Document ppe8Rvk1Qnpe2z4z8w1BaMBaE

ANALYTICAL METHODOLOGY FOR POLYCHLORINATED BIPHENYLS FEBRUARY 1973 FOOD AND DRUG ADMINISTRATION ROCKVILLE, MARYLAND MQNS 043343 Determination of Polychlorinated Biphenyl Residues in Foods, Feeds, and Paper Products The following outline lists the steps in the analysis of foods, feeds, and paper products currently employed by the Food and Drug Mainistration for residues of polychlorinated biphenyls (PCB). In general, methodology for foods and feeds is that used in analyses for organochlorine pesticides, with auxiliary steps as necessary to separate residues of PCB and pesticides. Extraction of paper products takes advantage of the stability of PCB to treatment with alkalii electron capture GLC determination is the same as specified for food and feed analysis. Methodology for the analysis of food and feeds is described in the FDA Pesticide Analytical Manual Volume I (PAM I). This manual and its revisions are available on request from Food and Drug Administration, Office of the Associate Commissioner for Compliance, S600 Fishers Lane, Rockville, Maryland 20852. Description of the method for paper products and other techniques necessary to analysis for PCB residues are attached. Methodology for Analysis for PCB Residues Food and Feeds WUr Sample Preparation* PAM I, 141. Cut into about l/4"xl/4" pieces; thoroughly mixed. Attachment 1 Extraction PAM I, 211.13 or 212.13, depending on sample type Alcoholic alkali reflux Attachment I Cleanup CH3CS-petr ether partitioning and/or Florisil column chromatography: PAM I, 211.14 or 212.14, depending on sainple type Florisil column chromatography when necessary Attachment I Auxiliary Procedures Separation from pesticide residues, when necessary: PAM I, 251. Supplemental cleanup, when necessary: PAM I, 211.15, Attachment 11 Determination Electron capture GLC: PAM I, 251.15 and 311 Attachments 111, IV Electron capture GLC: PAM I, 311 Attachments III, IV MOWS 043344 -2- Procedures Useful for Confirm.tion GLC with halogen ' specific detection Micro seal, alkali refluxi Attachment II GLC with halogen specific detection TLC - see PAM I, 251.16 for references TLC - See PAM I, 251.16 for references Perchlorination: Attachment v Perchlorination: Attachment V General Attachment VI Attachment VI *Care must be used to avoid contamination of a sample during sampling, storage, or laboratory operations, in particular, storage containers should be checked before using to assure that no PCB are present. The multi - component nature of PCB reaidues challenges even an experienced residue analyst in the identification and quantitation of the residue. Quantitation of a residue (see attachment 12) is made by comparing the magnitude of GLC response from the residue to the magnitude of response from reference Arocloz(s) (Monsanto Company). Judgment must be made as to which reference Aroclor most closely resembles the GLC peak pattern detected in the sample. In many cases, particularly in animal tissue samples, the residue pattern may not resemble any single Aroclor and a choice must be made as to which Aroclor(s) would provide the most accurate result. Since the choice of auxiliary procedures depends to some degree on the identity of the residue, as discussed in PAM X, 251.16, the analyst must develop a high degree of skill in the application of this type of methodology and an ability to Interpret GLC chromatograms correctly. The limits of detectability of the methods are dependent upon: (1) the sensitivity of the determinative step (GLC) to the particular PCB mixture (Aroclor) and (2) the weight equivalent of sample injected for GLC. The magnitude of electron capture response to a given quantity of Aroclor 1242 is about one third of the response to the same quantity of Aroclor 1254. Therefore in the determination of residues exhibiting GLC patterns similar to Aroclor 1242, injection of a larges weight equivalent of sample is required than for residues similar in GLC pattern to Aroclor 1254. When using the electron capture - GLC sensitivity fixed by the parameters defined in PAM I 311.2, the following sample weight equivalents should be injected in order to obtain GLC response sufficient for detection and quantitation of residues similar to Aroclor 1242 at the tolerance levels: MQNS 043345 -3- Products Milk (fat) Dairy Products (fat) Poultry (fat) Complete and finished animal feeds Animal feed components Fish and shellfish Infant and junior foods Paper food packaging material Approximate milligrams sample equivalent for EC-GLC 8 8 4 40 100 10 .4 100 2 0.8. Food and Drug Administration January 22, 197] M0NS 043346 ATTACHMENT Z Extraction and Cleanup for Determination of PCS in Paper and Paperboard By Susan J.V. Young, Charles Finstezvalder*, and Jerry A. Burke, Division of Chemistry and Physics, Food and Drug Administration, Washington, D.C. 20204; *Pood and Drug Administration, 1141 Central Parkway, Cincinnati, Ohio 45202 (To be submitted to Journal of Official Analytical Chemists.) METHOD Apparatus (a) West condenser.--400 mm jacket length with inner drip joint to fit Erlenmeyer. <b) Erleraneyer flask.--250 ml with t outer joint to fit West condenser. (c) Separatory funnel.--250 ml with Teflon stopcock. (d) Chromatographic column.--with Teflon stopcock and coarse fritted plate, 22 mm id x 300 mm (Kontes Glass Co. Vineland, N.J., No. K-420540, size 233 or equiv.) (e) Chromatographic column.--plain, 22 mm id x 300 mm (Kontes Glass Co. Vineland, N.J., No. K-420300, size 21 or equiv.) * (f) Kuderna-Danish concentrator.--500 ml capacity with Snyder column and volumetric and graduated receiving tube. (Kontes Glass Co. Nos. K-621400 and K-570050 or equiv.) (g) Gas chromatograph.--Equipped with electron capture detector and 6*x4 mm id glass column containing either (1) 10% DC-200 or (2) ltl mixture of 15% QF-1 + 10% DC-200 on 80-100 mesh Chromoeorb W(HP). Operating conditions: N^flow, 120 ml/fains temperatures, column and detector 200C, injector 225C; concentric design electron capture detector operated at dc voltage to cause 1/2 full scale recorder deflection for 1 ng heptachlor epoxide when full scale deflection is lxl0~9 amp. ' HONS 04334? 2- Reagents . (a) Florlsil.--60/100 PR Grade: Floridin Co, 3 Penn. Center Blvd., Pittsburgh, Pa. 15235. Transfer Immediately from bulk container to glass containers with glass stoppered or foil lined screw top lids and store in the dark. Heat at least 5 hours but preferably overnight at 130C before use. Store at 130C in glass stoppered or foil covered bottles. Alternatively, store stoppered container in desiccator at roan temperature and reheat at 130C after, two daya. (b) Potassium hydroxide.--Anhydrous pallets. (c) Ethanol.--USP 95% (methanol, redistilled in glass may be substituted.) (d) Alcoholic KOH reflux reagent.--Prepare a 2% (g/ml) solution of KOH in ethanol. (e) Petroleum ether.--Suitable for uae with electron capture gas chromatography (Burdick and Jackson Laboratories Inc., 19S3, 8. Harvey St., Muskegon, Mich. 49442 or equiv.) <f) Polychlorinated biphenyls.--Commercial mixtures (Aroclors) for reference in gas chromatographic determination. (Monsanto Company, St. Louis, Mo.) Attraction . Paper sample should be cut into pieces no larger than about l/4"xl/4" and thoroughly mixed. Weigh lOg of the cut up and well mixed paper material into 125 ml Erlenmeyer flask. Do not pack sample tightly. (Sea note below if the volume of lOg of sample material is greater than about 50 ml.) Add 60 ml 2% ethanolic or methanolic KOH, and fit flask with a West condenser cooled with circulating cold tap water. Reflux gently on steambath for 30 minutes. When refluxing is ccaiplete, rinse down inside of condenser with a mall volume of alcohol before removal from flask. Transfer the reflux solution using a small funnel with glass wool plug to a 250 ml separatory funnel, avoiding transfer of any paper material. Rinse paper and flask with three, 40 ml portions of petroleum ether, combining petroleum ether rinses in the separatory funnel. Add 60 ml water to the separatory funnel and shake vigorously for 30 seconds. Drain lower aqueous layer into a second 250 ml separatory funnel. Add 60 ml petroleum ether to the second separatory funnel and shake vigorously for 30 seconds. Discard aqueous layer and combine petroleum ether layers in first separatory funnel. Rinse second separatory funnel with a few small portions of petroleum ether, M0NS 043348 3- collecting rinses in first separatory funnel. Wash petroleum ether with three, 40 ml portions of distilled water, discarding each wash. Dry petroleum ether through a 25 mm x 50 mm column of anhydrous NajSOj, collecting eluate in a Kuderna-Danish concentrator. Rinse separatory funnel and then column with three* about 20 ml portions petroleum ether, collecting rinses. Concentrate combined petroleum ether extract end rinses on steam bath to about 5 ml. Extract is ready for cleanup on Plorisil column. Zf experience with particular sample types indicates that Florisil column cleanup is not required, proceed to gas chromatographic determination. Note: Adequate extraction of low density paper such as newspaper or tissue paper will require adjustment of either the amount of sample downward from 10 grams or the volume of reflux solution upward from 60 ml. If possible reduce the weight of the sample material below 10 grams to a quantity that is completely covered and vetted by 60 ml of the reflux reagent. If a larger amount of sample (not to exceed lOg) is required, use a volume of reflux reagent to completely cover and wet the sample. Increase in volume of reflux solution over 60 ml must be accompanied by proportional increases in volumes of petroleum ether rinses of sample, water diluent added to the alcoholic reagent in the separatory funnel, and sire of Erlenmeyer flasks and separatory funnels. Cleanup Add lOg of Florisil to 22 mm id chromatographic tube. Settle column of Florisil by gentle tapping of chromatographic tube. Top column with about 1/2" anhydrous Pre-wet column with 20 ml petroleum ether. Place Kuderna-Danish concentrator with volumetric collection vessel under column to receive eluate. Transfer petroleum ether extract to column letting it pass through column at about 5 ml/min. Rinse container with three, 5 ml portions petroleum ether transferring each to column, and rinse walls of chromatographic tube with additional nail portions of