Document po4NrZB1GpyJy42rpRB1apww
SOFT GASKET MATERIAL SELECTION GUIDE
SEALABILITYASTM
MEDIA TO BE SEALED**
RELAXATION--ASTM METHOD B, 212F, %, MAX. INTERNAL PRESSURE, in. Hg EXTERNALLY APPLIED STRESS, psi
LEAKAGE, ml/hr, MAX.
QUALIFIED RECOMMENDED MAXIMUM TEMPERATURE, F* ! ALCOHOL DUST-EXTERNAL ETHYLENE GLYCOL FREON 12 | GASOLINE-AROMATIC GREASE KEROSENE LUBRICANTS--E.P. OIL-FUEL OIL-HIGH ANALINE POINT
OIL-LOW ANALINE POINT OIL-SYNTHETIC WATER-EXTERNAL WATER-INTERNAL
MATERIAL
CM CM
zUoJ
oc
VICTOPAC 1 VICTOPAC 14' VICTOPAC 60 VICTOPAC 65
25 20 300 2 800 S S S F p F s F F P P P C S S 25 20 300 2 800 s s S F F F S F S F F F C S S 25 20 300 5 800 s s S S S S S S S s s S C S S 20 20 300 2 800 s S S S S S S S S S S S C S s
VICTOPAC 67
25 20 300 5 800 s S S S S s S S S S s S C S S
VICTOPAC 70
25 20 300 15 800 s S S S F s S S S S s S S s s
VICTQPAC 76
20 20 300 2 800 s S S S S S S S S S s S C s S
VICTOPAC 85
30 20
500 . 5 1000
FS FFFsSSSSs S C F F
VICTOPAC 100
15 20 2000
5 1100 S S S S S s S s S S S S S S
ASBESTOPRENE 233 40 10 1000 15 500 F S F P P F S F F F F F C s S
ASBESTOPRENE 243 35 15 2000 10 600 F S F F F S s S S S S S C F F
ASBESTOPAC 232 30 20 400 5 500 s S S P P s s S S S S S C S S
ASBESTOPAC 242 25 20 800 5 600 F S F F F S s S S S S S C F F
VICTOLEX 258
45 10 2000 30 300 P S F P. .P P s P F P P P u S S
VICTOLEX 342 VICTOLEX 423
50 10
800 15
300 F S S F F S s S S Sr S S c S S
40 20 1000 6 300 F S S- F P s s s S s S S c S S
VICTOLEX 433
45 20 1000 6 300 F S s F P u s u F p p P u s S
VICTOLEX 867
40. 20 1000 15 300 F s S F F s s s s S s S F s S
VICTORITE B
50 20 1000 6 250 P s F P P S s S s s s S c F P
VICTORITE R
50 20 1000 6 250 P s F P P s s s s s s S c F P
S--Satisfactory; F--Fair; P-Poor; U--Unsatisfactory; C-Call VICTOR
`Qualified Recommended Maximum Temperatures: There are a number of factors involved in determining maximum service tem peratures, such as flange design, bolting pattern, bolt torque, and operating conditions. The temperatures indicated represent oper ation under optimum conditions.
"Media to be Sealed: Compatibility of the gasket meterial and the media to be sealed depends on factors similar to those shown above. Ratings shown in chart are under good installation conditions.
No. 10106-CR
2
8-77