Boilers, Gas
B-Line, Boiler Company
Cleveland, Ohio
Manufacturers of Gas Boilers for Hot Water, Steam and Vapor Heating; Hot Water Generators; Auto
matic Controls for Gas Heating Appliances..
Model "AT* steam Boiler
Boiler No.
Btu Output per Hour
22 23 24 25 26 27
43 54 65
76 87 98 109 1110
12)1 1312 1413 1514 1615
1716 1918 2019 2120
2322 2524 2726 2928 3130
3332 3534 3736 3938 4140
38,400 76,800 115,200 153,600 192,000 230,400
158,400 211,200 264,000
316,800 369,600 422,400 475,200 528,000
580,800 633,600 686,400 739,200 792,000
844,800 950,400 . 1,003,200 1,056,000
1,161,600 1,267,200 1,372,800 1,478,400 1,584,000
1,689,600 1,795,200 1,900,800 2,006,400 2,1(2,000
B-Line Gas-Fired Boilers are built for use in connec tion with Steam, Vapor or Hot Water systems of heating; Industrial Steam Supply Units, and Volume Water Heating Units.
B-Line Boilers are constructed of cast-iron section^ assembled with cast-iron push nipples. The heat absorbing surface is unusually large and arranged so as to transmit! practically all available heat into the water.
B-LINE BOILER RATINGS
Boiler Hp.
A. G. A. Rating
Steam
Water
Model "M" Boilers
II
2.3 3.4 4.6 5.7 . 6.9
160
320 480 640
800 960
260
510 770 1020
1280 1540
Models
n
6.3 7.9
9.5 11.0 12.6 14.2 15.8
17.3 18.9 20.5 22.1 23.6
25.2 28.4 30.0 31.5
34.7 37.8 41.0 44.1 47.3
50.4 53.6 56.7 59.9 63 0
`K'* and "DK * Boilers
660 1060 880 1410 1100 1760
1320
i 1540 1760 1980
2200
2110 2460 2820
3170 3520
2420 2640
2860 3080
3300
3870
4220 4580 4930
5280
3520 3960
4180 4400
5630 6340 6690
7040
4840
5280 5720 6160
6600'
7740 8450
9150 9860
10560
7040 7480
7920 8360
8800
11260
11970 12670 13380
14080
.
Radiation Load
Steam
Water
105 165 210 325 310 495
415 655 520 620 630 1010 *
425 575 730
885 1040 1195 1350 1505
1660 18)5 1970 2130 2295
2455 2780 2950 3110
3440 3770 4090 4400 4710
5030 5340 5660 5970 6290
680
920 1170
1420
1665 1915 2160 2410
2660
2905 3155
3410 3675
<
3930 4450
4720 4980
5505 6035 6545
7040 7540
>
8050
8545 9060
9555 10065
B-Line Boiler control system is entirely automatic in operation, or semi-automatic, if desired. The controls are mechanical, gas operated type, consisting of a hand control valve; gas pressure regulator; snap action fuel control valve to cut on or off, the fuel supply at a predetermined steam pressure or .water temperature. Automatic low water fuel cut-off is furnished for steam boilers. Thermostatic pilots are optional. Automatic secondary air control which cuts off the air supply to the combustion chamber when the fire is extinguished, thus eliminating rapid cooling of the boiler sections is furnished on Model "K" Boilers only.
B-Line Boilers tested, and approved for all sizes by A. G. A.
Model " K " Water Boiler
612
Boilers, Gas
L. J. Mueller Furnace Go.
Established 1857
338 So. Second St., Milwaukee, Wis.
. Gas-Era Gas-Fired Boilers
Adaptable for steam or hot water heating. Completely automatic operation. Cast iron construction for durability, with asbestoslined metallic jacket. Vertical burner adjustment permits use with any manufactured or natural gas. Have steady water line
and will not prime. Interior surfaces may be thoroughly cleaned without disturbing jacket. Multiple unit con struction permits increase in size when desired. Boiler is highly efficient, securing maximum heat utilization with minimum gas consumption.
HOT WATER
A.G.A. Rating
13-W 24-W
25-W 37-W
49-W 511-W
613-W 715-W 817-W
919-W 1021-W II23-W 1225-W
1327-W 1429-W
I53I-W 1634-W 1838-W 2042-W 2246-W
2450-W 2654-W
2858-W 3062-W
670 1,005 1,340
2,010 2.680
3,350 4,020. 4,690
5,360 6,030
. 6,700 7,370 8,040 8,710
9,380 10,050
10,720 12,060 13,400
14,740 16,080
17,420 18,760 20,100
STEAM
A.G.A. No. Rating
13-S
24-S 25-S 37-S 49-S
511-S 613-S
715--S 817-S 919-S
1021--S 123--S 1225-S
1327-S 1429-S
1531--S 1634-S 1838-S 2042-S
2246-S 2450-S
. 2654-S 2858-S
3062-S
420 630
840 1,260 1,680 2,100
2,520 2,940
3,360 3,780 4,200
4,620 5,040
5,460 5,680
6,300 6,720
7,560 8,400 9,240
10,080 10,920
11,760
12,600
Floor Space Inches
31ft x 46*4 35ftx 46ft 39 x 47ft 46V4x 51ft
Sft
70 x 51 ft 79ft x 53ft 87ft x 53ft 95ft x 54ft 103 x 54ft 110ft x 56ft -1-2-C-P-/-2 x 5533Vf.t 1281/4 x 543/4 136 x 54ft U3ft x 543/4. 871/z 1071/, 95ft x 109ft 103 x 109ft 1103/4 x 112ft 1201/2 x 1071/4 128ft x 109ft 136 x 109ft 1433/4 x 109ft
VENTS
Diameter Inches
14 16 17 19 1 10
11 29 2 10 2 10 2 11 2 11 2 12 3 10 3 11 3 11 3 II 2 14 2 16 2 16 2 17 3 14 3 16 3 16 3 16
Size Gas Connection
Required
1 1
I'A Wi 2 2
m i'h lYz i'h wi m 2Vi 3 3 3 3 3 4 4 4 4 5 5
Gas-Era Gas-Fired Warm Air Furnace
Cast iron construction, with green lacquered casing. Completely automatic. Accessible for cleaning. Auto matic moisture supply. Adaptable for forced air heating.
Furnace No.
A.G.A.
Input Rating B.t.u. per Hour
Total Load B.t.u. per Hour
Capacity Warm Air Pipes
Sq. In.
1 (10)* 2(20) 3(30)
4(40) 5(50)
6(60) 7(70)
8(80) 9(90)
X-IO(IOO)
65,000 130,000
195,000
260,000 325,000 390,000
455,000
520,000 585,000
650.000
47,500 95,000 142,500 190,000 237,500
285,000 332,500 380,000 427,500 475,000
430
860 1290
1720 2150
2580
3010 3440
3870 4300
uauic 1UUUKC, two
oijuipun,u. "Civ.
------- --
--- ,
Write for eafalnga on above unite, also on Gas Era Steel Furnaces and.Ciimator
Air Conditioning Systems,, complete with blowers, humidifiers, filters, washers
and cooling equipment.-
Gas Era Furnace
Gas-Era Furnaces and Boilers tested and approved for all sizes by American Gas Association