petroleum ether. Elute column at about S ml/min with 150 ml of petroleum ether. Concentrate eluate to suitable definite volume in Kuderna-Danish evaporator. If volume less than 5 ml is required, use 2-ball micro Snyder or micro Vigreaux column during final vaporation. Eluate is suitable for analysis by gas chromatography with electron capture detection. Note: Waxes, if present in the extract, can be removed prior to Florisil chromatography by partitioning between petroleum ether and acetonitrile. Pesticide Analytical Manual, Vol. I., 211.14. HONS 043349 ATTACHMENT III Gas Chromatographic Determination of PCB The following is taken from changes in AOAC official multi-pesticide residue methodology, Chapter 29.001, made to include PCB in the gas chromatographic determination. To appear in March, 1973, Journal of the AOAC, "Changes in official Methods of Analysis of the Association of Official Analytical Chemists Made at the Eighty-sixth Annual Maeting, October 9-12, 1972". "Sec. 29.017 Gas Chromatography, introductory par., was revised as follows' "(Applicable to chlorinated pesticides, phosphated pesticides, and polychlorinated biphenyls (PCB). Method is applicable to PCB residues when present alone in sample. If pesticidal or other compds are detected in chromatogram of the PCB residue, other chemical or physical operations must be applied to eliminate or mlmlnlze their Interference before PCB quantitation.) Inject suitable aliquot (3-8 pi) of coned eluate from Florisil or MgO-Calite column contg amt compd within linear range into gas chromatograph, 29.008, using 10 ul syringe. Tentatively identify residue peaks on basis of retention times. Measure area or ht of residue peak(s) and det. residue amt by comparison to peak area or ht obtained from known amt appropriate ref. material(s). To insure valid measurement of residue quantity, size of peaks from residue and ref. std should be within +25%. chromatograph ref. material(s) Immediately after sample. Measure PCB residues by comparing total area or ht of residue peaks to total area or ht of peaks from appropiate Aroclor(s) TM' (Monsanto Co., BOO N. Lindbergh Blvd, St. Louis, MO 63166) ref. materials. Measure total area or ht response from common baseline under all peaks. Use only those peaks from sample that can be attributed to chlorobiphenyls. These peaks must also be present in chromatogram of ref. material. Mixt. of Aroclors may be required to provide best match of CLC patterns of sample and ref." M0NS 093350 ATTACHMENT II Micro Scale Alkali Treatment lor Use in Pesticide Residue Confirmation and Sample Cleanup by Susan J. V. Young ami Jerky A. Burke Divi$ioH of Chemical Technology Bureau of Foodi Food end Drug Adminhtration IFuhington, D. C. 20204 Procedures Involving elkell treatment for dehydrochlorlnatlon of certain organochlorine pesticldee and saponification of fats have long been employed In pesticide residue analysis. In 1942 Brand and Busse-Suoderaan (1), and in 1946 Soloway et el. (2), studied rataa of dehydrochlorlnatlon of DDT. Mills (3) used refluxing alcoholic KOK In the cleanup of fatty foods for paper chromato graphic detection of alkali-stable organochlorine pesticides. Klein and Watts (4) used alcoholic NaOH to dehydrochlorlnate ,*- and ,'-DDT, ,j>'-TDE, end Perthane prior to gas chroma tographic separation of ehe respective olefins. These Investigators called attention to several earlier uses of alkali dehydrochlorlnatlon in pesticide residue chemistry. Recent literature contains ntnerous references to application of this treataent in pesticide residue analyses, Including an adaptation for use in a pre-gas chromatographic (CLC) column (5). In spite of the knowledge of this reaction we have observed that it Is not fully anU effectively utilized by residue laboratories for forming derivatives, gaining information for identity confirmation, or obtaining better cleanup of troublesome extracts. This Is probably because the procedure has not been described In detail for simple micro scale application in aultiresldue analysis. The purpose of this work was (JL) to arrive at optiaua and convenient parameters of the alkali treataent In order to obtain rapid dehydrochlorlnatlon resulting In product solutions suitable for analysis by CLC; (2) to obtain coaplete yield and recovery of olefins from a number of bls(phenyl) chloroethane pesticides; (3) to determine the effect of the treatment on several important pestielde and industrial chemicals; (4) to describe In detail the procedure for routine application in the residue analytical laboratory. METHOD Reaients and Apparatus (a) Potassium hydroxide - Anhydrous pellets. (b) Ethanol - US? 932. (c) Hexane - Suitable for use with electron capture gas chromatography (Burdick and Jackson Laboratories, Inc. 1953 S. Harvey St., Muskegon, Mich. 49442). 160 SaltaIn ( talnmMMil CmmIkmIm I T*l*Ui. V*L 1. lit, i/i l1t g Sfwlr*fVrU| Nw Vttk Inr. QVi351 *0NS (d) Micro condcnttr - 19/22 J; K-569250 (Kontes Glass Company, Vineland, N. J. 08360). () Concentrator tube - Mills type, 19/22 J with stopper, 10 ml graduated In 0.1 nl up to 1.0 ml; K-570050 (Kontes Class Conpany). (f) Alkali dehydrochlorlnatlon reagent - Dissolve 2 g KOH in 100 ml ethanol. <8> Ethanol - water, 14-1 * Combine equal parts by volume of distilled water and ethanol. (h) Cas chromatograph - Equipped with electron capture detector and 6* x 4 an id glass column containing either (1) 10Z DC-200 or (2) 1:1 mixture of 13% QF-1 + 10% DC-200 on 80-100 mesh Chromosorb W(HP). Operating conditions: N2 flow 120 ml/mln; temperatures, column and detector 200C, Injector 223C; concentric design electron capture detector operated at dc voltage to cause 1/2 full ecale recorder deflection for 1 ng heptachlor epoxide when full ecale deflection la 1 x 10**9 amp. Procedure Accuretely plpet. Into a 10 ml Kllle tube, 2 ml of a petroleum ather aolution of sampla extract (6Z or 15% Plorlsll eluate (6) I containing concentrations of pesticides suitable for subsequent GLC analysis. Add 1 ml of 2% ethsnolic KOH and a few carborundum chips and fit the tube with a micro condenser. (Mote: Avoid getting slksli on the ground glass Joint* light greasing of Joint with silicone lubricant may prevent sticking.} With s test tube clamp, hold the tube over an opeiftng in the eteam bath lo such a manner that gentle boiling occur*. When the volume hse been reduced to about 1 ml, Insert the tub* completely into the steam bath opening and hest vigorously for IS mlnutss or until the volume reaches 0.2 ml. Remove tube from the steam. If a precipitate has formed, ss Is often the case with extracts containing fatty substances, add a few drops of 2% ethsnolic KOH and warm gently In steam with swirling until the precipitate dissolves. After the aolution has cooled slightly, add about 2 ml *thanol-H20 (1+1). Allow solution to reach room temperature and plpet 1 or 2 ml hexane Into tube. Stopper tube with ground glass, invert, shake vigorously for about 30 seconds, and allow solvent layer to separate sharply. With microliter syringe, carefully withdrew aliquot of upper layer for determination by GLC. (Note: Separation of phases should be eharp so that solution withdrawn for GLC analysis will be free from alkali.] Discussion Dsvslopment of Method ' Initial experimentation was performed to establish the reaction con ditions which would give complete and rapid dehydrochlorination of *-00%, o,*-DDT, ,*-TDE, o,'-TDE, methoxychlor, and Ptrthane and which would permit complete recovery of the respective olefine. Work was done to determine the effecc on olefin formation of fatty substances not removed during sample cleanup and the capacity of the reaction to eliminate fatty substances. 161 MQNS Q4335i Stversl considerations found necessary for practical and reliable use of the alkali treatment have been incorporated into the method end are briefly discussed. The steam bath was chosen as a source of heat because of its ready availability and convenience. The Hills reaction tube was fitted with a micro condenser to eliminate losses due to volatilization, which often occurred in the absence of the condenser, both KOH end HsOH have been used to the satis faction of previous Investigators. The more frequent use of KOH by other workers and its higher solubility in ethanol raada It the choice for this work. An alkali concentration of 2% has been widely used, end was found ideal for treatment of aliquots of deaned-up sample extracts containing quantities of bls(phenyl) chloroethane pesticides ranging from a few nanograms tro 100 ug. In order to provide sufficient reflux time and temperature it was nscessary that the Initial volume of ethanol be In excess of 0.5 1. When smaller volumes were used, dehydrochlorlnatlon wss usually Incomplete. Emulsions often occurred during extraction of the olefin into hexane after saponification of fatty substances. The uae of ethanol + water (1 + 1) Instead of water as the diluent resulted in s sharp aeparatlon of hexane and aqueous layers. Recoveries of olefins were not adversely affected if the ethanol content was less than about 702. Less than 302 ethanol did not adequately enhance separation of the two layers. The non-volatile fatty substance transferred to acetonitrile by partitioning a petroleum ether solution of butterfat with acetonitrile was used in tests to evaluate the effects of fatty substances on the reaction. Experiments in which vsrylng volumes of 22 ethanolic KOH were used to saponify 350 mg portions of this butterfat showed that each 1 *1 of 22 KOH would saponify about 50 mg of the fat. When the weight of fatty substances exceeded about 50 mg, complete dehydro- ehlorinatlon of Perthane (40 ug) and methoxychloc (4.0 ug) was not obtained. However, ,*-DDT (9.0 ug) was completely dehydrochlori- nated In the presence of 100-120 mg of fat. Additional experiments* tlon showed that completa dehydrochlorlnatlon of mathoxychlor and Parthane did not occur until Che fat was completely saponified; * these were the bls(phenyl) chloroethanes most reslttent to dehydrochlorlnatlon. Quantities of Perthane and ,*-DDT up to 100 pg In tht presence of not more than 50 mg butterfat wart readily dehydrochlorlnated with 1 ml of 22 KOH at steam bath temperature; dehydrochlorlnatlon of larger amounts of pesticide was not attempted. Hexane, because of its higher boiling point and greater ease of drawing into a microsyringe, vaa used