Document qK8agqGqXYR04VxrExe5oDo5
Employee/SS^
1. General Area fume escaping from extruder hood
2. W. Bell 407-68-2637
3. M. Goebel 306-36-7197
4. H.L. Arant 401-10-8663
APPENDIX
LOUISVILLE MONITORING RESULTS October 18-20, 1983
Location/Job ORGANOTIN1
B-line extruder
Sample Time (min.)
361
Concentration (ide/M^)
0.140
B-line Henschel mixer operator B-line mill {Farrell) operator
BUTADIENE2
Pump house tank farm operator
362 361
9
0.004 0.009
251 ppm (no respirator worn)
*TLV for organotin ,100 mg/M2 2
BFG exposure limit for butadiene
25 ppm
T.
cn BFG51270
November 17. 1986
Tom Bialke
PVC Processinq/Tin Chlorides
Attached is a report (excerpts) by R. F. Koebel demonstrating that ambient exposure of tin chlorides released as a result of
PVC processing are less than 0.03 mg/m3. This level is far below the 0.1 mg/ra3 ACGIH and OSHA exposure limits.
Jim Tanzilli
1759x/dl
attachments cc: A. J. Olson
G. A. Jones/T. F. Harcison/G. L. Rutman R. K. Schlatzer
BFG51271