K EWAN EE
0 SQUARE'HEAT'
This new steam generator is ideal for office and store buildings, schools, motels, hospitals, small factories, apartments and other build ings of medium sire.
Intensive research, added to nearly a century of boiler experience, produced this modern Square-Heat Generator with amazing com pactness, plus highest efficiency, plus Kewanee Time-Proved structural features.
The secret of this remarkable design, which results in highest efficiency, top-quality per formance, and long dependable service, is... exceptionally high proportion of primary (direct) heating surface which is many times more efficient than secondary (indirect) heat ing surface ... plus... extra large furnace volume for complete combustion, smooth starts, clean firing, quiet operation, unre stricted gas flow and low heat release.
The entire unit is listed by Underwriters' Laboratories, Inc.
24349
O 0 ?/1
\ ; V ^ ) 1 I =>. -5 =\ 0 1J ! i t V p' 3 JYi' U r? ?' ^
THREE PASS DESIGN
Assures maximum heat transfer with low stack
_...... ^-5
temperature ... highest operating efficiency. The large firebox with arched upright crown sheet provides thorough mixing of fuel and air... complete combustion before hot gases enter fire tubes. The second pass is rear to front
through the direct fire tubes . the third from front to rear in the return tubes. Gas travel is longer and there are no refractory baffles to burn out and permit short circuiting of gases
h AJMEtfCAR rTAM0A*0 Ik
HIGH EFFICIENCY HEATING SURFACE
4Primary heating surface (exposed directly to the flame) is to 15
times more effective than secondary heating surface (exposed only to hot gases). The Square-Heat Generator design utilizes nearly 50% greater ratio of primary to secondary heating surface than com petitive units. Square-Heat Generators provide MORE more effective heat transfer surfaces, and LESS less effective heat transfer surfaces.
LARGE FURNACE VOLUME For complete combustion with smooth starts. .. dean firing . .. unrestricted gas flow ... quiet operation ... heat release averages 50% less than competitive units.
FORCED-DRAFT OPERATION Provides ample combustion air for stub stack applications. Only a vent to the outside is needed. Special assemblies available for high attitude installations.
StrtCM product Impro'vwmwrtt ii continuing ffort 1 Amnc*n St*nd*fd.
MORE ENERGY PER SQUARE FOOT
OF OCCUPIED FLOOR SPACE THAN ANY OTHER COMPARABLE UNIT
COMPACT
This Kewanee is the most compact generator you can buy. For example, you can have 80 hp in 42.7 square feet of occupied floor space. Two principal competitive 80 hp generators require 72.7 square feet and 78.0 square feet, respectively. The illustration above shows the contrast. Head room also is minimum.
LARGE STEAM SPACE Combined with abundant, unbroken disengaging area and ample water content assures steady water line and a plentiful reserve of dry steam.
TUBES ROLLER EXPANDED Ml tubes are secured to tube sheets by roller expander--none are welded to tube sheets.
WELDED STEEL
'
Flange quality plate. All welded integral construction for strength and durability. Gas tight throughout
SKID TYPE BASE Refractory filled, provides ventilation under the unit and distributes weight evenly.
"----|----- | . - .
or mineral Bbertnsulatl<mnjWl^1|4^^'5^
d to make rvMonabt* chan|tt of #rry kind artthot/t node*.
WATER HEATING COILS Standard Kewanee "Kl" (instantaneous) and "KT" (tank)) coils available for all units. Coil opening at front of boiler avoids inter ference with controls, wiring or breeching.
EASY ACCESS TO TUBES Steel flue access cover with insulation securely keyed in place pro vides easy access to flues without disturbing fuel burning equipment
TESTED-APPROVED ASME Boiler Construction Code requirements have been followed to the last detail... and the Kewanee name assures design and performance above and beyond any code requirements. These gener ators have Underwriters' Laboratories listing.
COMPLETELY ASSEMBLED
With burner and all accessories--may be moved in by fork truck,
hoist, or rollers. Only service connections are needed to nlf unit
in operation.
24350
3
KEWANEE*
BURNER FEATURES
Kewanee Square-Heat Generators are available for oil, gas, or combination gas-oil firing. Each Kewanee Forced Draft Burner is custom engineered for the generator it fires, assuring long, dependable and economical service.
Two series of Kewanee Forced Draft Burners cover the entire range of boiler capacities and fuels.
The Kewanee KR Burner fires light oil (No. 2 CS12-48), gas, and combination gas-light oil in Units M-45 thru M-265. The oil burner is of the high pressure mechanical atomizing type, and the gas burner is of the multiple jet flame retention type.
Units M-45 thru M-175 with the KR burner feature on-off operation (with low fire start on oil-fired Units M-135 thru M-175). Combustion air is regulated by a fixed position damper in addition to an adjustable primary-secondary air shutter.
Units M-205 thru M-265 with the KR burner feature on-off operation with con trolled low fire start. Fuel and air supply are regulated for both high and low firing by a two position motor. This provides smooth starting and top efficiency.
The Kewanee Burner (Pressure Atomizing) fires light oil 1N0. 2 CS12-48 >, gas, and combination gas-light oil in Units M-335 thru M-505. The oil burner is of the high pressure mechanical atomizing type, and the gas burner is of the flame retention type.
The Kewanee Burner (Air Atomizing) fires No. 5 or lighter oil, gas, and combination gas-oil in Units M-335 thru M-505. The oil burner is ot the low pressure air atomizing type, and the gas burner is of the flame retention type.
Units M-335 thru M -505 with the Kewanee burner feature full modulation with proved low fire start. Fuel and air supply are regulated throughout the firing range by a modulating motor controlled by a boiler mounted pres sure or temperature modulating potentiometer.
24351
n
MAXIMUM SAFETY
Dull automatic main gas valves (on units over 1000 MBh input) provide added protection. Boiler passages are purged of combustible gases before and after each firing cycle. Combustion is continuously monitored by an electronic flame safeguard.
CONTROL CABINET
Programming and flame safeguard relays, switch ing relays, motor magnetic starter lif required;, numbered terminal strips, indicating lights for major operations, and fuel selector switch-all mounted and wired in a heavy-gauge steel con trol cabinet mounted on the boiler unit. Wiring is ready for connection to a source of power.
AIR-OIL UNIT
The air-oil unit assembly of the Kewanee burner includes air compressor, oil pump, valves, belt drive, motor, and all necessary accessories to provide the fine oil atomization required for clean, efficient oil firing. A thermostatically con trolled electric oil heater maintains uniform oil temperature to compensate for varying viscosi ties of residual oils The multi-louvered air pro portioning damper provides accurately measured
) air supply to match fuel supply for top operating efficiency at all firing rates.
24352
5
6 24353
ftabnc-Hth................
--NirMmr -Stun ft) kwi-lin --Sltam (frets Output) . --Slcam (MCA net) .
lbs.
U It ae ft.
Finnf rate-Gas 1.000 Blu/cu. tt . -N MM00 Ita/pl .. -Oil 150,000 Btu/pl .
Meatinf wrlece-Telal
M tt
--Primary
M IL
furnace volume
..
CD tt.
Safety *atve ctpacity-Stoam pet hr lbs
Approi pry watfht
lbs
I*i
4S0 134
404 1.173 1.4)0
330 14 4
3*7 2.ni 1.723
430 10.4
670
2.701 2.036
740 22.4
773 3.17S 2JO
ISO l 244 IT* 1 3.9SI : 2.976 '
1.130 34.4
1.1K | 4.712 3.603
1.330 40.3
1J42 ' 5.625 4.230
1J40 J
IJN 1 6.4SI 4JS5
1.730 I
42J 1.104 1ZK i
S.463 :
2.040 41.2
2.111 6.642 4.422
uso 70.0
2.421 0.2*1 7J42
63 4.0
"
U i#
430 .too
Ml 4.1
-
71 21.1 1.1 550 2,050
113 . " VI 4.7
--
02 23.2 105 430
2.200
107 25.4 11.7 7SQ 2.350
l.ioo | 15
-1
127 j 30.1 134 ISO i 2.400 :
1.436 1 10J
-1
144 < 34 2, 17.0 uso ; 2.030 l
1.403 , 12.1
-1
160 37.6 204 USO 3.300
u 2.100 i 138 13 4,
-- `- 1
70S 234 | 41.4 47.6 SJ 24.5 I.SS0 1.730 ; 3.650 4.000
2.343 I4J
276 51.9 334 2.050 4.450
2.117 21.0
305 *3.0 17.1 USO 4.000
2.440 | M 1 *340 too MOO; 124.4
7.712 ! 3.462 ' 4.360
11.042 . 13.066 j 17.706 6.302 i 10.490 t 13.110
4.050 130.1
4304 21.042 15.733
3.113 1 23.4
-!
343 1 599 401 2.440 6J0Q
4.111 30 o! 27.01 ISO 1
043; 660 1.340 6.200 1
4312 34.0 343
442 100.2 60.4 4.240 6J0Q
4312 4S.0 41.7
675 1129 943 5.050 10.600
fuel control--Gas . -0l
. j-- j-
On-OH
On-Off
-i-
Air rettiol
i--
Proframminf and flame sefefuatd control \--
Gas controls--Min. inlet pressure
1 6*
--Size 1 1"
Melon--Fen--HP .. --Voltafe --Oil pump--HP. --Voltafe -Air Unit -HP --Voltafe
!W i--
-- '--
--
Electric preheater*--Watts --Voltafe
---- --
Fned 7-4 Pre Purfe and Post-Puffe Timer With BA-890C
6- 1 6* 6* 6* > 6' 1- 1 1*4" 1*4- IK* i IK*
6* r:
H 1 tt
tt K i tt
115-60-1
K
- -|
- i-
______L -|
No. 4 and Mo 5 Oil Only-Requires Separate Fused Disconnect Switch By Others
Low Fir*.
