Document pp6e98mrMEow84r5zyjL8Y0eD

6. Whenepace permits, all scaffold platforms must be equipped with standard 42-inch high handrails*, rigidly secured and completely decked with safety plank or manufactured spaffold decking. 7. Use rigidly-secured toeboards where area below is unrestricted to personnel. 8. Scaffolds, under which personnel are required to pass, shall be provided with 'A inch mesh #18 guage wire screen between toeboard and rail. 9. Adjusting or leveling screws shall not be used on scaffolds equipped with wheels. Adjusting screws, where permitted, shall not be extended more than 12 inches of thread. 10. Never exceed safe working loads on scaffolds. 11. Rolling scaffolds shall be used only on smooth, level surfaces, or the wheels must be contained in wooden or channel iron runners that are level and stabilized. Check overhead clearances before moving. 12. No alteration is permitted to any scaffold member by welding, burning, cutting, drilling, or bending. 13. Brick, tile, or similar material may not be stacked higher than 24 inches on a scaffold deck. 14. Never rig from scaffold handrails or braces. 15. Generally, parts and sections of patented metal scaffolding of different manufacturers are not interchangeable. 16. Swinging stages, toothpicks, boatswain ("bos n") chairs, floats, and needle beams must be approved by the Du Pont Administrator and inspected by a Qualified Person before use. Safety belts must be secured before wearers step onto scaffold, and they must not be removed until men are clear of the scaffold. Belts must be tied off to independent lifelines or building struc ture ... one lifeline per man. 17. Scaffold (or safety) planks should not be used tor skids, ramps, runways, workbenches, or purposes other than scaffold decking. 12 18. Before moving special scaffold materials lothesite for uses other than above, determine the restric tions from the Du Pont Administrator E. Barricades 1. Required around excavations, holes, or openings in floors or roofs, elevated platforms, around certain types of overhead work, and wherever necessary to wam people against falling. 2. Must be 42 inches high, square, and level. 3. Keep six feet back from the edge of excavations, holes, platforms, and roofs unless a protective bar ricade is used. 4. Erect before the hole is cut and extend as the excavation progresses. 5. Remove when no longer needed. 6. Numerous excavations in one area may be bar ricaded effectively by erecting a barricade around the general area. 7. Blinking lights must be used on road blocks after dark. 8. An access opening or gate should be provided where practical. P. Hole Protection 1. All holes or openings through floors, decking or walls less than 3 feet above floor at all elevations must have properly-identified hole covers or bar ricades immediately. Matenal or equipment (bust never be stored on a hole cover. 2. Covers must be secured so they cannot slip, and extend adequately beyond the edge of the hole. 3. Covers may be fabricated from v inch plywood, provided one dimension of the openmg is less than 18 inches: otherwise. 2 inch lumber is required. Signs Legible signs should be placed on barricade stands, posts, or other suitable stanchions before work starts, and be removed promptly upon completion. Material Hoists 1. To be operated only by Authorized Operator 2. Are not to be used for personnel. \ 13 J DUP 09109M