Document pp7r2M3Q1Rop5E71E8BMeVwr6

232 CHAPTER ,10 1958, Guide Housing and Home Finance Agency for the guidance of owners;, builders, and architects.14 The dotted lines are the 20.F, 0 F, and +20 F isotherms of winter design temperature taken from Fig. 1, Chapter 12. It will, be noted that there is reasonably good correlation between the zones deter mined by the two sets of lines. Zone I roughly,includes those areas where the design temperature is--20 F.or colder; zone. II those for which the design,temperature is zero to --20 F, and :zone.III those at zero and warmer. Within each zone, similar degrees of condensation trouble are to be expected; and similar corrective measures apply. ' In roofs, the condensation problem is much the same as in walls. The roof covering may be even more resistant to the escape of vapor than wall Fig. 6. Condensation Zones in the United States 1: Zones Include Areas with Design Temperatures about as follows: Zone I, --20 F and lower: Zone Hi O F to -- 20 F; and Zone III, above 0 F. Note 'that cross hatched areas are outside of Zones I and HI.) tf;r coverings such as paint; and while paint is likely to be ruptured by ex$|? sive moisture, no such relief. occurs in roofs. Thus roofs furnish con spicuous examples of rapid decay in. lumber. :j(i . In crawl spaces over uncovered damp ground, a large water evaporation' sometimes occurs and causes condensation on the outer ends of floor joists and other members that are below the floor line and near to the outside.. Water vapor from the crawl space may also enter walls, be transported ,,hy; rising air in a stack effect, and even reach the attic by this route when.the ;wall structure permits. Ventilation, as discussed later in this chapter,iE an important correction.factor in these cases. ' Insulation in a wall or roof reduces heat loss and lowers the temperature of the outer elements of the structure; thus, increasing the possibilityi0i condensation if :the vapor path to the cold surface is not blocked. Sine?, low vapor resistance is a characteristic . of fibrous insulation, the needed; vapor resistance must be provided by other means. It is to be noted that: Moisture in Building Construction 233 in typical residential conditions, condensation does not; occur in- fibrous insulation itself, except when frost has formed on sheathing and gradually built backward among the fibers. Wet insulation may result from this condition or from liquid condensation seeping down from a higher level. CONTROL OF CONCEALED CONDENSATION An excessive accumulation of moisture in walls (or roofs) can: be pre vented by one or more of the following measures: (1) provide a vapor bar rier to limit vapor entrance into the wall, (2) ventilate the building to reduce vapor pressure therein, (3) ventilate the wall cavity to remove vapor that has entered.. 1. Vapor Barrier. A vapor barrier is the principal and most obvious correction, but each measure is more effective if aided by the effect of another. In habitations, some ^ventilation of the living space, either inci dental or planned, is necessary. ' Also, a small amount of cavity ventilation is essential in cases where the vapor inflow is not completely stopped and the moisture storing capacity of the outer wall elements is slight. This applies to some prefabricated designs using metal siding. Vapor barrier sheets are often built into the wall hear the warm surface. In wood frame walls they may be applied to the inside surface of the studs. They are sometimes attached to the warm side of the insulating materials, or they may be applied on the cold side of plaster base materials. Special designs may be attached like wall paper to the inside of the wall, when satisfactory from the decorative view point. Sheet barriers often contain asphalt as the vapor resisting ingredient; metal foils, so placed that they are not too cold, may also be used. The interior wall board or finish material may itself be vapor resistant, or a barrier coating may be applied to its concealed side when that side will not be too cold. The interior finished surface may be coated with a suit able paint having the required vapor resistance and. also serving as the decorative finish, or it may be covered by another coat. A paint coat on the interior finish, though of adequate resistance, is not likely to be so effective as a sheet barrier properly applied during the wall construction. This applies especially to houses- of more than one story having cavities in ceilings which open into the outside walls. Such cavities allow vapor entering the ceiling to diffuse or be transported to the cold aJaa- ^.PPa8e f this path is difficult, requiring normally'the painting of the ceiling as well as the walls. Similar treatment may be required on internal partitions, or. at least the first stud space adjacent-to the cold wall. necessary barrier resistance depends on a number.of factors.; When tne vapor flow occurs in annual cycles as in heated buildings, the require ment is not so exacting as it is for a cold storage room where there is no cnance for drying out an accumulation of moisture. In a heated structure overed on the outside with materials highly resistant to water vapor such in th*11* ,r/U roonS) the winter season is a time of moisture accumulation ini h- co c\.outer elements and their safe moisture holding capacity is an she^tiv*' *ac^?r 111 determining the barrier requirement. A house without shet r reQuires a better barrier; and a prefabricated design with only a ,'p. . f metal outside of insulation requires very high barrier resistance, also Ulterior vaPor pressure and the length and severity- of the winter are 'era'll ^rame dwellings with wood sheathing and siding in the north- mted States, a barrier permeance of one perm or less has been found