J M iHstory' FILE COPy f/* *7 CRMC-SBGAB-ConduitPipe-000037 SC-GRAY-1150 This Asbestos Cement Material Formed a Fire Safe Barrier for Electrical Equipment in The registered copyright name, "TRANSITE," origi nated early in the century, shortly after Brooklyn was absorbed into the city of New York. The people of Brooklyn were then humorously called, "Trolley Dodgers," an unwitting compliment to the Brooklyn Rapid Transit Company whose service contributed to the phenomenal growth of the community. The trol ley cars of that era required a nonconductive fire barrier between the electrical apparatus underneath and the passenger carrying body. This was first made serve water, sewer and flue pipe requirements as well as public utility underground cable subway needs. The latter became the unique modern materials now known as TRANSITE Conduit (for underground cable sub ways without concrete encasement) and TRANSITE Korduct (for concrete encased cable subways). Desirable Properties of Transite Ducts Several new and desirable properties are provided by TRANSITE ducts. They do not rot or deform with age, heat or immersion. Under fire or arc, they neither burn nor fume. For a completely inorganic material, they are relatively light. Yet they perform like stone materials in their rapid dissipation of I2R Heat. Unlike Courtoty Board of Transportation: N, Y. C. of wooden boards which proved unsuitable. To over come the fire hazard, the Johns-Manville Company developed safer and more serviceable asbestos-cement sheets, known as "Transit Boards." A more distinc tive name was coined by simply adding an "E"-- hence "TRANSITE." Transite Adapted To Other Uses Since then, flat TRANSITE has been developed for such purposes as switch barriers and enclosures, bus ducts and cell structures, movable partitions, curtain walls, foundry boards, laboratory hoods and vents. These asbestos-cement sheets have also been corru gated to form TRANSITE walls and roofs. A process for making Asbestos-Cement tubes, devel oped by an Italian inventor, was acquired by JohnsManville in 1927. Using American materials as well as Yankee ingenuity and skill, Johns-Manville began improving the process and making available a whole new family of additional TRANSITE products to ducts made of ceramic materials, they are supplied with a wide variety of fittings. And, with proper tools, Transite Ducts may be field-machined to length or other requirements. These asbestos-cement ducts may be stored outdoors in tropical sunshine or arctic weather without deterioration. The unique properties of TRANSITE duct materials are due to their unusual com position and methods of manufacture: 1. Increased strength reinforcement is attained by the inclusion of millions of asbestos fibers thoroughly mixed and of random orientation throughout the wet Copyright 1953 Johnt-Manvlllo CRMC-SBGAB-ConduitPipe-000038 cementitious mass from which the duct is formed. These silky, stone fibers are only a fraction of the diameter of a human hair--but in tensile strength they are nearly comparable to equivalent sections of steel. 2. This mix is formed and compacted under uniformly constant pressure so that the tensile strength of the resultant cement bonded product is increased at least six fold over that of conventional concrete products. 3. The tube is formed of layers deposited from a uni form, accurately controlled slurry under hydraulic pressure around a highly polished steel mandrel. 4. The curing method used is one that achieves an Available in Duct Types Transite Conduit for exposed work and installation underground without concrete encasement. Transite Korduct for installation in concrete. TRANSITE MEETS EVERY REQUIREMENT OF THE IDEAL DUCT MATERIAL Permanent Fireproof Corrosion-Resi^tc Strong Light in Weight Smooth Bore Long Lengths Non-Inductive - Rapid Heat Dissipatio - insoluble calcium silicate bond equivalent to that of concrete exposed for many years to the elements. In all, the product that results is strong, light, has long, easily handled sections. It is immune to deforma tion, rotting, rusting, fire, fumes, electrolysis and either acids or alkalies occurring naturally in the earth. In underground construction, no other material offers quite so much promise of permanence as does stone-- TRANSITE products are made from several stone ingredients chosen, combined and cured to provide a cable subway which will last indefinitely, will not injure cable sheaths, and will insure low operating costs by keeping cables cooler. * MB L U 1 M \ Y CRMC-SBGAB-ConduitPipe-000039 Transite Conduit, the thicker-walled asbestos-cement duct, is designed for installation underground without concrete reinforcement. Through the elimination of concrete, it enables the installer to make substantial savings in time, labor and materials. This duct may also be installed in exposed locations, indoors and out. It has the combination of strength factors necessary to withstand all normal soil stresses. These strengths Each section of the popular sizes of Transite