Document q8gNEx7wRGvoOObLyoZLGgx5
GRACE
'*. R G-;:e & C:
62 'A'*'*'* ----g Av
C:"C','aci A'1;::
'6:7. 876-'
January 2E,
Don f'cCrae E. I. Dumont & Co. P. 0. 5ox 1378 Louisville, Kentucky
40202
.- '
Dear Mr. McCrae:
Attached is a copy of our Material Safety Data Sheet on Industrial Vermiculite #1 size. As stated in the M.S.D.S., in
dustrial end-users of this material should determine for themselves, whetner they are in compliance with OSHA Regulation 1910.1001 with regard to in-plant exposure to airborne asbestos fibers. It has generally been our experience that where appropriate industrial
hygiene practices are followed, exposures are well within the OSHA limits.
Should you elect to make such an in-plant survey, we would be interested in knowing what your results were. This kind of end-
use input permits us to assemble a picture of end-use exposures with tne product as we are presently controlling.
Very truly yours,
RCE:M
Attachment
Quality Assurance Manager Construction Products Division
51 /01a
II53721 DU 062023
I n.YTB: *'une
19-7
L'.S. CE- ' ~ E C? LAECT-. Occupations! SsIsT/ cr.ri health Admin,strruicn
!\MATERIAL SAFETY DATA SHEET
Required under USDL Se'e'y ana Hea.th Regulations for Snip Repair,nt Shipbuilding, and Sniporeakir.g (23 CFR 1915, 1916, 1317)
MANUFACTURER'S NAME
SECTION 1
EME*CENCV T.E-^CNt sw.
W. R. Grace S Comoar.v ACC R ESS ,\\urther. Street, Ciry. State, cr.2 ZIP C>-V.
617-S 76-14 29 M4"7
67 Whittemar* AvpnuP-rar>.ririgPr M*____ G?1 40
CHEMiCAw name ano synonyms
I TRADE NAI^E ANO SVNONVMS
Excar.ded Libbv, Montana Vermiculite
industrial Vemiculite-Size p 1 , ,3,
ChESOCAW FAMILY
_ FORSiuLA
Magnesium Aluminosilicate Mineral
(Me,Ca,K)-(Al,Fe,Mc)-(Si,All (0) (OH' H
SECTION II - HAZARDOUS INGREDIENTS
Contains less than 0.1% by weight_f-a naturally occurring cor.tarJ.nant tremolite. OSHA Regulation 1910.1001 defines tremolite as asbestos. Some forms of tremolite are platy. other forms can be fibrillated by physical handling to release airborne "asbestos fibers". Regulation 1910.1001 places a limit of 2 "asbestos fibers"/cc; 8 hour time weighted average and a maxi mum of 10 "asbestos fibers"/cc at any one time for airborne fiber exposure.
The physical handling given to expanded Vermiculite can release both air borne fibers and nuisance dust. Refer to OSHA Regulation 1910.1001 for ap proved control procedures.
SECTION III - PHYSICAL DATA
BOILING POINT (F.) VAPOR PRESSURE (mm H.)
NA
j
VAPOR DENSITY (AIR-1)
NA
solubility in water
| slight,
______________________________________________________________________if
SPECIFIC GRAVITY
PERCENT. VOLATILE BY VOLUME (%) EVAPORATION RATE
( -1)
Bulk Density lbs/c.f.
flowingappearance AND ODOR pree
dark brown to tan colored Darticles.
NA NA NA
_________________
SECTION IV - FIRE AND EXPLOSION HAZARD DATA NOT APPLICABLE
usad)FLASH POINT (Matnod
FLAMMABLE limits
Ltl Ue'
EXTINGUISHING MEOIA
SPECIAL FIRE FIGHTING PROCEDURES
UNUSUAL FIRE ANO EXPLOSION HAZARDS
DUP 11537
PAGE (1)
(Continued on reverse side)
Form OSHA-20
tn. Mir 72
The information contained herein is based on knowledge believed to be reliable
but W.R. GRACE 6 CO. MAXES NO WARRANTIES, EXPRESS OR IMPLIED, AS TO THE ACCURACY OR
ADEQUACY THEREOF. Nothing herein excuses the recipient hereof from such duties
as shall be imposed by the Occupational Safety and Health Act of 1970 and regula
tions issued pursuant thereto.
DU 062024
SEC7!C.\". HEALTH HAZARD DATA
-Dust respirable fractisr. 5 r--
Total dust IS rr--/;.-.-1.
Airbcrr.e asbestos fiber 2f/cc 7 .K.A.-Ceiiir.c iCf/cc at or.e time.
EViSG'NCv and FiR$T a d 9OCDuSj
ST A 3' L TV
UNSTABLE
SECTION VI - REACTIVITY DATA
CONDITIONS TO AVOID
STABLE incompata3<liTY (Matensu to avoid/
HAZARDOUS DECOMPOSITION PROOUCTS
hazaqdous
MAY OCCUR WILL NOT OCCUR
.-
CONDITIONS TO AVOID
applicable
SECTION VII - SPILL OR LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR Sl_LEO
Dampen slightly or use other techniques which control airborne fibers and dust within the limits of Section V above.
WASTE DISPOSAL METHOO
Use disposal tpohnigpied which control airborne fibers and dust within the TLV limits of Section V above. See OSHA Standard 1910.1001. Paragraph (h) ( 2 ) Waste Disposal.
c SECTION VIII SPECIAL PROTECTION INFORMATION
See OSHA 1910.1001-Controls such as isolation, enclosure, exhaust ventilation and dust collection shall be used if necessary to meet exposure limits. Also see OSHA Standard 1910.1001 Personal Protective Equipment for dealing with work environments in excess of exposure limits.
SECTION IX - SPECIAL PRECAUTIONS
PRECAUTIONS TO BE TAKEN IN HANDLING AMO STORING
other precautions
PAGE (2)
C 0 X .543
PUP 1 153723
Form OSHA-20
R#. Miy 72
DU 062025