Document qaDGy6apzZm2JQbkbB0pQzZV5

/iron ih* dttkof W. 8. PAPAGEORGE 8/30/71 Coplaa toi R. 1. KtlUu^ I. 8. Tueksr 8. V. HhMUt All is procsdurs ussd toy USDA to dstsralno PCS'* in poultry tissos. mr MS 0755 71 Detection of Polychlorinated Biphenyls (PCB's) In Adipose Tissue Tile acetonitrile partition, described in the attached method, roquiros a minor modification to insure a quantitative recovery of the PCB's. At the end of the acetonitrile partition, the petroleum ether extract should be concentrated to 25 ml and transferred to the florisil column after the column has been washed with 150 ml of petroleum ether. (Discard wash as soon as the petroleum ether extract is placed on the column). If multiple unknown peaks are present on the final chromatogram, PCB's may be present. MCNS 075573 Quantitation of Polychlorinated Biphenyls (PCB's) in Adipose Tissue The attached chromatograms indicate the method which should be used for quantitation. As shown, 12 peaks from sample 1 were matched (same retention time) with 12 peaks from the PCB 12k2 standard, and the peak height of each one was measured. The Bum of the heights of the identifiable peaks from the sample was divided by the Bum of the heights of the corresponding peaks from the 5 nanocram standard. Since the injection represented 1 mg. of Bample, the concentration of PCB 12h2 was 1.9 ppm in this sample. You may or may not be able to match as many peaks as are shown on the attached chromatograms. For proper quantitation, however, you should use as many peaks as can be properly matched. HONS 075574 MGNS 0 7 5 5 7 5 44 CHLORINATED ITYDROCAKBON ANALYSIS Since chlorinated hydrocarbon pesticides are 6tored in a fat, or fatty tissue, all such analyses are reported on the basis of the extracted or rendered fat, THEORY The sample is dissolved in petroleum ether and extracted vith acetonitrile. The acetonitrile extracts are diluted with water to partition the pesticide residues into petroleum ether. The residues are purified by chromatography on a Florisil column, eluting with mixtures of petroleum and ethyl ethers. Residues in the concentrated eluates* arc measured quantitatively by gas-liquid chromatography or semi-quantitatively by thin layer chromatography. Identification is by a combination of gas-liquid and thin-layer chromatography. APPARATUS ' (a) Chromatographic columns. With teflon stopcocks and coarse fritted ,:late, 22mm id x 300 mm. (b) Alternate column - Chromatographic columns without stopcocks. With coarse fritted plate, 22mm id x 300 or 400 mm - (when this column is used, it is topped with anhydrous sodium sulfate powder for flow control). (c) Filter tubes. Approximately 22mm x 200mm with a short delivery tube and a coarse fritted plate (a glass wool plug can also be used). " HONS 075526 44 (con. f 1) (d) Kuderna-Danlsh Concentrators. Five hundred nil with 5 or 10 ml volumetric receiving flasks or graduated tubes (Kolmer or Mills types; Kontes Glass Company, Vineland, New Jersey 08360, Catalog No. K-570000, K-621400, or equivalent.) (e) Alternate concentrator. If the solutions can be made to a volume of 25 ml, an erlcnmeyer flask with a 24/40 S joint with a three ball Snyder column may be used. (f) Separatory funnels. Teflon stopcocks - 500 ml and 125 ml. ' (g) Thin layer apparatus and accessories. Desaga/Brinkman apparatus for thin layer, or equivalent. " (h) Chromatographic tank and accessories. Arthur H. Thomas Co,, Vine Street at 3rd, Philadelphia, Pa. 19105, No. 3106-F05, or equivalent, with metal troughs. (i) Ultra violet light source. Four germicidal lamps, 15 watt, 18" long mounted in a metal cabinet 20" x 10" x 10" to accommodate two glass plates. (j) Gas liquid chromatograph. Barber Colman Model 5000 or equivalent with electron capture detector, power supply, electrometer and 5 mv recorder. . (k) Columns. Six feet * four mm id (approximately) packed with 10 percent DC-200 on 100-120 mesh Anakrom ABS, (Analabs Inc., Post Office Box 501, North Haven, Connecticut 06473) or 3 percent JXR on 100-120 mesh. Gas Chrom Q, (Applied Science Laboratories, State College, Pennsylvania 16801). The column should be conditioned at 250C with a nitrogen flow of 100 to 120 ml/min until endrin emerges as a single peak. HONS 075577 (1) Alternate column - 6'x 4 mm (approximately) packed with 3 percent QF1 and 1 percent DC-200 on 100-120 mesh Gas Chrora Q. The column should be conditioned at 200C. QF1 bleeds excessively at higher