Document ppZonnYX2pv1djqD7D30rmN87
March 23, 1992
Dow U.S.A.
The Dow Chemical Company P 0, Box ISO
Plaquemme, Louisiana 70765-0150
Daniel Cortez Eddie Guillory
Petrin Petrin
Building 4106
cc: Billy Hood
Chlorine Building 2601
Asbestos_Monitoring
Enclosed are sample results for potential exposure to asbestos.
The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 1/cc >5 microns.
The results displayed are based on sampling duration.
The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation.
Thank you,
Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E
Attachment dsc
DO A 11.4977 CONFIDENTIAL
PRQQUCSD 1*0* THE asbestos database
fVATK. 3 a
-----------------
MASTER No.
...
ASBE
MQNTIQBIMG.DATA RESULTS: Chlorine 1982
**LOD ***LOQ
EXPOSURE GUIDELINES 8-HR. TWA LIMIT - 0.20 FiB/CC 30-MINUTE UMIT = 1.0 FIBJCC UMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2
DATE SAMPLE* PERSONNEL DESCRIPTION
3/9/92
13921
"435-06-2532 Insulator: Removing asbestos insulation from 6" line WET METHOD USED
DUR(M1N) 30
YQUU
75
LOD
Fia/cc
<0.01
***LOQ FJB/CC
<0.51
* The proper protective clothing was worn during the job. North 7700 Respirator with HEPA filters were worn during the job.
Note: Th Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method Is 100 to 1300 Flbers/MM2 fitter area Although samples below this range can be analyzed, the method has not been validated below 100 Flbers/MM2. However, th NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Flbers/MM2 (Reference OSHA Sid. 1910.1001, Appendix B). Based on this Information, we will establish 100 Flbers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which Is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection.
If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute.
DO A 1.14970 CONFIDENTIAL
LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD
PLANT/DEPT.
C. hfar,is*- / pQtO____________________
DATE 3 ~
MONITORING FOR:
Ph
ZT. b tsS
OTHER CHEMICALS PRESENT:
SAMPLE NS 13921
SAMPLE COLLECTION MEDIA:
O BADGE NO. TYPE_____________________
TEMP/HUMIDITY: (REQUIRED FOR BADGES).
CHARCOAL TUBE SIZE_________________
(Filter cassette size ? r fnrr?
SILICA TUBE
SIZE_________________
DRAGERTUBE TYPE_________________
OTHER _________________________________
SHIFT: 3"8 HR. O 12 HR.
'ERSONNEL SAMPLE AREA SAMPLE
FULL SHIFT TWA STEL/TASK
EMPLOYEE NAME___ EMPLOYEE I D.#____ JOB CLASSIFICATION IIHfl JJOUDB CV.OwDl/1E. #IF CONTRACTOR COMPANY
r ^_____C_______
i/t/S u<o UO.
RESPIRATOR USED? O^ES O NO
/,
RESPIRATOR MODEL / CANISTER TYPE NU* -Hi l/OQ Wf h pG
MOUTH-BIT
DUST
0 HALF-FACE
~
FULL-FACE
AIRLINE SCBA
DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING .
PUMP SERIAL NO. 5T/-
CALIBRATION DEVICE: &BUBBLEMETER
ROTAMETER
OTHER_____________________________
PUMP FLOW RATE CALIBRATION:
BEGIN: 1. 3 HY-l
2- ait_T____
3.
BEGINNING FLOW RATE AVG. J- V 7% PT^CC/MIN L/MIN
ENDING:!.
rO->
2.
3._ cWni hf ENDING FLOW RATE AVG. a
O^C/MIN L/MIN
SAMPLE AVERAGE FLOW RATE
^93
TIME STARTED
'$0 ____________
TIME STOPPED
70. flip 7tm
TOT. RUNNING TIMEfMINl '*>/) /fon ~
SAMPLE VOLUME (AVG FLOW X RUN TIME) ~\S"
%
If' jL*j -
ANALYTICAL REPORT REFERENCE #, __
ANALYTICAL RESULTS:
i'WJ
RESTRICTED FOR USE WITHIN DOW ONLY *
VP-124
r
s\
FORM FILLED IN BY: _
*1
IJf O M 1 1 4 ` V / "J1 CONFIDENTIAL