Conduit is 10 feet long--longer than other non-metallic conduit. This means fewer joints in the completed line . . . and those joints are rapidly assembled, using the Transite Tapered Coupling. Thus, men can often work directly behind the trencher as in the middle photo below. The savings in time that result from the use of Transite Conduit are reflected in lower labor costs and lessened interference with traffic. result from the construction of Transite in which mil lions of asbestos fibers dispersed throughout the structure reinforce the cement in much the same manner as steel. Consequently, Transite has six times the tensile strength and three times the compressive strength of first quality ordinary concrete. No Expensive Special Fittings Needed Johns-Manville supplies a wide range of standard fit tings for use with Transite Conduit. These fittings are made of the same asbestos-cement material as the ducts themselves and are machined to the same stand ard taper. These standard fittings provide maximum flexibility in laying out or constructing duct systems. Millions of feet have been installed without concrete envelope as laterals under many streets, rights of way, airfields, airports and heavy industrial yards, etc. Additional information covering these fittings is given on page 10 and in brochure EL-45A. CRMC-SBGAB-ConduitPipe-000040 Easily Cut and Machined Common tools such as a six point rip saw or a large hack saw with a chrome-moly blade will cut Transite Conduit easily and rapidly. The fastest and most efficient tools, however, are those developed by JohnsManville especially for cutting and tapering asbestoscement ducts on the job. These tools are stocked at convenient points ready for shipment. Folders giving complete descriptions are available from any JohnsManville industrial products sales office. Coniines Arc Damage When arcing occurs, incombustible Transite protects adjacent cables against heat and flame. The impinging arc will not cause the duct to sag or to adhere to the cable sheath--up to the point where the heat is intense enough to fuse the surrounding mass. Moreover, the fusion products are soft and incapable of harming the lead cable sheath when cables are thereafter drawn in or out. Furthermore, Transite cannot contribute to the formation of explosive or toxic gases. Needs No Protective Coating Outdoors Where Transite Conduit is used in exposed locations, it may be painted for decorative purposes. However, it needs no paint or periodic maintenance to protect it against the weather even along the coast, in railroad yards or in similar areas where it is subject to corrosive atmosphere or gases. In exposed locations, it often out lasts competing duct materials many times over. Transite Conduit is attractive in appearance, stays at tractive and may easily be cleaned. Minimizes Replacements in Corrosive Soils The asbestos-cement composition of Transite Ducts is highly resistant to corrosive attack whether from alka line or acid soils. These ducts stand up in corrosive cinder fills, salt marshes and other troublesome soils. Being non-metallic they are immune to galvanic action, or electrolysis. Transite Ducts outlast other types of duct materials even when corrosive action is accentu ated by shock and vibration. CRMC-SBGAB-ConduitPipe-000041 Transite Reduces Replacements in Railroad Applications At lost report, these Transite Ducts were still on the job after I 8 years exposure to smoke, corrosive fumes, and vibration. Shown above is an example ofhow Transite Conduit conveniently because Transite Conduit cannot sag outlasted ferrous duct materials several times over. and will not adhere to the cable. Transite can In this exposed installation, the Transite Conduit is not contribute to the formation of explosive or i"b- subject to flame, sparks, corrosive gases, and toxic gases. K: weather. The effects of the vibration and shock Simple Transite Systems in from traffic on the bridge are cushioned on resilient Residential Areas Afford r rubber rings provided by J-M Transite Conduit expansion couplings for such constructions as this. Underground Service with The duct requires no painting or maintenance. Moderate Installation Cost A Transite Conduit System (shown below right) % Utilities Obtain Superior Arc with large diameter Transite Service boxes provides Protection most of the flexibilities and conveniences of a con ventional cable subway and eliminates unsightly A well known public utility installed this Transite and vulnerable overhead wires. Particularly in Conduit bank (below left) without concrete encase suburban or other areas of uncrowded land occu ment. If cable failure occurs, the non-combustible pancy, such a system provides a single 4" Transite Transite will safeguard adjacent cables against heat Conduit for power service cable to surprisingly and flame. The damaged cable can be withdrawn large areas at reasonable cost. CRMC-SBGAB-ConduitPipe-000042 CABLES RUN COOLER SZ'lr*' "'W ,, ""ife. sSSsS^sr JftssKSt MV H ^9 H EE ) ZJjTvi, j"ktfc,l AIEE Paper 50-55. AIEE Trans actions Volume 69, 1950. Available without charge from the Electrical Department of Johns-Manville, 22 East 40th" " " ' '' XT v ri^1* Hi IU*" ''terLjfcf MB*** * **i. yj.'f *w, *6J".