temperatures. (If this column is used, the 6 percent and 15 percent elutions may be combined). SOLVENTS '' Some solvents, sold as suitable for use as received, arc available from many manufacturers, and arc usually identified as Nsnogradc or chromatographic grade. All solvents, however, must be tested prior to use to determine whether purification is required. This test is to be performed as outlined on the following page. Those solvents requiring purification must be distilled in an all-glass apparatus. However, if Nanograde or chromatographic grade solvents are found to require purification, they should be returned to the supplier with a request for replacement, since their high cost is predicated upon purity. CAUTION Ethers (excluding petroleum ether) containing unsafe concentrations of peroxides can detonate when they are distilled or concentrated. No quantity of ether, therefore, should be so treated before the following teat is performed: "Shake one ml of a freshly prepared saturated solution of K1 with nine ml of ether in a 25 ml glass stoppered cylinder. Any yellow color Indicates a concentration of peroxide greater than 0.005 percent." HONS 075578 I 44 (con. If 3) Such a concentration Is dangerous, and ether containing this level of peroxide should be discarded, or returned to the supplier with a request for an exchange. ' Purity Test Electron capture gas chromatography requires the absence of substances causing any detector response from the following test: Place 300 ml of solvent in the Kuderna-Danish Concentrator fitted with a three-ball Snyder column and a calibrated collection tube and evaporate to five ml. Inject five ul of concentrate into the gas chromatograph using operating conditions described in the paragraph, "Residue Detection Method - Gas Chromatography." Concentrate must not cause recorder deflection one mra from base line for 1-60 minutes after injection. If thin layer is used for semi-quantitative analysis, 50 ul of the concentrate is spotted on the plate, developed, aprayed and exposed to UV light as described in the paragraph, "Thin-layer chromatography." There should be no spots visible. MGNS 075579 44 (con, # 4) . REAGENTS (a) Acetonitrile. Practical Eastman Organic Chemicals (our experience has been that it seldom requires purification). If purification is necessary, purify as follows: m To four liters of acetonitrile add one ml of U3PO4, 30 grams PjO^, a ^ew foiling chips and distill in all , glass apparatus at 81-82C. DO NOT EXCEED 82C. (b) Acetonitrile saturated with petroleum ether - Saturate CII3CN with petroleum ether (g), A small layer of petroleum ether should just be visible on the CH^CN. (c) Eluting solvent, 6 percent - Dilute 60 ml ethyl ether (c) to one liter with petroleum ether (g). (d) Eluting solvent, 15 percent - Dilute 150 ml ethyl ether (e) to one liter with petroleum ether (g). " (e) Ethyl ether - Reagent or ACS grade. (See Caution under Solvents). () Florist 1 - Pesticide.Residue grade (60-100 mesh) Florldln Company, 2 Gateway Center, Pittsburgh, Pa. 15222. Activate not more than a two-day supply of Florlsil by heating at g50C for two hours (caution: DO NOT EXCEED 650C), Transfer while hot (use beaker tongs, asbestos gloves and funnel) to erlcnmeycr flasks. Stopper loosely with aluminum foil wrapped corks and cool in a desiccator stored in the dark. ' _ MOSS 075580 44 (con. # 5) Standardization of Florisil Reagents _ Indicator. Dissolve 1 gm of phenolphthaleln In ethyl alcohol and dilute to 100 ml. Ethyl alcohol, neutralized to phenolphthaleln. Laurie acid solution. Dissolve 10.000 gros lauric acid in distilled hexane and dilute 500 ml. 0.05N NaOH - Dissolve 2.000 gms sodium hydroxide in distilled ,, water and dilute to one liter. Standardized NaOH solution - Flpct 10.0 ml lauric acid solution (200 mg) into a 125 ml erlenmeyer flask. Add 50 ml of neutralized ethyl alcohol, three drops of Indicator and titrate with 0.05N NaOH to a permanent end-point. Calculate mg lauric acid per ml 0.05N NaOH. - Procedure Transfer 2.000 g activated Plorisil to a 25 ml l erlenmeyer flask. Add 20 ml lauric acid solution (400 mg), stopper and shake occasionally for 15 minutes. Let adsorbent settle and plpet 10.0 ml of supernatant into 125 ml erlenmeyer flask. Avoid inclusion of any Florisil. Add 50 ml neutral ethyl alcohol and three drops of indicator solution; titrate with 0.05N NaOH to a permanent end-point. Calculate amount of lauric acid adsorbed