Document qa1w5v1Be37w0b33ZBEqaZ3rR

.. '> INTEROFFICE CORRESPONDENCE SUBJECT: ^UPDATED ASBESTOS'; QuicKTfES? date: December 18, 1979 OFFICE: Radnor FROM: J. M. Haas TO: J. R. Blackerby F. J. Cebula K. E. Eaton R. Figueroa R. E. Hammitt B. Hatfield C. Milburn G. W. ReedT Andy Becker Doy3e Stegall Duncan Marcus Hook Tulsa Yabucoa Dallas Sarnia Corpus Christ! Toledo Chester Dallas .The NIOSH procedure for asbestos determination has been updated. Please take this copy to your assigned chemist and mark old copy "outdated." Call with any questions. JMll:dhs 2/6 Attachment cc: D. Camin - Marcus Hook SUN-7<*00-fc . / ;/ . * r A 0001460 TEST FOR SCREENING ASBESTOS Walter S. Kin .James W. Carter, II Richard E. Kupel- U.s; DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE-* Public Health Service- .. Center for Disease Control '' National Institute for Occupational Safety and1 Health Division of Physical Sciences and Engineering Cincinnati, Ohio A5226 October 1979 A 0001461 1 TEST FOR SCREENING ASBESTOS I. SCOPE AND APPT,I CATION This colorimetric test is applicable to the detection of magnesium (II) and iron (II). from .asbestos in bulk samples. These samples include sprayed on asbestos as well as ceiling tiles. The test is. simple, and can be readily used in the field to screen for the presence or absence of asbestos. The amount.of the sample needed for the test is only about the size of a large pea. II. PRINCIPLE ' . The te^tj is based upon the formation of Qlor complexes with Mg and Fe released from asbestos.- The wB**+2from chrysotile is conplexed with p-n'itrophenylazo~a-naphthol. The Fe` from crocldolite and amosite is complexed with 1,. lO-phenanthrolirte.^A- positive+t;est is indicated by the formation of colored complex for Mg and/or Fen , and it indicates possible presence of asbestos. . III. INTERFERENCES The test is a colorimetric spot tes.t for Mg+2.. and Fe'+2 , and'is not specific for asbestos. . , ft ' A bulk sample may contain Mg and Fe compounds other than asbestos. Without treating the sample as in the Procedure, a few drops of color . forming reagents, are added directly-to the sample. If either color forms, an interferring substance is present and the sample must be cleaned before the test is conducted to eliminate the interference. In this cleaning process, plaster, mineral wool, fiberglass, and soluble Mg and Fe compounds are removed before the screening test, preventing their interference. '. IV. SENSITIVITY, PRECISION, AND ACCURACY A sample containing more than 1% asbestos gives a positive color reaction. . .... A total of 198 various field samples were tested before the Acid Wash steps were added to the Iron Test procedure. Results arc listed be low: Results of the screening test, without the Acid Wash. No. of . Samples % of Total True Positive 79 t False Positive 50 AO 2_ 1 > ' 1 .i True Negative 69 i f f. i a ! False Negative 0. 0 WWWMWJIl*** A 0001462 With the Acid Wash, the following results wore obtained from 13 samples. ..... Results of the screening test with the Acid Wash. True Positive False Positive True Negative False Negative No, of Samples % of Total APPARATUS 5 "38 .0 0 8 . 