Document ppzk0gQQoOBKRkR6ONqbzYDBE

Hoffman Specialty Co., Inc. JfcwUiesJUating HOFFMAN DIFFERENTIAL LOOP The Differential Loop is the safety device for maintaining a water line in vapor and vapor vacuum systems. It is entirely autc)Stea^y non-adjustable and has no moving parts to stick at a critical m mat'cIn operation the water rises in the return main only to a certamen*` determined hneoiirgrhntt. *"Tl'Uhoe 1Alorotrpi ttkhaenn TfiuinnActti'inornt^s, blo_w!ing* over " quantity of steam which closes the No. 15 Valve used for venti Stn?" system and then compresses the air which is "bottled up" in the^r 6 main and builds up a pressure which prevents further rise of waterfo S?1 vertical part of the return beyond the predetermined amount. As as this is accomplished, and the action is almost instantaneous, the1n reseals and no more steam is blown over until the differential p'ressu0P slightly reduced. It will be readily seen that, by the alternate blot? 'S over and resealing of the loop, a constant differential pressure will'hf maintained between the steam main and return main. Also by the ma' tenance of this differential no matter how high the boiler pressure ir" circulation will start in a radiator as soon as the inlet valve is ODenS even though the return main vent is closed through loop action. P TM Standard Differential Loops are made in four sizes, to handle system up to 15,000 sq. ft. of radiation. For larger systems the No. 04 Loons can be installed in a battery. No. 01 and No. 02 Loops should not be used where the low point in the dry return is less than 24 in. above boiler water line; with the No. 03 and No. 04 Loops this distance must be at least 30 in. HOFFMAN DAMPER REGULATOR ` One of the most important features Vf the Hoffman Damper Regulator is the accurate pres sure control and resultant fuel economy. It is extremely sensitive in its action and con trols so efficiently that when inlet valves are Hoffman Damper Regulator turned on or off, the fire is accelerated or retarded to meet the change in demand for vapor. A low constant pressure is always maintained so that vapor enters the radiator as soon as a valve is turned on. The compensating or balancing plate is like a pair of scales. It is practically friction less, remarkably sensitive and operates on slight changes in pressure. It has an additional feature for the convenience of the installing fitter, in that the fulcrum on which the lever is suspended may be turned at different angles, permitting a straight chain connection with the dampers instead of at an angle, which might cause the dampers to bind. Fig. 1 shows Damper Regulator under no pressure. Compensating disc is in its uppermost position, the bottom of the disc being in line with bottom of inlet. The space above diaphragm is filled with water up to the inlet. Weights on lever are to be so placed that they will hold the diaphragm against the perforated plate. Drafts are held open until the predeter mined pressure is generated,'when through diaphragm action which in turn is trans mitted to the lever, drafts are closed. Fig. 2 shows position of Damper Regulator when drafts are closed. Vapor pressure has overcome upward force exerted by the weights on lever arm and forced diaphragm downward. The water on the diaphragm lowers with it and like wise the compensating disc until top of the disc is level with the bottom of the inlet, thus preventing any addition to the water above the diaphragm. With a slight drop in vapor the. weights force the diaphragm upward and drafts are opened. Write for Descriptive Circula --Hoffman "Controlled Heat" 822 : Co., Inc. Specialties, Heating Huffman KompoGw* HOFFMAN KOMPO-GAGE Measures pressure up to 30 lb., vacuum to 30 in. Pressure is registered in ounces up to 5 lb. Vacuum is shown in half inches up to 10 in. Used in Hoffman `"Controlled Heat" installations or in onepipe gravity vacuum systems equipped with No. 2 valves; in dicates efficiency of the apparatus when a warm house is main tained with vapor at temperatures considerably below 212 deg. ----- - The No. 12 Hoffman Blast Trap is adapted for draining condensation from Indirect Radiators, Dryers, Drums, Blast Coils, Unit Heaters, Hot Water Generators and Ends of Long Steam Mains or Risers. The Trap embodies the desirable feature of open bucket or float traps because it relieves condensation immediately upon its arrival at the trap regardless of the water temperature. Coupled with the float is a thermostatic member which positively overcomes-the chief difficulty with float traps by automatically relieving air as well as condensation from the system. Table of Nominal Capacities, No. 12 Hoffman Blast Trap No. It Hoffman Blast Trap Pressure. Pounds per Square Inch.. Vt Capacity, Pounds per Hour................ 800 Capacity. Square Feet Radiation.. 3200 1 1000 4000 2 1500 6000 34 1800. 2000 7200 8000 5 2500 10000 Maximum Operating Pressure, 30 lb. Capacities for over 5 lb. pressure, furnished on application. With Strainer: inlet connection, 1 in.; outlet, 1 in. *On the basis of lb. of condensation per square foot per hour. No. 19 Quick Opening-Hoffman Radiator Valve is of the semi-packless type for i . vacuum pump installations or for vapor systems where modulation is not required. Made in in. size only, capacity up to 200 sq. ft. C. I. Radiation. Regularly furnished in Lever Handle pattern. Wood Wheels or Lock Shields furnished on special order without extra charge. Extension stems supplied at an extra jg Hoffman Radiator Trap charge. No. 19 Hoffman Radiator Vat* No. lg Hoffman Return Line Valve or Radiator Trap is similar in principle to the No. 8 Valve. It is intended for pressures up to 15 lb. and radiators up to 100 sq. ft. Thermostats are interchange able and made of special Hoffman Diaphragm Metal that will not soften, stretch or crack under repeated action. Made with 'y't in. connections in Angle, Straightway, Rightand Left-hand Offset Patterns. For roughing measurements see page (821). Write for Descriptive Circulars 823