on Florisil, (Lauric Acid Value), as follows: Mg Lauric Acld/g Florisil 200 -- (ml required for titration x mg Lauric Acld/ml 0.05N NaOH.) MCNS 075581 44 (con. tf 6) A lauric acid value of 110 is the acceptable value; i.e., 20 g of Florisil would fill a 22mm i.d. column to a depth of 110mm. To obtain the equivalent quantity of Florisil, divide 110 by the Lauric acid value for that batch and multiply by 20: 110 x 20 g Florisil required. LA V The columns are prepared as in the clean up technique, and prewashed with 100 ml petroleum ether. A 1 ml aliquot of mixed pesticides containing 0.2 Ug lindane, 0.4 ug heptachlor epoxide, 0.6 ug dlcldrin and 0.6 ug endrin is placed on the column. The columns are eluted also as in the clean up technique. The eluatea are concentrated, transferred to 25 ml volumetric flasks and made to volume with petroleum ether. One ml of the mixed pesticides is also diluted to25 ml with petroleum ether In a volumetri flask. Inject 5 ul of the standard and of the two eluatea into the gas chromatograph. The recovery of thepesticides when compared to the standard must be at least 95 percent and lindane and heptachlor epoxide must be io the six percent elution while dieldrin and endrin must be in the 15 percent elution. (g) Petroleum ether 30- 60C, boiling range. (h) Sodium sulfate - anhydrous granular; anhydrous powder. (1) Aluminum oxide - AI2O3G available from Warner-Chilicott 'Laboratories, Instruments Division, 200 South Garrad Blvd., Richmond, California 94801. AI2O3G neutral, available from Merck & Co., Rahway, New Jersey 07065. M0NS 075582 44 (con. # 7) ' ` (J) Developing jsolvents - (1) n-heptane, commercial - grade (no purification . required) (2) n-heptane, commercial grade, containing 2 percent acetone, reagent grade. (k) Chromogcnic agent - Dissolve 0.100 grams AgNOj in 1 ml l^O, add 20 ml 2-phonoxyethanol (Practical, Eastman Organic Chemicals), dilute to 200 ml with reagent grade acetone, add one very small drop of 30 percent H2O2 and mix. Store in dark over night and decant into epray bottle. Discard after four days. (l) Standard solutions for thin-layer chromatography. (1) Stock solutions and A^ (mixture of aldrin, lindane heptachlor epoxide and methoxychlor). Weigh 0.1 gram of each pesticide into same 10 ml glass stoppered ` volumetric flask. Repeat with 0.03 grams of each into a second volumetric flask. Dissolve in ethyl acetate, dilute to 10 ml and mix. One ul of each solution contains 10 ug and 5 ug, respectively, of each * pesticide. (2) Stock solutions B^ and B (mixture of B11C, DDE, DDD, . ` DDT, dieldrin, and endrin). Prepare solutions of 10 and 5 ug/ul as in (1). ` (3) Dilutions of stock solutions: From the stock solutions prepare dilutions containing 0.2, 0.1, 0.03, 0,02, 0.01, 0.005 and 0.002 ug/ul. MGNS 075583 44 (con. # 8) (m) Individual Standards. Separate standards of each insecticide should be prepared at 0.1 ug/ul concentration so that the migration of each insecticide can be determined and the insecticide can be identified in the mixtures. (n) Gas liquid chromatography. The individual standards from (m) are diluted so that a five ul injection will contain approximately 0.25 nanogram of heptachlor epoxide and will give approximately 50 percent of full scale deflection on the ,, recorder. The concentrations of all other insecticides should be adjusted accordingly: Lindane and BHC should be approximately 1/2 of the heptachlor epoxide; dieldrin, endrin and DDE should be 1--1/2 times; DDD should be about twice, DDT about 4 times and methoxychlor about eight times. This Is approximate, and must be determined for each gas liquid chromatograph used. ^ (o) Gqs liquid chromatography mixture standards. After retention time and response have been determined for the separate insecticides, prepare mixtures so that the compounds will not Interfere with each other, i.e., BHC, DDE, DDD and methoxychlor In one solution; lindane, aldrin, heptachlor epoxide, dieldrin and endrin In another. The concentrations should such that a 5 ul injection produces a 1/2 scale recorder deflection. HONS 075584 44 (con. # 9) . DETERMINATION: Sample Preparation , Fatty tissue. Pass chilled sample through food chopper twice. If dry ice is available, add small quantities to fat to maintain a low temperature. Plug a powder funnel moderately tight with glass wool; place approximately 100 grams of the comminuted fat in the funnel; position the funnel in a beaker and render