Document qaVz4pVrrmE9mzDGdr0ZjmVaK
raftRAW* P-9
TOXICITY & SAFE HANPLINO INFORMATION
Extensive animal experimental work haa been done on Pydraul
P-9. In the case of oral feeding* it was found that the
minimum lethal dose for rata wad 10.6 to 15.8 grams per
kilogram of body weight. In rabbits the oral MLD was
O.57 to O.85 grams) in both cases the undiluted material
was introduced into the animal stomach by means of a rubber
tube catheter.
.
Pydraul F-9 was patoh-tested full strength according to the method of Schwartz and Peck, which is the standard test for
industrial chemicals. Two hundred and five volunteers were tested and there was no evidence of primary skin irritation
or sensitization.
The material was tested for its vapor phase toxicity by exposing animals to saturated atmosphere concentrations in suitable chambers. This part of the investigation involved
not only the vapors of Pydraul F-9 itself but also experiments where the fluid was dropped on Inconel surfaces heated to 1050F. and 1250F. In all oases the toxicity was roughly comparable to that of petroleum-based hydraulic fluids as far as short-term massive exposures are concerned.
When splashed or sprayed into the eyes, Pydraul F-9 causes
burning and smarting; however, there have been no reports of lasting damage. In treating eye Irritation following introduction of Pydraul, copious and prolonged washing is
recommended. To relieve the Irritation, physicians have used 1$ pontocalne solution as well as opth&lmic cortisone acetate
solution.
Regarding the effect of Pydraul F-9 on workers, we have not experienced any injuries during its manufacture. We advise in safe handling that following prolonged or repeated skin
contact, the material be washed off and that the material be kept out of the eyes. If prolonged contact with the decomposi tion products at elevated temperatures should occur, respira
tory protection is neoessary. For short periods such as would ooour in turning off a machine following a breakdown, no such
protection is necessary.
osw 009474 STLCOPCB4001197