Document qXqQ3ZGxnVNaweNQrrXo7MoK

FILE NAME: Westinghouse Pennsylvania Archives (WHPA) DATE: 1970 DOC#: WHPA012 DOCUMENT DESCRIPTION: WH Beaver Plant Documents Westinghouse Beaver No asbestos specific info 1970 punch cards with Operation/Hazard/Control Measure matrix 1970 report of inspection. Recirculation of air an issue 1970 Operation/Hazard/Control Measure matrix C O M M O N W EA LTH O P P EN N S Y LV A N I, D ir f U T u f M o r m( * i t h . D iv is io n o r Oc c u p it io n m . H c * i.T h [PLANT INFORMATION RECORD Stock No 5I.J Yeatinghouee Altctrio Corp* / *Y >MA C9ct Liatributlon A Control puipaeci LlViaiona--- csyjsl3r774r5000. J5S5G_Tuscarawas lid Dorrtr, P. rwiomf Electrical Control Apparatoti IIIUm Kirsch, Supervisor o f PaTtiy A rimici* A W. C a llo y, M.D gfCTHTVEO ADOPESS L50 Dutch Rldga Rd Deaver Pa usra Neva Wallace, RT.| Ann SAFETY superviso WiUiaa Kirsch INDUSTRIAL HYGIENIST H INSURANCE CARRIER :lf-lnjured LCGAL OVANER Corp. (Westinghouse ELctric Corp., Pittcburgh, Pa) [RECOMMENDATIONS Secure approval frog tho Dcpartoont to roclrcul*to air within ho plant. (Ltr. soot I l/2a/?0) 2, \ Exhaust tht bracing operation to tho putoldo and discontinuo tht reclrculatl' ( l t r . sont i I / 29/ 7O) r^MAP.K5J_Tho coapany has exhaust vontilatod aost of the hrIng operations that work with braaea that contain cadmluta coapony has purchased a General T Radio noise sieter* plana oo tjglng a lot of noise goanurtaenta in the plant Radiation - Machine - Registration ; T Y P E O f Inopoetion I/27/7O N. Ray Brown A Toa *E R S 0**N fL *2 i K3 !; C* " ; ~ * I LIS T HAZAROS AND CONTROL MEASURES ON REV ERSE SIDE RCCOMM X SURVEY ;J i0 X__ < C O X N T R O OL L E D HAZARDS C f. > ? g X X H0A Z A R O5S / 1 gX ! H ; - 0 ? 8 g l XX ft Om 5 cn 5 5 i X A sm * X I{1 9 * Aa*abljr ?4 acting Grinding Intir typ nolj JfcUlDiaii* GJ^D. u m Melting Pot Clic) " Wir Vapora Punching - 20 Plating Aroq ' Flawing Line A H^O Kins Hitil Duitf, Wolee O.A.D.t lMPict trp# noii Eampneco Protect, clothing - i-' G.A.D. protect. clothing, p t Sodium Cyanldo Klrta hyg A Vapora, HOI Cae. Acid Upping HH0,, A H,,SO, Miete l.B.V. to the outeldo T_0 Lipping vmpeaf Protecti clothing Miota A Vapor* L.E.V. tu the uutalde olothing, per. hyg Dsnnntornatlonal) Xcolinucd on aecond choot) ;>! -c 'v.*->j.yte . , ' ' v V> . . ? ,V . # .'*.< ty, . fii, * ' . -' - 'v ,* .. "V*- Vtjft ir'.'' . > V ? DiriIon of Occupational Health , 505 Stata Office Building 300 Liberty Avenue Pittsburgh, Pennsylvania 15222 January 29, 1970 A t ^*.vVi V#**. 1 r - Veutinghouae Electric Corp_o_ra4t4i~o.n Distribution & Control Equipment Divifiions Tuacauawaa Road Beaver, Pennsylvania 15009 , '.;:* Attention: Mr. William Kirsch . Supervisor of Safety & Training - '.j/ *'; ' Gentlemen: .-M .' . ;V. ' -. y ''7* ',.V A `* 1 An inspection of your plant was conducted by Mr* N. Ray Brown, industrial hygienist, on January 27, 1970 to evaluate health hazards to which workers may bo e-xposed.4 , ,, . r Based on this inspection, the following recommendation is made* ; v / ;' v >: ' 'V ' Discontinue the recirculation of air at the Brazing Operation in the Cl Area and exhaust vontilate the operation to the outside. The above recommendation should be accomplished within 30 days following thereceipt ofthis letter. - - . , - - ' v Thank you for your cooperation. If you have any questions regarding thisinspection, pleaselet us know. t . . . '*.' ' ' __ Very truly yours, jL::,u:" ; ' Au La Fannick j Ab.,.0 ... Regional Industrial Hygienist ./Human; Services Region V NT/KRB/Jal j cc: Central Office (2)7/" ' File F.U. ! ' \ / /J I .* Division of Occupational Health 505 State Office Building 300 liberty Avenue Pittsburgh! Pennsylvania , 15222 `,v * . January 28, 1970 ' , 1/ r . - . Westinghouse Electric Corporation Distribution A Control Equipment Divisions Tuscauawas Road ' Beaver, Pennsylvania 15009 Attention: Mr William Kiroch ; Supervisor of Safwty A Training . Gentlemen: .