at 125C until the fat ceases to drop. Muscle tissue. Pass sample through food chopper three times. Grind suitable quantity with anhydrous Na2S04 to combine with moisture in sample. Transfer granular mixture to centrifuge bottle, add 100 ml petroleum ether, shake vigorously and centrifuge about 5 minutes at about 1S00 rpm. Pour off solvent layer into beaker and re-extract residue twice with 50 ml portion of petroleum ether. Evaporate combined extracts to obtain fat. All chlorinated hydrocarbon residues are reported on the basis of the rendered or extracted fat. Acetonitrile Partitioning Heigh 5 grams of melted fat into a 50 ml beaker, add 10 ml of petroleum ether and transfer to a 125 ml separatory funnel. Use an additional 15 ml In smallportlons to rinse the beaker for a quantitative transfer of the fat. Add 25 ml of acetonitrile saturated with petroelum ether and shake vigorously for 1 minute. Let layers separate (adequate time must be allowed to obtain a good separation). It Is a good idea to plan to use the time _during the separation for a subsequent operation - i.e., during the first extraction, the preparation of the 500 ml separatory funnels containing the MQNS 075585 N >*.- :ti 44 (con. if 10) * petroleum ether and 2 percent Ha2S0^. Drain the bottom (acetonitrile) layer Into a 500 ml separatory funnel containing 300 ml of 2 percent NajSO^ and 100 ml of petroleum ether* Extract the petroleum ether solution in the 125 ml separatory funnel with 3 additional portions of acetonitrile saturated with petroleum ether, shaking vigorously 1 minute each time* Combine all extracts in the 500 ml separatory funnel. Stopper, invert the 500 ml separatory funnel, vent pressure, and shake gently 1 minute to transfer the pesticides to petroleum ether. Let layers separate cleanly and discard lower aqueous layer. Wash the petroleum ether in 500 ml separatory funnel with two 50 ml portions of 2 percent t^SO^ (after addition of 2 percent Na2S0^, stopper, invert and vent. Occasionally,excessive pressure will build up). Discard washings and draw off petroleum ether layer through a 2" column of anhydrous granular Na2S0^ in the filter tube into a 250 ml erlenmeyer flask. Rinse the separatory funnel and the column with two 10 ml portions of petroleum ether. (The total elapsed time for the acetonitrile separation should be approximately 2 hours). Clean On Technique Florisil Column * Prepare 22 mm Id florisil column, containing 100 mm after packing of activated florisil topped with about 1/2" of anhydrous sodium sulfate (110 nm should pack to 100 ram). Transfer petroleum ether extract to colunn, letting it pass through the column at a rate not to exceed 3 ml/min (optimum rate is approximately 2% ml/min). When the last of the petroleum ether has sunk Into the colunn, change receivers and elute with 110 ml of 6 percent M0NS 075586 44 (con. t IX) ethyl ether in petroleum etherfat the same rate. Change receivers and elute with 110 ml of the 15 percent ethyl ether in petroleum ether. Concentrate each eluate to 5 ml using the Kuderna-Danish or alternate concentrator. Transfer each eluate quantitatively to a 25 ml volumetric flask and made to volume with, petroleum ether. When the elution from the florisil column la hold to the low rate specified, the insecticides are eluted quantitatively from the column and both eluates are suitable for thin-layer or gas-liquid chromatography. ' First eluate (6 percent) contains aldrin, BHC, DDE, DDD(TDE), o,p*- andjp,p'-DDT, heptachlor, heptachlor epoxide, lindane and raethoxychlor. Second eluate (15 percent) contains dleldrln and endrin. Residue Detection Method Gas Chromatography Operating conditions for 10 percent DC-200 or 3 percent JXR column. Injection temperature 220C, column temperature 185 to 200C, detector -temperature 210C maximum, carrier gaa flow 120 ml/min nitrogen. Detector voltage 24 to 40 volts; exact voltage must be determined for each chromato graph to obtain the maximum sensitivities. Operating conditions for mixed column - 3 percent QF1 and 1 percent DC-200. Injection temperature 200C, column temperature 170 to 185C, detector temperature 200to 210C. Carrier gas flow 100-120 ml/stin nitrogen. Detector voltage 24 to 40 volts; exact voltage must be determined for each chromatograph. ' Check the linearity of the system. Determine the individual retention times of the Insecticides. Make calculations only from peaks that arc in ' the linear range. HONS 