62 .. 0 0 t ?* 1. Teflon dish or white plastic plate 2. -Plastic or glass rod 3. Dropping plastic pipet .4. 15 tnL disposable plastic beaker 5. 25 mm size 0.8 ptu mixed cellulose ester filter 6. 25 nun size polyvinyl chloride filter 7. 25 raru Suinnax filter holder and gasket 8. 10 ml. disposable plastic syringe ..... , YI. REAGENTS (Reagent Grade) % * * 1. Phosphoric acid, concentrated. 2.. 10 N sodium hydroxide - Dissolve 40 g of NaOH in 100 mb of water. 3. Mg Reagent - Dissolve 1 mg of p-nitrophenylazo-a-naphthol in 10Q BtL of 2 N NaOH. Age at least a day. This reagent.is stable oyer a month. .' * /'* `4, Hydrofluoric acid - Dilute 20 mb of HF with 20 mb of water. "Add 0..6 mb of concentrated HC1. 5. 3?e Reagent - Dissolve 2 g of 1,10-phenanthroline in 50 mb of ethanol. This reagent is stable over a month. 6. Giycerin, reagent grade. 7. Acetic acid, concentrated glacial. 8* Sulfuric acid, concentrated. 9. Double de-ionized water. A 0001463 , -VXI. PROCEDURE A, Magnesium Test ' 1. Add a few drops of Mg Reagent directly to the sample. If . blue color appears, wash the sample with glycerin before. the test. Any sample containing plaster is also washed with glycerin. Glycerin Wash ' a. Place a .small portion of sample', about the size of a . large pea, in a plastic beaker. b. Add 5 drops of glycerin and mix well with a plastic rod or spatula. c. Rinse the plastic rod v.ith a small amount of water into the beaker. . d. Kilter the sample through the filtration assembly consist ing of a syringe attached to the Swinnex filter holder loaded with a mixed cellulose ester filter' and a gasket. 9 e. Kilter with a minimum of 5 .washings or about 50 rob of water. . . Transfer the filter to a Teflon dish for the Magnesium test. ' * . . 2. 3. Add a drop of lLjPO^, an<* m*-x ws^ 'jy grinding the sample with a plastic rod. ** * , Add 2 drops of 10 N NaOH and mix well. 4. Add 5 drops of Mg Reagent and stir briefly. Note any color change. . 5. Add 5 more drops of Mg Reagent and observe the final color. 6. A blue color indicates that chrysotile may be present. 7. Samples giving a positive test may be sent to a laboratory for confirmation. If the magnesium test is negative, the sample roust be tested for iron. . .. B. Iron Test 1. Add few drops of Fe Reagent directly to the sample. If a red ' co3or appears, wash the sample with the acetic--sulfuric acid mixtura before the test.- Samples containing fiberglass or mineral wool are also washed with the acid mixture. A 0001464 Acid Wash - . . 1. Place a small portion of the sample, about the size of a large pea, in a plastic beaker. 2. Add 5 drops of concentrated acetic acid. .1 3. Add 5 drops o.f concentrated sulfuric acid. 4. Mix well and ultrasonicate if available for 5 minutes. 5, Filter the sample through a polyvinyl chloride filter with a minimum of S washings or about .50 mL of water. * 2. 6,. Transfer the filter to a Teflon dish a.id proceed vith the Iron Test. . i * ' Add a drop of UF solution and mix well. 3. Add 5 drops of ye Reagent and observe the development of red- color! 