*: * : ; Re: Recirculation of Air - Article i32, Section 6 ci*' : .. , On Janurty 27, 1970_^iMpectlon .d. j t W * * `CJJU ' ' Such systems must be exhausted to the outside or must be approved bv the Department in accordance with Section 6A, Article i.32 (enclose ) ta.Srt.STwllc.Uon. hich w.r. given to you during the Inopectlon in triplicate and return them within 15 days. If you have any questions regarding the completion of.th*8/,g ^ 1Sn2') or need Additional forms, please do not heeitate ^.contact me (565-5102). . 'h^^vis XU m Very truly ydurs, In Q j in v '! : -T ' Nicholas Fannick *> ' Regi5i)kl Industrial Hygienist Hunan' Soryc.s Region -V . NF/MRD/TWA/Jal Enclosure : / 0 ' . ?>'; ' f -I // . '*'*J>**-/ cc: Central Office (2)-Air Recirculation Committee 7$ /r*^w > ' File - /.tf&prix, 'j PA S- 350 Ncr r-ir J PAH'.v continued - Page 2 # Meetinghouse Eloctrlc Corp. Distribution 4 Control Equipment Divisions Tuscarawas Rd. Beaver, Pa. 15009 OPERATION Plating Lino #2 Dip Cleaning H20 Rinse Acid Dipping H20 Rinsing Zinc Immersion Dip H20 Rinsing - 2 Copper Plating - 2 H20 Rinsing Silver Cyanide Dip HAZARD CONTROL MEASURE >. v ` ^ ;2 / r . T . , / V '**. * ' NaOH Hist 4 Vapor, L.E.V. to the outside, per. hyg Derm. Dampness Protect, clothing HNO^ Mist 4 Vapor, N O' Gas, Derm. X X L.E.V. to the outside, per. hyg. Dampness vT Protect# clothing V > : 3 NaOH 4 ZnO Mists 4 Vapors, Derm. G.A.D., per. hyg. . Dampness *' * Protect, clothing ' '' CuCN 4 NaCN Mists 4 Vapors, HC2I Gas, Derm. C.A.D., per. hyg. ' Dampness Protect, clothing Silver Cyanide 4 L.E.V. to the outside, per. Potassium Cyanide hyg. Mists 4 Vapors, Hydrogen Cyanide Gas, Derm. Raprodurt! n cf r 0- ' PA STATE - PJeo?-'C: ; 350 North CJr^f, >: ' PAHistoric"!A f-'v* % continued - Pago 3 OPERATION H^O Rinse B Vostinghousa Electric Corp* Distribution A Control Equipment Divisions Tuscarawas Rd. Boayer, Pa. 15009 >.'-?j..' tit/"'VV*.Vi... i<a!*;V."3-v/,vr,V- . _j liSlM HAZARD CONTROL MEASURE Dampness Protect, clothing Hot H20 Rlnsa do. + Steam L.E.V. to the outside riatlnK Line #3 Dip Cleaning H,,0 Dipping Acid Dipping H20 Rinsing NaOH Mist A Vapor, do. + per. hyg. Derm. 1 *- . .A -\X .-i':'vj->V-0*^ .**v-' ***?' Dampness Protect, clothing ; .. ; ' - H-SO. Mist A Vapor, L.E.V. to the outside, per. Derm, hyg. a Dampness Protect, clothing Copper Dipping H20 Rinsing Copper Sulfate A Sodium Chloride MistB & Vapors, Derm. Dampness G.A.D., per. hyg. 7 ' Protect, clothing | Impact Zinc Plating Zinc Dust O.A.D., done in wet solution Rar 550 No.u.C,V- fi-r,, : ' " ! PA P i '*. continued - Page U OPERATIOil Shrinking Vinyl Cover (gas-fired oven) Weetinghouse Electric Corp* Distribution A Control Equipment Divisions Tuscarawas Ed* Beaver, Pa. 1J009 HAZARD - - ' ' CONTROL MEASURE Heat, CO A CO, Gases Closed oven with L.E.V. to the outside Silver Soldering (0, A Acetylene Torch) Silver, Copper, Zinc, Cadmium A Fluoride Fumes, CO, CO, A NO Gases, I.R.*Rad. LE*7. to the outside Blasting Metallizing Aluminum Oxide Dusts L.E.V. to dust collector A Metal Dusts4 .. Silvor Fumes, CO, CO,, 0, A N O Gases, Smoke, I.R. A U.V. Rad. .' . . L.E.V. to the outside, closed oper. Underwriter's Laboratory Electrical Testing Electrical Shock Groundod Auto. Plating Area Rinsing - 2 H^O Vapor Protect* clothing Nickel Plating Nickel Sulfate A Nickel Chloride Miste A Vapors, Dorm* G.A.D., per. hyg. Kepro&cr-.. 350 Nor! ; PAf continued - Pago 5 OPERATION Tin Plating Cadmium Plating Copper Plating Rinsing Acid Dipping Rinsing Dip Cleaning Phosphate Coating Westinghouse Electric Corp. Distribution A Control Equipment Divisions Tuscarawas Rd. B.av.r, P.. 15009 HAZARD CONTROL MEASURE Sodium Stannate A Sodium Hydroxide Mists A Vapors, Derm* L.E.V. to tha outside, par* Sodium Cyanide Mist Vapor, HCN Gas, Derm. 1 Copper Cyanide A Sodium Hydroxide Mists A Vapors, HCN Gas L*E*V* to the outside Dampness Protect# clothing Hydrofluoric Acid L.E.V. to the outside, per. Mist A Vapor, Derm. hyg. ;.... ' Dampness Protect, clothing NaOH Mist A Vapor, Derm. L.E.V. to the outside, per. Phosphate Mist A Vapor, Derm. do. + protect, clothing Reoroducl'i'i of an 35C North Sir*-: PA H.sten"