075587 44 (con. t 12) . Inject a suitable aliquot (3-8 ul) of the eluates from the 25 ml volumetric flask into the chromatograph using a 10 ul syringe. If peaks are out of the linear range, re-inject using n smaller aliquot or dilute to bring the response into the linear range. Tentatively identify residue peaks on the basis of retention time. Measure areas under the peak or peaks from the unknown and compare to the areas obtained from known quantity of the standard insecticide. For most accurate measurement, unknowns and standards should be of similar size and in the linear range. Chromatograph the standard pesticide immediately after the sample. Alternatively, it is possible to use only peak heights with a slight loss in accuracy, but good judgement is required, and it is very important that all measurements be in the linear range of the detector. Thin-layer Chromatography - A. Preparation of adsorbent Layer Select five 8" x 8" double strength window glass plates of uniform width and thickness and smooth off the corners and edges with a file or other suitable instrument. Before coating, wash the plates in hot soapy water and thoroughly rinse with distilled water. Press the plates snugly into position on the mounting board which has a retaining ledge on one side and one end. The plastic board is mounted so that its long side with raised ledge faces the operator while the short side with ledge is HONS 075588 - : ( (* \ ) , I 4 * . | jj i 1 l i 4 'i 4 1 44 (eon. # 13) to the right of the operator. Before coating, the surface of the plates are wiped with a few ml of 93 percent ethanol on a tissue to remove fingerprints or other adhering material. Position the applicator, trough open, with the left edge 1/4** in - from the edge of the first plate to be coated. To coat 5 plates, weigh 30 gms Al^O-jG into a 250 ml S crlenrocyer flask. Add 50 ml distilled water, stopper fla6k and shake moderately for 45 seconds. Violent shaking produces bubbles resulting In a ''pock marked" layer. Note: Suspensions which contain adsorbent with binders set rapidly and the entire procedure from the preparation of the slurry to the final coating must be completed within 2 minutes. After shaking, immediately pour the slurry into the applicator chamber. Rotate the chamber by turning the large level handle through o --- 180 C, After a few seconds, the slurry begins to flow out of the exit silt. Grasp the applicator with both hands and pull it manually with a steady motion across the series of plates. Approximately 3 seconds are required for the actual coating procedure. Immediately after application, - tap the edge of the mounting board or shake the entire board gently to ` smooth out slight ripples or imperfections In the wet coating. Let coated plates dry in position on mounting board for 15 minutes. Then dry plates in a forced draft oven at 80C for 30 minutes. Remove plates and cool. ' '` < ` . HONS 075589 44 (con. # 14) Examine the plates carefully In transmitted and reflected light for Imperfections or Irregularities In the coating. Plates should be discarded If extensive rippling or mottling of the layer is observed. Five more 8"x8" plates may bd prepared while the first set Is drying.' Be sure the applicator is thoroughly cleaned and dried before reusing. The 10 coated end dried plates may be prewashed Immediately. B. Prewashing of Adsorbent Layer Scrape 1/2" of adsorbent off the edge of the plate with a razor blade. Then pour IS ml 50 percent aqueous acetone into a metal trough inside the chromatographic tank. Cut out a 3/4" x 8" strip of Whatman Mo. 1 filter paper, wet with solvent and place over the scraped off portion with 1/4" overlapping the adsorbent layer. Place the plate in the chromatographic tank, seal tank with masking tape and develop with 50 percent aqueous acetone to within 1-1/2" from the top of the plate (75-90 minutes). Remove the plate from the tank, remove filter paper wick, invert the plate, and dry in the hood for 5 minutes. Dry the plate at 80C for 45 minutes. Remove plate from oven, cool and store in desiccator until needed. The prepared plates should be used within one week after preparation. C. Sample Spotting A pencil mark is made 1-1/2" from the bottom of the plate at both sides. An imaginary line between the two points Indicates the ample spotting or origin "line". Draw a line (which removes the coating) HONS 075590 44 (con. t 15) . . completely across the plate 5-1/2" from