Instead of petroleum ether, to extract the olefin after reaction In order to avoid possible errors In quantitation. Effect on Selected Chemicals The dehydrohalogenation reaction, as described under "Method", was applied to ,'-DDT (0.6 ug), o'-DDT (0.6 ug), ,'-TDE (2.0 Ug), ,*-TDE (0.4 ug), mathoxychlor (4.0 ug), and Perthane (40 pg). Quantities shown In parentheses were chosen for ease in CLC determination. The pesticides were treated individually In petroleum ether, In 62 ethyl ether/petroleun ether Florlsil eluates (6) containing tht equivalent of 6 g of kale, and in 163 MONS 043353 petroleum ether containing 30-60 mg of fatty substances extracted from butter by partitioning (6) between petroleum ether and acetonitrile. Gas chromatography with electron capture detection, operated as described under "Method", was used for all determinations. Each pesticide was completely altered in each of the solution types, l.e., none of the parent compound remained after treatment as described under "Method". Percent recoveries of Che rospective olefins were calculated according to the following equation: vt. olefin compound determined by CLC ^ wt. parent compound represented in aliquot to CLC wt. parent conpound/mol. wt. wt. olefin coapound/mol. wt. * Recoveries of olefins approximated 100Z and ranged from 86Z for ,*-DDE and o,'-TDE olefin in petroleum ether to 110Z for ,'-DDE in the extract from butter. Two olefin derivatives, the cla and trans isomers, are formed from c>-TDE (7). These have Identical retention times on the two GLC columns used in this work end were quantitated as a single compound. . Several additional common organochlorlne pesticides and polychlori nated biphenyls (PCB) were subjected to the described alkali treatment. All testa were made with petroleum ether solutions of the chemical under study. The quantity of each chemical was chosan for ease of determination by GLC and la given In parentheses. Polychlorinated biphenyls ranging from 21 to 60Z average chlorine content were stable to this treatment. Complete recoveries were obtained for the commercial PCB mixtures, Aroclors 1221 <16 ug), 1232 (16 ug), 1242 (16 ug), 1254 (8 ug), and 1260 <8 ug). Recoveries of unchanged aldrin (0.4 ug), dieldrln (0.4 ug), and tndrln (0.4 ug) ranged from 70 to 90Z. No alteration products vers detected. Heptachlor (0.4 ug) and heptachlor epoxide (0.4 Ug) were markedly affected; recoveries of the original compound ranged from 30 to 50Z. Minor CLC peaks were observed on the 10Z DC-200 column at retention times relative to aldrin of 1.63 after treatment of heptachlor epoxide and 0.59 and 0.93 after treatment of heptachlor. The alkali treatment completely eliminated lindane (0.2 Ug) and the alpha (0.2 Ug), beta (0.2 ug), and delta (0.2 ug) Isomers of BHC. Following the reaction, only small early eluting gas chromatographic peaks, preaimtably from trlchlorobenzencs, wera obaervtd. About 40Z of mirex (4.0 ug) remained unchanged after reaction; sometimes s minor CLC peak appeared at a retention time relative to aldrin of 1.83 on the 10Z DC-200 column. lfkS MONS 043354 Endoeulfan I and II, treated separately, were completely eliminated. Each isomer gave a single alteration product with retention time relative to aldrln of 1.82 on the 10Z DC-200 column and 2.23 on the ltl 10Z DC-200/1SX QF-1 column. The peek height of the alteration product was approximately one-tenth the peak height of the parent compound. A structure for this derivative hee been propoeed (8). Endoeulfan sulfate elao was completely eliminated. Two alteration products were obtained with retention times relative to aldrln of 0.28 and 0.38 on the 10Z DC-200 column. Dlcofol (1.0 Ug) wae completely eliminated but only 652 of the major alteration product, 4,6'-dlchlorobenzophenone, was recovered. A minor peak was observed in the ehromatogrea at a retention tine relative to aldrln of 1.71 on the 102 DC-200 column, the 4,6'dlehlorobensophenone (2.0 Mg) was not affected by treatment with alkali. The products resulting from alkali treatment of toxaphene (10.0 Mg) gave a eulticoeponent chromatogram but consisting of components with earlier retention times than toxaphene Itself. The electron capture GLC responses to sulfur (20 ug), frequently encountered In residue analysis at retention times relative to aldrln of 0.23, 0.5S, and 1.13 on tha 10Z DC-200 column, ware eliminated by the alkali treatment. Application of Method The most obvious use of the alkali treatment la to form the olefine of bis(phenyl) chloroethane pesticides for confirmation of rasidue Identity. The complete yield and recovery of the olefin derivative makes possible quantitative confirmation of a residue of the parent pesticide. For example, a residue of ,'-DBT can be quantitated before alkali treatment and verified by quantitation as ,'-DDE after treatment. ' In addition the CLC retention time region of the reacted compound ean be examined for presence of peaks from unreacted and presumably interfering subacancea. We have found the alkali treatment especially useful In connection with the real or suspected presence of residues of PCS. In this case the characteristic olefin derivatives of ,'-DDT, o,*-DDT, and ,'-TDE can be formed end the CLC retention time region underlying the parent compounds can be examined. The stability of PCB to alkali, with no change in the GLC pattern, is e characteristic which can be readily utilized In conflrmetlon of the identity of this complex residue. The high recovery of unreacted dieldrln, endrin, and aldrln following alkali treatment likewise can be of velue in the confirmation of identity of these pesticides. " !4 MONS 043355 TABLE 1 Compounds Treated with Alkali According to the Described Procedure Compound Approximate Amount Altered, X Major Alteration Products Detectable by GLC Approximate Amount of Parent Compound Changed Co Alteration Product, X p.p'-DDT o.p'-DDT p.p'-TDE o,p'-TDE 100 100 100 100 Perthane 100 methoxychlor 100 dlcofol 100 4,4*-dlehlorobenzophenone 0 lindane 100 isomers of SIC 100 endosulfan 1 100 endosulfan II 100 endosulfan sulfate 100 mirex ' 60 heptachlor 50-70 heptachlor epoxide 50-70 sldrin 10-30 dleldrln 10-30 endrin 10-30 Coxaphene apparently greatly altered p,p'-DDE o.p'-DDE p,p'-TDE olefin els o,p'-TDE olefin trans o,p'-TDE olefin Perthane olefin amthoxychlor olefin 4,4'-dlchlorobenzophenone -- presumably trlchlorobenaenes presimiably trlchlorobenaenes 1.82 DC-200ii 2.23 mixed! 1.82 DC-200i! 2.23 mixed! 0.28, 0.38 DC-200i 1.83 DC-200! 0.59, 0.93 DC-200! 1,63 DC-200i .... --------* substances with earlier BKTA than toxaphene 100 100 100 100 100 100 65 --... ... --... -- ... ... ... y O' y, O f \f . Compound TABLE I (continued) Approximate Amount Altered, X Major Alteration Products Detectable by CLC / Approximate Aaount of Parent Compound Changed to Alteration Product, X polychlorinated biphenyls: Arochlors 1221, 1232, 1242, 1254, and 1260 . sulfur: 0.23, 0.55, 1.13 DC-200" 100 --. - Retention tine teletlve to sldrin on the 101 DC-200 column, described under "Reagents and Apparatus (h)". Structure elucidated by Greve and Wit (8). - Retention tine relative to aldrln on the 1:1 QF-l + 10X DC-200 coluan, described under "Reagents and Apparatus (h)". - Cleaned-up extracts cf soma samples nay contain non-peeticldal substances which give rlae to electron capture response. Other extracts say contain fatty aubatances, not removed by the clean up, which can prohibit application of some tests, e.g., thin layer chromatography. This la particularly true of the 15Z ethyl ether/petroleum ether Florlell column eluate (6) for non-fatty samples such aa carrots and fatty samples such as some fish. Electron capturing substances present in carrots must be eliminated before determination of dleldrln and/or andrln residues. Treatment with alkali serves wall for this purpose. Extracts of fatty samples may require treatment to ellmlnete both electron cepturlng substances and non-volatile fatty substances. In many lnetancee thin layer chromatography or mlcrocoulometrlc GLC cannot be accomplished prior to alkali treatment. Electron capture responses to sulfur, often a source of annoyance to the residue chemist, are also eliminated by this treatment. These common uses of the alkali treatment serve to Illustrate its value to the residue chemist. The directions for laboratory application outlined here should enhance the use of this procedure of long standing. References 1. BRAND, K. and BUSSE-SUNDERMAN, A., Berlchte. 73 B 1819 (1942). 2. SOLOWAY, S. B., SCHECHTER, M. S., and JONES, H. A., Soap and Sanitary Chemicals, 1946 Blue Book, 18th Ed., 213 (1946). 3. MILLS, ?. A., J. Asa. Offlc. Anal. Chem. 42, 734-740 (1939). A, KLEIN, A. K. and WATTS, J. 0., J. Asa. Offlc. Anal. Chem. 47, 311-316 (1964). 3. MILLER, C. A. end WELLS, C. E., J. Ass. Offlc. Anal. Chem. 52, 348-553 (1969). 6. Pesticide Analytical Manuel, Vol. I, Food end Drug Administration, Washington, D. C., 2nd Ed., 1968; Revised July 1969, July 1970, ' end April 1971. 7. KRAUSE, R. T., Private Communication, Food and Drug Administration, Washington, D. C., May 1970. 8. GREVE, P. A. and WIT, S. H., J. Aar. Food Chem. 19, 372-374 (1971). 167 MONS 043358 Reprinted from ATTACHMENT IV Journal of Chromatography , Heavier Publishing Company. Amsterdam Printed in The Netherlands CHROM. 