4. The red color indicates" that amosite or crocido'lite may be present. ...... C. Notes . If both parts of the tes.t give negative responses, there is a low . probability that any asbestos is present. Once the presence of mag nesium and/or'iron is indicated, further analysis, if. needed, is done in the laboratory to confirm, identify the'type,'and quantitate the percentage of asbestos. VIII. REFERENCE ' 1. Caution:__ Asbestos Dust.. A scripto'graphic booklet by Channing L. liete Co., Inc., Greenfield, Hass. Prepared in cooperation with U.S. DHEW, PUS, CDC, National Institute for Occupational Safety and Health, Cincinnati, Ohio (1973). . ' 2. Fritz Feigl: Spot Tests - In Inorganic Analysis. Translated by Ralph K. Oesper. 5th Edition. Elsevier Publishing Company, Amsterdam. (1958) p. 225-227. 3. Walter S. Kim, James W; Carter, II, and Richard E. Kupel: Quick Screening Test for Asbestos. U.S. HHEW, PIIS, CDC, NIOSH, Cincinnati, Ohio. To bn published in AIIIAJ. ' A 0001465 Find Out Fast If It's Asbestos Whenever there are many sites to survey for as E-C Asbestest Kit contains enough materials for bestos, save time and money with the E-C AsbestestTM 55 tests. Nothing else is needed. Typical tests can be asbestos detection kit. run in 5 minutes. ECHO Asbestest Kit... $125 f.o.b. Many industrial hygienists at refineries and chem St. Petersburg, FL. ical plants use it for inexpensive "go/no go" testing. More expensive laboratory tests may be eliminated with the AsbestestTM which uses standard colorimetric pro cedures to detect asbestos-bound iron and/or mag ,, For information, call Technical Service toll free f 1-800-624-2232 '{in Florida, 1-800-282-7932). f E:C Apparatus Corporation, 3831 Tyrone Blvd. N., nesium. It is sensitive to as little as 1% asbestos with no false negatives for either serpentine or amphibole< St* Petersburg, FL 33709,813-344-1644. Telex 51-4. 7^36mHALA material. CeJ/Cc{ T'AeJA'S Af A 0001468 Circle 99 on Reader Service Card yfeL ioajA && C C SA/W* champlin c INTER-OFFICE CORRESPONDENCE TO: Pete Horseman FORT WORTH, TEXAS FROM: Joe F. Gay DATE: April 21, 1980 SUBJECT: Rollins Environmental Services, Inc. I have reviewed the contract proposed by Rollins and do not have any objection except that the term "to the best of its knowledge" should be inserted into the first sentence of Paragraph 13. The sentence would then read"13. OSHA. Company represents and warrants that to the best of its knowledge Waste does not contain the following substances in concentrations greater than those specified below:". I have discussed the addition of this part of the contract with Davis Scharff and he assured me that he has no objection to it being included. Obviously it will require some testing, but Davis feels that this testing would have been required anyway. I would request that you discuss with Brack Routh the requirement regarding asbestos. As you are aware. Brack is responsible for insuring that adequate precautions are taken by Champlin personnel when they handle, package and label asbestos material in the refinery. cc: C. J. Hoffman R. J. Light B. D. Routh D. Scharff ft 