the bottom edge. This line represents the solvent front after development. On the lower edge of the'adsorbent starting 3/4" In from the left edge of the plate make IS marks with a pencil at 6/16" intervals. (Fewer marks with greater intervals nay be used if desired). The marks serve as horizontal guides to sample application. The identity of samples and standards may be etched directly into the adsorbent layer above the solvent front line and in alignment with these marks. The imaginary spotting "line" is actually a shadow line cast by a strong light source from a wooden ruler supported 1" above the plate. The ruler shadow is allnged on the two 1-1/2" marks on either edge o the plate. The shadow line and 18 marks respectively serve as vertical and horizontal guides for sample application. For optinum semi-quantitative estimation, adjust aliquot of sample spotted to give residue spot within the range .005 ug to 0.1 ug. Con centrations of standards and standard mixtures spotted should be .002, .005, .01, .02, ,05, .1 and .2 ug. Sample spots greater than .2 ug are difficult to estimate quantitatively and less than .005 ug may be difficult to distinguish. The volume of sample extract spotted should not exceed 10 ul if possible and spotting should be done repeatedly with a 1 ul Xontea potting pipet, or equivalent. Standard and sample solutions should be (potted with the same pipet, but the pipet must be cleaned between spottings For the best results keep the size of spotted sample as small as possible. All 6 percent extracts are spotted on one plate and 15 percent extracts arc spotted on another plate. HChS 075591 44 (con, # 16) Spot standard solutions of pesticides (mixtures A&B or single compounds) in different positions on the same plate. Tho choice of pesticides to be used for identification may be governed by the pesticide residues to be expected in the sample examined. For semiquantitative estimation, varying amounts of knowns may be chromato graphed from spots adjacent to samples. D. Development. Spraying and Exposure of Plates ' 1. Development ' Place liners and metal trough in tank. Presaturate liner by pouring 75 ml developing solvent into bottom of tank prior (30 minutes or longer) to developing plate. Presaturation decreases development time end Improves uniformity of R.f values. Por plates spotted with 6 percent extracts, pour 50 ml n-beptanc Into the trough. Place the lower edge of the plate in the metal trough with the top of the plate leaning against the side of the tank. Place the glass cover plate on the tank and seal with masking tape. For plates spotted with 15 percent extracts use 2+98 acetoneheptane as developing solvent. When the solvent front just reaches the pencil line 10 cm above the spotting "line", remove the plate and dry in hood for 5 minutes, v MOMS 07559Z 44 ' (con, # 17) "2. Spraying Support plate on one aide and spray fairly heavily with the chromogcnlc reagent, using lateral notions of the spray bottle perpendicular to the direction of solvent flow. Spray until plate appears translucent or soaked with reagent. Under-spraying will result In poor sensitivity. After spraying, dry the plate In the hood for IS minutes, then place immediately under ultraviolet light source. . 3. Exposure Expose the plate to ultraviolet light until the spot for the standard of lowest concentration appears. Five nanogram quantities of most of the chlorinated organic pesticides should be visible after 15-20 minutes exposure. Exposure times in excess of 30 minutes will not harm the plates. For best results place plates 3" from the botton edge of the germicide tubes. HONS 075593 M (con. # 17) . '2. Soravinn Support plate on one aide and spray fairly heavily with the chromogcnic reagent, using lateral motions of the spray bottle perpendicular to the direction of solvent flow. Spray until plate appears translucent or soaked with reagent. Under-spraying will result in poor sensitivity. After spraying, dry the plate in the hood for 15 minutes, then place lnmedlately under ultraviolet light source. 3. Exposure Expose the plate to ultraviolet light until the spot for the standard of lowest concentration appears. Five nanogram quantities of most of the chlorinated organic pesticides should be visible after 15-20 minutea exposure. Exposure times in excess of 30 minutes will not harm the platea. For beat results place plates 3" from the botton edge of the germicide tubes. HONS 025593