iM. He Mo*- i'ciA j Richard Flaming E. M. Spurlock Retest at Pensacola Plant 26 April 1974 T. L. Carey Dr. Kotin, Mr. A. K. McMillan and myself met with Dr. Beldleman today to review the employees who had been retested after their first test revealed some abnormalities. 1 will review each case and outline the results. - This employee is the one employee who turned up with AOL and we removed him from the PVC Plant. His first liver profile showed some abnormalities and upon reteating, one of the tests showed abnormal. In view of the AOL function and the one abnormality. Dr. Beidltman recommended and Dr, Kotin concurred, that this employee should have a llvar scan. This man had one abnormal liver function test and upon retesting, his Alpha Fetal Protein test was abnormal and Dr. Beldleman recoomended with Dr. Kotin's concurrence, that this man undergo a liver scan. - This employee had two abnormal tests and upon retesting^tn^aonormalltiea were reduced but were still beyond normal limits. This employee will be retested in 90 days on those tests which w^ge abnormal. On the first teat, this employee had one abnormal'teat and upon retesting, the one abnormal teat was normal but two other teats were abnormal. The doctors sgreed to repeat both taBts in six months. - This employee had one abnormal test and upon retesting, the test was still abnormal and the doctors recommended a liver scan. ~~ ~ - ibis employee had one abnormal teat and upon . retesting, the test was normal. However, the doctors recommended that this employee be advised to see his personal physician due to other causes. AP00035097 Richard Fleming 2- 26 April 1974 - Two abnormal tests on first testing and second testing^ Due to the variables in these two tests, the doctors recom mended that he be retested in three months. - This employee had one abnormal test and upon retesting, he had four abnormal tests. The doctors recommended a liver scan. Ona abnormal test on first testing and a slightly lower percentage on the second test and the doctors recommended that he be rechecked in six months. recommendations. - One abnormal test and none on retesting. No This employee had more than one abnormal test and upon retesting, the tests were slightly above normal. Suggest retesting in three months. Both doctors recommended that exposure to Vinyl Chloride Monomer. be removed from any They also recommended that be removed from any ex- posure to PVC due to the possibility of AOL. Dr. Kotin toured the plant and recosnended that we use dust respirators in the PVC loading area immediately. Dr. Beidleman called the plant and the arrangements are presently being made for the above employees. Dr. Kotin informed me that he did not feel it necessary for him to return to the Pensacola plant because he felt Dr. Beidleman was doing as excellent job and any questions could be resolved by telephone ..*77 EMS: jsr^bcc: t-dC K. McMillan J. F. Odom M. Spurlock AP00035098