Document pmp497DO5XvO91wEbBLd5mrEE

Heating Systems Boilers. Cast-Iron Radiation. Cast-Iron UJElL-flkLAIN COmPANY General Sales-Office: Michigan City, Indiana Distributors in all principal cities WEIL-McLAIN CAST IRON OIL-FIRED BOILERS HR Series Heavy Duty boilers for hori zontal rotary burners Special steel front plate and section sim plify rotary burner installation. Large fire box volume develops better combus tion conditions--high base eliminates high brick foundation. These boilers are also available as all-fuel units. Load range: steam 2,700-12,270 sq ft; water 4,450-19,630 sq ft. "HR" Series Heavy Duty Boiler BOILER FOR OIL AND OIL HEATING UNITS Designed specifically for efficient oil burning. Long flue travel extracts maxi mum heat. I=B=R rated, ASME con structed. Available in residential sizes as complete package units for forced hot water systems. Load range: Steam 285-3,400 sq ft; water 525-5,505 sq ft. WEIL-McLAIN CAST IRON GAS-FIRED BOILERS A complete line of jacketed gas-fired boilers for residential, commercial and industrial applications. Cast iron construction for long life. Special design features assure efficient fuel com bustion--longer fire travel through finned flues permits maxi mum heat absorption. A.G.A. approved for natural, mixed, manufactured or liquefied petroleum gases--ASME construc ted. Load range: steam 260-12,950 sq ft; water 300-20,720 sq ft. Type J Gas Boiler Weil-McLain Snug Cast Iron Baseboards and Radiation Snug Cast Iron Baseboard Panels provide a balanced combina tion of radiant convected heat which assures uniform tempera ture from floor to ceiling. Available in two heights--7)4 >n- x Snug Baseboard Panel 2% in. and 9% in. x 2)4 in. Complete line of metal finishing accessories. Solray Cabinet Radiators have attractive, easily cleaned cabinet top. Large wa terways store heat for release when burner shuts off. Raydiant Recessed Radiators are designed exclusively for recessing virtually flush in the wall--completely unobtrusive. Junior Radiators offer modern slender-tube design--can be installed in open recess if desired. 366 Heating Systems fSSr Aldrich Company 121 E. Williams St., Wyoming, Illinois ------- --~ ---------- --~ *VM*VMMW and Commercial Oil Burners The Aldrich line of vertical firetube steel boiler-burner units are ASME con structed and stamped, SBI rated and listed in rating book of Mechanical Con tractors Association. The Series "D" units are available in ten sizes for hot water heating, steam heating and hot water supply--oil or gas fired. Boiler shipped with round jacket, insulation, flue baffles, combustion chamber and tankless coil (if required) factory in stalled. Burner, trim and controls packed in carton. The Aldrich Series "C"--Gulf Stream boilers are available in five sizes from 495 to 1260 sq ft water or hot water heating and hot water supply--oil or gas fired. The packaged units are furnished completely erected, pre-wired with equipment installed. Units are compact, efficient and eco nomical in operation. Aldrich boilers furnished as high delivery hot water heaters internally galvanized ire wulable in wide range of sizes with outputs from 118 to 950 gph 100F rise. The Model E oil burner (0.5-4.0 gph) is available for domestic use and Model DX (4.5-10.0 gph) and JU (8.0-19.0 gph) for commercial applications. SERIES "D" BOILER-BURNER SPECIFICATIONS Boiler No. D-130 D-I60 D-220 D-2801D-360 D-450 D-530 D-610 D-730 D-890 Net Rating SBI Steam Sq Ft.................. Net Rating SBI Water Sq Ft................. Net Rating SBI Steam Btu/hr ......... Net Rating SBI Water Btu/hr................ Gross Output--Btu/hr.... Gross Input--Gas--Btu/hr... ....... Firing Rate--Oil--gph.................. Tankless Coil Output--gpm..................... Hot Water Heater (HSG) Output GPH 320 400 550 700 900 1100 1300 1500 1800 2200 580 720 995 1260 1620 1980 2340 2700 3240 3960 77000 87000 96000 108000 132000 149000 168000 189000 216000 243000 264000 297000 312000 351000 360000 405000 432000 486000 528000 594000 115000 144000 144000 180000 198000 248000 252000 315000 324000 405000 396000 495000 468000 585000 540000 675000 648000 810000 792000 990000 1.1 1.35 2.0 2.5 3.0 3.7 4.3 5.0 6.0 7.3 3H 4 4 4 5 5 6 6 8 8 @ 100 Rise (40-140F)....................... Storage Capacity--Boiler Gal................... Heating Surface--Sq Ft............................. Number of FJue Tuoes.......... no135 170 235 300 385 475 560 645 775 950 28 41 65 73 94 98 125 150 170 19 16 24 20 32 24 41 30 53 34 65 42 77 52 88 106 129 60 71 92 SERIES "C"--GULF STREAM SPECIFICATIONS _________________ Boiler No. C-10 C-12 C-14 C-20 C-25 Net Rating SB1 Water Sq Ft........................... Net Rating SBI Btu/hr...................................... Gross Output Btu/hr........................................... Gross Input--Gas--Btu/hr........................ Firing Rate--Oil--gph ....................................... Tankless Coil Output--gpm.......................... Hot Water Heater (HSG) Output GPH @ 100 495 580 720 995 1260 7400C 8700C 108000 149000 189000 99000 115000 144000 198000 252000 120000 132000 165000 250000 320000 1.0 1.1 1.35 2.0 2.5 33344 Rise (40M40F).....................................7......... storage Capacity--Boiler--Gallons................... Heating Surface--Sq Ft...................................... Number of Flue Tubes........................................ 118 135 170 235 300 19 23 29 31 39 16 19 24 32 41 20 20 20* 32 32 367 Gulf Stream Packages