Document q3eNnMEE0dbyrD0z0v2EMy2VR
TABLE VI
WORKPLACE PROTECTION FACTORS FROM TRANSMISSION ELECTRON MICROSCOPIC ANALYSES
Workplace Protection Factor
Respirator
Fibers Exceeding 0.2 ura Diameter and 5 um Length*
All Diameter Fibers Exceeding 5 urn Length
3M 8710
330
120
3M 9910
47
41
Survivair 2000 with Dust. Mist and Fume Filter
28
29
Survivair 2000 with High Efficiency Filter
21
19
/
* Those which would be counted by the standard phase contrast microscopy method.
DUP 0907371