Document q8gNEx7wRGvoOObLyoZLGgx5

GRACE '*. R G-;:e & C: 62 'A'*'*'* ----g Av C:"C','aci A'1;:: '6:7. 876-' January 2E, Don f'cCrae E. I. Dumont & Co. P. 0. 5ox 1378 Louisville, Kentucky 40202 .- ' Dear Mr. McCrae: Attached is a copy of our Material Safety Data Sheet on Industrial Vermiculite #1 size. As stated in the M.S.D.S., in dustrial end-users of this material should determine for themselves, whetner they are in compliance with OSHA Regulation 1910.1001 with regard to in-plant exposure to airborne asbestos fibers. It has generally been our experience that where appropriate industrial hygiene practices are followed, exposures are well within the OSHA limits. Should you elect to make such an in-plant survey, we would be interested in knowing what your results were. This kind of end- use input permits us to assemble a picture of end-use exposures with tne product as we are presently controlling. Very truly yours, RCE:M Attachment Quality Assurance Manager Construction Products Division 51 /01a II53721 DU 062023 I n.YTB: *'une 19-7 L'.S. CE- ' ~ E C? LAECT-. Occupations! SsIsT/ cr.ri health Admin,strruicn !\MATERIAL SAFETY DATA SHEET Required under USDL Se'e'y ana Hea.th Regulations for Snip Repair,nt Shipbuilding, and Sniporeakir.g (23 CFR 1915, 1916, 1317) MANUFACTURER'S NAME SECTION 1 EME*CENCV T.E-^CNt sw. W. R. Grace S Comoar.v ACC R ESS ,\\urther. Street, Ciry. State, cr.2 ZIP C>-V. 617-S 76-14 29 M4"7 67 Whittemar* AvpnuP-rar>.ririgPr M*____ G?1 40 CHEMiCAw name ano synonyms I TRADE NAI^E ANO SVNONVMS Excar.ded Libbv, Montana Vermiculite industrial Vemiculite-Size p 1 , ,3, ChESOCAW FAMILY _ FORSiuLA Magnesium Aluminosilicate Mineral (Me,Ca,K)-(Al,Fe,Mc)-(Si,All (0) (OH' H SECTION II - HAZARDOUS INGREDIENTS Contains less than 0.1% by weight_f-a naturally occurring cor.tarJ.nant tremolite. OSHA Regulation 1910.1001 defines tremolite as asbestos. Some forms of tremolite are platy. other forms can be fibrillated by physical handling to release airborne "asbestos fibers". Regulation 1910.1001 places a limit of 2 "asbestos fibers"/cc; 8 hour time weighted average and a maxi mum of 10 "asbestos fibers"/cc at any one time for airborne fiber exposure. The physical handling given to expanded Vermiculite can release both air borne fibers and nuisance dust. Refer to OSHA Regulation 1910.1001 for ap proved control procedures. SECTION III - PHYSICAL DATA BOILING POINT (F.) VAPOR PRESSURE (mm H.) NA j VAPOR DENSITY (AIR-1) NA solubility in water | slight, ______________________________________________________________________if SPECIFIC GRAVITY PERCENT. VOLATILE BY VOLUME (%) EVAPORATION RATE ( -1) Bulk Density lbs/c.f. flowingappearance AND ODOR pree dark brown to tan colored Darticles. NA NA NA _________________ SECTION IV - FIRE AND EXPLOSION HAZARD DATA NOT APPLICABLE usad)FLASH POINT (Matnod FLAMMABLE limits Ltl Ue' EXTINGUISHING MEOIA SPECIAL FIRE FIGHTING PROCEDURES UNUSUAL FIRE ANO EXPLOSION HAZARDS DUP 11537 PAGE (1) (Continued on reverse side) Form OSHA-20 tn. Mir 72 The information contained herein is based on knowledge believed to be reliable but W.R. GRACE 6 CO. MAXES NO WARRANTIES, EXPRESS OR IMPLIED, AS TO THE ACCURACY OR ADEQUACY THEREOF. Nothing herein excuses the recipient hereof from such duties as shall be imposed by the Occupational Safety and Health Act of 1970 and regula tions issued pursuant thereto. DU 062024 SEC7!C.\". HEALTH HAZARD DATA -Dust respirable fractisr. 5 r-- Total dust IS rr--/;.-.-1. Airbcrr.e asbestos fiber 2f/cc 7 .K.A.-Ceiiir.c iCf/cc at or.e time. EViSG'NCv and FiR$T a d 9OCDuSj ST A 3' L TV UNSTABLE SECTION VI - REACTIVITY DATA CONDITIONS TO AVOID STABLE incompata3<liTY (Matensu to avoid/ HAZARDOUS DECOMPOSITION PROOUCTS hazaqdous MAY OCCUR WILL NOT OCCUR .- CONDITIONS TO AVOID applicable SECTION VII - SPILL OR LEAK PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR Sl_LEO Dampen slightly or use other techniques which control airborne fibers and dust within the limits of Section V above. WASTE DISPOSAL METHOO Use disposal tpohnigpied which control airborne fibers and dust within the TLV limits of Section V above. See OSHA Standard 1910.1001. Paragraph (h) ( 2 ) Waste Disposal. c SECTION VIII SPECIAL PROTECTION INFORMATION See OSHA 1910.1001-Controls such as isolation, enclosure, exhaust ventilation and dust collection shall be used if necessary to meet exposure limits. Also see OSHA Standard 1910.1001 Personal Protective Equipment for dealing with work environments in excess of exposure limits. SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AMO STORING other precautions PAGE (2) C 0 X .543 PUP 1 153723 Form OSHA-20 R#. Miy 72 DU 062025