OCCUPATIONAL HEALTH SURVEY NO. I022-H BEAUMONT WORKS
N. 0. Johnson ?.. SchmidtField Notes________________________
Anmonla Area
1981 April 8
J-20 Welding Exhaust
The welding exhaust unit in the maintenance shop will not effectively cover the entire area of the welding table. It is reconmended that the system be modi fied to provide effective coverage to the entire area.
Water Treatment
J-21 Chlorine Shed
The breathing air manifold at the chlorine shed is located at the center of the cylinder manifold area. A small chlorine leak had been detected and the area barricaded. Supervision indicated that the breathing air system would be used during repair efforts. The enployee would have to enter the barricaded area to connect his respirator to the system. It is reconmended that the breathing air manifold be repositioned so employees can use the system without potential exposure to leak3 during respirator connection.
PiO Maintenance
J-22
Low Breathing Air Pressure
A portable breathing air cart was in use by a welder. The gauge on the low pressure side of the regulator showed ^0 psig supplied to the respirator. The gauge was corroded and not responding properly. Plant procedures call for the pressure to be set at 100 psig. Use of the lower pressure could allow the respirator to be 'starved' for air creating a potential for the respirator to become a negative pressure device, allowing leaks of contaminated air to enter the facepiece and expose the user. It is reccranended that the gauge be replaced and the regulator tagged to indicate the proper pressure.
S-23
Ammonia Laboratory
Laboratory hood effectiveness improves dramatically as sources of emission are
placed behind 6 inches of the plane of the'sash (Engineering Standard H3U).
It is reconmended that lines be drawn in the hoods of the Amnonia Lab as
already done in the hoods of the adjacent labs.
'
S-24
Spill Prevention
Liquid waste containing acrylonitrile is collected in a container under a laboratory hood in the Petrochem Lab. It is reconmended that the container be placed in a catch pan to contain spills.
S-25 Welding Exhausts Hoods
Airflows are checked in 8 inches distance from the center of the hood cpenirgs. No actions are required if the airflow reaches 100 fpm and no Teachings in other distances are taken if it exceeds 100 fpm. During welding in the P<50 shops, the center of the exhaust opening was placed in greater distance than 8 inches. Since no airflow measurement results were posted or the distance was not determined within the required airflow of 100 fpm can be maintained,
DUP 0502293
DU 001937
W. D. Johnson R. Schmidt
Field Notes
S-25 Welding Exhausts Hoods (Cont'd.)
Page 2 1981 April 8
enployees could not be sure whether they are adequately protected. It should
be considered to give a practical guidance for the welder and post the distance .within the required airflow can be maintained.
S-26 Asbestos
Seme discrepancies exist in the opinion whether asbestos insulation still be removed by Du Pont employees or only by contractors. Area personnel stated that maintenance work on asbestos insulation i3 still, done by Du Pont employees. The electrical shop would still use respirators which no fit test is performed for. In the boiler house, the remaining asbestos insulation is not identified and labeled (Engineering Standard S^T) . Maintenance employees are being informed about the carcinogenicity of asbestos.
It is recommended that a consistent procedure be implemented for the plant and that all involved parties be Informed about its contents.
NDJ/RS/fb
DUP 0502294
DU 001938
OCCUPATIONAL HEALTH SURVEY NO. 1022-H BEAUMONT WORKS
N. D. Johnson R. SchmidtField Notes________________________
1981 April 9
HydanfS Area
J-27 Welding Exposure
A maintenance welder in the area shop had used a 3M 9920 disposable respirator for protection from zinc oxide fumes while working on galvanized metal. He
spoke of having suffered from metal fume fever on one occasion in the past and of other more recent occasions when he felt he was developing similar symptoms. He did not mention if the experiences were related to Du Pont operation, but
indicated the respirator helped him. It is recommended that these experiences be investigated for Du Pont capability and appropriate protective equipment provided, if warranted.
S-28 Self-Contained Breathing Apparatus
The pressure of two Scott Air Paks was below the full scale. The straps of both facepieces were not fully extended, and the regulator by-pass valves were open to flush contaminants fran the face piece. It is recommended that area personnel be trained to perform the monthly checks properly.
Aniline Area
J-29 Eyewash Station
S-30
The eyewash station in the center of the nitrobenzene area did not function properly on initial operation, e.g., low water pressure. On the third attempt it functioned properly. It is reconmended that the unit be repaired to function correctly.
Noise Control
A telephone is situated in a noise zone (>90 dBA). While calling, employees have to take out their hearing protection. It should be considered to install
a noise protection enclosure which allows phoning without hearing protection and without exposure to the noise.
S-31 Gloves
Rubber gloves are required in the spill procedures for protection against several chemicals. At least three different kinds of gloves were in use which were all called 'rubber gloves.' It is recommended that the use of gloves be reviewed on basis of their permeability, this is already planned.
S-32 Self-Contained Breathing Apparatus
A Scott Air Pak with a small cylinder was stored in a case labeled as 30-minutes unit. Even this small cylinder was filled under the full scale. It is recom mended that only adequate .emergency equipment be provided and personnel be
trained to check it properly.