Document qadVgmYmLX0VKp9wN8ZQB9mbk

u/a'. Not Applicable. U-S. DEPARTMENT OF LABOR Occupational Safety ahd Health Administration. MATERIAL SAFETY DATA SHEET D (%D Form AtifonB OM N*. M1MT PLAINTIFF'S EXHIBIT Required under USOL Safety end Health Regulations for Ship Repairing, - Shipbuilding, and Shipbreaking (29 CFR 1915, 1918, 19171 SECTION 1 MANUFACTURER'S NAM* EMERGENCY TCLCFHONC NO. Garlock Inc. (315) 597-4811 aooressJNumbv%Stri*t. P*y> Suit, titd ZIP Codt) Iooo Division Street. Palmvra. CHEMICAL NAM* ANO SYNONYMS N/A New Yrirk 1447? TRAOENAME ANO SYNONYMS Style 7005 CHEMICAL FAMILY FORMULA *-------- _________________________Hza________________________________ JUA-------------------------------------- --------------------------------------------------------------- SECTION II HAZARDOUS INGREDIENTS FAINTS. PRESERVATIVES. 4 SOLVENTS PIGMENTS * TLV (Units) ALLOYS ANO METALLIC COATINGS N/A BASE METAL CATALYST N/A ALLOYS VEHICLE SOLVENTS AOOITIVES OTHERS N/A N/A METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX N/A OTHERS N/A HAZARDOUS MIXTURES OF OTHER LIQUIDS. SOLIDS. OR OASES Style 7005 contains in excess of 80% of Chrysotile (White) Asbestos. The asbestos is bound and encapsulated bv an X TLV (Units! N/A N/A N/A N/A M /R X TLV (Units) elastomeric binder so that qeneration of free or dust is negligible and well below the OSHA Std. for SECTION III PHYSICAL DATA 801 UNO POINT (P.) N/A SPECIFIC GRAVITY (HjO-l) N/A VAPOR PRESSURE (mm H$.) VAPOR OCNSITV <AIRl) SOLUBILITY IN WATER N/A PERCENT. VOLATILE BY VOLUME OB) * N/A EVAPORATION RATE Ml I) isoluble N/A N/A appearanceano ooor Pale grey--cream co. Lored sheet or gasket - slight char* SECTION IV FIRE ANO EXPLOSION HAZARD DATA FLASH POINT (Matnoe WM4I N/A FLAMMABLE LIMITS N/A Lat UM extinguishing mcoia Water, foam, carbon dioxide, dry chemical. special fire fighting procedures . None, when fire involves larcre quantities of product. self contained breathing apparatus would be desirable due to smoke produced. :ty^>"^^u^mTc^i^oke when large quantities are burned. FAGE.(I) (Continued on reverse side! TX FINER RMC0039289 Form OSHA-20 Sn. Mb? 71 sprite * SECTION V ..HEALTH HAZARD DATA Thrcs^lo UMIT value tf/A Ul UlB Sheet.-----TOITlitterdslieaLUS fillBlgT-----WPL UlUie than 2 fibers longer than 5 micrometers per cubic centimeter of air. FFECTS OP OVEREXPOSURE ___________________________________N/A to the sheet.__________________________- EMERGENCY ANO FIRST AIO PROCEDURES N/A tO the Sheet. SECTION VI - REACTIVITY DATA STABIUTY UNSTABLE CONDITIONS TO AVOIO STABLE Direct flame will ignite elastomer compouii incompatabiuty {Materials to mo*) Avoj^ storage with strong oxidizing agents. HAZARDOUS DECOMPOSITION PROOUCTS . . Caroon monoxide under certain circumstances. There mav be others pnfcnoiSfn CONDITIONS TO AVOIO to us HAZAROOUS MAY OCCUR POLYMERIZATION WILL NOT OCCUR None SECTION VII - SPILL OR LEAK PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLEO No special action, wasteoisposalmethod flormai landfill; place waste in plastic bag to reduce generation of asbestos fiber to a minimum. (See Attached Sheet) 1 SECTION VIII - SPECIAL PROTECTION INFORMATION respiratory protection (Specify type} mo special requirement. Moutn ana nose masx mav be worn when_rntfimr lamp rmanl-ifipii___No__If n nun DOWS rarmiramopf^ VENTILATION localEXH^>*TSpecia requirement. SPECIAL .N. one.* wecHANicA^crg^ciai requirement. OTHER ,,Non_e. PROTECTIVE GLOVES ^ requi*ed. OTHER PROTECTIVE EQUIPMENT Not rpqii i red. eye protection as generally good prac- t ire .___safety rrlaageg mav he worn_____ "" " SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING ANO STORING Store in clean, dry place away fronj strong oxidizing agents. wwssriis0f13onded by elastomer compound, however, do not misuse by imoroper cutting or handling. See OSHA Regula- 1-ons (290iK, Paragraph lylu.iuull^,. ms*t The information furnished herein is accurate to the Rr.My7a best of our knowledge, but no warranty, express or implied, is made Prepared by: - --................ s-r oeniOJf -CheffiTSC--' TX TINER RMC0039290 2/2/82 Colt Industries Giriodt Inc Mechanical Packing Division 1666 Division Strsst Palmyra. Now York 14522 315/597-4611 December 18, 1985 Corpus Christi Gasket Attn: Dave P.0. Box 4074 Corpus Christi, TX 78408 Dear Customer: . This is in response to your, request,-f05. .a Material Safety Data Sheet for Garlock Style: _ ~7fl03y With regard to the status of style 7005 under the OSHA Hazard Communication Standard (29 CFR 1910.1200), is our position that style 7005 falls in the category of "Articles" and as such is exempt from the standard. it Additionally, we consider Garlock Style 7005 to be nonhazardous under normal conditions of use. If you require additional information or clarification, please advise. ' Attached please find an OSHA 20 Material Safety Data Sheet (or an equivalent) covering this product. Sincerely, K.uru saromon Supervisor, Safety/Security/Medical Attachment **Please keep cover letter attached to MSDS. KS:at TX TINER RMC0039291