Twk
6-415^
6* 6K* 6K* *K*
rr
rr
tt K IK IK
--230-60 l --
230-60-3
~
--Modulatmf Modulatinf
-4-- --
Modulatmf FireyeFP-7
_
_
*K* 2tt"
.
*' 2K'
7K* ; 7tt" 2K* : 3*
IK 2 iL *
3 230 60 3
tt
230-60 1
5 tt ,
i > IK ik ;
" t-
230-60-3
-
1 5.000 s.ooo 5000
230-60 1
--
f , * KBIT HUMBER . - . ~ | -45
EP.-g-E** i*-*
A -- Ooiler lenfth Ai--Overall lenfth* At--Overall lenfth tncludmf tube removal* tB --Overall width C --Overall heifht C.-Shell hwfht
30H
6SK 70 37K 62 tt 55
36K 71K
37K 42K 55
42K : 44K
77K I3K 94 , 106
37K ' 37K
6?tt 55
44K 55
42tt 77K 94 42
71K 62
30K 45K 110 42 74 62
68 93 125 42 74
6?
67
56K
64K 72
79K
102 36K 104K II?
1I9K
143 123
139 154
169
42 49
49 49
49
74 83
33 83 83
62 71
71 71
71
0 --Boiler centerline to ftealcst width E --6rai smofcebox depth
-- Bear outlet -- Top outlet
21K
s *K
f --Burner to Iron! ot boiler
i -- Boiler inside width
Ki -- Firebox lenfth
Kj--Firebox width Aj--firebox heifht
27 28 tt 25tt 24 18tt
L --Smoke oullet diameter N --Smoke oullet herfht
--Beat outlet -- Top outlet
6
36 43
P --Supply we Q --Supply location R --Supply heifht
4 10 56
S --Return location -- Return we
? 3
V -- Solely valve Ixation W --Normal waterline 7 --Coil connection heifht
18 45 47
AA -- Base lenfth BB --Base width
33 tt 3?tt
FF --Burner front to base CC --Standard fas tram to base HH -- Tube removal space
25tt 5 31tt
Add for increased lenfth for lop outlet see 0-m [
Zltt
IK
27 28tt 3Itt 24 18tt
6
21tt i 1
K
21tt
8 BK
27 ?8tt
37tt 24
18tt
27
28K 43K 24
IStt
6
23K
8 10tt
27 3?tt 37K 28 23
8
23K
1 10tt
27 32tt 45 28 23
I
* * 36 4! 43 43 1 3 49
41 49
* 4i` 4
14 1 16
14
4 17
56 1 56
63
63
7; 7
7tt 7K
3 3i 1 4
`
20 22 1 2i 2?
*5 45 i 45 5? 47 47 47 54
77 52
39tt 32K
;45K
sik
37K ! 32K
45tt 37
S3K 37
25K 75K 1 75K 25tt 5 51 5 37tt 43tt ; 49tt 43tt
25K 7 5IK
**150 lb American Std Fla|e
23K 23K 27
27 27
27
8 )0tt
27 32K S3 28 23
8
1 lOtt
27 32K (2 28 23
8
9 12K
31 39K 51 35 28
10
3 12tt
31 39K 59 35 28
10
9 12K
31
3SK 66tt 35 28
to
9 12K
31 39tt 74 35 28
10
41
41
<7K
*7K 87K ' <7K
49 49 58
58 58
58
4
4
6** 6** 6**
6**
19 2? 16
ii 20
24
63 63 7Stt 75K 75tt : 75tt
7tt 7tt 7K 4 44
7K 7K 44
7K 4
29 52 54
61tt 37
32 28 52 (0 54 62
70 59tt
37 ! 44
30 32
36
60 60
60
62 62 !
67K
75 44
1 8?tt
1
25tt 25tt . 29K
IK IK , **
59 68 1 S7K
29K 29K j 29tt IK IK 1 K 65tt 73 ! I0K
tAdd CG for increased width on fas and fas oil units
91 136 195 44K 43K
71
J7K
1? 17K
33 * 84 tt 42 36
16
52 62
I** 27 83
7K 4
64 67
125 54
IK 17 92
u? 137 237 66K 93tt 78
37tt
132 17? 277 66V5 93K
78
37K
1? 17K
33 48 105tt 42 36
16
12 17K
33 48 125tt 42 36
18
52 5? 6? 6?
I** 38 83
8** 48 83
7tt 7K 44
56 64 67
146
* Itt 1
12 1
113 |
66 64 67
166
54
IK 12 .33
24354
7
STANDARD AND OPTIONAL EQUIPMENT
KEWANEEf
STANDARD EQUIPMENT
OPTIONAL EQUIPMENT
ALL UNITS
1. Three-Pass ASME Code Boiler 2. Refractory Filled Skid Type Base 1 Gas-Tight Insulated Front Smokebox 4. Pyrex Observation Ports (Front and Rear) 5. 27 Firetubes--Roller expanded 6. Gas-Tight Rear Smokebox with Horizontal Discharge (Rear) Vent 7. Wrap-around Insulated Steel Jacket 8. Lifting Loops (Units M-335 thru M-505) 9. Washout Plug Socket Wrench and Flue Cleaner with Handle 10. Forced Draft Operation 11. Operating Limit Control 12. Safety High Limit Control 13. Control Voltage--115 V. 60 cy. 1 ph. Includes Reduced Voltage Trans
former where required 14. Control Cabinet Including: Electronic Flame Safeguard, Programming
Control. Control Circuit Fuse. Burner Switches. Indicating Lights (2). Numbered Terminal Strip. Color Coded Wiring. Engraved Name plates. and Necessary Relays. Magnetic Starters, and Transformers 15. Listed Standard and Selected Optional Equipment Mounted. Piped. Wired, Ready tor Field Connection to Fuel. Water. Steam, and Elec tricity (Exceptions: Items shipped separately to prevent shipping damage) 16. Starting Service
1. Explosion Relief Door 2. Vertical Discharge (Top) Vent 3. Instantaneous or Tank Type Hot Water Coils 4. Flue Gas Temperature Gauge 5. Alarm Bell or Alarm Horn 6. Circuit Breaker 7. Other Than Standard Voltages 8. Controls for FM 9. Controls for FIA 10. One Year Service Period
STEAM UNITS
1. No. 767 Low Water Cut-Off (Units M-45 thru M-265) 2. No. 157 Combination Water Column. Low Water Cut-Off. and Pump
Control (Units M-335thru M-505) 3. Safety VaIve(s) 4. Compound Steam and Vacuum Gauge 5. Water Gauge and Glass
1. Combination Low Water Cut-Off and Pump Control 2. Combination Water Feeder. Low Water Cut-Off. and
Alarm Switch 3. Second Low Water Cut-Off
1. No. 764 Low Water Cut-Off 2. Relief Valve(s) 3. Combination Altitude Gauge and Thermometer
HOT WATER UNITS
1. Combination Water Feeder. Low Water Cut-Off, and Alarm Switch
2. Second Low Water Cut-Off
PRESSURE ATOMIZING OIL UNITS M-45 thru M-265
1. High Pressure Mechanical Atomizing Oil Burner for No. 2 Oil 2. Two-Stage Oil Pump direct connected to Burner Motor 3. Motor Horsepower and Voltage--
Vi HP. 115 V. 60 cy. 1 ph. (Units M-45thru M-75) Vi HP. 115 V. 60 cy. 1 ph. (Units M-95 thru M-155) Vi HP. 230 V. 60 cy. 1 ph. (Unit M-175) 1V6 HP. 230 V. 60 cy. 3 ph. (Units M-205 thru M-265) 4. On-Off Firing Sequence (Units M-45 thru M-115) On-Off Firing Sequence with Low Fire Start (Units M-135 thru M-265) 5. Fixed Position Air Supply (Units M-45 thru M-175) Two-Position Air Supply Controlled by Modutrol Motor (Units M-205 thru M-265) 6. PA-890 Flame Safeguard with Photocell Flame Detector and T-4Timer for Pre-Purge and Post-Purge Timing (Units M-45 thru M-175) 7. R-4150 Flame Safeguard with Photocell Flame Detector (Units M-205 thru M-265) 8. Oil Atomizing Nozzle (Dual Nozzles on Units M-205 thru M-265) 9. Oil Solenoid Valve (Dual Valves on Units M-135 thru M-265) 10. Direct Spark Electric Ignition 11. Oil Filter (Not Mounted) 12. Factory Component and Control Check
1. Fireye Flame Safeguard System 2. DC Voltmeter for Fireye System 3. High-Low-Off Firing Sequence (Units M-95 thru M-265) 4. Modulating Firing Sequence (Units M-135 thru M-265) 5. Manual Potentiometer for Modulating Fire Control 6.. Factory Firetest
PRESSURE ATOMIZING OIL UNITS M-335 thru M-505
1. High Pressure Mechanical Atomizing Oil Burner for No. 2 Oil 2. Two Stage Oil Pump Assembly with Gauge. Relief Valve. V3 HP,
230 V. 60 cy. 1 ph. motor 3. Motor Horsepower and Voltage--
2 HP. 230 V. 60 cy. 3 ph. (Unit M-335) 3 HP. 230 V. 60 cy. 3 ph. (Unit M-425) 5 HP. 230 V. 60 cy. 3 ph. (Unit M-505) 4 Modulating Firing Sequence with Low Fire Start 5 Modutrol Motor with Low Fire Interlock to Control Air and Fuel Supply 6. Operating Control for Modutrol Motor (Boiler Mounted) 7. DC Voltmeter for Fireye System 8 Manual Potentiometer 9. Fireye FP-2 Flame Safeguard System with Lead Sulphide Flame Detector 10. Air Flow Safety Switch 11 Variable Capacity Oil Nozzle 12. Oil Solenoid Valve 13. Oil Metering Valve 14. Gas Electnc Ignition Assembly 15 Oil Filter (Not Mounted) 16 Factory Firetest
24355
I-
STANDARD EQUIPMENT
OPTIONAL EQUIPMENT
AIR ATOM
Low Pressure Air Atomizing Oil Burner for No. Air-Oil Unit Consisting of: Air Compressor, Motor
Pressure Regulating Valve. Air Proving Safetyl and Oil Pump Assembly with Gauge and Interr 3. Air Unit Motor Horsepower and Voltage-- 1V4HP, 230 V. 60 cy. 3 ph. Blower Motor Horsepower and Voltage-- 2 HP. 230 V. 60 cy, 3 ph. (Unit M-335) 3 HP. 230 V. 60 cy. 3 ph. (Unit M-425) 5 HP. 230 V. 60 cy. 3 ph. (Unit M-505) Modulating Firing Sequence with Low Fire Start Modutrol Motor with Low Fire Interlock For Fuel-Air Control Operating Control for Modutrol Motor (Boiler Mounted) DC Voltmeter lor Fireye System Manual Potentiometer for Modulating Fire Control Fireye FP-2 Flame Safeguard System with Lead Sulphide Flame Detector 11. Air Flow Safety Switch 12. Air-Oil Nozzle 13. Oil Metering Valve 14. Thermostatically Controlled Electric Oil Heater-- 5.000 Watts (On No. 4 & 5 Oil Only) 15. Gas-Electric Ignition Assembly 16. Oil Strainer (Not Mounted) 17. Factory Firetest
GAS UNITS M-45 thru M-265
1. Multiple-Jet Flame Retention Type Gas Burner 2. Motor Horsepower and Voltage--
V4 HP, 115 V. 60 cy, 1 ph. (Units M-45 thru M-75) V5 HP. 115 V. 60 cy. 1 ph. (Units M-95 thru M-155)