<.r.TVV"?t6-."-.'J"'"TMBa'*t-.* TT' vTirr^f Vj^ HOW TRANSITE DUCTS I. INCREASE CURRENT CARRYING CAPACITY II. YIELD DOLLAR SAVINGS TRAN5ITE INORGANIC DUCTS I. Total Therm. Res. to Dielectric Loss (thermal ohms) 5.61 ORGANIC DUCTS 6.03 2. Total Therm. Res. to Copper Loss (thermal ohms) 4.21 4.62 3. Temp, rise from Dielectric Loss (C) 1.9 2.1 4. Allowable rise for Copper Loss (C) 59.1 58.9 5. Allowable watts for Copper Loss per ft. cable 4.70 4.25 6. Allowable Current--(Amps per cdr) 398 378 7. Allowable Current--(Relative %) 105.1 100 8. Greater heat carrying ability of Transite (%) 9. Watts loss per foot at equal currents: 10. Savings in (watts/ft.) losses Oganic Duct Transite with Transite 1 1. Annual dollar savings @ $20/KW per M ft. 12. Annua! greater charges for Transite per M ft. on basis: 1 '/s ducts per cable Diff. mat. cost--$.04/ft. Carry. Chgs.--Int. 6%, Taxes 2 Vt% Depr. 1%; Total 9 13. Net annual savings with Transite $ per M ft. CONDITIONS: Cab/e--3 Cdr. 500 MCM Compact Sector, 1 75 mils paper, 1 25 mils lead 1 5 KV grounded neutral (8th Edition AEtC Spec.) Theoretical Cable Diam.--2.52" Due/--2 x 2 bank, 3 loaded, 4'ducts, 6 iV'spacing, 30' earth cover, 3* Concrete around ducts. Concrete-Soil Resistivity-- 84 (watt*cm). Load Factor 75%--Loss Factor 62 Vi%. Earth ambient 20C. Lower l2R Losses, Increased System Capacity Longer Insulation Life Usually Result The figures given in the table above should interest every distribution engineer because system losses are still a major expense of the electrical power in dustry. This sum is estimated to be more than four hundred million dollars annually for the United States. It is generally agreed that system losses can be reduced by improving the dissipation of heat from conductors under load. The figures in the table are based on a paper approved for presentation by the AIEE Insulated Conductor Committee*. This paper reports test conducted for many years by the Johns-Manville Research Center to determine accurately how Tran sire Ducts improve the dissipation of heat by conductors under load. The results of these tests prove that Transite Ducts will carry heavier current loads than organic ducts when the sheath temperatures are the same. This means that cables installed in Transite Ducts can carry heavier loads at peak conditions than the same cables installed in organic ducts. It also means that when a conductor is under a given load, its temperature will be lower when it is installed in a Transite Duct than when it is installed in an organic duct. The lower temperature of the conductor results in a lower electrical re sistance with correspondingly lower I2R losses. The economic result of the reduction in I2R losses depends, of course, on the monetary value per KW. Theoneselected forthetableis considered reasonable. Lower operating temperatures can also prolong in sulation life, resulting in more reliable service and longer cable life. All these savings--plus the other advantages of Transite Ducts--furnish more than ample economic justification for their use. CRMC-SBGAB-ConduitPipe-000043 TRANSITE KORDUCt Transite Korduct Protection Can Outlast Amortization Period Transite Korduct, the thinner walled Transite Duct was developed particularly for installations where concreting-in is required--in main line cable subways and in masonry structures. Transite Korduct is proportionately as strong as Transite Conduit and maintains its strength in service. Transite Korduct is also corrosionresistant, immune to electrolysis and galvanic action. It cannot rot or rust. It is as permanent as stone because its ingredients are stone in origin--asbestos, cement and silica. No other duct material offers so much promise of permanence. Therefore, Transite Korduct can nor mally be expected to protect cables long after its cost has been amortized. Can Carry More Cable Per Cross-Sectional Unit As shown at right above, Transite Ducts are unlike other ducts in that the wall itself is a fireproof barrier because of its asbestos-cement con struction. This property of Transite can be utilized to reduce the separation between ducts. The closer spacing accomplishes two things: (l) it provides a saving in concrete, (2) it permits the bank to be designed so that a greater number of cables are carried per unit of cross-sectional area. This desirable property of Transite Korduct has been utilized advantageously by many designers of cable subways. Affords Greater Protection Against Fire Despite modern precautions, the burn-out is still a potential hazard. Consequently, cables should have the protection that Transite Ducts provide. Transite Korduct, like Transite Conduit, confines burn-outs, safeguards adjacent cables from damage and reduces the possibility of panic and explosion. Made of incombustible asbestos and cement, Transite