Document pmz5v6a6OBQ0GKZj42qpn7p5D
I
Disliilmlion of Polyclilorinjitrtl Iti|>licnyl.s in an Acrair.d Biological Oxidation Wastewater Treatment System
liy I*. S. K. (limi. II. Nack . mill J. 11. I'i.inn
ii.n 11:1.1.1:
,Cttlutitlm5 Ohiit 4.12(11
Polychlorinated biphenyls (PCI!) have received considernhlc attention over the last decade because of the slow biodegrudabil1 ty and Lhc possible toxicity to various eco systems 1 uc lud I up, human beings (HOLMES ct nl. 1970; RISEBItOUCH et al. 1968; JENSEN ct al. 1969; KOEMAN et nl. 1969; PltllSTT ct al. 1970 ; BIROS et al . 1970; PKAKALL and LINCER 1970; WILDISH 1970; VOS and KOl-MAN 1970; N1MM0 et al. 1971; HANSEN et al. 1971; V1 Ll.ENKUVK ct al. 1971; KEHKELD eL al. 1971; KURATSUNE cl al. 1971; MOSSER et al. 1971). PCB is distributed to the environment mainly throup.h various water courses. l'CB in waters, wastewaters, and coastal waters has been reported elsewhere (DUKE et al. 1970; A11UNG and JENSEN 1970; HOLDEN 1970; SCHMIDT ct al. 1971). However, the fate of PCU in water and wastewater treatment systems, especially in a secondary aerated oxidation system has not been studied. A knowledge of TCI) distribution in this particular pathway to the environment is of interest from the standpoint of its ultimate control. This study aims at determining the PCli distribution in a secondary aeration system and examining the effect of the substance on the system's performance.
Material and Method
A secondary sewage treatment laboratory system con sisting of an aeration tank (volume: 2340 cm^ at normal opera ting conditions) and a clarifier (volume: 2450 cm^) was em ployed in this study (see Figure 1). The feed rate was adjusted to provide 5-10 hours mean residence time. The air flow rate was adjusted to keep the dissolved oxygen level in the aeration tank at about 4 ppm or higher.
The wastewater employed for feed of the system was a natural wastewater collected from the effluent of primary treatment in a municipal sewage treatment plant (Jackson Pike Plant, Columbus, Ohio). A synthetic wastewater was not. considered to be appropriate for use in the treatability study although it might give an advantage of reproducibility of experimental results. PCB spiking into wastewaters was carried
12
Bulletin of Environmental Contamination A Totlcolofy, Vo! II, No. I (J) 1974 fcy Springer Verlu New Yolk Inr.
DSW 028360
STLCOPCB4012322
f
FIGURE 1. DIAGRAM OF A SECONDARY BIOLOCICAL OXIDATION SYSTEM
out using on ultrasonic emulsifier; i.e., I'CD (Aroclor 1254) was first dissolved in o certain amount of n-Butanol, and then, the mixture was emulsified in wastewater by treating with ultra sound at 0.2 - 0.3 ampere for 4 to 6 minutes.
The quantitative analysis method for PCD has been
delineated (REYNOLDS 1969; ARMOUR and BURKE 1970; ZITKO et al.
1971; ROTE and MURPHY 1971; SNYDER and REINERT 1971). A gas-
11 quid-chromatographic method was employed in this study.
Separation of PCB from other interfering substances was made
by extracting it with methylene chloride in the presence of
hydrochloric acid and 6odium chloride, concentrating the
mixture, and separating it through a silica gel column. A
gas-liquid-chromatograph, utilizing an electron capture de
tector and a 6' x 1/4" O.D.
2 mm I.D.) glass column packed
with 1.5 percent OV - 17/1.95 percent QF-1 on supelocoport was
employed under operating conditions as follows: column temp
erature, 195C; injector temperature, 220C; detector tempera
ture, 210*C; carrier gas, helium, carrier gas flow rate, 30 ml/
min; volume injected, 2pt.. The calibration of the chromatograph
was carried out and the chart was prepared for the quantitative
measurement.