HP. 230 V. 60 cy. 1 ph. (Unit M-175) Wt HP. 230 V. 60 cy. 3 ph. (Units M-205 thru M-265) 3. On-Off Firing Sequence (Units M-45 thru M-175) On-Off Firing Sequence with tow Fire Start (Units M-205 thru M-265) 4. Fixed Position Air and Fuel Supply (Units M-45 thru M-175) Two position Air and Fuel Supply Controlled by Modutrol Motor
(Units M-205 thru M-265) 5. RA-890 Flame Safeguard with Flame Rod Flame Detector and T-4
Timer for Pre-Purge and Post-Purge Timing (Units M-45 thru M-175) 6. R-4150 Flame Safeguard with Flame Rod Flame Detector
(Units M-205 thru M-265) 7. Air Flow Safety Switch 8. UL Gas Control Group Including: Automatic Operating Gas Valve;
Automatic Safety Gas Valve (Units M-95 thru M-265 only); Gas Volume Control Valve (Units M-205 thru M-265 only); Gas Pressure Regulator; and Manual Gas Cock 9. Gas tlectric Ignition Assembly 10. Factory Component and Control Check
1. Fireye Flame Safeguard System 2. DC Voltmeter tor Fireye System 3. High-Low-Off Firing Sequence (Units M-95 thru M-265) 4. Modulating Firing Sequence (Units M-95 thru M-265) 5. Manual Potentiometer (or Modulating Fire Control 6. Automatic Safety Gas Valve (Units M-45 thru M-75) 7. Gas Controls for Other Than Standard Pressures 8. Factory Firetest
GAS UNITS M-335 thru M-505
1. Flame Retention Type Gas Burner 2. Motor Horsepower and Voltage--
2 HP. 230 V. 60 cy. 3 ph. (Unit M-335) 3 HP. 230 V. 60 cy, 3 ph. (Unit M-425) 5 HP. 230 V. 60 cy. 3 ph. (Unit M-505) 3. Modulating Firing Sequence with Low Fire Start 4. Modutrol Motor with Low Fire interlock to Control Air and Fuel Supply 5. Operating Control for Modutrol Motor (Boiler Mounted) 6. DC Voltmeter for Fireye System 7. Manual Potentiometer
8. Fireye FP-2 Flame Safeguard System with Lead Sulphide Flame Detector
9. Air Flow Safety Switch
10. UL Gas Control Group Including: Automatic Operating Gas Valve Automatic Safety Gas Valve; Gas Volume Control Valve; Gas Pressure Regulator; Gas Pressure Gauge; and Manual Gas Cock
11. Gas tlectric Ignition Assembly
12. Factory Firetest
1. Gas Controls for Other Than Standard Pressures
1. Manual Fuel Changeover Switch
COMBINATION GAS-OIL UNITS
24356
FOR ALL UNITS M-45 THRU M-505
The contractor shall furnish and install
Model No.
. Square-Heat Generators) for (No. (2) (4) (5) oil),
(gas), (combination gas-No. (2) (4) (5) oil) firing. The unit(s)
shall be three-pass compact firebox design with arched up
right crown sheet and two passes of firetubes, and constructed
in accordance with the ASME Code for (15 lbs. steam) (30 lbs.
water).
Unit(s) shall have not less than
total square feet of
waterside heating surface including a minimum of
square feet of primary or direct heating surface.
Unit(s) shall contain not less than..................... cubic feet ot
furnace volume and shall have a gross output rating of not less
than.................. MBh. Heat release shall not exceed 83.200 Btu per cubic foot ot furnace volume.
Normal water line of unit(s) shall not exceed.
inches.
A pyrex observation port shall be provided at the rear of the
firebox. Front flue access cover, with refractory securely keyed
in place and of a size permitting easy access to all fire tubes,
shall be mounted on a gas-tight, insulated front smokebox.
Gas-tight rear smokebox shall be provided with a (rear) (top)
outlet.
Unit(s) shall be provided with a wrap-around steel jacket with glass or mineral fiber insulation and smooth enamel finish.
All tubes shall be set with a roller expander at each end. No welding of tubes to the tube sheets nor use of refractory baf
fling to provide the second or third pass will be permitted.
Unit(s) shall be assembled and wired, with burner, controls, trim, insulated steel jacket, and refractory filled skid type base
installed at the factory
Fuel burning equipment shall be forced draft type: Factory
assembled, wired, mounted, and tested. The entire unit shall bear the Underwriters' Laboratories label and shall be ready
for field connection to power and fuel supply. Equipment shall include forced draff fan with air damper; dual high limit con
trols; flame sensing device, and control cabinet containing electronic flame safeguard and programming timer, burner switch, control circuit fuse, two indicating lights for major operations, numbered terminal strips, color-coded wiring, en graved nameplates, and necessary relays, starters and switches
for automatic operation.
All motors shall be for
volts.
cycle.
phase operation. Controls sha'I be 115 volt. 60
cycle, single phase. Magnetic motor starters with thermal over
load protection and a step-down control circuit transformer
shall be provided in the control cabinet when other than 116
volt motors are specified.
Fuel burning equipment shall be set and adiusted by a factory
authorized representative to burn
G.P.H. of No. (2)
(4) (5) oil (and) (or)
C.F.H. of
Btu/cu.
ft. (natural) (manufactured) (L.P.) gas having a
sp gr. with
inches w.c. pressure at inlet of burner
manual gas cock. Unit efficiency, based on flue gas analysis,
shall be not less than 80% NOTE: Specify job altitude if over
2,500 ft. above sea level Owner's representative shall be pres
ent to receive instructions in care and maintenance of the unit at
the time it is started up by the service representative. Contrac
tor shall provide a free service period ot 90 days after start-up.
NOTE: Select applicable paragraphs below according to fuel and
unit size. The following equipment conforms to UL requirements. Specify additional controls if EM or FIA insured, or subject to
special utility requirements
FOR PRESSURE ATOMIZING OIL UNITS M-45 THRU M-175
Oil burner shall be of the high pressure mechanical atomizirg type for No. 2 oil, with a two-stage oil pump direct connected to the blower motor. Burner shall include oil atomizing nozzles oil solenoid valves; 12,000 volt ignition transformer; T-4 Timer for pre-purge and post-purge; RA-890E flame safeguard wir photocell flame detector: and all necessary controls for "cr oft" type of operation. Air control shall be by fixed position ar inlet damper and adjustable primary-secondary air shutter.
FOR PRESSURE ATOMIZING OIL UNITS M-205 THRU M-265
Oil burner shall be of the high pressure mechanical atomizing type for No. 2 oil. with a two-stage oil pump direct connecter to the blower motor. Burner shall include dual oil atomizing nozzles; dual oil solenoid valves; 12.000 volt ignition trans former; R-4150 flame safeguard with photocell flame detector and all necessary controls and linkage for "on-off" type & operation with controlled low fire start. Fuel-air control sha' provide two-position regulation of the air inlet damper and the high fire oil solenoid valve by means of a modutrol motor.
FOR PRESSURE ATOMIZING OIL UNITS M-335 THRU M-505
Oil burner shall be of the high pressure mechanical atomizing type for No. 2 oil. with a two-stage oil pump assembly with in ternal relief valve mounted on the boiler base. Burner shall in elude variable-flow oil atomizing nozzle; oil solenoid valve oil metering valve; gas-electric ignition assembly. 6,000 vol: ignition transformer, automatic gas valve, gas pressure regu lator, and manual gas cock; air flow safety switch: Fireye FP-.flame safeguard system with lead sulphide flame detector; lo fire interlock; and all necessary controls and linkage for modu lated firing with proved low fire start. Fuel-air control shal provide modulated regulation of the air damper and the oi metering valve by means of a modutrol motor.
FOR AIR ATOMIZING OIL UNITS M-335 THRU M-505
Oil burner shall be of the low pressure air atomizing type foNo. 5 or lighter oil with an air-oil unit consisting of air compres sor, motor, inlet air filter, air proving safety switch, air gauge oil pump assembly, and relief valve mounted on the boilebase. Burner shall include air-oil atomizing nozzle, oil solenotc valve; oil metering valve, thermostatically controlled electric heater (omit for No. 2 oil), gas-electric ignition assembly; 6,00'. volt ignition transformer, automatic gas valve, gas pressure regulator, and manual gas cock; air flow safety switch. Fireye FP-2 flame safeguard with lead sulphide flame detector, lo fire interlock; and all necessary controls and linkages for mod ulated firing with proved low fire start. Fuel-air control shah provide modulated regulation of the air damper and the oil metering valve by means of a modutrol motor.