Korduct will not burn, smoulder or generate smoke or fumes. This duct material cannot contribute to the formation of explosive gases. The fireproof protection of Transite's asbestos-cement construction is vitally necessary in loca tions,such as subways, tunnels, and power plants. CRMC-SBGAB-ConduitPipe-000044 Lower Installation Cost Results From Longer Lengths Like Transite Conduit, this asbestos-cement duct is available in 10 ft. long sections--longer than those of any non-metallic duct. These extra long lengths require fewer joints. Hence installation is faster because less time is required for joining successive lengths. Also, in the case of the tier-by-tier method there is a reduction in the time for positioning and removing separators. Furthermore, in the monolithic method, fewer spacers are needed. Instructions for installing Transite Ducts are given in folder EL-43A, available from the nearest Johns-Manville Sales Office. $& Cables Move Freely in Transite Korducf The unusually smooth bore of Transite Ducts prevents injury to the cable sheath, either in natural movement under load or when pulling cables. Furthermore, the interior of the duct remains smooth in service because Transite resists heat and flame. The heat of an arcing cable cannot cause the interior of Transite Korduct to adhere to the cable sheath. Nor will it slag under the heat and flame of an impinging arc though some slight flaking may occur. This however will not damage the cable sheath or interfere with the pulling of cables. Used By Beth Fewer and Communication Systems While Transite Korduct is widely used by large power plants to shield power and control cables and for utility installations in urban areas, its use is by no means limited to this class of conductors. It is employed throughout the United States by telephone companies and by munici palities for communication and signaling systems. CRMC-SBGAB-ConduitPipe-000045 ,, mtiMS ____ _ *p~~ 'l-W TRANSITS FITTING: Standard Transite Fittings are available in wide variety to provide maximum flexibility in laying out or constructing a duct system. These fittings are made of the same asbestos-cement material as the ducts themselves and are machined to a standard taper so that they can be used with Transite Conduit, Transite Korduct or with other Transite Fittings. for joining ducts Topered Coupling joins tapered ends of duct. One furnished with each duct length. Duplex Adaptor joins a tapered end to an untapered end of same duct site and type. Many unusual radii bends or sweeps can be made by using standard Transite Double Duplex Adaptor joins two untepered ends of same duct i fittings. For instance, the new 5 degree Bend Segment alone can form a wide size and type. variety of different curvatures in any multiple of 5 degrees. Used with other Straight Adaptor joins various or i Transite curved fitting in various combinations, it can form curvatures of same types of duct of same size. Reducing Adaptor joins various odd degrees. Thus, users can clear unexpected obstructions, accommodate types of ducts of different sixes. layout revisions and simplify cross-overs and transformations. Expansion Coupling provides for In addition to the many fittings for facilitating direction changes, other movement due to expansion, con traction or vibration. fittings are available. There are fittings for making terminal connections, for joining Conduit, Korduct and other types of ducts in same or different sizes ... to provide for movement due to expansion, contraction or vibration . . . for making terminal connection: End Bells (Standard, Junior and Expansion) designed to protect to join duct runs ... to facilitate cable pulling at various points in the line. cables from abrasion. These fittings are covered more fully in Folder EL-43A, Instructions for installing Transite ducts and EL-45A Dimensions and fittings for Transite ducts. Terminal Box Bell and flanged Connector for terminating duct ....lines at metal or wood boxes. TRANSITE TAPERED tOUPUNCS (left) moke it easy to ropidly assemble successive lengths of Transite Ducts. Machined on the inside to fit the standard taper of the duct end, they form a silt-tight Flexible Connection to protect ducts attached to fixed struc tures from undue shear. for directional changes Bends--45, 90, and offset; Curved Segments 11'^0 and 22Vj; Sweeps--12' 6" R, Deflec tion Couplings -- 5s*5 Bend Segments (male taper on one end, female taper on other). Ckk faoi mtmctibnA faoi INSTALLING TRANSITE DUCTS Miscellaneous fittings Center Make-Up Connector joins two duct runs laid from opposite directions. Conduit Pull Sleeve provides on open space in a Transite Conduit run. Also: Pole Riser Cap, Cap, Plug, Elbows, Tees and Laterals. CRMC-SBGAB-ConduitPipe-000046 There is a Johns-Manville Sales Office Near You Nearly every city of substantial size has a Johns-Manville Sales Office, which in turn is serviced by a District Office located in the major city of its industrial area. This means that you get personal service from sales