6243 - GAS CHROMATOGRAPHIC DATA FOR POLYCHLORINATED BIPHENYL COMPONENTS IN SIX AROCLORS* JUDITH A. ARMOUR Division ofChemical Technology, Food an4 Drug Adininutrolion, Woskington, D.C. roioy (U.S.A.) (Firat received April nth. 197a; revised manuscript received July 5th, 1972) SUMMARY Illustrations of gas chromatographic curves, relative retention times, and re sponse data from 10% DC-200 and i:t 15% QF-x/10% DC-200 on 80-100 mesh Chromosorb W HP columns with electron capture detection are compiled for six Aroclors*. Aroclors* are commercial mixtures of polychlorinated biphenyls com monly used as analytical references for polychlorinated biphenyl residue deter mination. INTRODUCTION The industrial chemicals known as polychlorinated biphenyls (PCB), which Itave become widespread environmental contaminants1**, are generally determined by essentially the same techniques used for organochlorine pesticides4 and may act as interferences in the gas-liquid chromatographic (GLC) determination of pesticide residues. Because there is no standard PCB and individual chlorinated biphenyl compounds are not readily available, it is necessary to rely on Aroclors* as analytical references for PCB residue determinations. . Aroclor* is the general tradename for commercial mixtures of PCB manufac tured in the United States by Monsanto Company. Each Aroclor is a mixture of chlorinated biphenyls (1200 series), chlorinated terphenyls (5400 series) or a combina tion of chlorinated biphenyls and terphenyls (4400 series). The last two digits of the identifying number indicate the percentage weight of chlorine, e.g., Aroclors 1254 and 1260 are biphenyls containing 54 and 60% chlorine, respectively4. GLC patterns of PCB residues in environmental samples have generally resembled Aroclors 1254 and 1260, although the possibility exists that residues may derive from any of the Aroclors. The GLC retention times, relative peak sices, peak shapes, and overall peak pattern of PCB residues must bs carefully compared to the corresponding data for the Aroclors in order to determine the Aroclor(s) that most closely resemble the residue. Because the magnitude of total area varies significantly for the same weight of different Aroclors, the quantitative value determined for the PCB residue depends J. Chrommiogr., 7] (1972) >75-282 HONS 043359 S76 J. A. ARMOUR upon which Aroclor(s) is chosen for quantitation reference. The interpretation and evaluation of GLC chromatograms in PCD determinations is augmented by ready access to relative retention times, response data, and reference chromatograms of the various Aroclors. Data for these GLC characteristics of six Aroclors, obtained by using two GLC columns regularly employed in our laboratories', are presented here. Data are not presented for Aroclors 123a, 1268, 5443, 5460, and 4465. Aroclor 1232 has been commercially prepared7 by blending appropriate quantities of Aroclors 1221 and 1242 to obtain 32% total chlorine; chromatograms of material obtained from different lots revealed substantial differences between some lots. Aroclor 2268 was not available at the time of this work. GLC at the described conditions of Aroclors 5442 and 5460 (chlorinated tcrphenyls) and 4465 (mixture of PCB and chlorinated terphenyls) resulted in multicomponent chromatograms with peaks emerging at retention times extending to several hours; several hundred nanograms were required for detection of late-eluting constituents. These GLC parameters are considered unsuitable for detec tion and measurement of the polychlorinated terphenyls. A system utilizing parallel columns with liquid phases of 1% OV-101 and 3% Dexsil 300 operated at 240 has been devised for GLC of both the polychlorinated terphenyls and PCB1. tXPKRSMENTAL GLC data were obtained with a gas chromatograph equipped with an electron capture detector and 4-mm x 6-ft. glass columns, packed both with 10% DC-200 on 8o-xoo mesh Chromosorb W HP and a i:x mixture of 15% QF-i plus 10% DC-200 on 80-100 mesh Chromosorb W HP*. Operating conditions: nitrogen. I20ml/mtn; column and detector temperature, 200; injection temperature, 225. The concentric design electron capture detector was operated at a d.c. voltage to produce half full scale recorder deflection for 1 ng heptachlor epoxide when full scale deflection is i x 10** A. Recorder speed was \ in./min. Different concentrations of Aroclors were injected at the conditions given to determine the quantity necessary for approximately half full scale recorder response or enough response to illustrate all the characteristic constituents of a particular Aroclor. Retention times were measured in millimeters from the leading edge of the response to the solvent and reported relative to the retention time of the pesticide aldrin. These conditions and manner of reporting GLC data for Aroclors were chosen to conform to GLC data compiled in the Food and Drug Administration Pesticide Analytical Manual* for a large number of pesticides. RESULTS The following information has been compiled in the tables and figures to be a source of reference and comparison for the GLC behavior of PCB: retention times, response data and illustrations of chromatograms for six Aroclors from two GLC columns. Table I lists the quantities necessary for approximately half full scale J. Chrommt^r., 72 (1972) 175-282 HONS 043360 GC DATA FOR POLYCHLORINATED BIPHENYLS IN AROCLOBS *77 TABLE 1 fVANTITIII or AdOClOU HSCBSSARY fOB AfSHOXIMATtLy HALF PtIU KAU RBCORDR* M|roi||* Arodor Nonogromi for ift f.s.r. DC-too* QF-l/DC-too* last ttx 1)4* **54 ts6o tabs So 4 4 5 so so . 60 4 3 3 SO so Quantities of Aroclor mixtures to produce approximately half full scale recorder response (1/1 f.s.r.) for major Aroclor components or sufficient response to detect all the characteristic Aroclor constituents. * GLC column and detector conditions are fiven under bxpbrimkntal. TABLE II GL.C SITIMTION TIMS DATA rox SIX AXOCIORB Support msteris): Chromosorb W HP. 80-100 mesh; stationary phase: 10% DC-roo (6 A. x 4 mm l.D. column); carrier gas: nitrogen. iso ml/mm: temperature: toe*; detector: electron cap* ture (tritium); sample site: quantities necessary for approximately half full scale response (see Table 1); data given in: retention sequence relative to aidrin from solvent peak. A rodor fair O.SI 0.16 o.ji 0.36 0.39 o,jt 0.59 0.64 0.69 *75 O.SI 0.99 **7 1.4* 1.3* t.76 1.86 s.ol t.t> 1.63 J.10 Arodor 1343 39 O.JI *57 0.67 0.7s .S6 0.96 1.03 I.SS *39 *49 *74 1.83 t.ao a.36 , Arodor JS4S 0.3* -57 .67 0.80 0.83 0.96 I.OJ i.*3 *39 1-49 *74 >4 t.so *54 34 Aroclor *54 0.87 0.98 I.OJ i.*7 r.ss *78 x.88 t.so S.63 3.08 S.60 4.10 43 49 .* Aroclor It6o Arodor 1*63 i.s8 * 5 1.86 *-7 a.ai s.63 i*< !> J.JO 4.* 49 5* 6.30 7o 9. to t.s6 *.30 1.85 *.07 s.as a.61 3.8s 3.06 3-3 4.10 . 4 90 5.80 ' 6.40 6.60 7.80 9.10 /. Ckromotogr., 7* (197s) *73-18* HONS 043361 *7* J. A. ARMOUR recorder response or for enough response to illustrate all the characteristic constituents of a particular Aroclor. Tables II and HI give the retention times relative to aldrin for all the peaks present in six different Aroclors. These tables are arranged to readily show similarity and differences in the GLC elution pattern of the various Aroclors. Peaks with similar relative retention times in the different Aroclors are not necessarily responses to the same compound. Figs. 1-3 are gas chromatograms of six Aroclors from the 10% DC*200 column: Figs. 4-6 are gas chromatograms of six Aroclors from the 1 :i 15% QF*i/ro% DC*200 column at the specified conditions. The GLC data for PCB presented here should be a useful reference for evalua* tion and interpretation of GLC chromatograms for PCB residue determinations. TABLE 111 GLC RBTBNTION 71MB DATA FOR BIX AftOCLORS Support material: Chromosorb W HP. 80-100 mesh; stationary phase: 1:1 15% QF*i(io% DCoo (6ft. x 4 mm l.l>. column); carrier gas: nitrogen, iso ml/min; temperature: 300*; detector: electron capture (tritium); sample tire: quantities necessary for approximately half full scale recorder reeponee (see Table 1); data given in: retention sequence relative to aldrin from solvent peak. Arcelor i$t Arcelor *>4* Aroclor "4* Aroclor *>54 Aroclor j*6o Aroclor t6a 0.30 .39 O.36 O.39 3J 57 O.71 0.78 e.88 I.OS 1.10 r.jr l.jj 1.83 1.96 s.oB t.e6 J4 S.68 s.84 0.4I O-SJ 0.61 0.73 0.81 0.90 1.03 1.09 *34 I.53 1.8a 1.97 1.36 3.60 J*4 -3J 0.61 0.73 0.81 0.90 1.03 1.09 * 34 I.53 l.8l *97 *.36 3.60 yu 0.87 I.OX 1.33 *5* 1.83 1.96 *34 *68 3.80 3.10 3*5 5 90 4.30 3-00 6.to t.31 *53 1.86 s.14 s.s6 3.66 3.88 3.33 3.50 3 90 4.30 3.00 6.10 6.50 6.00 9.40 r.31 *53 1.84 3.08 *4 x.66 1*8 3.33 3.30 3 9 4-30 5 00 6.10 6.30 7-4 9 3 11-9 /. Chromotogr,, 7a (197*) 373-183 HONS 043362 CC DATA FOR POLYCHLORINATED BIPHENYLS IN AROCLORS *79 *9 * Rp'-oor Tinw(min) Fig. i. GLC separation on to% DC-*oo column of nong Aroclor 1231. GLC condition* are given under sxpcrimsmtal. Fig. a. GI.C separation on i% IXI-joo column of (A) 50 ng Aroclor 1242 and (H) 50 ng Aroclor 1*48. GI.C conditions are given under ixpsriminial. HONS 043363 aBo J. A. ARMOUR i ft* io lb M 30 3ft 40 " 48 90 AlOrm p,*`- OOT '8 ,.f{kAAA^------------ . ft* 10 Alarm 6*20 ar'-OOT 30 3ft 40 48 ftOftft c ft* io Alarm e ra 23 so ar'*0OT TlnwImM 40 aft 90 ftft Fig. y GLC separation on to% DC-ioo column of (A) ja ng Aroolor 1154, (B) so ng Aroclor late AOd (C) song Aroclor is6x. GLC condition* arc given under sxreniMSNTAi.. Fig. 4. Cm chromatographic separation on 1:1 15% QF*l/io% DC-aoo of iso ng Aroclor last. GLC conditions are given under ixnaiMINTkL /. Chromdogr., 71 (197a) S7J-a$a . MONS 043364 281 A Fig. 5. Got chromatographic separation on 1:1 13% QF-t/to% PC-200 of (A) 50 ng Arocior 1242 ud (II) 30 ng Arocior 1248, CLC conditions are given under experimental. Tim# (mm| Fig. 6. Gm chromatographic reparation on t :t 15^ QF-i/to% DC-200 of (A) ,w ng Arocior 1251. (II) 20 ng Arocior 1 il, ami (C) 20 ng Arocior l il>a. (il,C conditions arc given umter ixmiMKKTAL. HONS 043365 s8s J. A. ARMOUR REFERENCES I D. B. Peakall and J. L. Lincsr. Biotcitnte, to (1970) 958. L. M. Rxvnolok, Rtttdne Rev., 34 (1970) 27. j R. W. UlftSMKoucN, P. Ksicmb and H. S. Olcott, Bull. Ekvtron. Contam. TomUoI., 4 (1969) *. 4 J. A. Armour and J. A. Burkk, J. An. Off*. Anal. Ckrm.. 53 (1970) 701, 5 Aroclot Plaxlititers. Technical Bulletin O/PL-306, Monunto Co.. St. Louie. Mo. 6 Prtticidt Analytical Manual. Vol. I. Food and Oruf Administration. Washington. D.C.. 1968. 