Document pqGda1wER4e6nv4B8YYdJ0yd

boot Diek Davis - Org. Salas September 3, 1963 Mr. Frank Hars4os Reliance Eleotrle * Engineering Company 1088 Ivanhoe Road Cleveland, Ohio 44110 Dear Nr. Hsradosi Confirming our talaphooa oonvarsations this weak, I an analosing additional information eonoaming tha safa usage of tha Aroelors. Enelosura 1 is a copy of a report by Underwriters' Laboratories showing tha results of their fire resistance tests and sane analysis of tha decomposition products whan Aroelors are subjected to high temperature or an electric arc. You will note that the study was done in relation to heat transfer fluids and that the samples were Identified as Thermofluids PR-1, PR-2 and PR-3. These are now our trademark heat transfer aaterials identified as "Thermlnola PR-1, PR-2 and PR-3. These compounds are heat transfer grade Aroelors 1242, 1248 and 1254 respectively. The second enclosure is a two page extraet of data from a report from the Kettering Laboratory at the University of Cincinnati. Although it deals with Aroclor 1248, we would expect that the results could be extrapolated to Aroclor 1242 since the chronic inhalation work on Aroclor 1242 was dene at the seme laboratory and shews comparable effects when animals were exposed to vapors at ambient temperatures. 1 sent you reprints of the work from Kettering on Aroelors 1242 and 1254 with my letter of August 27. Perhaps X should emphasise again that these reports deal with a specific use for the Aroelors in essentially "closed" systems where there is little or no opportunity for vapors which may be liberated at elavated temperatures to escape into the working environment. The conclusions regarding reducing ex posures to a wlnJmnm would apply, however, whether the Aroelors are used as dielcotrlee, floor tile plasticisers, die easting machines hydraulic fluids or in any other application* DSW 020248 STLCOPCB4008177 Nr. Prank Hastedoa Page 2 9/V65 We have attempted to point out in our literature and on tho labels for our Aroelora that the inhalation of vapors for Ions porioda should ha avoided and that the hasard la greater when the fluids are heated. Secondly, we have recwended that repeated and prolonged akin oantaot be avoided. The third enclosure (Hygienic Ouide - Chlorodiphenyla) was prepared by a number of industrial and governmental Industrial hygienists and represents the view of most of the professionals in the field in so far as tonicity characteristics and safe practices and usage are concerned. I told you on the telephone that other possible applications for Aroelora in machinery to be used in underground mines have been considered by mine fire and safety groups, other aompanies and Monsanto. The feeling of our Medical Department is that data are not yet available on actual experimental use of the Aroelora in mines to demonstrate absenee of toxic atmospheric concentrations We appreciate that mining ie a hasardous operation and that other toxic gaaee and vapors may be present in particular mines. We also recognise the need for lees flasnable materials and chemicals in mining equipment. At the same time we do not want to substitute occupational health hasards for fire and explosion haxards. 1 hope that it will be possible for you to eliminate the possibilities of release of Aroclor vapors in your application by design and engineering changes. Certainly in the past this has been possible with many new applloatlons for these materials. If I can be of any additional asslstanoe, do not hssltate to let me know. Very truly yours. EPWtmJb Enclosures co* Mack Nichols - Cleveland Elmer P. Wheeler Manager, ftiviroomental Health Medical Department osw 020249 STLCOPCB4008178