In a typical experimental run, the secondary biological oxidation system 6hown in Figure 1 was operated for 5 to 11 days to reach a 6teady Btate condition, and then PCB was intro duced for a period of 2 to 3 days. Four to eight day6 of final
13
i
_______ J
DSM 028361
STLCOPCB4012323
operation was followed offer tho termination of t'lie PCB intro duction. The operating conditions of the system were os follows: feed rate, 3.91 cmVmin: sludge return rate, 3.44 cmJ/min: sludge output rate, 0: mean residence time in aera
tion tank, 9.98 hours.
P.csul ts and Discussion
'lWo experimental runs were conducted after completion
of several preliminary runs needed for adjustment of the opera
ting conditions. The results are shown in Figure 2 and in
dicate that a considerable amount of PCB accumulated in sludge.
For Experimental Run (1) concentrations in sludge of 6.14, 12,75,
32.33, and 17.33 ppin were found 1, 2, 3, and 5 days after I'CB
introduction, respectively. The feed concentration was 1.63
I
ppm. For Experimental Run (2) concentrations in sludge of
36.2, 109.6, 152.0, 105.6, 112,0, and 84.0 ppm were found re
f / < 0 Ji>i
spectively 1, 2, 3, 5, 6, and 10 days after PCB introduction
at the level of 16.88 ppm. Effluent solution, on the other
|innd, contained relatively small amounts of PCB. For Experi mental Run (1) the concentrations of 0.004, 0.0153, and 0.0225
rlV-CV,
ppm were found 1, 2, and 3 days after PCB introduction, re spectively. For Experimental Run (2) the effluents contained
I: :, , I
PCB concentrations of 0.006, 0.015, 0.042, 0.032, 0.022, and 0.015 ppm respectively, 1, 2, 3, 5, 8, and 10 days after the
4c(, I'j.'ikV/.'
PCB introduction. PCB concentrations in feed, effluent, and
sludge were 0.009, <0.001 and 0.07 ppm, reapectively when
*L\r1lr.
PCB was not spiked into the wastewater.
1
The interference of PCB on the system's performance in terms of BOD, COD, and TOC removal efficiencies was not clear. Microbiological studies are required to obtain further information on tills matter.
7.5%
Another view of the results involves consideration of the dynamic concentration response of PCB in effluents and sludges for the impulse type PCB input. As shown in Figure 2, PCB concentration in effluents and sludges rapidly increased with a 6tep increase of PCB in feed, and then, decreased rather slowly with the same step size decrease of PCB in feed. The response of the system comprising a completely mixed tank and a tank without a stirrer could be approximated by a 6econd or higher order dynamic model although the response was com plicated due to the sludge return and a lack of knowledge on the degree of mixing in the second tank.
ri<S. ('? !
.OC 4} , Ol o .VC
) i <-
a
According to the results, the secondary aerated bio logical oxidation system removes a high percentage of the PCB contained in wastewater. The treatment system, however, is
.>1 o,t:;
( t */,
3
1 0-
0SW 0^8362
STLCOPCB4012324
0,024
60
U 0.016
o uco 0.006 o
(a) Experimental Run (1); Low Level PCB Introduction
voo T3? O 01
0.056
0.068
60
G coH 0.060
0.032 4oC> 0.026 c cS 0.016 Oun
0.008
0
(b) Experimental Run (2); High Level PCB Introduction
FIGURE 2. PCB CONCENTRATION RESPONSES IN EFFLUENTS AND SLUDGES OF A
SECONDARY AERATION TANK SYSTEM FOR A PCB INPUT (Symbols:
' A, feed; , effluent; E, sludge)
.
