Document ppoayKL5jBwaxQqqYV7yYGGND

692 CHAPTER 26 1957 Guide' Table 22. Application of Pipe, Tube and Fittings for Heating and Air Conditioning Application Matebiau Commonly Used Chilled Water Cooling Tower Type K or L"hard copper or black steel, Schedule 40 Type K or L hard copper, wrought iron or black steel, Schedule 40 Underground Water 2-in. and smaller 2J-in. and larger Type K, soft copper or galvanized steel, Schedule 40 (for corrosive soils, a coated steel pipe should be used) Type K, soft copper, cast iron, Class 150 or galvanized steel, Schedule 40 (for corrosive soils, a coated steel pipe should be used) City Water--Inside Building Type K or L, hard copper or galvanized steel, Schedule 40 Underground Rain Water Conductors Small Installations Vitrified clay or cast iron soil Under paved areas Cast iron soil Large Installations 8-in. and smaller Cast iron soil XH or vitrified clay 10 to 24-in. Vitrified clay or concrete 30-in. and larger Concrete 5 feet outside bldg, and un Cast iron soil XH der paving Interior Rain Water Conductors Small Installations Large Installations Black or galvanized wrought iron or steel Schedule 40 ., Cast iron soil XH, black or galvanized wrought iron or steel, Schedule 40 Panel Heating* Type K or L soft copper. Black steel or wrought iron, Schedule 40 Hot Water Heating1* Type K, hard copper or black steel, Schedule 40 Refrigerant* Type K or L hard copper or black steel, Schedule 40 Steam Heating Supply 90 psi and less 100 psi and over Return Pipe All sizes Black steel, Schedule 40, standard fittings . Black steel. Schedule 80. XH fittings Black wrought iron or steel, Schedule 40. Standard fittings Receiver Vent All sizes Galvanized wrought iron or steel. Schedule 40. Standard fittings ___ Sanitary1* Small Installations Waste: lli-in. and smaller 2-in. and larger Vents: and smaller 3-in. and larger Galvanized wrought iron or steel, Schedule 40 Cast iron Galvanized wrought iron or steel, Schedule 40 Cast iron Pipe, Fittings, Welding 693 Table 22. Application of Pipe, Tube and Fittings for Heating and Air Conditioning (Concluded) Application Mateeiai Commonly Used Sanitaryd (Continued) Large Installations Waste: 2-in. and larger Vents: 2-in. and larger Gas (All kinds) All sizes Cast iron Cast iron Black steel. Schedule 40. Malleable iron fittings * Panel heating copper fittings should be soldered with 95-5 solder. Steel fittings should be welded. D All underground feed and return lines buried in slab, should be equipped with fittings as outlined for panel heating. Refrigerant fittings on copper pipe must be wrought copper. All welded fittings should be long turn. House sewer to main should be cast iron XH. There is also the bending moment that may be caused by the flexure of the pipe. For this chapter however, the flexure loading will not be treated for the reason of complexity, as previously stated for the problem of ex pansion. ---------- uuuiuu tto uKi ucoi^ncu ukj cue ucuurng inuinniii, (including buckling)'from the pipe, it is necessary to design the hangers or supports for the maximum bending stress. Even with perfect support spacing there will be some sagging; therefore, the supports should be on a gradient if it is necessary to prevent pockets. Such a condition arises for condensate piping. Typical bending and deflection equations are given in Table 21 in order that supports can be properly sized, and if necessary, pitched. These equations are typical beam equations. If more complex loadings exist, proper beam equations can be applied. Such equations are found in standard texts on mechanics of materials. By application of the equations given in this section and the section of expansion and flexibility, it is possible to determine the proper location and type of support for straight lines. The types are anchors and hangers. Anchors are used to guide the expansion (sliding anchors) or to fix the pipe. They are needed to take the stress out of the line and translate the stresses to the foundations. In that way all stress can be taken out of jfe before it can be transferred to such equipment as boilers or pumps, y means of solid anchors, the anchors can be used to divide the piping to isolated sections that cannot transmit the stresses to other sections. Hangers are used to support the piping and to take out the bending er^pes- They are of the spring, roller, or rod type. Such types gen ii' aUow the free movement of the pipe and yet maintain full support, he Code for Pressure Piping, ASA B31.1, has strict requirements for materials used in hangers and supports. The structural properties j e,a safety factor of five, and consequently there is little chance of failure e to a sudden change of load. 's. a type of support for almost every conceivable requirement. P ete information can best be obtained from a hanger manufacturer. application of pipe, tube and fittings In the application of pipe, tube and fittings it is necessary to comply with regulations contained in local codes and ordinances. Table 22 is