Document q8OZdJd9xOnRr43eexMxNGQn
Heating Systems (Hot Water)
H. A. Thrush & Company
Peru, Indiana
Service and Sales Offices in Principal Cities
THRUSH FLOW CONTROL SYSTEM
Thrush Flow Control System of Warm Water Heating is more com pletely automatic than . was ever before offered for residential heating. The illustration shows the ten Thrush devices which make up this system.
1. Thrush Flow Control Valve. 2. Thrush Water Circulator. 3. No. 4 Thrush Differential Pres
sure Relief Valve. 4. No. 12 Thrush Pressure Re
ducing Valve. 5. Air-tight Thrush Pressure Tank. 6. No. 201 Thrush Radiant Heat
Control. 7. No. 198 Thrush Relay Trans
former. 8. No. 203 Thrush Modulating
Boiler Water Temperature Con trol. 9. Special Combination Thrush Gauge and Thermometer. 10. No. 75 Thrush High Pressure Relief Valve.
Thrush Flow Control System assures a continuous flow of radiant heat, reduces fuel consumption and provides domestic hot water for bath, kitchen and laundry the year around as a by-product. On new work it permits^the use of small pipe and valves which completely offsets the cost of the Thrush equip ment.
Thrush Water Circulator
Class FC Flow Control System--Flow Control Valve and Circulator Only
Description
Up to
Up to
Up to Up to Up to Up to Up to
300 q ft 500 sq ft 800 sq ft 1000 sq ft 1500 sq ft 2500 sq ft 5000 sq ft
No. Valve...................... 114 1*
culator.................... M 1*
W WNo.
I14A
No. No. No. No. 115 IVi' 115 IVi' 120 2* 125
No. 130 3*
y14 1' I4A I*// 15 IVi' 15 1 '/,* 22 2' 23
Class FCC Flow Control System-- Complete Circulation, Temperature and Pressure Control
W yNo. No.
No. No. No. No.
Valve...................... 114 1* 1I4A I*// 115 IVi' 115 1*4* 120 2* 125
No'. 130
culator.................... 14 1* 14
y1* I4A l*/4* 15 IVi' 15 IVi' 22 2' 23
Relief Valve......... 4 Vi" 4
Vi" 4 Vi" 4 Vi" 4 Vi" 4 Vi" 4 Va*
Valve...................... i2 y/ 12
Thrush Pres. Tank. 0
0
Vi" 12
1
Vi' 12
1
Vi" 212
Vi" 12 3
Vi" 12 '/,'
2-No. 3
Heat Control.... 201 i hrusb Modulating
Hodcr Water 1 ero* perature Control. 203 1 hrush Kelay 1 runsformer.................... 198
201
203 198
201 201 201 201 201
203 203 203 203 203 198 198 198 198 >98
1010
Heating Systems (Hot Water)
No.
114 II4A 115 120 125 130
H. A. Thrush & Company
Peru, Indiana
Service and Sales Offices in Principal Cities
Sizes and Capacities Thrush Flow Control Valves
Size
1*
w
IVi'
2"
2Vi'
y
Connection
Screwed Flanged Hanged Hanged Hanged Hanged
Radiation Capacity
300 sq ft 500 sq ft 1000 sq ft 1500 sq ft 2500 sq ft 5000 sq ft
| Shipping Weight
1 3 lb 1 16b : 171b
191b 26 lb 39 lb
Sizes and Capacities Thrush Water Circulators
No.
14 I4A 15 22 23
Size
1* Screwed 1*4* Hanged
Wl" Hanged 1~ h ianged y b Ianged
Motor
1/10 hp 1/10 hp 1/8 hp 1/6 hp 1/4 hp
Gallons Delivery
25 per min 35 per min 50 per min 75 per min 140 per min
`Radiation Capacity
500 sq ft 800 sq ft 1500 sq ft 2500 sq ft 5000 sq ft
Storage Tank Capacity
750 gal 1000 al 1500 gal 2000 gal 3000 gal
End to End Dimensions
$3// 91/,'
IO*/8* iO'4' II'/j'
.
"Use next size larger Circulator for conversion jobs. Capacities of Circulators equipped with standard 110 volts. 60 cycles, single phase, a-c motors.
No. 4^
No. 4 Thrush Differen tial Pressure Relief Valve provides absolutely safe re lief of excessive pressures.
No. 201 Thrush Radi
ant Heat Control auto matically controls circula tion of water so that warmth of radiators is constantly maintained.
No. 12 Thrush Pressure Reducing Valve automati cally fills system and main
tains proper amount - of water at all times.
No. tos
Thrush Modulating Boiler Water Tempera ture Control automati cally raises or lowers water temperature to meet the demands placed on the heating system by changes of outdoor temperature.
1011
No. 198
Thrush Relay Trans former for use with low Voltage No. 201 Thrush Radiant Heat Control.
S'.