7 Monsanto Chemical Company, private communication. November. i97* W. W. Wsencki. U.S. Food and Drug Administration, private communication. January, 197*9 J. Burke and W. Holswade, J. An. Offie. Anal. Ckrm., 49 (1966) 374. J.Ckramaiogr., 7a (197a) 273-28* MUNS 043366 ATTACHMENT V Quantitative Perchlorination of Polychlorinated Diphenyls as a Method for Confirmatory Residue Measurement and Identification Dy J. A. ARMOUR (Division of Chemical Technology, U. S. Food and Drug Administration, Washington, D. C. 20204) To be published: Journal Association Official Analytical Chemists, July, 1973 Abstract The perchlorination procedure for derivatization of PCB described by Derg, Diosady, and Rees has been modified to achieve a micra scale quantitative conversion (greater than 90%) of conx*ercial PCB preparations, (Aroclorj/Q, to decachlorobiphenyl. Cleaned up sample extracts containing PCB residues (1 yg-20 pg) are reacted with antimony pentachlo~ide in the preserce of-chloroform toHEorja dfecachlorobiphenyl. This procedure converts a multicomponent mixture to a single derivative detectable by EC-GLC thus providing an easy method for quantitating and identifying PCB re*idues and at the same time increasing the sensitivity of letection. The usefulness of the perchlorlnation procedure is demonstrated by comparing results for environmentally contaminated samples quantitated by measuring the total area of the EC-GLC response for the residue against the Aroclor it most closely resembles to results obtained by measuring the single peak of the decachlorobiphenyl derivative and expressing the results in terms of the particular Aroclor. HONS 043367 Quantitative Pcrchlorination of Polychlorinated Diphenyls as a Method for Confirmatory Residue Measurement and Identification By J. A. ARMOUR (Division of Chemical Technology, U. S. Food and Drug Administration, Washington, D. C. 20204) Introduction , Analytical methods normally employed for the extraction, cleanup, and detection of polychlorinated biphenyl (PCD) (1-3) residues are generally * those used for organochlorine pesticides (4). Quantitative values are usually obtained by measuring the total area of a PCB residue response as shown on a gas chromatographic tracing using an electron capture or microcoulometric detector and comparing it with the total area of a similarly obtained response of the commercial PCD preparation (Aroclo^ (5) It most closely resembles (6). This has proved to be a practical procedure for quantitation, however, it is limitod because of lack of sensitivity, the multicomponent nature of PCB residues, alterations in residue pattern due.to metabolic and environmental changes, and the need to rely on commercial Aroclors as reference materials. Procedures to convert all PCB components to a single derivative, e.g. biphenyl or decachlorobiphenyl (DCB), that is indicative.of the total PCD residue and could be used for quantitative purposes have previously been reported (*7-8). In this study, the perchlorination procedure described by Berg, Diosady, and Rees (7) has been modified to achieve complete HONS 043368 -2- conversion on a microscale of all PCB components in a cleaned up sample extract to docachlorobiphenyl, thus providing a qualitative and quanti tative confirmatory procedure for PCB determination. A quantitative value obtained by measuring the single GLC peak of a DCS derivative against a DCB standard of known purity reinforces the residue value achieved by the measurement of a multicomponent PCB residue. It also greatly increases the sensitivity with which PCB can br. detected and measured. Measuring the single GLC response for DCB will also minimize necessary Analytical judgments involved in the physical measurement of the GLC curve of a multicomponent residue (i.e. position of baseline and method of integration) and in the discrimination between PCB and non PCB components. Methodology Reagents Antimony pentachloride - Allied Chemical Reagent Code 13^5. Sodium Sulfate - anhydrous, granular; it may be necessary to wash with acetone and ethyl ether to remove electron capturing substances. HC1 * 6N solution (1+1 dilution of concentrated HC1 in water). .Sodium Bicarbonate - 10% weight/voluroe aqueous solution. Solvents - Hexane, chloroform, and methanol suitable for use in pesticide residue analysis; distilled-in-glass product is satisfactory. (Available from Burdick and Jackson Laboratories Inc., 1953 S. Harvey St., Muskegon, Mich. 49442) 4336^ MOWS -3- ftpparatus ' (a) Vacuum hydrolysis tubo - 150 mm X 10 mn o.d. with No. 4 Teflon valve (Kontes Glass Co. K-896860-0004) or Carius pyrex combustion tube 200 mm X 8 nun i.d. X 10 mm o.d. (Corning 8640). (b) Silicone oil bath and heating element - Capable of maintaining temperature at 165-175C. (c) Kuderna-Danish evaporative concentrator - With Snyder column and collection tube, S00 ml capacity (Kontes Glass Co. K5470000, or equivalent). (d) Micro-Snyder column * 19/22 column size 2-19 (Kontes Glass Co. K569001, or equivalent). (o) Gas chromatograph - Equipped with concentric design electron capture detector .operated at n dc voltage to produce 1/2 full .scale recorder deflection for 1 ng decachiorobiphcnyl when full scale deflection Is 1 X 10'9 amps, and 6' X .4 mn i.d. glass column of either (1) 1% 0V-1U1 on 100-120 mesh Gas Chrom Q (9) Gas flow - 120 ml/min N2 Column temperature - 220C Injector temperature - 230C ^ Detector temperature - 200c (2) 3% Dexsil 300 on 100-120 mesh Gas Chrom Q (9) Gas flow - 60 ml/min N.. Column temperature - 240C Injector temperature - 250c Detector temperature - 200C -- HONS 043370 i Porch lord,nati* n Procedure Tho sample to bo pcrchlorinated should be extracted and cleanod up by procedures (such as the FDA multi-residue pesticide procedure (10)) leaving tho residues in solvents that can be selectively evaporated from chloroform (6*i ethyl cther/petrolcum ether from Florisil or petroleum ether fraction from silicic acid). Transfer a 1 to 2 ml volume of cleaned up extract containing 1 to 20 yg PCB residue to a vacuum hydrolysis tube (a), (Cariari tube may be substituted). Add several drops chloroform, 1-2,20 mesh carborundum chips, and reduce volume to 0.1 ml by carefully heating tube in a steambath. Allow tube to cool to room temperature, add 2 ml chloroform, 1-2 carborundum chips, and reduce volume to 0.1 ml on a steambath. Repeat the addition of chloroform, concentrate to 0.1 ml, And cool to rocm. .temperature. Working in a wnl*. ventilated hood, earefully add 0.2 ml antimony pentachlc-id* to tube. Iiwedlately seal tube tightly to ensure a closed system reaction. (Note: it may be necessary to cool Teflon valves in ice before fitting into vacuum hydrolysis tube. The narrowed bottom of the valve should fit flush against the constriction in the glass when sealed. Carius tubes should be sealed in an oxygen flame). Immerse tube to a depth of 2 to 3 inches in an oil bath heated to 16S-175C and react overnight (about 15 hours). Remove tube from bath and cool to room temperature. In a hood, and while pointing the venting tide arm of vacuum hydrolysis tube away from face, open by slowly unscrewing the valve and pulling it out of the tube. (Corius^tube shoUld be scored with a file and snapped open in a hood at MONS 043371 5- arms length away from face; use extreme precaution since thore is r rapid releaso of prassure and sometimes splintered glass). Slowly add 1 ml 6N HC1 to reaction mixture, tap tube lightly to mix, and quantitatively transfer mixture to 30 ml separatory funnel rinsing with several small portions of HC1, using a total volume of 5 ml 6N HC1. (Motet it may bo necessary to rock tube back and forth or tap gently in order to drain). Rinse reaction tube with several small portions of hexane using a total volume of 15 ml hexane and quantitatively transfer rinsings to the 30 ml separatory funnel containing the HCl. Shake funnel vigorously for 1 minute; allow layers to separate. Drain the lower HCl layer into a second 30 ml separatory funnel containing 15 ml hexane, and shake one minute. Drain the KC1 layer into a third separatory funnel containing another 15 ml hexane and repeat extraction. Discard HCl layer and combine die three hexane extracts in a 125 ml separatory funnel. Wash hexane extract successively with two 20 ml portions HjC, one 20 ml volume 10% NaHC03 solution, followed by two additional 20 ml portions H2O. Discard all washes. Dry the waihed hexane extract by passing through a 2 inch column of anhydrous sodium sulfate and rinse column with 100 ml hexane, collecting hexane extract and rinse in a Kuderna-Danish concentrator. Add a few drops of methanol and concentrate on steambath to about 3 ml. Separate the volumetric receiver from concentrator, attach a micro-Snyder column to receiver and concentrate to a final volume of less than 0.5 ml to remove traces of chloroform. Dilute to a suitable definite volume for GLC determination, perform GLC determination and calculations as described under *Dlscussion." mqns 0433 -6- Discussion Derg,, Diosady and Rees' microscale perchlorination procedure vas evaluated to determine its utility as a routine laboratory procedure for confirmatory PCB quantitation. Parameters for quantitative extraction of DCB from the reaction mixture were not clearly defined by Derg and needed to be established prior to tasting the procedure for reproduci bility. Even after we developed a method of extraction that would recover over 95% of DCB standard from the reaction mixture, perchlorination using ' Berg's reaction conditions resulted in 90-100% conversion of Aroclor 1254 to DCB but only 30-70% conversion of Aroclor 1242. Conditions contributing to inconsistency in behavior between Aroclor 1242 and Aroclor 1254 needed to be determined and modifications made to achieve .conversion of ill PCB components in the various Aroclors to DCB. Perchlorination: The perehlorinat.'on procedure was designed fot use following extraction, cleanup, ancillary (separation), and detection procedures used in multipesticido residue methodology, in the Berg et. al. procedure, cleaned up extracts containing PCB were evaporated to dryness before reaction with antimony pentachloride. The observed non reproducible conversion of Aroclor 1242 to DCB with the original procedure is attributed to volatilization during evaporation to dryness of the lower molecular weight PCB components present in Aroclors with less than 54% chlorine substitution. To reduce the loss, evaporation is discontinued while a small amount of solvent (0.1 ml) still remains. I'owever, this limits the types of solvents which can be used since they may interfere during M0NS 043373 the perchlorination step. 2t was found that solvents with more than one carbon atom reacted with SbClcj exothermically to fora a solid black product. Chloroform as the solvent, however, minimised volatility, reacted favorably at the given conditions, and permitted selective evaporation of all solvents used in cleanup and separation procedures. Perchlorination is accomplished in a sealod reaction tube at elevated temperature and pressure. Increased pressure produced by the presence of chloroform vapors increased the hasards of handling the Carius tubes recommended for use by Berg et. al. In place of the Carius tube that required sealing in an oxygen flame and careful opening, a reaction tube with the same volume specifications, tight Teflon sealing valve, and verting side arm is recommended for use (see Figure 1). Parameters for extraction of DCB from the ronction mixture ware developed to completely recover (over 95%) DCB standard. Traces of chloroform present in the extract need to be removed before EC-GLC determination. This can be done by adding methanol, which forms en aseotrope with chloroform, and evaporating to a small volume before diluting. The resulting extract is sufficiently clean for electron capture GLC determination of DCB. In experiments designed to determine the feasibility of a shorter reaction time, iron was tested as a catalyst. One microgram Aroclor 1242 samples were reacted and extracted as described for overnight conditions except that two milligram iron powder were added after the addition of antimony pentachloride, the tube sealed, and the sample reacted for 4 hour and 6 hour periods. Results arc discussed under "Recoveries." HONS 043374 -e- By-products that would interfere with quantitative derivatizatio. vure not evident in our pcrchlorination experiments, however. Stalling (11) has found that a brominated by-product is formed when the antimony pantachloride is contaminated with bromine. Care should be taken to avoid use of contaminated SbCl^. GLC systems suggested for DCB determination are those originally developed for the detection of polychlorinated terphcnyls (9). At GLC conditions given under "Methodology", DCB elutes in 3-4 minutes on the * 1% 0V-101 column and in 12 minutes on the 3% Dexsil 300 column. These fast eluting systems produce increased GLC sensitivity to allow easy detection and quantitation of as little as 0.2 ng DCB. Quantitation: Altliough the perchlorination procedure can have practical applications in PCB quantitation, it is not meant to completely replace procedures normally used for this purpose. The analyst should still he aware of the Identity of the contaminating Aroclor(s), the presence ot other residues which could interfere, and any alteration in Aroclor pattern which may be duo to metabolism and/or environmental exposure. This information may be useful in tracing the source of contamination and may have toxicological significance. Some laboratories may wish to express residues in terms of parts per million DCB in order to establish a uniformity in their reporting. However, when the procedure is used for quantitative confirmation, DCB is expressed in terms of a specific Aroclor by using a factor for mathematical conversion. The factors used for converting DCB to the equivalent concentration of a HONS 043375 specific Aroclor arc derived by assuming the reaction to proceed as follows: Cl cl Cl Cl where n * number of chlorines is the approximate whole number of chlorines calculated from percent chlorine substitution for a specific Aroclor (see Table 1/. The approximate whole number of chlorines in a specific Aroclor was chosen for calculations, since Arodors are commercial preparations and the actual percent chlorine may vary from the theore tical for each lot. Hie factor for each Aroclor (See Table 1) is the ratio of amount Aroclor necessary to yield one unit of DCB: X ** factor for expressing DC?..as t. specific Aroclor molecular wt. Aroclor X " nnltcular wt. DCB (499) Calculations for measuring PCB residues by GLC based on the DCB derivative formed and converting mathematically to express the residue in terms of a specific Aroclor are: height sample ^ Nanograms of standard injected DCB peak hcxglit Std ' J Nanograms DCU in sample injection Nanogran Nanograms DCB in sample injection x factor for specific Aroclor (X) - Aroclcr sample i jection Nanograms Aroclor in sample injection wt. sample injected 'mg) - PPm Aroclor in sample HONS 043376 -10- Rccoverior.; To determine the percent conversion of specific Aroclora to DCB, A series of one microgram quantities of si>: different Aroclors wore reacted at the given overnight conditions and extracted ns described. The 3.% OV-101 column was used for the gas chromatographic determinations. Results are given in Table 2. The method demonstrated good reproducibility for quantitative conversion of the six Aroclors to DCB with results ranging from 87-105% and an average recovery of 97%. In the experiments with shorter reaction times, 10 trials with 4 hour * reactions using Aroclor 1242 gave a wide range of result:* although the average conversion to DCB was 90%. Trials with 6 hour reaction times gave results falling in a much narrower range and averaging 102% conversion. Results from these and experiments using the six Aroclors at 6 hour cpndj.t3.onn are .given .In Table 3. The prrchjorin ition in quantitative (99% average conversion for six Aroclors) and reproducible (range 83-110*) whun reacted for 6 hours with iron catylst but offers little advantage over the convenient overnight conditions. In order to determine the behavior of the perchlorination procedure In tlie presence of extracts of fatty samples, three gram samples of chicken fat and corn oil were extracted by FD/v multipcsticide residue methodology (10) . The 8% ethyl ether/petroleum ether fractions from Florisil cleanup were fortified with Aroclor 1242 at the 6.7 ppm level. Three aliquots of the cleaned up chicken fat each equivalent to 0.15 gram of fat and two samples of the cleaned up corn oil each equivalent to 3 grans were pcrchlorinatcd NQNS 0433?? -IX- *t overnight conditions with average recoveries of 107% find 96% respecti vely. These results show that the method can tolerate cleaned up extracts of up to 3 gram samples of fat and can handle 1 ug-20 pg quantities of PC'*. Application Samples of fresh chub, fresh sturgeon, and eggs environmentally contaminated with PCB, and chicken fat fortified with PCB were extracted and cleaned up by FDA multipesticide residue methodology (10). Where necessary, PCB were separated from pesticides by chromatography on silicic acid. The PCB residues were quantitated on electron capture CtC with a 10T- DC-200 column (10,12) by comparing the total area of the residue with total area of the Aroclor reference with most similar GLC pattern. Aliquots of the 6% ethyl ether/potzoleum ether Florisil eluate equivalent to 3 grams chicken fat, 0.2 grains sturgeon fat, and 0.2 grams egg were porchlorinated for qualitative and quantitative confirmation. The residue level reported for aach sample after perchlorination was determined by measuring the DCB derivative (1% 07-101 column) and mathematically converting it to tho equivalent amount of the Aroclor used as reference in the total area quantitation. Comparison of the residue levels obtained by the two determin; tivc procedures are presented in Table 4. Results obtained by the two methods of quantitation are in close agreement, demonstrating the practical application of the perchlorination procedure for quantitative confirmation. Gas chromatograms of an egg sample (Aroclor MGNS 0433 78 -12- 1242} quantitated for PCD as a multicomponent residue before perchlorination and as the DCD derivative after perchlorination at*o shown in Figure 2. Zn the case of the chub samples* the extracts containing residues of both PCD and DDT analogs were separated on silicic ucid prior to quantitation of tiie multicomponent PCB residues. Aliquots equivalent to 0.3 grams chub from the'silicic acid petroleum ether (PCB) fraction were perchlorinatcd and results compared (sea Table 4). Gas chromatograms of a chub sample quantitated for PCB (Aroclor 1254) s a multicomponent residue before perchlorination and as the DCD derivative after perchlorination are shown in Figure 3. Figures 2 and 3 also illustrate the increase in sensitivity obtained by perchlorination. For approximately equivalent peak heights on GLC only about 1/16 as much of the egg sample (Aroclor 1242) and l/)0ar rrtch of the chub sample (Aroclor 1254) were injected after perchlorination as was needed befere perchlorination. Organochlorinc pesticides, if present in a sample, should be separated from PCB prior to derivati7ing the residue to DCD. Pesticides such as DDT may be chlorinated to derivatives other than DCS. Preliminary studios show that perchlorination of DDT itself results in the formation of several derivatives which are separated from DCB on the 3% Dexsil 300 column at the specified conditions and do not interfere. Conclusions '* The perchlorination procedure developed for microscale qualitative and quantitative confirmation of PCB is routinely applicable to samples prepared for GLC residue analysis. It reinforces judgments made by the HONS 043379 13 analyst when dealing with a multicomponent residue. The derivut.tration procedure coupled C1C parameters used for chromatographing PCB also greatly incrcrseo tho sensitivity of PCB detection. HONS 043380 Bibliography (1) Pcokall, D. B. and Lincer, J. L., Bioscience 20, 958-964 (1970) (2) Reynolds, L. M., Residue Reviews 3, 25-57 (1970) (3) Risobrough, R. W., Rciche, P., and Olcott, II. S., Bull. Environ. Contain. Toxicol. 192-201 (1969) ' (4) Armour, J. A. and Burke, J. A., JAOAC 53, 761-768 (1970) (5) Aroclor Plasticizers, Technical Bulletin 0/PL306, Monsanto Co., St. Louis, Mo. (6) Armour, J. A., J. Chromatog., accepted for publication (7) Berg, 0. V/., Diosady, P. L., and Rees, G. A., Bull. Environ. Contain. Toxicol. 7, 338-347 (1972) (8) Hutzinger, O., Safe, S., and Zitko, V., Intern. J. Environ. Anal, them, (to be published Nov. 1372) (9) Wienckc, W. VI., U. S. Food and Drug Administration, private communi cation, January 1972 (10) Pesticide Analytical Manual, Vol. I, Food and Drug Administration, Washington, D. C., 1972 (11) Stalling, D. L., Bureau of Sports Fisheries and Wildlife, U. S. Department of the Interior, Columbia, Missouri, private communication, October 1972 (12) Official Methods of Analysis, 11th Ed., AOAC, Washington, D. C., 1970 HONS 043381 Table 1 Factors to Mathematically*/?onvert Dccachlorobiphcnyl to an Equivalent Amount ArocloiM Aroclor Average No. Cla MW*3 il 1221 i .IBB.5 0.38 1232 2 223 0.45 1342 3 257.5 0.52 1016 3 257.5 0.52 1248 4 292 0.59 1254 5 326.4 0.65 1260 6 361 0.72 1262 7 395.3 0.79 DCB 10 499 1 a Average whole number of chlorines calculated from percent ctlorine substitution for a specific Aroclor. b Molecular weight of Aroclor based on the average whole number of chlorines calculated from percent chlorine substitution. c X * molecular wt. Aroclor molecular wt. DCB (499) - . To convert ppm DCB to ppm of a specific Aroclor multiply ppm DCB by for the Aroclor. 