Document qaNvvM71KMBEoXbqMnXQo3Ejx

Monsanto FROM (NAME ft LOCATION) E. M. Emery/G. M. Gasser - Technology Dept. S. 2nd St. - St. Louis ; September 27, 1971 cc: R. H. Munch - Res. 2 R. E. Keller - Res. 1 , BIPHENYL IMPURITY ANALYSES R. W. Blowers - WGK J. R. Savage - GO REFERENCE 0. DeGarmo - Res. 1 J. F. Quinn - Res. 1 TO : Edward Stewart W. R. Richard - GO W. G. Krummrich Plant" J. P. Mieure - Res. 2 M. W. Dietrich - Res. 2 E. S. Tucker - Res. 2 We have carried out trace impurity analyses by capillary column gas chromatography on the fifteen biphenyl samples made at Anniston and from which WGK Aroclor was produced. The results are given in the accompanying table. It is hoped that these will correlate with the thermal chemical chloride test on the resulting finished Aroclor products. We evaluated several GC columns for this analysis and found that a 100 foot Apiezon L S.C.O.T. (support-coated open tubular) column gave the best resolution and sensitivity. It showed the largest number of resolved impurity peaks in biphenyl. The peak identifications were made only from retention times of known compounds. If any certain components including the unknown ones correlate with the TCC test., then further work via tandem gas chromatography/mass spectroscopy can be done to confirm the identity of the impurities of interest. Please contact Martin Enel. gSXN *>6786 STLCOPCB4066699 STLCOPCB4066700