FOR GAS UNITS M-45 THROUGH M-175
Gas burner shall be of the multiple-jet flame retention type in eluding a main gas control group consisting of an automatic diaphragm gas valve, automatic safety gas valve on inputs over 1,000 MBh, gas pressure regulator, and manual gas cock; gas electric ignition assembly consisting of a 6,000 volt ignition transformer, automatic gas valve, gas pressure regulator and manual gas cock; air-flow safety switch; T-4 Timet for pre purge and post-purge; RA-890E flame safeguard with flame rod flame detector; and all necessary controls for "on-off" type of operation. Air control shall be by fixed position air inlet damper and adjustable primary secondary air shutter
io 24357
TYPICAL SQUARE-HEAT GENERATOR SPECIFICATIONS
FOR GAS UNITS M-20S THRU M-265
Gas burner shall be of the multiple-jet flame retention type, in cluding a main gas control group consisting of an automatic diaphragm gas valve, automatic safety gas valve, gas volume control valve, gas pressure regulator, and manual gas cock; gas-electric ignition assembly consisting of a 6.000 volt ignition transformer, automatic gas valve, gas pressure regulator, and manual gas cock; air-flow safety switch; R-4150 flame safeguard with flame rod flame detector; and all necessary controls and linkage for "on-off" type of operation with controlled low fire start. Fuel-air control shall provide two-position regulation of the air inlet damper and the gas volume control valve by means of a modutrol motor.
FOR GAS UNITS M-335 THRU M-505
Gas burner shall be of the flame retention type including a main gas control group consisting of an automatic motorized gas valve, automatic safety gas valve, gas volume control valve, gas pressure regulator, gas gauge, and manual gas cock: gaselectric ignition assembly, 6,000 volt ignition transformer, auto matic gas valve, gas pressure regulator, and manual gas cock; air flow safety switch; Fireye FP-2 flame safeguard with lead sulphide flame detector;~fow fire interlock; and all necessary controls and linkage for full modulated firing with proved low fire start. Fuel-air control shall provide modulated regulation of the air damper and the gas volume control valve by means of a modutrol motor.
FOR COMBINATION GAS-PRESSURE ATOMIZING OIL UNITS Nl-45 THRU M-175
Gas-oil burner shall consist of a combination multiple-jet flame retention type gas burner and a high pressure mechanical atom izing oil burner for No. 2 oil. including all necessary controls for "on-off" type of operation. Gas controls shall include a main gas control group consisting of an automatic diaphragm gas valve, automatic safety gas valve on inputs over 1,000 MBh, gas pressure regulator, and manual gas cock; gas-electric ignition assembly consisting of a 6,000 volt ignition transformer, auto matic gas valve, gas pressure regulator, and manual gas cock; and flame rod flame detector. Oil controls shall include a twostage oil pump direct connected to the blower motor: oil atom izing nozzles, oil solenoid valves; 12,000 volt ignition trans former. and photocell flame detector. Controls for both fuels shall include T-4 Timer for pre-purge and post-purge; RA-890E flame safeguard; and air flow safety switch. Air control shall be by fined position air inlet damper and adjustable primary secondary air shutter. Changeover from one fuel to the other shall be accomplished by means of a manual fuel selector switch in the control cabinet. No changes in linkage, burner position, or mechanical adjustment shall be necessary when changing fuels. The fuel selector switch shall provide, through the combustion control relay, proper ignition timing for the fuel being burned.
FOR COMBINATION GAS-PRESSURE ATOMIZING OIL UNITS N.-2E: THRU M-2E-
Gas-oil burner shall consist of a combination multiple-jet flame retention type gas burner and high pressure mechanical atom izing oil burner for No. 2 oil, including all necessary controls for "on-off" type of operation with controlled low fire start. Gas controls shall include a main gas control group consisting of an automatic diaphragm gas valve, an automatic safety gas valve, gas volume control valve, gas pressure regulator, and manual gas cock, gas-electric ignition assembly consisting of a 6,000 volt ignition transformer, automatic gas valve, gas pressure regulator, and manual gas cock, and flame rod flame detector. Oil controls shall include a two stage oil pump direct connected
to the blower motor; dual oil atomizing nozzles; dual oil sole noid valves; 12,000 volt ignition transformer; and photocell flame detector. Controls for both fuels shall include R-4150 flame safeguard and air-flow safety switch. Fuel-air control shall provide two-position regulation of the air inlet damper, the gas volume control valve, the high fire oil solenoid valve by means of a modutrol motor. Changeover from one fuel to the other shall be accomplished by means of a manual fuel selector switch in the control cabinet. No changes in linkage, burner position, or mechanical adjustment shall be necessary when changing fuels. The fuel selector switch shall provide, through the combustion control relay, proper ignition timing for the fuel being burned.
FOR COMBINATION GAS-PRESSURE ATOMIZING OIL UNITS M-335 THRU M-505
Gas-oil burner shall consist of a combination flame retention type gas burner and high pressure mechanical atomizing oil burner, for No. 2 oil. including all necessary controls for modu lated type of operation with proved low fire start. Gas controls shall include a main gas control group consisting of an auto matic motorized gas valve, an automatic safety gas valve, gas volume control valve, gas pressure regulator, gas gauge, and manual gas cock. Oil controls shall include a two-stage oil pump assembly with internal relief valve; variable-flow oil atomizing nozzle; oil solenoid valve; oil metering valve. Con trols for both fuels shall include Fireye FP-2 flame safeguard with lead sulphide flame detector: air flow safety switch: low fire interlock; and gas-electric ignition assembly, 6,000 volt igni tion transformer, automatic gas valve, gas pressure regulator, and manual gas cock. Fuel-air control shall provide modulated regulation of the air damper, the gas volume control valve, and the oil metering valve by means of a modutrol motor. Change over from one fuel to the other shall be accomplished by means of a manual fuel selector switch in the control cabinet. No changes in linkage, burner position, or mechanical adjustment shall be necessary when changing fuels. The fuel selector switch shall provide, through the combustion control relay, the proper ignition timing for the fuel being burned.
FOR COMBINATION GAS-AIR ATOMIZING OIL UNITS M-335 THRU M-505
Gas-oil burner shall consist of a combination flame retention type gas burner and low pressure air atomizing oil burner for No. 5 or lighter oil with all necessary controls for modulating type of operation with proved low fire start. Gas controls shall include a main gas control group consisting of an automatic motorized gas valve, automatic safety gas valve, gas volume control valve, gas pressure regulator, gas gauge, and manual gas cock. Oil controls shall include an air-oil unit consisting of an air compressor, motor, inlet air filter, air proving safety switch, air gauge, oil pump assembly and relief valve; air-oil atomizing nozzle; oil solenoid valve; oil metering valve; thermo statically controlled electric oil heater (omit for No. 2 oil). Con trols for both fuels shall include Fireye FP-2 flame safeguard with lead sulphide flame detector; air flow safety switch; low fire interlock; and gas-electric ignition assembly, 6,000 volt igni tion transformer, automatic gas valve, gas pressure regulator, and manual gas cock. Fuel-air control shall provide modulated regulalion of the air damper, the gas volume control valve, and the oil metering valve by means of a modutrol motor. Change over from one fuel to the other shall be accomplished by means of a manual fuel selector switch in the control cabinet. No changes in linkage, burner position, or mechanical adjustment shall be necessary when changing fuels. The fuel selector switch shall provide, through the combustion.control relay, proper ignition timing tor the fuel being burned.
24358
1
r dUALrrr
r
*
13 32 1NG-IN I RSD.
e CO govO tVOU LkMXxHF gGCvtOS- iGSXffiSCU c c
\
KEWANEE
bulletin 149D
V - 'W:: -
_hSPr:'
;ir; V
24360
. OIL OR GAS combination gas-oil
HIGH AND LOW PRESSURE
./American-Standard ES-Ti'ii f/1- jgass--
responsibility
HIGH PRESSURE 82 to 672 hp.
125-150 lb. steam wp std. Higher pressures on application
experienced engineering assures peak performance
Certified ratings are conservative--five square feet of A.S.M.E. (fireside) heating surface per horse power-providing adequate reserve capacity. Firing rates are carefully matched to heating surface. Flame size and shape are matched to furnace dimensions. Furnace volume is designed for efficient combustion, and direct heat absorbing surfaces are ample. Construction meets or exceeds A.S.M.E. Code requirements. Entire unit is listed by Underwriters Laboratories, Inc.
Kewanee Forced Draft Scotch Package Units present a combination of high quality, experienced engineering, modern concept and conservative design which assure you highest efficiency, faithful performance and long time dependability. These qualities have been proved in many thousands of installations... Kewanee has been the leader in the steel boiler industry for nearly a century.
24361
IS lb. steam or 30 lb. water std. Higher water wp '250` man. on application.
FACTORY ASSEMBLED FIRE TESTED BEFORE SHIPMENT
FORCED DRAFT OPERATION
Assures an ample supply of combustion air for stub stack appli cations. Special blower assemblies are available for high alti tude installations.
OVERSIZE FURNACE TUBE
Provides abundant volume for complete combustion and greater proportion of primary heating surface. The hot flanged furnace tube openings assure maximum permanent strength at junction ot furnace tube and tube sheets. The high pressure unit furnace tube is corrugated for greater strength and more primary heat ing surface. Location near bottom of boiler affords maximum protection against low water.
TUBES
All tubes in high and low pressure units are 3' 0D, set into trepanned holes by roller expander and beaded at each end. No tubes welded to tube sheets. Spinner blades in all tubes swirl hot gases against tube surfaces for longer gas travel and maximum heat transfer.