043382 HONS Tabic 2. Percent Conversion of 1 lig PCD to Dccachlorobiphcnyl at Overnight Conditions. Aroclor 1242 1016 1248 1254 1260 1262 Trials 10 5 5 5 5 3 Range (1) 90-105 87-105 98-102 95-104 90-95 89-103 Average (t) 97 95 99 100 93 95 HONS 043383 Table 3. Percent Conversion of 1 yg PCB to Decachlorobiphenyl with Iron Catalyst and Six Hour Reaction Tine. Aroclor 1242* 1242 1016 1248 1254 1260 1262 Trials 10 10 3 3 3 3 3 Range (%) 78-98 96-110 87-95 95-100 98-106 91-108 83-107 Average (\) 90 102 92 98 103 98 98 *4 hour reaction. HONS 043384 Table 4. PCD Residua Levels in Environmentally Contaminated Samples Obtained by Two Different Methods, of Quantitation. Sample Reference Aroclor Chub 1254 Chub 1254 Chub 1254 Chub 1254 Sturgeon 1248 99 1242 'Chicken fat** `1242 Chicken fat*1 1248 PPM Residue by Total Area by DCB C Trial #1 Trial 1 3.5 4.2 3.4 4.2 4.2 5.1 3.4 28.4 7.1 4.5 28.6 6.8 28.4 7.1 4.6 5.0 6.9 6.6 a Residue is reported on a fat basis. b Samples fortified with Aroclor for an intorlaboratory study, c Expressed as reference Aroclor. MONS 043385 Figure 1. Vacuum hydrolysis tube recommended for sealed system reaction A. Dimensions 10 mm o.d. X 150 mn length. B. Tight Teflon ' . sealing valve. C. Venting side arm. MONS 0<*3386 IL MGNS 043387 [ Figure 2. GLC curves of egg samples 7.1 ppm PCB (as Aroclor 1242) before and after perchlorination. A. 1.11 mg sample (7.9 ng Aroclor 1242) 6% Florisil eluate before perchlorination, 10% DC 200 column (10,12). B. 0.07 mg sample (0.5 ng equivalent Aroclor 1242) 6% Florisil eluate after perchlorination, 1% OV-101 column. GLC conditions given under "Methodology". M0NS 043388 MONS 043389 Figure 3. GLC curves of chub sample calculated as 3.4 ppm PCD (as Aroclor 12S4) before pcrchlorination and calculated as 4.2 PCB (as Aroclor 1254) after perchlcrination. A. 1.5 mg sample ' (5.1 ng Aroclor 1254) petroleum ether eluate from silicic acid before perchlorination, 10% DC 200 column (10,12). D. 0.1S mg sample (0.63 ng equivalent Aroclor 1254) petroleum ether eluate from silicic acid after pcrchlorination, 1% OV-101 column. GLC conditions given under "Methodology." *3390 T 6 C C ^ 0 SNOW ATTACHMENT VI LABORATORY INFORMATION BULLETIN EDRO March 23, 1972 No. 91811 Pcatlcidcs Page 1 of 12 ADDITIONAL INFORMATION ON THE BEHAVIOR OF POLYCHLORINATED BIPHENYLS AND POLYCHLORINATED TERPHENYLS IN RESIDUE METllODOLOCY . *y ' Los Angeles District Buffalo District Division of Chemical Technology Interest has continued to grov In the analytical aspects of polychlorinated biphenyls and terphenyls (PCB/PCT). Emphasis on the identification and measurement of the residues themselves has surpassed the original concern of preventing their Interference in pestlilde residue analysis. Experimental Investigation and Industry contact has led to elucidation of composition of several Aroclor reference materials. In addition, a number of short term studies were done to determine the behavior of Aroclors in various analytical procedures, and tie responses of several GLC detectors to the chlorine content of Aroclors were compared. Experimental data presented here vere collected by: Herbert Masumoto and Milton Luke of Los Angeles District; Robert V. Hoffman of Buffalo District; Judith Armour, John Roach, Winfred Wiencke, and Susan Young of Division of Chemical Technology; and compiled by Bernadette McMahon of DCT. Aroclor 1232 Reference Material New information on the manufacturing process for Aroclor 1232 sheds lights on the reason for the differences among the chromatograms of several samples of 1232 obtained from Monsanto at different times. It has been revealed that when Aroclor 1232 was being manufactured for sale (It Is no longer available), It was made by coxbinlng amounts of Aroclors 1221 and 1242 until the mixture con.aincd 322 chlorine by weight. This Information explains how It is possible that the gas chromat03turns of some lots o[ Aroclor 1232 reference materials have resembled chromatograms of 1242, and others have more closely resembled chromatograms of 1221. - HONS 043392 March 23, 1972 Af-^HCHMENT VI No. 91811 Pesticides Page 2 of 1 It 18 probable that the manufactured lots of Aroclor 1232 varied in composition from one to another. For this reason, residues of Aroclor 1232 that may be found would be unlikely to match any arbitrarily chosen 1232 reference material. It is therefore recommended that residues suspected of being "Aroclor 1232", but resembling Aroclor 1221 and /or 1242, be quantitated by comparison to Aroclor 1221 and /or 1242 reference rather than by comparison to an Aroclor 1232 reference. From now on, Aroclor 1232 will not be considered a separate entity, and lists of data on the behavior of Aroclors In this LIB will not Include Aroclor 1232. Significance ? Little Aroclor 1232 was ever sold (according Monsanto) and none is available now, so residues of "1232" arc not likely. The suggested means of quantitation la available only in case such a residue la found. to Toxicological and ecological reasons for identifying the residue will not be jeopard.zed by reporting the residue as 1221 and/or 1242 rather than as 1232. Aroclors 4465, 5442. and 5460 Reference Materials By definition of the manufacturer, the Aroclors named in the tl.le are composed of mixtures of the following: 4465 - chlorinated biphenyls and terphenyls, with 65Z chlorine by weight 5442 " chlorinated terphenyls, with 42X chlorine by weight , 5460 - chlorinated terphenyls, with 60Z chlorine by weight . Chromatograms of each of the above mixtures were presented in LIB 918F. These chromatograms were- obtained at conditions normally used for the chromatography of the mixtures of chlorinated biphenyls. It has since been discovered that, at these conditions, the chlorinated terphenyls present in 4465, 5442, and 5460 were seen, at best, only as viry late eluting peaks. In turn, this failure of the chromatographic system to visualize the terphenyls led to some inaccurate results In other experiments which used GLC as a determinative otep. kcccnt investigations iron several sources .have revealed new information about the Aroclors in question. In part, the evidence has been obtained by use of a GLC column which permits terphenyls to elute quickly enough t q be easily seen and measured (MB 918 C) . MONS 043393 ATTACHMENT VI .<rrh 23, 1972 Ho. 91811 Pesticides Pag* 3 of 12 Hew finding* on the Aroclors of Interest follow. - 44 65; The reference material distributed to FDA Districts by the former Reference Standards Branch appears to be mostly biphenyl compounds, despite Monsanto^s description of this mixture as 40:60 terphcnyl: biphenyl. Chromatography of 4465 on a CLC column which permits visualization of terphenyls docs not reveal the presence of additional significant compounds. Because the 4465 reference material obtained from Monsanto by FDA does not match Monsanto's description of the product, It Is suspected that the terphenyl: biphenyl proportion must vary among different manufactured lots. The description of the material as a combination of terphenyl and biphenyl also suggests that 4465 may have been made by combining amounts of other Aroclors until 65Z chlorination was obtained. Therefore, it may be possible to handle residues of "4465" by comparing them to other Aroclor references which they resemble. Monsanto no longer manufactures Aroclor 4465, so no additional samples of reference material are available. For this reason, data presented In other sections of this LIB were obtained using the reference material containing mostly chlorobiphenyls. 5442; The reference material of 5442 available In FDA contains some coktamlnation with chlorinated biphenyls, as evidenced by the early eluting peaks In the chromatograms In LIB 918F. The contamination Is relatively small, and the data for 5442 presented elsewhere In this LIB were obtained by measut lng the recovery of the tarphanv 1 s with a CLC column which permits the terphenyls to elute quickly. 5460: The 5460 distributed as .> reference material has now been shown to contain a relatively large (about 5%) contamination of chlorinated biphenyls. It is now apparent that only the biphenyl contaminant was being visualized by the CLC systems used In LIB 918F, which explains why the chromato)rams of 5460 resembled 1260 so closely. The chlorinated terphcnyl components of 5460 can be seen and measured when the alternate CLC column is used. Data on the behavior of 5460 presented elsewhere In this LIB were obtained using the alternate column to visualize the terphenyl components of 5460 for measurement. Significance: Residues of chlorinated terphenyls are presumably . of as much Interest and Importance as those of chlorinated biphenyls. Until recently, the capability for detecting and measuring chloroterphenyl residues was limited by the very long retention times and consequent poor sensitivity for the compounds on the CLC columns (PAM 311,. 