Trap, installed at the outlet of the radiator, to retain steam within the radiator until it has given' up its heat units. It is equally es sential that all water of condensate, air and gases be passed out of the radi ator into the return sys tem. This is dependent upon the sensitive opera tion of the thermostatic diaphragm within ranges where steam, water and CAPACITIES No. 1 Series Radiatof Trap Sizes Sq. Ft. C. I. Raciiation air are at temperatures varying only slightly from each other- installed upon the radi ator it has a second impor tant function; that of auto matically maintaining the necessary difference in pres sure or vacuum between supply and return systems, assuring circulation throughout the heating system. Marsh System Unit Thermostatic Traps are manufactured in two . styles :-The Marsh No. I Series, made in H in. Marsh Ho. t Trap connection size only, and the No. 2 Series, made in three sizes, )4, %, and 1 in. The No. I Series is obtainable in the follow ing patterns; Angle, Straightway, Right '/l* z connection ISO No. 2 Series Radiator Trap Sizes Sq. Ft. C. I. Radiation '/j* z |/)* connection z 74 connection I* x \a connection 200 500 1000 Hand, Left Hand and Back Offset. The same patterns are supplied in the in. No. 2 Series. The % and 1 in. sizes of No. 2 Series have the following patterns: Angle, Right Hand, Left Hand and Back Offset. The body (2) is a steam bronze casting accurately machined consists of a tinned brass screw nwitii^A ^jart spun and and tested to 125 pounds working pressure. Modern methods sweated to the diaphragm wafer. The upper diaphragm wafer of machining on all parts, including the body (2) and bonnet is spun and sweated to the adjustment screw assembly con (1) are employed, gauged by micrometer scale with a toler sisting of two parts combined to form the adjustment screw ance of .007 inches. The traps are built with renewable seat (5) and swivel When the two wafers are assembled, pro (8) made of ahard brass screw machine part. jection on both the upper post (5) and the valve needle (7) The expansible portion of the thermostatic diaphragm combine to form a matched fit when the diaphragm is com assembly consists of an upper and lower wafer oi tinned pletely compressed. An interior reinforcement arrangement or bronze, drawn and spun to perfection of temper, (4) forms a perfect inner ring reinforcement between the ver wafer is fastened to the valve needle (7) which upper and lower wafers. 814 Jas. P. Marsh & Company Specialties, Heating MARSH SYSTEM UNIT TRAPS Marsh No. 8 Drip Trap This trap is con tinuous in discharge and is designed to quickly remove con densation and air from drip points on steam mains, steam risers, steam coils, or blast heaters or for any like service within the capacity of the trap. The design permits a deep water seal on the discharge. The thermostatic by pass member is the same as in the Marsh No. 1 Radi ator Trap. Body of trap is provided with one 1)4 in. Capacities Steam Pressure, lb. Capacities Water per Hour. lb. Vi 500 1 900 2 1400 3 1600 4 1800 5 2000 10 3200 15 4000 tapped inlet and two 1 )4 in. outlet openings. It may be suspended directly in the piping. Marsh No. 12 Drip Trap Designed for removal of air and condensation from short steam mains, branches or risers, unit heaters, steam coils, etc. Con densation is removed through a float oper ated valve located at attmhheeothvlobaewlormdeisyso.tlsotpcaaoAtiticeinrdtbrinyeins idePreSstseuaCrema. Ipb.aciCtWHieaoapsutaercr.'iptui>ee.sr pass in the cap of the trap. The ther mostatic member is interchangeable with the member of the standard No. 1 Radiator Trap. Vi 2 3 4 5 10 15 350 - 600 800 1200 1400 1600 2000 2800 Equaliser and Boiler Return Trap Marsh System Unit Air Trap This unit vents the air from return piping of 'Marsh Vapor Systems. It also ventsair and exhaust vapor from the return trap. A ball float mechanism permits the escape of air and prevents the leakage of water. This trap is made in one size to handle in stallations up to 10,000 sq. ft. of radi ation. Marsh System Unit No. 14 Heavy Duty Trap The Marsh No. 14 Float and Thermo static Heavy Duty Trap is designed to handle very large volumes of water and air and for service on air heating coils, hot water and storage heaters, steam headers, large steam mains, etc. Marsh No. 10 System Unit Equalizer and Boiler Return Trap This unit, installed on Marsh Vapor Systems, performs the two functions of equalizing the vacuum between the supply and return piping and returning water to the boiler. 11 eliminates the installation of additional piping and guarantees pro tection to the boiler.. This trap is made in sizes up to 10,000 sq. ft." capacity and can be installed in series for large installations. Capacities 1 lb. 3 lb. 5 lb. 10lb. 15 lb. ttlk 25 lb. 1900 4160 6200 8200 3260 7140 8400 M5d0 4180 5800 7100 8000 9200 9170 12000 14600 17700 19700 12000 18400 24000 29450 34800 19000 26500 34900 38400 44700 815