15
QSW 028363
STLCOPCB4012325
i
tjot believed to biodegrade or convert PCB to lower molecular height or other types o chemical substances which are readily degradable. Instead, PCB Is expected to be dissolved in fats present in sludge, adsorbed at the surface of the suspended material in sludge, or ingested by microbial cells in sludge. A combination of all of the above effects probably are opera tive in the concentration of PCB in sludge. Further study should be conducted to expand upon the results since this knowledge is essential in modifying current sludge handling methods. Simultaneously, landfill, land spread, and ocean dumping, of sludge should be reexamined to keep PCB under con trol if the quantity of PCB discharge to streams increases. In addition, sludp.e incinccration should be reviewed to deter mine the fate of PCB in that system. Finally, a tertiary treat ment system such as activated carbon, should be studied to effect further removal of PCB from secondary effluents.
References
A1ILING, B., and JENSEN, S., Anal. Chcm. 4, 1483 (1970). ARMOUR, J. A., and BURKE, J. A., J. Assoc. Off. Anal. Chera. W.! (1970). BIROS, F. J., WAKER, A. M., and MEDBERY, A. Bull. Environ. Contam. Toxicol. 4, 317 (1970). DUKE, T. W., LOWE, J. I., and WILSON, A. J., JK., Bull. Environ. Contam. Toxicol.'!), 171 (1970). HANSEN, D. J., PARRISH, P. R., LOWE, J. I., WILSON, A. J., JR., and WILSON, P. D., Bull. Environ. Contam. Toxicol. 6^, 113 (1971). HOLDEN, A. V., Nature 228, 1220 (1970). t ( HOLMES, D. C., SIMMONS, J. H., and TATTON, J, 0. G. , Nature 216, 277 (1967). JENSEN, S., J01INELS, A. C., 0LSS0N, M., and 0TTEKBIND, G., Nature 224, 247 (1969). K0EMAN, J. H., TEN NOEVER DeBRAW, M. 0., and DeVOS, R. H., Nature 221, 1126 (1969). KURATSUNE, M., YOSHIMURA, T,, MATSUZAKA, J., and YAMAGUCH1, A., Health Serv. Mental Health Aam. Health Report. 86^ 1083 (1971).
16
0SW 028364
STLCOPCB4012326
f *MOSKKR, .1. I... FISHER, N. S., TKNO, T., aiu) WURSTEK, C. F.
W5, 1 y 1 (1V 72) -
Science
NIMNO, I). I(., BLACKMAN, K. K., WILSON, A. J., JK., and FORESTER, J., H. irliu' Biol. J_1. J VI (1971).
PEAKALL, D. B. , and LINGER, J. L. , Bloscl. 20, 958 (1970).
I'KLSTT, J., JEFFERIES, D. J., and MOORE, N. W., Environ. Pollut. I, 3 (jy70).
KKH FK1.D, B. M. , BRADLEY, R. I,., JR., and SUNDE, M. L. , Poultry Scl. 50, 1090 (1971).
REYNOLDS, L. M. , Bull. Environ. Contain. Toxicol. , 128 (1969).
R1SEBR0UGH, R. W., RIEC1IE, P., PEAKALL, D. B., HERMAN, S. C., end K1RVEN, H. N., Nature 220, 1098 (1968).
ROTE, J. W.t and MURPHY, P. C., Bull. Environ. Contain. Toxicol. (>, 377 (1971).
SCHMIDT, T. T., RlSEIiKOUCIl, U. W., and CRESS, F., Bull. Environ. Conlnm. Toxicol. J5, 235 (1971).
SNYDER D., and REtNERT, R., Bull. Environ. Contain. Toxicol. 6, 385
(1971).
"
VILLENEUVE, D. C., CHANT, D. L., PHILLIPS, V. E. J., CLARK, M. L., and CLEGG, D. J., Bull. Environ. Contain. Toxicol. 6^, 120 (1971).
VOS, J, C., and KOEMAN, J. H., Toxicol. Appl. Pharmacol. L7, 656 (1970).
WILDISH, D. J., Bull. Environ. Contam. Toxicol. !>, 202 (1970).
Z1TKO, V., HUTZINCER, O., and SAFE, S., Bull. Environ. Contam. Toxicol 6, 160 (1971).
17 I
DSW 028365
STLCOPCB4012327