Document q8OZdJd9xOnRr43eexMxNGQn

Heating Systems (Hot Water) H. A. Thrush & Company Peru, Indiana Service and Sales Offices in Principal Cities THRUSH FLOW CONTROL SYSTEM Thrush Flow Control System of Warm Water Heating is more com pletely automatic than . was ever before offered for residential heating. The illustration shows the ten Thrush devices which make up this system. 1. Thrush Flow Control Valve. 2. Thrush Water Circulator. 3. No. 4 Thrush Differential Pres sure Relief Valve. 4. No. 12 Thrush Pressure Re ducing Valve. 5. Air-tight Thrush Pressure Tank. 6. No. 201 Thrush Radiant Heat Control. 7. No. 198 Thrush Relay Trans former. 8. No. 203 Thrush Modulating Boiler Water Temperature Con trol. 9. Special Combination Thrush Gauge and Thermometer. 10. No. 75 Thrush High Pressure Relief Valve. Thrush Flow Control System assures a continuous flow of radiant heat, reduces fuel consumption and provides domestic hot water for bath, kitchen and laundry the year around as a by-product. On new work it permits^the use of small pipe and valves which completely offsets the cost of the Thrush equip ment. Thrush Water Circulator Class FC Flow Control System--Flow Control Valve and Circulator Only Description Up to Up to Up to Up to Up to Up to Up to 300 q ft 500 sq ft 800 sq ft 1000 sq ft 1500 sq ft 2500 sq ft 5000 sq ft No. Valve...................... 114 1* culator.................... M 1* W WNo. I14A No. No. No. No. 115 IVi' 115 IVi' 120 2* 125 No. 130 3* y14 1' I4A I*// 15 IVi' 15 1 '/,* 22 2' 23 Class FCC Flow Control System-- Complete Circulation, Temperature and Pressure Control W yNo. No. No. No. No. No. Valve...................... 114 1* 1I4A I*// 115 IVi' 115 1*4* 120 2* 125 No'. 130 culator.................... 14 1* 14 y1* I4A l*/4* 15 IVi' 15 IVi' 22 2' 23 Relief Valve......... 4 Vi" 4 Vi" 4 Vi" 4 Vi" 4 Vi" 4 Vi" 4 Va* Valve...................... i2 y/ 12 Thrush Pres. Tank. 0 0 Vi" 12 1 Vi' 12 1 Vi" 212 Vi" 12 3 Vi" 12 '/,' 2-No. 3 Heat Control.... 201 i hrusb Modulating Hodcr Water 1 ero* perature Control. 203 1 hrush Kelay 1 runsformer.................... 198 201 203 198 201 201 201 201 201 203 203 203 203 203 198 198 198 198 >98 1010 Heating Systems (Hot Water) No. 114 II4A 115 120 125 130 H. A. Thrush & Company Peru, Indiana Service and Sales Offices in Principal Cities Sizes and Capacities Thrush Flow Control Valves Size 1* w IVi' 2" 2Vi' y Connection Screwed Flanged Hanged Hanged Hanged Hanged Radiation Capacity 300 sq ft 500 sq ft 1000 sq ft 1500 sq ft 2500 sq ft 5000 sq ft | Shipping Weight 1 3 lb 1 16b : 171b 191b 26 lb 39 lb Sizes and Capacities Thrush Water Circulators No. 14 I4A 15 22 23 Size 1* Screwed 1*4* Hanged Wl" Hanged 1~ h ianged y b Ianged Motor 1/10 hp 1/10 hp 1/8 hp 1/6 hp 1/4 hp Gallons Delivery 25 per min 35 per min 50 per min 75 per min 140 per min `Radiation Capacity 500 sq ft 800 sq ft 1500 sq ft 2500 sq ft 5000 sq ft Storage Tank Capacity 750 gal 1000 al 1500 gal 2000 gal 3000 gal End to End Dimensions $3// 91/,' IO*/8* iO'4' II'/j' . "Use next size larger Circulator for conversion jobs. Capacities of Circulators equipped with standard 110 volts. 60 cycles, single phase, a-c motors. No. 4^ No. 4 Thrush Differen tial Pressure Relief Valve provides absolutely safe re lief of excessive pressures. No. 201 Thrush Radi ant Heat Control auto matically controls circula tion of water so that warmth of radiators is constantly maintained. No. 12 Thrush Pressure Reducing Valve automati cally fills system and main tains proper amount - of water at all times. No. tos Thrush Modulating Boiler Water Tempera ture Control automati cally raises or lowers water temperature to meet the demands placed on the heating system by changes of outdoor temperature. 1011 No. 198 Thrush Relay Trans former for use with low Voltage No. 201 Thrush Radiant Heat Control. S'.