2) normally used for analysis of chlorinated biphenyls. . The chlorinated terphenyls are recovered, at least partially, through the analytical procedures used for organoch1 orino pesticides and PCB (see oLhc-r sections of this I IB for details). it is now possible, by means of the CLC column described by Wlencko (LIB 918G), to visualize residues of chlorinated terphenyls and to estimate their quantity against a known amount jpt ' MOWS 043394 (lurch 23, 19 7 2 n* iiH4u No 91811 Pesticides Page 4 of 12 reference material. Thin Is the recommended procedure for detection and measurement of residues In samples suspected of contamination with chlorinated terphenyls. In particular, samples whose preliminary CI.C analysis shows peaks eluting beyond the retention times of chloiinated biphenyls should bo Injected on the 'alternate column to visualize any terphenyls present. Chloroterphenyl residues too low to be recognized In ordinary sample examination can be discovered by injections of the sample on the alternate column. Variations In Partitioning Among PCB/PCT It has been determined that the efficiency of transfer of PCB from petr ether to acetonitrile decreases with increasing chlorination of the compounds. In particular, thefollowing recoveries of Aroclor Standards were obtained when a known amount of each Aroclor In IS ml petr ether was partitioned into four successive 30 ml portions acetonitrile, each acetonitrile portion being backwashed with an additional 15 ml petr ether (PAM lv 211.14b): Aroclor us in 15 ml PE X recovery 1221 1242 40 40 94 97 1248 40 93 1254 40 87 1260 40 7l> 1262 40 74 4465 20 71 Among the PCB components of any given Aroclor, those whose peaks eluted first in the normal gas chromatographic system showed the highest recoveries. Percentage recovery decreased with increasing retention times (which generally Increases with Increasing chlorination), again suggesting that the more highly chlorinated the Isomer, the poorer its transfer from petr ether to acetonitrile. The two Aroclors made up of polychlorinated terphenyls (PCT) display a similar pattern. When Aroclors 5442 and 5460 were partitioned as described above, 92 and 772 of the original 20 ug were recovered, respectively. Recoveries of individual PCT in the Aroclors were not determined, because the GLC column for PCT does not rer.olve the components well enough for measurement of each. 81enlflcance: The experiments performed in gathering this recovery data were designed to duplicate the partitioning step most often used in the analysis of fatty foods for MONS 043395 1 March 23, 1972 A`mtU>rtiu VI No. 91611 Pesticides Page 5 of 12 orgnnochlorinc pesticides and/or PCD. The residue analyst should be awArc that recovery through PAM I method 211 (fatty foods) will be different for different Aroclors and should avoid attributing losses completely to the Florlsil or silicic acid column chromatographic steps* In addition, the pattern of PCB Isomers in a given Aroclor Is altered to some degree by this phenomenons, and may cause confusion to the Inexperienced ' analyst. P.ecoverv of Aroclors Through Florlsil Column Chromatography New Information on the behavior of Aroclors in other parts of the methodology has prompted reassessment of the elution of Aroclors from the Florlsil column (PAM 211.14d). Frequent use of pesticide residue methodology for the analysis for PCB has assured us that the chlorinated biphenyls elute in the 62 ethyl ether/petroleum ether eluate. Additional experiments have shown that Aroclors 4465, 5442, and 5460 are also eluted by the 6% eluant. Recovery of Aroclors Through Silicic Acid Column Chromatography Mssumoto (In press, JAOAC) has pointed out that some of the chlorobiphenyi isomers present in Aroclors are not .tluted from the silicic acid column by petroleum ether as originally reported. Instead, the chlorobiphenyi isomers with early CLC retention times (which, generally, are those with lowest chlorination) are likely to be held on the silicic acid column and eluted from it only by the second, folar eluant. Aroclors consisting mostly of lower chlorobiphenyi isomerc vlll therefore show low recoveries in the petroleum ether eluate. Recoveries of PCO in the following Aroclors were obtilned from a column made of silicic acid and Ccllte (LIB 918C-E) which had been previously standardized by addition of enough H2O to affect separation of pp'DDE and Aroclor 1254: Aroclor 1221 ' Recovery essentially all in polar eluate 1242 20~35% In polar eluate 1248 lefts than 20Z In polar eluate 1254 completely in petroleum ether 1260 completely Jn petroleum ether 1262 completely in petroleum ether M65* completely in petroleum ether MONS 043396 March 23, 1972 No. 91811 Pesticide* Page 6 of ^Reference material contained mostly polychlorinated biphenyl isomers, rather than both biphenyl and terphenyl isomers. The silicic acid column chromatography of the two Aroclors consisting of PCX was also examined . All of the Aroclor 5442 and most of the Aroclor 5460 added to s silicic aeld column was eluted by the polar eluant . Aroclor 5460 'was partially eluted by the petroleum ether eluant. Significance: Knowledge of the elution characteristics of the Aroclors from the silicic acid column will aid the analyst in his choice of the appropriate analytical treat ment of samples containing both pesticides and PCB. If exam ination of the original GLC chromatogram shows the PCB to resemble an Aroclor known to be incompletely separated from pesticides by silicic acid, alternate treatment(s) can be chosen to permit quantitation of the residues. Response of C1C Detectors to the Chlorine Content in Aroclors Experiments were performed to determine whether the responses of the electron capture, microcoulometric and electrolytic conductivity detectors were proportional to the ihlorine content of Aroclors regardless of the nature of I he compounds comprising the Aroclor. Results indicate that the response of the halogen specific uicrocoulotnetric and electrolytic conductivity detectors to the same amount of chlorine in different Aroclors was essentially the same. In :ontrast, the response of the electron capture detector to the more highly chlorinated Aroclors was disproportionately high when compared to the response of the same detector to Aroclors with lower chlorine content. * The electron capture detector that was used was first shown to give reproducible results and to be linear in response to amounts of heptachlor epoxide injected. Then, injections of six Aroclors were made and the total area of response measured for each. Calculations were performed so that responses to the different Aroclors could be compared to one another, on the basis cf response/weight chlorine. The following ratios were obtained in this way: Aroclor 1221 Relative Response/Weight Chlorine 1 1242 3.02 1248 J' 4.56 HONS 043397 March 23, 1972 ATTACHMENT VI I No. 916)1 Pesticides Page 7 of 12 1254 9.64 1260 12.70 1262 10.35 It la obvious from these data that response of the EC detector la not proportional to the amount of chlorine present In the chlorobiphenyl molecule. In contrast, the response of the mlcrocoulometrlc detector to Injections of the same amounts of chlorine in each of four different Aroclors was essentially the same for each Aroclor. Because detector sensitivity Changed with time, ratios of response to Aroclor X are compared; the injection of Aroclor frfeiponse to Aroclor 1242 1242 and the injection of the other Aroclor were always made within ap hour of one another. Other special precautions were also utilized to Improve reproducibility; e.g., the first two Injections made after cell flushing and equilibration were not considered. The following ratios ve*e obtained: Relative Response (for acme weight chlorine) i Aroclor Meat Ranee (number of inlectionO 1242 1248 1254 1.00 0.97 1.00 (used as standard) 0.90-1.03 (3) 0.92-1.23 (5) 1262 1.10 . 0.86-1.26 (6) Despite the problems encountered in dealing with the microcouloelrlc system, these data do present evidence that microcouloatric response is essentially proportional to the amount of chlorine present, regardless of the structure of the compounds. Figures 1-5 demonstrate visually the contrast between EC and mlcrocoulometrlc responses to chlorine content In the ?CB contained in Aroclors. In particular, the lower chlorinated Aroclors and the early eluting (lower chlorinated) PCR within the Aroclors sluw the none marked difference in pattern between K C .and nticrocoulo metric respond cm. l'his ctccct is consistent with the data on EC and microcoulomctrlc responses presented above. Note that the amounts of each Aroclor injected HONS 0 * 3 3 9 8 March 23, 1972 ATTACHMENT VI No. 91811 Pesticides Page *8 of 12 ary and Chat no accev.pt has been made to compare instrument sensitivity in these enromatograms. The electrolytic condjetivity detector was also shown to respond to the chlorine content of PCB in a study using a Coulson . electrolytic conductivity detector specific for halogens. The system was operated in the reductive mode and utilized a platinum catalyst. Two injections each of Aroclor 1221 through 1260 were made and compared to the response of Aroclor 1242 which was used as a reference. The reference was injected immediately prior to the Aroclor being checked in each ease. Aroclor 1242 was also used as a means of checking the sensitivity of the detector which varied from day to day and even during the course of a day's operation. For these calculations the response for Aroclor 1242 and the Aroclor being checked were measured by planimeter in square Inches. In this regard it was noted that the linearity for this detector appeared to drop off sharply when the response fall below 0.09 ln.^/ng chlorine, which was due prlnarily to the Inability to accurately measure all the peaks in the reference or Aroclor being tested. Results were as follows: ^ Aro.clor ng Injected Response in ^/ng Cl Respot e to Aroclor Response to Aroclor 1242 1221 1221 1242 125 112.5 U..8 0.12 0.12 a. Reference 1.01 1.00 1.00 1248 1248 1254 1254 1260 115 125 125 100 125 0.09 0.09 0.10 0.10 0.09 1.05 0.99 . 1.01 0.99 1.02 1260 150 0.09 1.08 Significance. The use of Aroclors as reference materials for the quantitation of PCB residues involves inherent problems ber.uu.tr the- residue Is :;oe: often :3...ruJ in composition from the original Aroclor. Alteration can occur in several ways; e.g. weathering *d/or metabolism, preferootial .storage of certain components In atimals, variations Jn-recovcry of conpon-.nrs through the methodology (described in this L1H), and variation in HONS 043399 March 23, 1972 No. 91DH Pesticides Page 9 the amount of loss through volatilisation of the different edmponents '(to be described in a forthcoming report from LOStDO). The accuracy of the quantitative result decreases with the increasing alteration of the PCB residue from Che pattern of the Aroclo; reference. The disproportionate response of the EC detector to the more highly chlorinated components aggravates the problem of quantitation of an altered residue. The analyst should be aware of these limitations and, If possible, quantitate altered residues using one of the halogen-specific detoctors and reference Aroclor(s) whose pattern matches that of the residue most closely. This should minimize the problem until such time when an Improved method of quantitation is available. MQNS 043400 March 23, 1972 EC s 44n| Ho. 91811 Pesticides Page 10 of 12 Pig 1 ..Aroclor 1221 t MONS 043401 aaJW/nMJ Fig. ;3 EC I 26 ng I Fcticl<l':s Fnge 3. 1 o f 12 Aroclor 124B r Fig. 6 Aroclor 1254 HQNS 043402 Xe. 9iSH Pesticides Pas: 12 of 12 ATIAC8MEKT VX Kerch 23* 1972 Fig. 5 Aroclor 1260 EC : 20 ng HONS 0 4 3 4 0 3 Instrument Conditions : Figures 1 - 5 r.C : :72 DC 200 col, PAM I 311.2 Paraneters; 70V; 1 x 10-9 afs ;:C ' l PC 2 O'J col. at 200*C, 120 el/min X2? Injector tenp 225*C; 'o'*!!! specific detector, 100A. R-i?* 95.