representatives and engineers who can help you obtain better cable protection. Other Booklets Cov ering J-M Electrical Products Available TRANSITE DUCT UNDERGROUND INSTAL LATION SHEET -- EL-43A. A 6-page folder which tells how to assemble Transite Tapered Couplings; cut, ma chine and install Transite Ducts. Contains "Hints and Aids," Table of Offsets and illustrations of various Transite Fittings. FITTINGS AND DIMENSIONS OF TRANS ITE DUCTS --EL-45 A. Contains all available dimensional data required by the designer laying out a duct line. Also contains a Table of Off sets for various Transite Fittings. Akron Albany Atlanta Baltimore Birmingham Boston Buffalo Charleston, W. Va. Charlotte Chicago Cincinnati Cleveland Columbus Corpus Christi Dallas Dayton Denver Detroit Erie Fort Wayne Grand Rapids Honolulu, T. H. Houston Indianapolis Jacksonville Kansas City, Mo. Knoxville Lake Charles Los Angeles Louisville Milwaukee Minneapolis Newark (East Orange) New Orleans New York Oakland Omaha Philadelphia Pittsburgh Portland, Me. Portland, Ore. Providence Richmond Rochester Saginaw Salt Lake City San Antonio San Francisco Seattle South Bend St. Louis St. Paul Syracuse Toledo Tulsa Washington Wilkes-Barre Youngstown JOHNS-MANVIILI PRODUCTS PLASTIC SPACERS SHEET-EL-41 A. De scribes and gives, dimensions of new lightweight plastic spacers devel oped to position Transite Korduct in monolithic concrete encasements. J-M PLASTIC, FRICTION AND RUBBER TAPES--EL-35A. Our new all-purpose JOMANCO PLASTIC TAPE and other high value electrical tapes are de scribed in this folder. ' TRANSITE CABLE TRAYS folder. Dimen sional and installation data includ ing types of supports and fastenings. Canadian Johns-Manville Co., Ltd. Montreail Toronto Vancouver Winnipeg Johns-Manville International Corp. New York London Buenos Aires HOW TO INSTALL TRANSITE CONDUIT IN EXPOSED LOCATIONS. In preparation. El-29 A Printed in U. S. A. CRMC-SBGAB-ConduitPipe-000047 AFFIDAVIT STATE OF COLORADO COUNTY OF ADAMS ) ) ss. ) I, Margaret J. Baumgardner, being of full age and first duly sworn do hereby state: 1. Iam not a party to this action. I have personal knowledge ofthe facts set forth in this affidavit, and if called as a witness, I could and would competently testify as to the truth of the matters set forth herein. 2. I am the Research Coordinator for the Claims Resolution Management Corporation ("CRMC"), a wholly owned subsidiary of the Manville Personal Injury Settlement Trust ("Trust"). The CRMC was created in December 1998 and is staffed by former Trust employees. On January 1, 1999, CRMC began providing claims resolution facility services to the Trust. 3. In this position, I manage the Asbestos Claims Research Facility ("Facility"), a document and records repository located at 3390 Peoria Street, Suite 304, Aurora, Colorado. The Facility contains the business records including but not limited to correspondence, memoranda, reports, records and data compilations ("record") of Manville Corporation or related entities ("Manville"), generally, as well as Manville records relevant to litigation of asbestos liability. The Trust has managed and operated the Facility from November 28, 1988, the date on which the Manville bankruptcy plan was consummated. 4. My experience and familiarity with the documents at the Facility began in 1983 while working for Manville. In my work as a paralegal for Manville, I assisted in locating, indexing and packing many ofthe records which became the foundation documents for the Facility. I continued to work for Manville until September 1987. From March 1988 to September 1988,1 was hired to supervise and assist in the indexing ofthe first 20,000 boxes which were turned over to the Trust in November 1988. From September 1988 to January 1989, I assisted in the privilege review of documents to be given to the Trust. From November 1988 to April 1994,1 worked for Freeborn & Peters and was put in charge of the Facility, managing all productions and "new" acquisitions. In September 1995,1 was hired by the Trust to manage the Facility. In December 1998,1 was hired by Page 1 the CRMC to manage the Facility for the Trust. Accordingly, I am personally familiar with many of the records stored at the Facility, as well as how the records have been gathered. 5. To the best ofmy knowledge, information and belief, I certify that these records were made at or near the time by, or from information transmitted by, a person with knowledge, were kept in the course ofthe regularly conducted business activity of Manville, and it was the regular practice and the business activity of Manville to make the records. 6. Attached are documents found among the file and microfilm box collections at the Facility. These documents, bates labeled CRMC-SBGAB-ConduitPipe-000001 through CRMCSBGAB-ConduitPipe-000092, are true and correct copies of documents found at the Facility. Subscribed and sworn to before me this 16th day of May, 2014. AMYWBENHAM NOTARY PUBLIC STATE OF COLORADO MY COMMISSION EXPIRES 05-23-2016 Page 2