0061590 TEXAS ECOLOGISTS, INC. ws lOill -- lo.Q.Qj ----- U,2,6 ROBSTOWN, TEXAS REQUEST FOR DISPOSAL Please refer to the separate detailed instructions while completing this tom. Each item on the form must toe tilted in with the exception of the gra shaded areas, which are for TECO use only. If an item is not applicable, place "N/A" in the spaee provided for that Item. (If lab analysis was performer please attach* signed copy.) GENERAL INFORMATION US EPAGENERATOR ID NUMBER 1*1* l l l0|3|-ll,l ,S|-Ui9i S GENERATOR NAME GENERATING FACILITY ADDRESS | C ,H ,A , M, P ,L , I, N, , ? E, T, R, Q L E, 0 ,M, PQ , , , , I1 1,.,,,-1-Oi, I|X,|i,,^.,li_7iAlIII1. i -J_____IItI__L 118 1 o, lj t P, EtC |Z , S,1 T iBtL tV P i i i t i CITY lc ,0 JR. , P,U,S , , C,H,R tI , S|T ,1 1 STATE 1T iX I ziPCOOE 17 18 i4 > 6191~1 i f i COUNTY 1 N, U,E , Q E, S, , ,,|| | |__ J STATE EPA GENERATOR IDNUMBER ___ 30532 STATEws# ____ 17535.0. ADMINISTRATIVE CONTACT 1D A y i * ,S , 3 P ,H ,A , R, F,F , , , , , , , ,| . t,,,. i____ L TELEPHONE A/C 1 * ~1 P , jl ; Ext j-- 1,4 | GENERATOR TECHNICAL CONTACT IrJC ,H A E P . , C, A, MtP ,B JB L .L-, , , 1. TELEPHONE A/C ^ 5,121 ~ "* fa .1.9 l7 1 ll ' Ext I--L-4.l4.i4 1 WASTE HAULER It E iXiA lS i |E iC |0 L 0 C 1 Si Ti St I}. , | X .J--!--I--I--I--|. address P.0. Box 307 Robstown. Texas_____7.818Q WASTE STREAM NAME i A, S ,B jS S , T ,0 ,S , , , , , i i , , , i , i i i i i t i i j , > ...i i i i i i PROCESS GENERATING WASTE j A, S , R E, S, T ,0 ,S , .I,H,SP,L,A,I^, ,E ,Q \J , I ,P ,M F N T , , i , t ,_L & 0065002 RETURN COMPLETED FORM TO: P.O. BOX 7246 LOUISVILLE. KY 40207 Phone: 502-426-7180 CUSTOMER# DATE RECEIVED 1..1-J___ II u/lj/lj BCni.NAIIM, ' sampling information L J/L JDATE SAMPLE TAKEN j i PERSON SAMPLING -- TITLE ''> i ' 1` '___ - - - ' * :-- ^--r _ i i ; t t i iiii'ii___ L_J___ IiII1 . TELEPHONE A/C SAMPLETYPE: Q (1> GRAS <2> COMPOSITE OF MORE THAN ONE SAMPLE (31 24-HOUR COMPOSITE C W in-oepth sample Q (S) SPLIT SAMPLE (8) DUPLICATE SAMPLE (7) OTHER---------------------------------------------------- COMMENTS LABNAME EPA HAZARDOUS WASTE CODES 3 Check il waste is not hazardous par RCRA t* <4ocfr2bi.3o-2i.33> DATE OF ANALYSIS I__ r t i. 1 La__ Ii II___ 1--J___I I___ L_J___t_ I i I I i i i i 1 1II--I--I G Check if additional EPA hazardous waste numbersareattached III!_J 1--1--1--l--i ft . LJ-l I j___L .WA.STE DESCRIPTION WASTE COMPOSITION Cheek the one box that best describes the waste stream. (1) ORGANIC S (2) INORGANIC (3) 80TH ORGANIC & INORGANIC COLOR Check the one box that best describes the waste stream. (1) (2) (3) RED SLUE YELLOW (4) GREEN (5) SUCK (6) CLEAR APPEARANCE Check the one box and Indicate the number of layers (phases) that best describes the waste stream. (1) FREE PLOWING LIQUID (2) RESINOUS LIQUIO (3) OILY LIQUID a (6) POWDERY .0 (7) GRANULAR 63 (8) SOLID (4) VISCOUS LIQUID Number of layers (S) SLUOGE (?) SROWN 09 (8) MILKY WHITE (9) . PURPLE (10) ORANGE ODOR Check the one box that beat describes the watte stream. (1) SWEET (2) SOUR (3) PUNGENT (4) BACTERIALOQICAL (S) ETHER-UKE (6) ALCOHOL-LIKE .0 S3 (7) AROMATIC (0) SOLVENT-LIKE (9) NONE i I sTTLEABLE SOLIDS . F.equired for disposal ol liquids. PERCENT LIQUID VISCOSITY (Centipoiss) BOILING POINT DENSITY Numerical Value Mandatory (1) Ibs/pallon (LIQUIDS) (2) Iba/cu. ft. (SOLIDS) SAMPLE RANGE LOW HIGH J ml/1 1 ' lit! ~ J__l'>l ml/1 XJL-1 % J__ L. I 1tI* L, i,,.,J JLJL3 f" 1-.L.I. I J Loi II__ L..1. .1 1Ll... 1. *P L.iAA.t-1 .1.0t I I . 