UNION CARBIDE CORPORATION n o box av i . te_xass ci ry. texas 77590
HEALTH, SAFETY AND ENVIRONMENTAL AFFAIRS
July 23, 1984
Mr. Clayton Smith Compliance Section Texas Air Control Board 6330 Highway 290 East Austin, TX 78723
Subject:
Request for Change in Method of Compliance with Part61, NESHAPS Regulation for Vinyl Chloride Monomer Control, Sources Following VCM Strippers, -- Additional Information in Support of Request Letter dated May 25, 1984
Dear Mr. Smith:
This is in response to your request for a written explanation of the earlier reported exceedances of the stripped varnish (copolymer) samples from the semiannual reports required by 40 CFR, part 61.70 (c)(2), (continuous stripping).
You had asked for an explanation for the Ati values greater than 400 ppm that were listed in reports of our operations in 1978, '79, '80 and 1981. These are listed in the attached Table I. We began submitting these semiannual reports beginning with the period September 1978 thru February 1979.
A review of the information we have on our stripping operations at those times indicates that the high values were associated either with startup or shutdown conditions on the various polymerization systems. The autoclaves are normally operated in a continuous mode with varnish circulation as well as internal agitation, plus balanced feed and discharge flows. During start-up and shut-down procedures, the degree of monomer conversion to polymer changes and non-uniform mixing could result in variable varnish compositions being fed to the strippers. These variations could upset the equilibrium conditions in the stripping stills (which have no mechanical agitation) and could be reflected in samples taken at that time.
However since 1982, as indicated in my request letter of May 25, 1984 under the section entitled Process Improvements, we have made several significant changes that give much better control of the polymerization of the VCM which results in higher conversion to copolymer and thus less residual monomer remains to be stripped out. Please refer to that section of my original letter.
v)cc
0508^0
Mr. Clayton Smith July 23, 1984 Page 2
That these changes have been successful is reflected in the improved lower levels of A^i in the past three years, as related in the Historical Data section of my request letter. We firmly believe that now we have a much better control of the polymerization with these improvements and that the earlier exceedances are not likely to recur.
Should you have any questions about this or need additional information, please call me.
Very truly yours,
JFE:IR Attachment Cc: Ms. Victoria Wang
TACB/Bellaire TSVRVCM3
'J. F. Erdmann, P. E. Environmental Protection
Coordinator (409) 948-5126
ucc
050891
Mr. Clayton Smith July 23, 1984 Page 3
Bcc:
J. B. Leverton/S. J. Footer NESHAPS (VCM) File R. C. Wise - 500 G. F. Tacquard/S. A. Dickerson S. M. Norwood/D. R. Hall M. E. Eisenhour R. M. Arnold W. p. Nickles
TABLE I LISTING OF VCM EXCEEDANCES FROM REPORTED VARNISH STRIPPING OPERATIONS, SOLUTION VINYLS UNIT, TEXAS CITY
Reporting Periods with Dates of Individual Exceedances:
I. Semi-Annual Report for Sept '78 thru Feb '79 (168 days of operation)_______________________
Oct 17, 1978 Nov 4, '78 Dec 17, '78 Jan 6, '79 Jan 16, '79 Jan 20, '79
405.1 ppm 1020.4 1272.9
611.7 726.1 537.8
II.
Semi-Annual Report for Sept '79 thru Feb '80 (182 days of operation)________________________________________________
Sept 4, '79 Jan 4, '80 -
596.7 612.0
III.
Semi-Annual Report for Sept '81 thru Feb '82 (122 days of operation)________________________________________________________________________
Oct 18, '81 -
794.9
There were a total of nine exceedances since the start of the sampling and analytical program on Sept. 18, 1978 thru February 28, 1982, a total of 1177 operating days.
This amounts to 99.2% of the total operating days that our unit has been in compliance for this period, before the process improvements were made.
Since Mar 1, 1982 to date there have been no exceedances of the 400 ppm Ati limit.
TSVRVCM3
ucc
050893