Document pp0YY3DbDZdn43n1rj5GOJa7B
Industrial Noise
has stimulated an interest m automatic audiometry, which allows the subject to operate the only manual control of the test instrument required during the test When the test is started the intensity of the signal tone increases automatically The subject has been instructed to press a button when he first hears the signal This button operates a switch which reverses the direction of the signal intensity, thus decreasing the signal strength When the subject no longer hears the signal he releases the button and the sig nal again increases in intensity The pro cedure is continued for a set interval dunng which the subject may "cross" his own thresh old as many as ten or fifteen times When the proper time has elapsed the audiometer output automatically shifts to the next fre quency and the procedure is repeated The test continues until an arbitrarily chosen number of frequencies has been tested
A record of the test may be made with any of several devices which record the continu ous change m output level of the signal as it crosses and recrosses the subject's threshold level Automatic audiometers have been variously adapted to record the test on specially designed cards, on IBM cards, by automatic typewriter, or by an adding ma chine In principle all automatic audiometers are much the same the intensity of the out put signal is regulated through a switch which is controlled by the subject Its va lidity has been well established
The usefulness of automatic audiometry depends upon the conditions under which it is to be used As far as the subject is con cerned, automatic audiometry does not save time as most automatic instruments run for six to ten minutes to complete a test, about the time required to complete a test with a manual instrument As far as the tester is concerned, however, the instrument makes audiometry less tedious and it does save a significant amount of time When large num bers of audiograms must be made, two, three, or perhaps four automatic audiometers can be operated by one technician who has only to load and start each instrument, the rest of the test being completed automatically It is possible for one technician to keep several instruments m continuous operation
Automatic audiometry has been very suc cessfully used in several large industrial
plants It is not, however, a general solution to the problem of hearing tests in industry Its success depends strictly upon the exist ence of the proper conditions, and before a decision is made to install automatic audi ometers several things should be considered Perhaps the principal consideration is the higher cost of the instrument If seveial automatic audiometers can be used at one time, the most efficient use of the technician's time may compensate for the excessive cost If tests are to be made with several automatic audiometers, a test booth is required for each instrument because tests cannot be performed m groups except with special equipment
Automatic audiometers do offer the attrac tive possibility of using less well trained personnel When automatic instruments are used, the operators need only be instructed for a few minutes about the mechanical op eration of the instrument itself, and training m threshold or screening techniques is not necessary
What Is Noise?
The usually accepted definition of noise is "any unwanted sound" the last speaker on a long program, the yowl of cats at midnight, a cough dunng a concert or play
The intensity of sound or noise is ordmanly expressed in terms of decibels (dB) A deci bel--unlike inches --is not stnctly a unit It is derived from a ratio between two pressures, a measured sound pressure and a reference sound pressure The reference for sound pressure level (SPL) m dyne/sq cm is 0 0002 It is expressed by the following equation
P dB = 20 logl0 p1
t
where Pi is the measured pressure and P2 the reference pressure Zero to 120 dB is an intensity ratio of 1 to 1,000,000 The counter part of intensity with reference to the ear is loudness which is measured in sones The frequency of sound or noise is measured m cycles per second, one cycle being produced by one positive and one negative change m pressure The number of these cycles per second determines the frequency of the sound, which in turn determines the sound pitch by international agreement, 440 Hz is
1514