2, Of WASTE PROPERTIES IGNITABIUTY (40CFR2S1.21) FLASHPOINT SAMPLE. U 19 I 9| * RANGE LOW J__ L HIGH ANALYTICAL TECHNIQUE Doss Malarial ignite Whan Exposad To: AIR? (1) Yoa Q (2) No WATER? ID Yea (3(2) No It yes. explain FRICTION? (ilYea 63 (2) No fl 0065004 LjJ*" l-i ' l--i X X1 J___ L ''REACTIVITY U0CFR26t.23t CYANIDE AS CN " TOTAL % BY WEIGHT SULFIOE AS S~ TOTAL % BY WEIGHT SAMPLE 1 -fi ! 1 1 T ,.l..1 LOW 'RANGE HIGH 1 * J * l_... ; J1 < . l1 , , Ahin vriftAi Ter.wmouP Does the waste contain any ot the following? 1. A solid form of nitrate/nitrite Q (1)Yes D2. A precipitate of nitrate/nltrito (1) Yea 13 (2) No 13 (2) No Is waste reactive with water to cause splattering or gaa release? <1)Yea (3 (2) No If yes. describe reaction ............... CORROSIVITY (40 CFR 281.22) Compiate eithar pH (or inorganics, or the corrosion rate test fororganlea. For solids. use the 1% solution last described in the instructions. Alkalinity (for pH greater than 9) PH SAMPLE J__ I__ I__ L ______ RANGE LOW HIGH 1 ' T I - I I -t I. mg/I aa calcium carbonate J Acidity I tor pH less than 5) J__I__ I__ I__ L mg/I aa calcium caibonata CORROSION RATE TEST TOXICITY (40 CFR 261.24) LEACHATE -- mg/I SAMPLE 1 * 1 * mm/yr LOW RANGE HIGH [.lJL.J " I I T.I.J, LEACHATE mg/I LEACHATE mg/I LEAD J_J___I___I--2- CHROMIUM > ' 1 * ENORIN J--1___L MERCURY CYANIDE BARIUM . J__ I__ 1__ L 1 I .1 1 J__!___I__L . I ARSENIC SELENIUM SILVER CADMIUM J_J___ L '( f -L_i___ t t f I t I t_ UNOANE -L-' < * MSTHOXYCHLOR 'm TOXAPHENE I I* L. J----1__ L_J 2. 4-0 ; J--I----1___L 2.4.5-TP 8ILVEX L--!--I____L_L_J LJ-L-J-L J___L--1 COMPONENTS Soecific cnemicai names ol components are required. DO NOT use generic names. Account (or 100% of the components. !A iS 3 i Et S i Ti Oi Si J__ I--1--!___ !___ I___ till ' I I i___ I___ I___L PERCENT SAMPLE RANGE LOW HIGH -1.,i-i-JLucLflA JUi.0.,01-h. o ,! J___1___ L JL--J___ L jl!i--i. ,ii__ il_j t I i t_J Ii.1 __________ uj___i_j___ ___ f H t i I" L. j___iiiiiii:i _J_____________ ilii i i i i i iill___ L -i-if II. . . 1-1 : l-U______ I___ L-J___ I___L_J___ 1!1i * * l I * I l l I II__ J__ 1___ _______ II-----t-`- i. ?' II- i i I | i 'IIIlIIIIliII i i i ' ' *>* i i i ii.. ii.. i-i. -lII___ _____________________________________ IIIII1I,,. I 1 JLjuJLt l-L-.1 1.. I1----------L, CHECK IF ADDITIONAL COMPONENT DESCRIPTIONS ARE ATTACHED ( ANALYTICAL TECHNIQUE '__________ \ dies this waste stream contain biologic materials, pathogens, or etiologies! agents: !G (1) Yea B (2) No SHIPPING INFORMATION ANTICIPATED ANNUAL VOLUME . . 1--1--I--I--I--I L-1-3..Pi S3 (1) GALLONS (LIQUIDS) (2) CU.FT.(SOLIDS) ,Anticipated Transport Frequency 9* 1. DAILY z WEEKLY i 61-WEEKLY 4. MONTHLY 5. QUARTERLY 6. SOW*ANNUALLY IS T. ANNUALLY 8. ONETIME A 0065006