Document qa3oQ9vb5w5XqzQXgddy27BGj

Tennern Phem-i r a 1 s , Tnr (COMPANY) JKE-4-77 TO: FOR: D. R. Keck FROM: J. K. English RE: TANDEM AND DOUBLE SEALS FOR PVC PLANT TO MEET EPA REQUIREMENTS FOR VCM EMISSIONS Jjt - INTEROFFICE COMMUNICATION DATE: March 17, 1977 As we discussed, I have attached drawings and specifications of the tandem/double seals installed at the PVC plant. Also included is some additional information which might be helpful (JKE-3-77 and CAR 77086 - 77097 Job Instructions). No modifications were required to the pumps (stuffing boxes, etc.). The primary reason for selecting tandem seals over double seals (except on PC1-H302 and -303 Nash vacuum compressors) was to prevent any seal buffer fluid (water) from leaking into the process. We currently have all the seals in operation except on PC1-H302 and -303 Nash compressors and Z36-G103A & B VCM vaporizer pumps (G103A & B installa tion scheduled for completion prior to April 1, 1977 and H302/303 prior to June 15, 1977). Advise me if I can be of further assistance. JKE/mm Attachments cc w/attachraents: C. E. Crain -'-kT'e. Harmond p. R. Prokish L. Cox T. T. Moore E. J. Hourihan S. E. Richter R. D.. Mullen Engineering Equipment Files COLORITE 018282 TN ( 1/7 Pump PC1-G385A/B Service Crude VCM Pump Model Durco MK II GR II Seal & Code Dura-Tandem 1-7/8 PTO - 1-1/2 RA EU/M5EFW Drawing No. 2D-151788 PC1-G386A/B VCM Reflux Durco MK II GR 11 Dura-Tandem 1-7/8 PTO - 1-1/2 RA EU/M5EFW 2D-151788 PC1-G387A/B Recovered VCM Delivery Durco MK II GR II Dura-Tandem 1-7/8 PTO - 1-1/2 RA EU/M5EFW 2D-151788 PC1-G388A/B VCM Charge Union VLK Group II Dura-Tandem 2-1/8 PTO - 1-7/8 RA EU/M5EFW 2D-152575 236-G8 & G9 VCM Transfer BJ VLT Dura-Tandem 1-1/2 PTO - 1-1/4 RA Cartridge 2D-152622 Z36-G103A/B VCM Vaporizer Durco MK II GR I PC1-H302 & H303 VCM Recovery Compressors Nash CL3002 Dura-Tandem 1-1/8 RO - 1-1/8 RA EU/M5EFW John Crane Double Type 8-1 Q/XF-171 Not re CS SP 59640 COLORITE 018283