TWO PASS DESIGN
Eliminates refractory baffles that can burn out and short circuit hot gases to stack. Kewanee design avoids wasted fuel, costly shutdown and expensive repairs.
LARGE STEAM SPACE
Combined with abundant unbroken disengaging area and un usually large water content assures steady water line, dry steam and plentiful reserves.
WELDED SHELL
Flange quality plate. Heads and furnace tube are firebox steel. Exclusive head braces are one-piece forgings with ends ex tending through boiler shell and heads. High pressure shells are X-rayed and stress relieved.
CAST IRON FLUE DOORS
An exclusive Kewanee feature--heavily insulated--precision ground and gasketed for gas tight fit. Hinged to provide quick access to tubes without interference with firing equipment.
I-BEAM SKIDS
Rugged with extra heavy reinforced saddles. They support the unit, distribute the weight evenly and facilitate handling.
INSULATED STEEL JACKET
Factory installed heavy gauge steel jacket of drawband con struction with T of glass fiber insulation and a 12' catwalk.
water heating coils
Standard Kewanee "Kl" (instantaneous< and "KT" itank) coils can be provided for all low pressure units.
24362
3
Kewanee horizontal rotary gas-oil combination burner
A very adaptable burner which handles efficiently all types of gas and the complete range of fuel oils. Oesigned especially for forced draft firing. Versatility greatly simplifies fuel supply problems. Completely automatic controls assure smooth functioning. Oil pre heating equipment, complete with automatic thermostatic control is available for firing No. 6 and heavy No. 5 oils.
The oil burner combines the time-tested rotary cup principle of oil atomization with a unique method of air control for most efficient air-fuel mixtures.
I
a ,t \ \ v-rj 4 rr, ~
Horizontal rotary oil burner
Same as combination, but without gas burner.
Kewanee ring type gas burner
Multi-jet construction with specially designed gas manifold ring. Angle-drilled orifices mix gas with secondary air in burner throat ahead of combustion zone. Provides quiet, efficient gas firing with good flame retention.
Gas burners are available for all types of gas . . . to meet any gas pressure supply ... or to meet any special utility or insurance re quirements.
Cast aluminum multi-pass reservoir, with immersed thermostat control. Low watt density elements and long oil travel through several passes combine for accurate temper ature control at all firing rates.
Air-fuel ratio adjustment
Exclusive Kewanee curved slot linkage is the simplest and most permanent method of ad justing fuel-air ratio. Regulates air-fuel ratio throughout load range with no slippage or "drifting." Result is higher efficiency, fuel savings. This design permits swinging the burner out full 90 without disconnecting linkage.
Separate oil pump sets
Available for use on multiple installations or for separate mounting.
/
4
24363
;
)ti
a;] 9aas^ajm-. ;
"
' VKeuwinannseae FFonrrcrperdf DDrraafftt SScrnottcrhh ParUaop Unit? arpavailahle with.'-** kewanee :Horlzontat n*rv.;; *
'S>t&&TtsyJlpJb/e6aGaMatr#sM*~BWauHerUn^Ie*--ir^I,|A*Wo-an*l Kae*iBw KanSe.eV4G.' as-OibCombination Burner.;
;-* Each' burner ^'especially designefifttLtheiKewaneesBoiieKiti;%tfiresx;Capadty'ana,ctiaracteris6Ka5arefuH3f';matdied5sY ;i "vthatboilecandbumerworkasan efiectiyeteam? bghtorne
k. ''.'W*;-,- -yC.V- *'". .'',~.'A v nils hfPh Of low Oresstire MS mavhefired efficiently All fhrpp
^ Some features of the dependable ^ Kewanee Burner are shown below:
Control cabinet
Heavy gauge steel, dustproof--contains individual fuses for each circuit. Enclosed controls include magnetic motor starters with thermal overload protection .. rmaster programming relay, etched nameplates, indicating lights for major operations, numbered terminal strips, wiring troughs, fuel selector switch. Wiring diagram and holder for instruction manual mounted inside door.
SIjOc*TnICc
i -- COWTICTM
Exclusive--adjustable variable vaned air nozzle
Readily permits shaping the oil flame for different grades of fueL
I
I
Burner latch switch
Exclusive design includes
> safety interlock to prevent burner operation when burner is not locked in firing position. Releases easily for mainte
D nance service. Eliminates
troublesome twist lock plugs.
>
>
I
Viscosity compensating valve
The ultimate in simplicity . . . no complex mechanisms . . . no moving parts to wear. A simple adjustment sets the high fire and assures an accu rately proportioned supply of oil to atomizing cop.
Change fuels with flip of a switch
That's all that's needed. No readjustment of linkage--no burner change.
24364
KEWANE forced draft package units
(high pressure)
ratings
Unit number * --
Rating--horsepower --M8tuh -- steam per hour 212rF --steam radiation
Firing rate--oil 140000 Btu -oil 150000 Btu -gas
Heating surface ASME Net turnace volume
Safety valve capacity lb steam per hr
lb sq ft
gpn gph MBtuh
sq It. cu ft
80
82 2769 2840 It MO
24 7 23 l 3461
412 62 5
3296
81
95 3179 3260 13240
28.4 26 5 3973
473 67.7
3784
82
116 3911 4020 16300
34 9 32 6 4889
582 85 4
4656
83
137 4610 4730 19210
41.2 38 4 5762
686 94.2
5468
84
169 5665 5820 23600
50.6 47 2 7081
643 1185 6744
65
202 6787 6970 28280
60.6 56 6 8484
1010 149 9
8080
86
236 7916 8130 32980
70 7 66 0 9895
1173 164 t
9424
87
270 9072 9310 37800
81 0 75.6 11340
1350 1851
10800
88
338 11357 11660 47320
1014 94.6 14196
1690 228 2
13520
89
405 13595 13960 56640
121 4 113 3 16993
2023 271 3
16184
90
469 15758 16180 65660
140 7 131.3 19698
2345 333.5
18760
9i
538 18070 18550 75290
161 3 150 6 22588
2689 348 7
21512
92
605 20321 20870 84670
181 4 169 3 25402
3024 39J 1
24192
93
672 22572 23180 94050
201 5 188 1 28216
3359 437 6
26872
data
Outside surface to cover (unjacketed) Appronmate dry weight--125 lb W P
-1501b WP Vent diameter
sq. ft in
178
13700 14600
15
197
14450 15050
16
i22
16550 17450
17
252
19100 20100
19
297
22150 23350
20
352
26550 27850
22
3731 383
29950 33600 31450 35400
23 24
438
38450 40550
26
493
45100 47300
28
ii5
50300 52900
30
558
54650 58350
32
601
59950 64050
34
644
65100 69700
36
dimensions, inches
Unit number* A "length overall 8 "Width overall C --boiler--width D --length E -- inside diameter
F --steam supply height G --smoke outlet height H --water line height
J --safety valve height
K --steam supply L --safety valve . M --feed water N --biowoff
0 --smoke outlet--inside width R -- inside length
S --steam supply site T -lets sue U -blow-off site
W --furnace--height X -- inside diameter Y -- rear chamber
AA -- base--width BB -- floor to boiler CC --length DO EE --location rf -- tube replacement space
GG -- ccntroi panel HH --control panel JJ -- fan to CL o< unit
80
176 84 V, 65 139 60
84
854 674
89
37 51 30 48
12 17
4
i'/. 2
3714 26V. 24
60 18 137Vj 6 174
83
33 17 m
81
1904 84 V, 65 1534 60
84 854 674
90
43 52 37 48
12 17
4 IV. 2
374 26V. 24
60 18 1514 6 18
97"
33 17 43*
82
194 88 71 158 66
904 91 71
94
44 53 37 51
13 22
6 14 2
39 29 Vi 26
66 18 153!* 8 19!*
9B
32 17 434
63
216 91 71 178 66
904 91 71
108
50 60 47 51
13 22
6 14 2
39 29 M 26
66 18 1734 8 I9l/r
118
34 19 46'*
84
230 94 774 193 72
97 974 75
1174
57 60 53 53
14 23
6 14 2
41 31V, 28
72 184 189 8 214
129
33 15!/? 46'/J
85
2354 98 84 199 78
1024 102
784
1224
58 60 47 64
15 28
6 14 2
42 34 Vi 33
78 174] 1891* 8 264
128
32 Vt 15V? 46 Vj
86
262 V? 1094 84 223 78
1024 102 784
1264
64 78 59 64
15 28
6 14 24
42 34'/. 33
78 17V213!* 6 261*
152
35-4 18-/! 58 1
87
2514 \nv. 90 213 84
108 108 82
132
65 66 52 66
16 29
6 14 24
43 38 33
84 17 2014 10 274
139
344 18!* 58 1
68
266 1154 96 227 90
1144 113 89
144
65 78 60 66
16 34
8
14 24 44'/?
404 35
90 17 229!* 10 30
151
35 24 58 1
89
280 1224 102 240 96
1214 1194 94
1504
66 84 66 66 17 37
8 2 24
474 44 34
96 18 242!* 10 29
162
36
6?
90
280 1254 108 241 102
1274 1254 100
1584
67 84 66 66
18 40
6 2 24
494 50 34
96 18 2424 12 29
161
35 4:*?
