Materials Analytical Services 3597 Parkway Lane, Suite 250 Norcross, Georgia 30092 (404) 448-3200 Inc. TEM ASBESTOS ANALYSIS REPORT Client Sample ID: MAS Log Number: Sample Received: Sample Due Date: Type Analysis: Microscopist: ,, Reviewed By: Client Proj/ref: LAW/KENNESAW 1 M4287-1 2-15-90 3-06-90 !US^ ** Sample Area Filter Type: Filter Area: Grid Openings: Grids Examined: Avg Area of Grid: Tot Area Examined Magnification: Dilution Factor: 0.094 sq ft 47MM 1.34E+009 10 2 6707 67070 25000X 1:1000 Area Examined Structures <: 5 um >= 5 um < 5 um >= 5 um No. No. No. NO. Free Chrysotile Fibers: of Chrysotile Bundles: of Chrysotile Clusters: of Chrysotile Matrices: 17 5 0 10 2 3.623E+09 4.262E+08 0 1.066E+09 0.000E+00 0 0.00OE+00 0.000E+00 4 2.131E+09 8.524E+08 No. No. No. No. Free Amphibole Fibers: of Amphibole Bundles: of Amphibole Clusters: of Amphibole Matrices: 0 0 0 0 0 0.000E+00 0.000E+00 0 0.OOOE+OO 0.000E+00 0 0.000E+00 0.000E+00 0 0.000E+00 0.000E+00 Total Asbestos Structures/1 sq ft (All) : Total Asbestos Structures/l sq ft (>= 5 um) : 8.098E+09 1.279E+09 Comments: **CLIENT REFERENCE: 1190-2031-00 * The Detection Limit is calculated on the probability of analyzing one asbestos fiber or structure in the total area examined. * 0.000 display = Below Detection Limit