91
285 1274 112 247 106
1324 1294 104!*
162
68 84 66 71
19 42
10
24 24
504 50 34
96 18 2481*
12 28
165
34 44
62
92
293 1424 116 256 110
136 133 1074
166
72 84 67 75
20 44
10
24 24
52 52 39
96 18 254 12 31
167
33 4 75
'For complete unit numoef aesignations tor various tuels reler to Kewanee Burner Data page 8
24365
93
300 U4* 120 265 114
140 1374 1104
179
72 84 71 80
21 47
10
24 24
52 52 46
102 16 252 12 40
16'
31 4 5
ratings
Unit number Rating--horsepower
--MBtuh --steam per hour 212"F --steam radiation --water
MCA net steam radiation Firing rale--oil 140000 Btu
--oil 150000 Btu -gas
Heating surface A$ME Net furnace volume Safety valve capacity tb steam per hr
data
Outside surface to cover (unjaeveted)
Approximate dry weight
Vent diameter
lb sq ft sq M
sq ft gph SPA
MBtuh
sq ft cu ft
80
83 2802 2880 11680 18680
8580 25 0 23 4 3503
417 62 5
2802
81
97 3259 3350 13580 21730
10000 29 1 27 2 4074
485 69 1
3259
82
118 3958 4060 16490 26390
12160 35 3 33 0 4948
589 83 5
3958
83
139 4657 4780 19400 31050
14300 41 6 38 8 5821
693 93 3
4657
84
173 5820 59BQ 24250 38800
1 7660 52 0 48 5 7274
866 1128
5820
85
208 6982 7170 29090 46550
21440 62.3 58 2 8728
1039 137 4
6982
86 s;
24? 277
8138 1 5300 8360 i 9550 33910 38250 54250 , 2000
>:
::3:: 4?a:: "4--:
250001 28580
72? 85 0-
67 8 77 5 1 10122 1 11626
!*.; * Hi
1211 I 1384. 152 61 182.0, 21:4
8138 | s3oo i;-:.:-
?9 4;5 ` 'n\` ::::o ::\V0 2?20 42360 2 24 4 ::s1
2074 2'? 1 .393?
90
464 16256 16690 67730 108370
50000 145 1 135 5 20320
2419 338 0
16256
9i
552 18574 19070 77290 123835
57140 165? 154 > 23 m
2764 356 2
18574
V './> /:.
.
Y. 's'. ''e> > >Y<Y.
sq It >b m
1861 208
10250 11250 151 16
233 13750
17
263 15450
19
308 17900
20
337 20300
22
37B1 4101 4-;
227501 26600. 205:C
23! 24
;;
5291
3:500 | 28 1
572 40700
30
610 4267-
Yi
^ * 'V.
'>
dimensions, inches
Unit number
A --length overall B --width overall C --boiler --width 0 --length E --inside diameter
f --steam supply height C --smoke outlet height H --water ime height
} --safety valve height
K --steam supply L --safety valve M --feed water--each side N --return--each side P -dram
Q --smoke outlet--inside width R --inside length
S --steam or watersupply size T --teturn size(two) U --dram size v --leed watersize
* -- furnace--height X --inside diameter Y --rear chamber
AA -- base--wiotn 6B --floor to boiler CC -length DD --height EE --location
?f --tube repiacemen: soace
CG --control panel Hh --control oanel J) --fan tc CL of unit
80
166 85V? 64 130 60
84 85V* 66V?
88
37 62 26 43 39
12 17
8 4 2 IVi
37V? 291* ?4
60 18 1371/? 6 S1/?
78
33 17 C3'/.
81 82 83 84
182 V* 85 V? 64 146** 60
183 91 69 148 66
205'/V 94
69 168'/?
66
21715 97 75
18115 72
84 90 90 97
8515 91 91 97V5 6615 70'/, 70V? 74(/,
88 9555 9SV9 100'/,
43 44
70 69 33V* 31 45 47 41 41
50 57 84 84 4] 43
47'/* 5115 41'/* 4115
12 13 13 14 17 22 22 23
8 88 8 4444
2222 IVi 1`/? IV? 1V5
37'/, 39 39 41 29*8 32'/? 32 V? 34 Vj 24 2i 24 24
60 16
151V? 6 11
66 18 153'/? 8 9V?
66 18 173V; 8 10
72 18 V? 189 8 10
94 i 94 i ;u i i24v,
33 32 34 j 33 17 17 19 15 V, 43' ? 4 ]'A 4c!a I 461/;
85
216V, 100 81 181'/,
78
102 102 m
105'/*
58 84 43 50'/* 46V*
15 28
8 4 2 IV*
42 3 7 Vi 28
78 17'/? 189'/? 8 8V?
119
32 14 V*
86 | 87
::
243V? 111V* 81
205'/* 78
2431,
M4i,j i;...-
87 1 93
206 I nr84 | V.
102 io7v,i v.-102 1071-11 1.. 77V* 82 1 l-~
107 113 1
64 65 96 84 49 43 56 V* 68
46V* 59
\\ 4*
15 16 | v. 28 29 1 24
8 81" 4 4 ] c2V? 21,1 : :
1`* 1-; . -
42
37i 28 33
: *
78 | 34 171,1 17
2131 -j] 231 -: 8 io 6 ;! 29
r. ;'
UI-?I 13
.
35 , 24 :: 18 ' ? ip :: 58
? I 90
;:i-,
"A :i2~,
95
274 131'/* 105 236 102
> 115:,
93
12!'/,
12515 9815
:?6 132
67 133 108 53 53
74
61
i; 16 3' 40
13 10
6* 6* 2-, 2H 22
49H 521-i ;i 34
V. 96 :? 18
24?'/?
:: 12 :. : 24
: 161
2: , 35
6?`-'
91 >>
261
I32-/J 109 244
106
'V.-
> >,
* ; '___
121 .H
125 1C2 Y.K
-
: *____
12;/>
:V -
____
68
103 Y>.
*
50 4/- -
84
e_________ \_____________
la
12 2?
:2< *
% 24366
15CI6 American Slancarc flange
"Fct compiete unit numoer Ceaijnationa lor eanoua leer. re'e''. *-Burner Data
high pressure
The contractor shall furnish and install ...................Number...................... Kewanee Forced Draft Scotch Package Unit(s) for (oil) (gas) (gas-oil combination) firing. The umt(S) shall have a certified output rating of ....................... H.P. and shall contain not less than........................sq. ft of heating surface (ASME, Fireside) and a minimum furnace volume of............. cu. ft The heat release shall not exceed 65,000 BTU per cubic foot of com bustion space when operating at certified output rating. The furnace diameter shall be no.less than............. in., the diameter of the vent..............in.
The shell shall be of the scotch type, two pass, horizontal firetube design, ASME Code construction for (125) (150) PSIG Steam. The boiler shall be mounted on steel I-beam skid base with integral forced draft burner and
burner controls.
The furnace tube openings in the front and rear tube sheets shall be hot flanged to provide maximum strength at junction of tube sheets and corru gated furnace tube. The outer edges of the tube sheets shall also be hot flanged so that the joining ol the shell and tube sheets will provide maximum efficiency. The longitudinal joints shall be double welded butt type and girth joints full fillet welds, x-rayed and stress relieved in full compliance with the latest ASME Boiler Construction Code.
The boiler tubes shall be 3" O.D. and tube holes shall be reamed not to exceed 'At' greater than outside tube diameter. All tubes shall be set with a roller expander and beaded at each end. Welded tube ends will not be permitted.
The front smokebox shall be of heavy gauge steel welded to the boiler to secure a gas tight fit. The flue doors shall be of cast iron* and gasketed to secure a gas tight fit with a minimum number of clamps. They shall be lined with refractory insulating cement securely keyed in place and capable of withstanding a temperature of 1500"F. A damper with cast iron bearings and locking quadrant shall be furnished in the flue outlet.
The rear flue gas chamber shall be of pressure tight construction, lined with insulating castable refractory and provided with an access door of at least 16' diameter.
Boiler trimmings shall consist of the following, mounted and piped:
Safety valve(s); steam gauge with siphon and cock; No. 1S7A or 157D combination water column, pump control and low water cut-off; hand operated water puge and try cocks assembly (chain operated on Unit No. 88 and larger); blow-off valves; globe and check valves for boiler feed line and injector.
Boiler shall be inspected during construction by an authorized inspector and after completion shall be subjected to a hydrostatic test one and one-half times the working pressure and stamped with all identifying markings and symbols as required by the latest edition of the ASME Boiler Construction Code.
Unitfs) shall be provided with factory installed aluminum finished jacket of 22 p. steel securely fastened with drawbands. Jacket shall have a 2* thick insulation of lightweight mineral or glass wool material of 3 lbs. density per cu. ft. attached with adhesive. A similar material of 9 lb. density, 2* thick, shall be applied at selected locations for reinforcement including the top splice where it will form a 12* catwalk along the entire length of the boiler. Cover rings shall be provided at all openinp. Lifting loops shall be provided so that unit may be handled without damage to the jacket.
'Units 80 to 90 incl.-steel doors on 91 to 93 ind.
Fuel burning equipment as follows shall be provided:
(Refer to Burner Specification)
- BURNER SPECIFICATIONS FOR
For all units
The Fuel Burning Equipment shall be an integral part of the Boiler Unit; factory mounted and factory fire-tested. The complete Boiler Unit shall bear the Underwriter s Label. Fuel Burning Equipment shall include high limit control; operating control: windbox complete with re fractory lining: linkage; gas-electric ignition assembly; forced draft fan with adjustable air inlet vanes; air-fiow safety switch; safety latch switch; modutro! motor: auxiliary end switch for low-fire start interlock; pilot manual gas cock; pilot gas solenoid valve; pilot gas pres sure regulator; ignition transformer; modulating operating control; lead sulphide scanner assembly; control cabinet containing (Fireve FP2) (M.H. R47S-B) electronic com-
Strike Out One
bustion and programming control: manual potentiometer; terminal strips and color coded internal wiring; signal lights indicating ignition, main fuel, flame failure and low water; individual fused circuits for controls, motors and heater: burner on-off switch; magnetic motor starters with thermal overload protection. All indicating lights and switches shall be identified by etched nameplates.
For gas units
Gas Burning Equipment shall be of the ring type equipped with multiple jets threaded into a manifold ring complete with gas pressure gauge; gas volume control valve; manual gas shut-off valve; gas pressure regulating valve and auto matic motorized gas control valve with safety end switch. S'OTE. Specify additional controls if FM or FIA insured.
For all types of oil units
Oil Burning Equipment shall be of the Horizontal Rotary Cup Type complete with (direct drive oil burner motor) on Units 80 thru 88 (V-belt drive oil burner motor) on Units 89 thru 93: (integral fuel pumpi for or lighter oil (separa te fuel pump^ for *6 oil: fuel oil strainer; magnetic solenoid oil valve: viscosity compensating valve; oil pressure and vacuum gauges; electric oil preheater (omit for -2or 4 oils).
(Strike out underscored items that do not apply.)
For heated nil units
Oil Burning Equipment for 6 oil shall include factory
KEWANEE BURNER DATA
No. 5 or Lighter
Oil
KPE-80 KPE-Sl KPE-82 KPE-S3 KPE-84
KPE-85 KPE-86 KPE-87 K PE-88 KVPE-89
KVPE-90 KVPE 91 KVPE-92 KVPE-93
Kewanee Model Number
No. 5 or lighter Oil & Gas
KPEC-80 KPEC-81 KPEC-82 KPEC-83 KPEC-84
KPEC-85 KPEC-86 KPEC-87 KPEC-88 KVPEC-89
KVPEC-90 KVPEC-91 KVPEC-92 KVPEC-93
No. 6
Oil
KSH-80 KSH-81 KSH-82 KSH-83 KSH-84
KSH-85 KSH-86 KSH-87 KSH-88 KVSH-89
KVSH-90 KVSH-91 KVSH-92 KVSH-93
No. 6
Oil t
Gas
KSHC-80 KSHC-81 KSHC-82 KSHC-83 KSHC-84
KSHC-85 KSHC-86 KSHC-87 KSHC-88 KVSHC-89
KVSHC-90 KVSHC-91 KVSHC-92 KVSHC-93
Gas
KG-80 KG-81 KG-82 KG-83 KG-84
KG-85 KG-86 KG-87 KG-88 KG-89
KG-90 KG-91 KG-92 KG-93
Gas Controls
Standard'--UL 1000 btu/cf--.6 s.g.
Motor Data H.P.
Required Control Inlet Group
Pressure Size
Oil Burner
Forced Oratt
Gilt Pump (KSH)
6' w.c. 6' w.c. 6' w.c 6* w.c 7' w.c
7' w.c. V w.c 8' w.c. 8' w.c 8' wc.
8' wc. 12'wc. 1?' w.C. 12* w.c
2VS 2VS' 254' 3' 3'
3' 4' 4* 4*
6'
6* 6' 6' 6*
1.0 1.0 1.0 1.5 1.5
1.5 3.0 3.0 3.0 5.0t
5.0i 5 0' 7.5* 7.5t
1.5 Vil
1.5 vs:
1.5 vs: 2.0 VS 2.0 vs 2.0 ss
3.0 V4
3.0 vs 5.0 vs 5.0 ss 7.5 vs
7.5 vs 7.5 vs 7.5 vs
Controls lor other pressures or insurance requirements available, tv-bell drive.
;230v . 60 cy.. 1 phase all ether motors 230v, 60 cy . 3 phase standard
Electric Oil Hceter
230v.
Watts Phese
2500 2500 2500 3750 3750
3750 5000 5000 5000 5000
5000 5000 5000 5000
1 1 1 1 I
1 3 3 3 3
3 3 3 3
Oil Pump Cepacity G.P.H.
KP KS
60 45 60 60 60 60 115 102 115 102 115 102 205 130 205 130 205 162 305 192 305 192 305 244 305 303 305 303
24367
low pressure
The contractor shall furnish and install.................... Number........................ Kewanee Forced Draft Scotch Package UniUst tor (oil) (gas) (gas-oil combination) firing. The unit(s) shall have a certified output rating of ....................... H.P. and shall contain not less than........................sq. ft. of heating surface (ASME, Fireside) and a minimum furnace volume of............. cu. ft The heat release shall not exceed 67,000 BTU per cubic foot of com bustion space when operating at certified output rating. The furnace diameter shall be no less than............. in., the diameter of the vent.............. in.
The shell shall be of the scotch type, two pass, horizontal firetube design, ASME Code construction for (15 PSIG steam) (30 PSIG water). The boiler shall be mounted on steel I-beam skid base with Integral forced draft burner and burner controls. The boiler shall be of the wet back type requiring no refractory in rear combustion chamber. An access door of at least 16' in diameter shall be provided to permit entry into the rear combustion chamber.
The furnace tube openings in the front and rear tube sheets shall be hot flanged to provide maximum strength at junction of tube sheets and circular furnace tube.
The boiler tubes shall be 3* O.D. and tube holes shall be reamed not to exceed Via' greater than outside tube diameter. All tubes shall be set with a roller expander and beaded at each end. Welded tube ends will not be permitted..
Boiler trimmings shall consist of the following, mounted and piped:
For Steam-Safety valve(s), steam gauge with siphon and shut off cock, Kewanee cast iron water column with water gauge and try cocks assem bly (chain operated water column trimmings on Unit No. SB and larger), combination water feeder and low water cut-off including alarm switch, angle drain valve.
For Hot Water-Relief valves, pressure gauge, thermometer, low water cut-off, angle drain valve.
Boiler shall be inspected during construction by an authorized inspector and after completion shall be subjected to a 60 lb. hydrostatic test and stamped with all identifying markings and symbols as required by the latest edition of the ASME Boiler Construction Code.
Unit(s) shall be provided with factory installed aluminum finished jacket of 22 ga. steel securely fastened with drawbands. Jacket shall have a 2* thick insulation of lightweight mineral or glass wool material of 3 lbs. density per cu. ft attached with adhesive. A similar material of 9 lb. density, 2* thick, shall be applied at selected locations for reinforcement including the top splice where it will form a 12* catwalk along the entire length of the boiler. Cover rings shall be provided at all openings. Lifting loops shall be provided so that unit may be handled without damage to the jacket.
The front smokebox shall be of heavy gauge steel welded to the boiler to secure a gas tight fit The flue doors shall be of cast iron* and gasketed to secure a gas tight fit with a minimum number of clamps. They shall be lined with refractory insulating cement securely keyed in place and capable of withstanding a temperature of 1500F. A damper with cast iron bearings and locking quadrant shall be furnished in the flue outlet.
Units 80 to 90 inel.--steel doors on 91 to 93 incl. Fuel burning equipment as follows shall be provided:
(Refer to Burner Specification)
HIGH OR'LOW PRESSURE UNITS
mounted and piped (baffled L'-tube oil preheater^ (safety type oil preheater) complete with necessary temperature control --(aquastat and circulating water pump) for low pressure units (steam trap, steam regulating valve, strainer, and steam pressure reducing valve) for high pressure units. A control shall be provided to permit continuous operation of oil pump and oil preheaters when burner is not running. NOTE: Specify oil tank heating system to be used.
fStrike out underscored items that do not apply.)
For gas-oil units
Combination Gas-Oil Burning Equipment shall include the following in addition to the items specified above Change over from one fuel to the other shall be accomplished by means of a manual fuel selector switch mounted on the control cabinet. No changes in linkage, burner position, or mechanical adjustments shall be necessary when changing fuels- Fuel selector switch shall provide, through the com bustion control relay, proper ignition timing for fuel being burned.
For all units
Fuel Burning Equipment shall be set and adjusted by a
Factory Authorized Service Representative to burn
................ G.P.H. of .. oil (and> (on
.. C.F.H.
of. btu cu. ft. (natural> tmfg.) gas having a
sp. gr. with. ..
inches W.C. pressure at inlet
of burner manual gas cock. Note: Specify job altitude if
over 3000 ft. above sea level.
For all units
Owner's representative shall be present to receive instruc tions in the care and maintenance of the Boiler Unit at the time the Boiler Unit is started up by the Service Rep resentative. Note: Specify free service period of not less than 90 days after start-up.
For all units
All motors shall be for
volts,
cycle,
phase. Controls shall be for .
volts,
single phase. Electric oil preheater shall be for
volts, .
cycle, . .
phase.
cycle,
Por u on multiple Installation* or for remote mounting
Select Pump Sets having capacity equal to approximately twice the burning capacity of the burner(s). Pump Sets Numbers 1 through 4 are equipped with mechanical seals. Sets 5 and 6 have packing type seals.
Pump Standard Sat on ASH Number Units C. P. H.
Rebef Valve Sue
Motor--HP
Port 754 Drscharie Pump
Sue
Pressure
PPM
IB SO 1C 11-12
45 60
K' K* V.' VT
2A 1314 45 102
V.' Yt*
26 46-4? 130 K* H'
2C SS 162 V.' H*
3A 89-90 192 I*
38 91 2U r
3C
92-93
303
i*
Y*' V.* V,`
4A
369 r
l*
48
434 r
r
C
472 r
r
SA 613 IVi* IV.* SB 720 IY.` IV.' SC 745 IV.* IV.'
6A 827 IV.* IV*' 66 970 IVi* l*' 6C 1060 IV.* IV**
A 452 v> 596 Yt 306 Yt 392 Yt 445 V* 306 v* 392 v* 485 v 306 Vi 360 Vi 392 1 306 1 360 1 392 IV* 306 IV* 360 IV* 392
STANDARD EQUIPMENT Pump jet consist! of Tutfntl pump pump base adjustable motor base V-belt drive, belt (uaid. relief valve motor--230v, 60 cy, 3 phase*. Linestarter* vacuum jauft pressure |au|e o<tsuatner
Sue I pumps are'/jhp. 230v 60 cy.. unji* phase No tmesfarfer included
24368
9
KEWANEE forced, draft package units
standard equipment
optional equipment
ALL UNITS
1. Wmdbox complete with refractory lining 2. Forced draft fan. motor, adjustable inlet vanes --230v, 60cy, 3 ph.
3. Air flow safety switch 4. Safety latch switch
5. Gas-electric ignition assembly 6. Pilot gas pressure regulator (except IP) 7. Modulating motor, transformer, linkage
8. low-fire start interlock 9. Modulating control 10. Operating limit control 11. Safety high limit control 12. Control cabinet complete with:
MH-R478-B (or Ftreye FP-2) electronic flame safeguard, motor starters, relays, trans formers. terminal strips, signal lights (4). etched name plates, manual switches, manual potentiometer, individually fused circuits 13. Boiler flue cleaner and handle 14 Boiler (ASME Code) mounted on steel skids 15. Gas-tight front steel smokebox with gasketed cast iron doors (Units 80-90) 16. Rear access opening with Pyrex observation port 17 3'firetubes with spinner blades 18. Quadrant locking outlet damper 19. Insulated steel jacket with reinforced catwalk area 20. Listed standard and selected optional equipment mounted, piped, wired ready for field connection to fuel, water, steam, and electricity 21 Factory fire test 22. Starting service
1. Electric characteristics other than 230v. 60cy. 3 ph. 2. Flue gas temperature gauge *3. Circuit breakers in lieu of fuse blocks 4. Alarm bell 5. DC voltmeter 6. Draft gauge *7. Sequencing draft control 8. One year service period
'Requires special control cabinet
1 Horizontal rotary cup oil burner --230v. 60cy. 3 ph. Direct Drive (Units 80-88) v-6eit Drive (Units 89-93)
2 Primary air fan
3 Magnetic oil valve
4 Electric ol heater 5. Oil strainer assembly 6 Oil check valve 7 Oil viscosity valve 8 Oil vacuum and pressure gauges
ALL OIL FIRED UNITS
1 Fuel oil meter mounted on burner 2 Increased capacity electric oil heater 3 Duplex oil strainer m lieu of standard strainer 4 Controls for FM requirements 5 Controls for FIA requirements 6 Controls for future addition of gas firing 7 Oiesel-electac ignition
1 Integral oil pump
(KPE) NO. 5 OR LIGHTER OIL UNITS
1. Separate oil pump set with V-belt drive, relief valve and manual-off-automatic control.
2 Omit electric oil heater lor No 2 and No 4 oil
(KSH) NO. 6 OIL UNITS
1 Separate oil pump set for remote mounting with V-Bett drive, relief valve manual-offautomatic control
2 Below-water-line oil heater (hoi water ant) low pressure sleam units) mounted complete
with water circulating pump and pump control 3. Steam oil heater (high pressure steam units) mounted complete with temperature regu-
latmg valve, trap, strainer, and steam pressure reducing valve
1 Separate oil pump mounted piper) and wired on boiler skid 2 Salety-tjpe betow-water tme oil heater in lieu ot standard
1 Multiple-jet ring type gas burner 2 Gas pressure gauge 3 UL approved low pressure gas control group
a gas volume control valve b Automatic motorized gas valve with safety end switch c Gas pressure regulator d Gas lubricated Qlug cock
ALL GAS UNITS
1 Gas control group for FM requirements 2 Gas control group for FIA requirements 3 Gas control group tor other than standard gas pressures 4 Gas control group for special local or utility requirements 5 Controls for tuture addition of oil firing
1 Manual fuel changeover switch 2 Changeover without mechanical adjustments or changes
GAS-OIL COMBINATION UNITS
1. Automatic fuel changeover control 2 Swing out oil burner to fire gas
1 Safety valve(s)
2 Steam gauge with siphon and cock 3 Hand operated water column trim (Units 80-87) 4 Cham operated water column trim (Units 88-93)
ALL STEAM UNITS
]. Cham operated water column trim in lieu of hand-operated (Units 80-87)
HIGH PRESSURE STEAM UNITS
1 Rear combustion chamber refractory
2 No. 157a or No 1570 combination water column, pump control, and low water cut-off
l. Second low water cut-off
3 Blow down valves
2 No 191D water column, pump control, and low water cut off m
4 In/ector
lieu of 157A or 1570
5 Corrugated furnace tube
3 Higher than standard 125 or 150 lb. S.W.P.
6 Globe and check valves for boiler feed lint
LOW PRESSURE STEAM UNITS
! Kewanee water column
2 Combination water feeder low water cut off and alarm switch
3 Wet back type construction i Angie dram valve
I Second low water cut-off
2 No 157A or No 1570 wafer column, pump control and low water
cut-off m Ueu of (or in addition to) standard column leeder and cut-off
3 No 191D water column, pump control, and low water cut-off m
lieu of (or m addition to) standard column feeder and cut-off 4 Instantaneous or lank type hoi water coils
! Water relief vaive(s)
1 Pressure gauge and thermcmetei
io
- low water cui-off 4 Angie dram valve
HOT WATER UNITS
1 Higher than standard 3D tbs water wor.ng pressure 2 instantaneous or tank type hot water coils
24369
Xewanee Forced Draft Scotch Package Units
Pump and Receiver for Steam Units
If specified, a Boil**r Feed Unit is included in the complete ship ment. This equipment is not attached to the boiler skids, allowing installation at the most convenient location in the boiler room. Sizes for every unit... 15,125, 150 lb. steam working pressures. M & M No. 21 feeder--100 gallon tank. Solenoid valve and float switch--larger tanks.
Simplex or Duplex Units
The Simplex Unit is illustrated. Duplex Unit consists of two pumps and two motors mounted on a single chassis with the tank. Duplex Units are often advisable for stand-by purposes or with a battery of two boilers; each boiler supplied by a separate pump.
boiler feed, units (dimensions--inches)
unit * 8 e 1 o | E| r G
KL
0PQ R s V
KXF 46 78 6341 73561 361 456 14 5 27 10'/. 28 116
9 18'4
3
KXG m 78 62 1 73 | 561 4'/, 14 V, 516 30 n 48 2 12 9 19'/. v 4
KXH m 78 60" 1 747,1 561 416 1716 7'/, 36 141* 48 2 15 9 20'* Vi 4
KXJ 66Vj
56 | 73 1 56| 6 20vi 8
42
48 2'/, 15 9 21J-i
KXK 9016 78 56 | 73 | 78| 6 20U 8
42 17 72 254 15 9 18 Vi 1
4
KXM
dimensions on request
Xz
3 p'i
3 V. 116
3 Vi 154 3'i
4 156
pump number
w
1133 143-149. 1141-1252
3751-3791
t
IVi
2
2V5-
250 lb. ASA RF Fig
All others ere standard screwed connections.
specifications and catalog: numbers
unit number
80 81 82 83 84 85
86 8? 88 89 90 91 92 93
boiler teed unit number
gpm--max 195*F
pump number motor sue, hp--rpm tank capacity--gal. shipping weight--lb
IS swp
boiler teed unit number gpm--mai 1959F. pump number
motor Size, hp--rpm tank capacity--gal shipping weight--lb
125 swp
boiler feed unrl numoer
gpm --max I95rf pump numoer motor size hp--rpm
tank caoactif--gal Shaping weight--ID
150 swp
KXF-l 10.5 143
56 1750 100 500
KXF-11 10 5 1133
3-3500
too
650
KXF-ll 105 1133
3 3500 100 650
KXF-l 12 6 143
54-1750 100 500
KXF-1J 12.6 1133
3-3500 100 650
KXF 21 12 6 1251
5 3500 100 650
KXF-2 KXF-102 15.5 18 2 145, 148
54-1750 56-1750
100 too
500 500
KXF-I2 154 1141
3-3500 100 650
xxr-12
182 114)
3-3500 100 650
KXF 22 154
1252 5 3500
100 650
Kxr-22
18 2 1252 5-3500 100 650
KXG* 1 22 4 148
56 -1750 200 700
KXG-20 22 4 1252
5-3500 200 850
KXG-20 22 4 1252
5-3500 200 850
KXG- 10 27.3 149
1-1750 200 700
KXG-8 273 1255
7V4-3500 200 900
KXG-21 27 3 2255
10-3500 200 1050
KXH-1 32 2 263
156-1750 250 950
KXH-20 32.2 1255
756-3500 250 1050
KXH-2I 32 2 2255
10-3500 250 1200
KXH-1 364 263
156-1750 250 950
KXH-22 36 4 1255
10-3500 250 1150
KXH-21 36 4 2255
10-3500 250 1200
KXM 45 5 265
2-1750 350 1050
KXJ-20 45 5 2257
10-3500 350 1400
KXJ-20 45 5 2257
10-3500 350 1400
KXJ-2 546 267
2-1750 350 1050
KXJ-20 545 2257
10-3500 350 1400
KXJ-21 54 6 2279
15-3500 350 1550
KXK-1 63 0 267
2-1750 500 1400
KXK-20 630 2283
15-3500 500 1650
KXK-21 63 0 2282
20-3500 500 1700
KXK-2 680 267
2-1750 500 1450
KXK-3 68.0 3751
15-1700 500
2000
KXK-3 68 0 3751
15-1750 500
2000
KXM-1
74 0 269 3-1750 750 2000
KXM-4
810 269 3-1750 750 2050
KXM-2 KXM-5 74 0 810 3771 3771
15-1750, 15-1750 750 750
2600 2500
KXM-3 KXM-6
74 0 81 0 3771 3791 20-1750 20-1750
750 750 2650 Z55U
24370
Authorized Service Representatives, located in local marketing areas, are trained service personnel; qualified to render prompt, efficient service on Kewanee Package Units.
The owner of a new Kewanee Forced Draft Scotch Package Unit receives Starting Service which consists of the initial startup of the unit, checking the general operation of the unit, making adjustments re quired by local job conditions, instructing the operator in proper maintenance procedures, and service for a period of 90 days after startup.
24371
AMERicAN-J$tandard
SALES 0"ice$ IN All principal cine*
Exacutiva Officaa: DETROIT 32, MICHIGAN
in Canada: American-Standard Product* (Canada) Limited. Toronto A. Ontario
AMERICAN RADIATOR A STANDARD SANITARY CORPORATION